SU-F-T-21: A Novel Beam-Light View, Collimating Applicator for HDR Ocular Conjunctiva Brachytherapy-Treatments

Purpose: We propose the use of a HDR X-ray source collimator to apply a conformal, relatively small, radiation suitable for a single fraction with short delivery time. In addition, this technique can be applied using a radioactive source. Methods: We have built a stainless steel 1.5 mm thick applicator, to accommodate the needle applicator of the Intra-Beam X-ray source. Additional cavity is created in the applicator to allow the hosting/nesting/positioning of a LED diode. This LED is allowing a pre-irradiation beam marking on the tissue. The visible light emitted from the opening of the collimated applicator will delineate/verify the aperture of the kV beam to be applied, as well as serve as distance indicator and will assist in the determination of dose to be delivered. For the evaluation of the collimated spatial dose distribution we have performed water tank measurements using (IBA Dosimetry) with a 0.4 cc ion chamber (IBA Dosimetry). We have scanned a two dimensional array with 1mm pitch in depth and 0.3 mm step size laterally. Additional verifications were conducted using Gaf-Chromic film for PDD measurements and Optical Stimulated Luminescence Dosimetry (OSLD, Landauer inc.) for absolute dosimetry. Results: The collimated applicator enables a conformal irradiated cross-section of about 3 mm square at the applicator surface was used in this study. A 180 seconds of 50 kVp delivery yielded 29 Gy, 20.6 Gy and 14.5 Gy at 5, 10 and 15 mm depths respectively. These results are in good agreement with the needle applicator depth dose curve published data. Conclusion: We have demonstrated the feasibility of focal HDR brachytherapy for conjunctival and ocular tumors, using the Intra-Beam needle applicator with in-house developed collimator. The delivery time was found to be several minutes- suitable for an intra-operative procedure and will allow dose fractionation deliveries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Various Applications of Precision Low-Energy Nuclear Electron Spectrometry in the KATRIN Tritium Neutrino Project

The energy scale of the main spectrometer in the KATRIN tritium project is required to remain stable within ±60 meV at an electron energy of 18.6 keV for two months in order to reach the intended sensitivity of 0.2 eV for the rest mass of the electron antineutrino. A natural source of reference electrons with an energy of 17824.3 ± 0.5 eV based on K -conversion electrons of the 32-keV nuclear γ-transition in {sup 83m}Kr from the decay of parent {sup 83}Rb was developed for this purpose using precision low-energy nuclear electron spectrometry. The spectroscopic parameters of {sup 83m}Kr/{sup 83}Rb sources fabricated by ion implantation into polycrystalline platinum foils were significantly better than the parameters of vacuum-deposited sources. A large-scale study of the influence of the physicochemical environment of atoms of different radioisotopes in various matrices of vacuum-deposited and implanted radioactive sources on the energy of emitted conversion and Auger electrons and on the structure of the corresponding energy spectra was conducted in the process. The possibility of application of photoelectron sources with a metallic converter as sources of reference electrons for the KATRIN project was also considered.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A radioactive tracer dilution method to determine the mass of molten salt

A new technique for molten salt mass determination, termed radioactive tracer dilution, that uses 22Na as a tracer was validated. It has been a challenging problem to determine the mass of molten salt in irregularly shaped containers, where a highly radioactive, high-temperature molten salt was used to process nuclear spent/used fuel during electrochemical recycling (pyro-processing) or for coolant/fuel salt from molten salt reactors. A radioactive source with known activity is dissolved into the salt. After a complete mixture, a small amount of the salt is sampled and measured in terms of its mass and radioactivity. By finding the ratio of the mass to radioactivity, the unknown salt mass in the original container can be precisely determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Opportunities to Reuse and Recycle Redundant Radioisotopes - 16023

Sixty plus years of nuclear research and operation in the UK has produced significant quantities of nuclear material. To those involved in decommissioning a site or facility, this material represents a liability that needs to be managed and eventually disposed of. However to those in the wider nuclear industry and supply chain, the radioisotopes represent a potential resource of valuable, and in some cases irreplaceable material for future work. There is therefore an opportunity to create a win-win by identifying material that could be recycled or reused, removing it from being a liability and creating value from what is considered a waste. The UK is currently focused on the clean up of nuclear sites and the safe disposal of legacy nuclear material. Whilst the bulk of legacy material on these sites is mixed wastes in various solid and liquid forms, some of it consists of material produced for research purposes in the form of radioisotopes or exotic fuels. This has resulted in a plethora of unirradiated and irradiated materials in store across the UK including: Depleted and natural Uranium, Enriched Uranium, Mixed U/Pu oxides, Uranium carbide and mixed U/Pu carbides, Thorium as metal and oxides, Research radioisotopes. The material exists in almost every conceivable state from pure metal and oxides to solutions. Some material is well characterised and free from extraneous debris, other material is poorly characterised and contaminated with chemicals, experimental residues and sweepings. In addition, to reduce the risk and potential hazard across the UK there has also been a period of consolidation of obsolete radioactive sources from a wide variety of industrial or medical facilities to secure storage within a licensed site. The waste hierarchy is an established principle for the management of wastes, radioactive or otherwise. Its principles are set out and it gives top priority to prevention in the first place. Where waste is produced, it gives priority to preparation for re-use, then recycling before consideration for disposal as a last resort. The term wastes may only be applicable to the owner of the material where they may view the material as unwanted, unusable, or a by-product. It does not necessarily follow that the material is a waste to all potential owners. Therefore it is important to consider the potential value of material before it is considered for disposal since there is a significant and growing market for radioisotopes across the world. This paper will outline some of the opportunities in the UK for the recycle of surplus radioisotopes and orphan material. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Light scalars and dark photons in Borexino and LSND experiments

Bringing an external radioactive source close to a large underground detector can significantly advance sensitivity not only to sterile neutrinos but also to “dark” gauge bosons and scalars. Here we address in detail the sensitivity reach of the Borexino-SOX configuration, which will see a powerful (a few PBq) 144 Ce– 144 Pr source installed next to the Borexino detector, to light scalar particles coupled to the SM fermions. The mass reach of this configuration is limited by the energy release in the radioactive γ -cascade, which in this particular case is 2.2 MeV. Within that reach one year of operations will achieve an unprecedented sensitivity to coupling constants of such scalars, reaching down to g ~ 10 –7 levels and probing significant parts of parameter space not excluded by either beam dump constraints or astrophysical bounds. Should the current proton charge radius discrepancy be caused by the exchange of a MeV-mass scalar, then the simplest models will be decisively probed in this setup. In conclusion, we also update the beam dump constraints on light scalars and vectors, and in particular rule out dark photons with masses below 1 MeV, and couplings ϵ ≥ 10 –5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Belgian program for low and intermediate short lived waste management: from 1985 to license application

On 31 January 2013, ONDRAF/NIRAS, the Belgian Agency for Radioactive Waste and Enriched Fissile Materials, has introduced the construction and operation license application for the surface disposal facility for category A waste at Dessel. The objective of this paper is to present the development of this national programme. First the key milestones and their impact on the development of the project will be highlighted. This includes in particular: 1) the turning point in 1994, when ONDRAF/NIRAS converts its purely technic-scientific work method into an approach of participation that allows for societal aspects to be taken into account and 2) the decision of the government in 2006 in favour of the surface disposal of category A waste in Dessel. Then the paper presents the pillars of the long-term safety of a surface disposal and the principles for site selection and how they were applied to the surface disposal facility for category A waste at Dessel. The pillars of the long-term safety of a surface disposal are: (1) the passive confinement and isolation provided by the Engineering Barrier System (2) the contribution to this passive isolation and confinement by the site (3) the limitation of the radioactive source term, and (4) the control and monitoring measures. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Total Integrated Dose to Spent Fuel Pool Level Instrument Probes and Refueling Floor Personnel Dose Rates Meeting NRC Order EA-12-051 for a Typical Boiling Water Reactor - Paper 22

In reviewing the events after the March 11, 2011 Fukushima accident, the Nuclear Regulatory Commission (NRC) issued Order EA-12-051, Reference 1, requiring new reliable spent fuel pool (SFP) instrumentation for pool level determination under beyond design basis event conditions. In 2013, URS prepared a calculation for a typical Boiling Water Reactor to determine the Total Integrated Dose (TID) potentially to be imparted to radiation sensitive underwater probes (one primary and one backup) planned for meeting this Order. Additionally, URS calculated the radiological dose rates to an individual standing on the refueling floor for various SFP fill levels. NEI 12-02, Reference 2, defines the levels at which SFP condition identification is necessary as the following: Level 1 - level that is adequate to support operation of the normal fuel pool cooling system. Level 1 represents the higher of the following two points: - The level at which reliable suction loss occurs due to uncovering of the coolant inlet pipe, weir or vacuum breaker (depending on the design), or - The level at which the water height, assuming saturated conditions, above the centerline of the cooling pump suction provides the required net positive suction head specified by the pump manufacturer or engineering analysis. Level 2 - level that is adequate to provide substantial radiation shielding for a person standing on the spent fuel pool operating deck. Level 2 is based on either of the following: - 10 feet (+/- 1 foot) above the highest point of any fuel rack seated in the spent fuel pools, or - A designated level that provides adequate radiation shielding to maintain personnel radiological dose levels within acceptable limits while performing local operations in the vicinity of the pool. This level shall be based on either plant-specific or appropriate generic shielding calculations, considering the emergency conditions that may apply at the time and the scope of necessary local operations, including installation of portable SFP instrument channel components. Level 3 - level where fuel remains covered and actions to implement make-up water addition should no longer be deferred. Level 3 corresponds nominally (i.e. +/- 1 foot) to the highest point of any fuel rack seated in the spent fuel pool. The URS calculation did not define these levels or determine instrumentation setpoints. However, it determined refueling floor dose rates that could be used as a tool to determine the appropriate water depths for these levels. In determining the TID for the SFP probes and the radiological dose rates to the individual, the following radioactive sources were considered: 1. Spent Nuclear Fuel (SNF) stored in the spent fuel storage racks, 2. Local Power Range Monitors (LPRMs) stored above the top of the racks on hangers on the SFP walls 3. Radioactive material laden filters stored on platforms on top of the racks, and 4. Control Rod Blades (CRBs) stored above the top of the racks on hangers on the SFP walls. The TID for the SFP probes includes both the dose from normal operation (pool full of water) for the remaining plant life (an assumed 40 years, conservatively including an allowance for lifetime extension SFP loading) and, consistent with the NEI 12-02 guidelines, Reference 2, the assumed drop in elevation of the pool water level to the top of the spent fuel racks for a 6 hour period. The acceptable TID for the radiation-sensitive probe as defined by the manufacturer was 2x10{sup 9} rad. The individual on the pool deck was assumed to be standing on the edge of the pool with an unobstructed view of its contents, as a worst case scenario. Dose rates to this individual determined from direct shine from the same 4 sources were determined for SFP water levels varying from 1 ft above the SNF racks to 21 ft above the racks in one foot increments. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote detection of radioactive material using mid-IR laser–driven electron avalanche

Remote detection of a distant, shielded sample of radioactive material is an important goal, but it is made difficult by the finite spatial range of the decay products. Here, we present a proof-of-principle demonstration of a remote detection scheme using mid-infrared (mid-IR) (λ = 3.9 μm) laser–induced avalanche breakdown of air. In the scheme’s most basic version, we observe on-off breakdown sensitivity to the presence of an external radioactive source. In another realization of the technique, we correlate the shift of the temporal onset of avalanche to the degree of seed ionization from the source. We present scaling of the interaction with laser intensity, verify observed trends with numerical simulations, and discuss the use of mid-IR laser–driven electron avalanche breakdown to detect radioactive material at range.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Methodology for Determining the Concentration of Naturally Occurring Radioactive Materials in an Urban Environment

The detection of radioactive sources in an urban setting is greatly complicated by natural background radiation, which emanates from various materials including roadways, sidewalks, soil, and building exteriors. The method presented and demonstrated here represents an effort to characterize the concentration of naturally occurring radioactive material (NORM) in these types of materials. The location surveyed in this work was the Fort Indiantown Gap Combined Arms Collective Training Facility in Lebanon County, Pennsylvania. Over 70 measurements with a high-purity germanium detector were performed to ascertain the NORM concentrations present in the soil, asphalt, gravel, concrete, and walls found throughout the site. Monte Carlo radiation transport calculations were used to obtain detector responses for these various geometries and materials to convert these measurements into NORM concentration estimates. Lastly, synthetic spectra were simulated using the predicted source terms and compared to actual measurements, showing acceptable agreement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Energy Differential Response of Cancer Cells for Low Dose Irradiation:Impact of Monoenergetic Brachytherapy Sources

Purpose: The purpose of this work was to evaluate the energy differential response of cancer cells under identical dose exposure to asses the relevancy of mono-energetic sources for Brachytherapy treatments. Method and Materials: An electron energy spectrum impinging on lived breast cancer cell lines (MDA321) was obtained by placing a 19.65 {micro}Ci {sup 90}Sr/{sup 90}Y radioactive source in front of a non-uniform magnetic field constructed from two 5.08 x 5.0 cm x 2.54 cm neodimium ion permanent dipole magnets with a 1 cm separation gap. The cell lines were placed on the exit pole face of the magnet and were subsequently irradiated with different electron energies ranging from about 0.75 MeV to 1.85 MeV. The energy distribution was accurately measured with a scintillating fiber detector system that provided a 0.5% agreement with ICRU and a 5% energy resolution. The dosimetry was performed using a series of data acquired with a {sup 9}Sr/{sup 90}Y 4.5 mCi SIA-6 eye applicator, 6-21 MeV fixed energies from a Varian 2100 EX linac, EBT Gafchromic and Kodak ERT2 films, and an ion chamber detector. The accuracy of the dose rate obtained at different locations along and away from the magnet inside the cell containers was within 10.7%. Results: The cell lines were irradiated with a 0.5-4 Gy dose range. The data indicate a very strong differential energy response for electrons around 1 MeV (more lethal) compare to those with lesser or greater energy and a survival rate of at most 10% at very low dose (0.5-2 Gy). Conclusion: Mono-energetic Brachytherapy sources may provide a new pathway for radio-therapy treatment optimizations following a dedicated study showing very unusual high lethality in a specific energy window for MDA321 breast cancer cells.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing the radiation response of Cherenkov glass detectors with isotopic sources

Abstract Cherenkov detectors are widely used for particle identification and threshold detectors in high-energy physics. Glass Cherenkov detectors that are sensitive to beta emissions originating from neutron activation have been demonstrated recently as a potential replacement for activation foils. In this work, we set the groundwork to evaluate large Cherenkov glass detectors for sensitivity to MeV photons through first understanding the measured response of small Cherenkov glass detectors to isotopic gamma-ray sources. Counting and pulse height measurements are acquired with reflected glass Cherenkov detectors read out with a photomultiplier tube. Simulation was used to inform our understanding of the measured results. This simulation included radioactive source decay, radiation interaction, Cherenkov light generation, optical ray tracing, and photoelectron production. Implications for the use of Cherenkov glass detectors to measure low energy gammaray response are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monte Carlo calculated TG-60 dosimetry parameters for the {beta}{sup -} emitter {sup 153}Sm brachytherapy source

Purpose: The formalism recommended by Task Group 60 (TG-60) of the American Association of Physicists in Medicine (AAPM) is applicable for {beta} sources. Radioactive biocompatible and biodegradable {sup 153}Sm glass seed without encapsulation is a {beta}{sup -} emitter radionuclide with a short half-life and delivers a high dose rate to the tumor in the millimeter range. This study presents the results of Monte Carlo calculations of the dosimetric parameters for the {sup 153}Sm brachytherapy source. Methods: Version 5 of the (MCNP) Monte Carlo radiation transport code was used to calculate two-dimensional dose distributions around the source. The dosimetric parameters of AAPM TG-60 recommendations including the reference dose rate, the radial dose function, the anisotropy function, and the one-dimensional anisotropy function were obtained. Results: The dose rate value at the reference point was estimated to be 9.21{+-}0.6 cGy h{sup -1} {mu}Ci{sup -1}. Due to the low energy beta emitted from {sup 153}Sm sources, the dose fall-off profile is sharper than the other beta emitter sources. The calculated dosimetric parameters in this study are compared to several beta and photon emitting seeds. Conclusions: The results show the advantage of the {sup 153}Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using {sup 153}Sm seeds for the brachytherapy treatment.

60 APPLIED LIFE SCIENCES↗

On the property of measurements with the PTW microLion chamber in continuous beams

Purpose: The performance of liquid ionization chambers, which may prove to be useful tools in the field of radiation dosimetry, is based on several chamber and liquid specific characteristics. The present work investigates the performance of the PTW microLion liquid ionization chamber with respect to recombination losses and perturbations from ambient electric fields at various dose rates in continuous beams. Methods: In the investigation, experiments were performed using two microLion chambers, containing isooctane (C{sub 8}H{sub 18}) and tetramethylsilane [Si(CH{sub 3}){sub 4}] as the sensitive media, and a NACP-02 monitor chamber. An initial activity of approximately 250 GBq {sup 18}F was employed as the radiation source in the experiments. The initial dose rate in each measurement series was estimated to 1.0 Gy min{sup -1} by Monte Carlo simulations and the measurements were carried out during the decay of the radioactive source. In the investigation of general recombination losses, employing the two-dose-rate method for continuous beams, the liquid ionization chambers were operated at polarizing voltages 25, 50, 100, 150, 200, and 300 V. Furthermore, measurements were also performed at 500 V polarizing voltage in the investigation of the sensitivity of the microLion chamber to ambient electric fields. Results: The measurement results from the liquid ionization chambers, corrected for general recombination losses according to the two-dose-rate method for continuous beams, had a good agreement with the signal to dose linearity from the NACP-02 monitor chamber for general collection efficiencies above 70%. The results also displayed an agreement with the theoretical collection efficiencies according to the Greening theory, except for the liquid ionization chamber containing isooctane operated at 25 V. At lower dose rates, perturbations from ambient electric fields were found in the microLion chamber measurement results. Due to the perturbations, measurement results below an estimated dose rate of 0.2 Gy min{sup -1} were excluded from the present investigation of the general collection efficiency. The perturbations were found to be more pronounced when the chamber polarizing voltage was increased. Conclusions: By using the two-dose-rate method for continuous beams, comparable corrected ionization currents from experiments in low and medium energy photon beams can be achieved. However, the valid range of general collection efficiencies has been found to vary in a comparison between experiments performed in continuous beams of 120 kVp x ray, and the present investigation of 511 keV annihilation photons. At very high dose rates in continuous beams, there are presently no methods that can be used to correct for general recombination losses and at low dose rates the microLion chamber may be perturbed by ambient electric fields. Increasing the chamber polarizing voltage, which diminishes the general recombination effect, was found to increase the microLion chamber sensitivity to ambient electric fields. Prudence is thus advised when employing the microLion chamber in radiation dosimetry, as ambient electric fields of the strength observed in the present work may be found in many common situations. Due to uncertainties in the theoretical basis for recombination losses in liquids, further studies on the underlying theories for the initial and general recombination effect are needed if liquid ionization chambers are to become a viable option in high precision radiation dosimetry.

60 APPLIED LIFE SCIENCES↗

The Auger Radioisotope Microscope: an instrument for characterization of Auger electron multiplicities and energy distributions

We describe a new instrument, the Argonne Auger Radioisotope Microscope (ARM), capable of characterizing the Auger electron (AE) emission of radionuclides, including candidates relevant in nuclear medicine. Our approach relies on event-by-event ion–electron coincidence, time-of-flight, and spatial readout measurement to determine correlated electron multiplicity and energy distributions of Auger decays. We present a proof-of-principle measurement with the ARM using x-ray photoionization of stable krypton beyond the K-edge and identify a bifurcation in the electron multiplicity distribution depending on the emission of K-LX electrons. Extension of the ARM to the characterization of radioactive sources of AE emissions is enabled by the combination of two recent developments: (1) cryogenic buffer gas beam technology to introduce Auger emitters into the detection region with well-defined initial conditions, and (2) large-area micro-channel plate detectors with multi-hit detection capabilities to simultaneously detect multiple electrons emitted in a single decay.

Auger emitters↗

Loading Capabilities of Irradiated 3-D Printed Polymers

Gamma radiation is the emission of a high-energy photon from a radioactive source. The photon then interacts with an atom potentially damaging it. While time has shown that gamma radiation has a little effect on metals, the same cannot be said about plastic. The use of these types of materials in radioactive areas has increased for many reasons ranging from the weight difference between plastics and metals to the costs associated with doing so. For example, a potential use for radiation resistant plastics could be longer lasting, cost effective, and light weight radiation detection devices sent to probe an area that may present unsafe conditions for humans to survey. For these reasons and more, finding a plastic polymer that can withstand radiation for an extended period of time would make a great impact on the nuclear industry. In this experiment, two different polymers will undergo a series of strength tests before and after being exposed to radiation after different amounts of time up to two weeks. There are two sets of plastic polymers that will be used. Each set will consist of an nonirradiated, control subset, and subsets subject to radiation for one day, one week, and two weeks. The radiation source is 1100 Ci cobalt- 60. The specimens are placed on a foam platform such that they will be exposed as evenly as possible. They are then lowered into the radiation chamber where they are surround by cobalt-60 sources and irradiated for the given amount of time. The specimens will be tested for tensile strength and flexural strength according to ASTM standards. For tensile testing, the specimen has a 'dog bone' shape. The specimen is gripped at the wide ends, and pulled away from the center at a constant rate until failure. To test flexural strength, the specimens will be subject to a 3-point bend test. The specimen is held in place by three points, center top side and both ends bottom side. Load is applied at a constant rate on the center of the specimen until failure. The calculations to be considered for comparison after performing these tests include the tensile strength and stress, elongation, flexural stress and strain, and elasticity. Once these tests are completed, testing specimens that have been 3D printed with different print orientations will be considered and tested. The results from both experiments will help create strong, radiation resistant products in a expeditious manner that could really push the current limitations and expand the use of radiation resistant material.

36 MATERIALS SCIENCE↗

Pulsational Pair-instability Model for Superluminous Supernova PTF12dam:Interaction and Radioactive Decay

Being a superluminous supernova, PTF12dam can be explained by a {sup 56}Ni-powered model, a magnetar-powered model, or an interaction model. We propose that PTF12dam is a pulsational pair-instability supernova, where the outer envelope of a progenitor is ejected during the pulsations. Thus, it is powered by a double energy source: radioactive decay of {sup 56}Ni and a radiative shock in a dense circumstellar medium. To describe multicolor light curves and spectra, we use radiation-hydrodynamics calculations of the STELLA code. We found that light curves are well described in the model with 40 M {sub ⊙} ejecta and 20–40 M {sub ⊙} circumstellar medium. The ejected {sup 56}Ni mass is about 6 M {sub ⊙}, which results from explosive nucleosynthesis with large explosion energy (2–3)×10{sup 52} erg. In comparison with alternative scenarios of pair-instability supernova and magnetar-powered supernova, in the interaction model, all the observed main photometric characteristics are well reproduced: multicolor light curves, color temperatures, and photospheric velocities.

79 ASTRONOMY AND ASTROPHYSICS↗

Silicon-Equivalent Neutron Dose Estimations

Radiation transport calculations are often used to estimate dose or exposure to components and personnel surrounding a radiation source. The sources for these calculations are decaying radionuclides within the various nuclear materials. Under long-term radiation exposure, some components may show signs of material damage such as hardening, cracking, discoloration, etc. resulting from the dose received from nearby radioactive sources. Radiation dose quantities are a useful means to correlate material damage or degradation to radiation interactions. The degradation is often dependent on how incident radiation interacts and deposits energy into the material. This dependence implies that radiation dose should be properly defined for the material effect of interest. Generic dose quantities, such as total energy deposited, may not necessarily correlate well for degradation of any given material.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗