Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Process Sample Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Analysis of DWPF Sludge Batch 6 (Macrobatch 7) Pour Stream Glass Samples

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 6 (SB6), also referred to as Macrobatch 7 (MB7), in June 2010. SB6 is a blend of the heel of Tank 40 from Sludge Batch 5 (SB5), H-Canyon Np transfers and SB6 that was transferred to Tank 40 from Tank 51. SB6 was processed using Frit 418. During processing of each sludge batch, the DWPF is required to take at least one glass sample to meet the objectives of the Glass Product Control Program and to complete the necessary Production Records so that the final glass product may be disposed of at a Federal Repository. Four pour stream glass samples and two Melter Feed Tank (MFT) slurry samples were collected while processing SB6. The samples were transferred to the Savannah River National Laboratory (SRNL) where they were analyzed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Northwest Africa 8535 and Northwest Africa 10463: New Insights into the Angrite Parent Body

The angrite meteorites are valuable samples of igneous rocks formed early in Solar System history (approx.4.56 Ga, summarized in [1]). This small meteorite group (approx.24 individually named specimens) consists of rocks with somewhat exotic mineral compositions (e.g., high Ca olivine, Al-Ti-bearing diopside-hedenbergite, calcium silico-phosphates), resulting in exotic bulk rock compositions. These mineral assemblages remain fairly consistent among angrite samples, which suggests they formed due to similar processes from a single mantle source. There is still debate over the formation process for these rocks (see summary in [1]), and analysis of additional angrite samples may help to address this debate. Toward this end, we have begun to study two new angrites, Northwest Africa 8535, a dunite, and Northwest Africa 10463, a basaltic angrite.

Santos, A. R.↗

Omics-Lethal Human Viruses, Influenza A Experiment IM101

The purpose of this experiment was to evaluate the host mouse response to wild-type Influenza A/Vietnam/1203/2004 (H5N1) virus, Influenza A/California/04/2009 (H1N1) virus, and Influenza A/Vietnam/1203/2004 (H5N1; "PB2-627E" and "NS1trunc124") infection. Sample data was obtained from whole mouse lung and processed for transcriptomics expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Transcriptomics dataset downloads have a direct relationship to a primary sample submission corresponding to a specific Influenza A virus host infection.

59 BASIC BIOLOGICAL SCIENCES↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

GeneLab: A Systems Biology Platform for Omics Analysis

NASA's GeneLab includes an open-access repository of some 200+ omics datasets generated by biological experiments relevant to spaceflight (including simulated cosmic radiation and microgravity). In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics knowledge, GeneLab is now transforming the data in the repository into actual biological and physiological knowledge of the genetic and proteomic signatures found in these samples. This processed data is being derived by establishing standard data analysis workflows vetted by 114 scientists who are members of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). AWG members from institutes spanning the U.S. and four other countries participate on a voluntary basis. The AWGs meet monthly to discuss data mining, compare results and interpretations, and test forthcoming releases of the GeneLab Data Systems (GLDS). GLDS version 3.0 has been available to the general public since October 1st 2018, and has been providing a professional state-of-the-art bioinformatics platform for everyone in the space biology community to upload their data into a space biology omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. The user interface for the platform is being designed to be accessible to a broad variety of users including those with limited bioinformatics experience, including high school and college students who can use it to learn about omics data analysis and space biology. As such, Genelab will constitute a powerful general public outreach capability of NASA and the Space Biology community at large. Data mining of the GeneLab database by the AWG has already started generating very interesting findings, including reports linking specific spaceflight conditions such as radiation, microgravity or carbon dioxide levels to molecular changes seen across various species. In this presentation, we will report on the current and future objectives for GeneLab, and review recent studies reported by the various AWGs relating molecular changes observed in various animal models and tissue with microgravity, radiation, circadian rhythm, hydration and carbon dioxide conditions.

Omics↗

GeneLab: A Systems Biology Platform for Omics Analysis: Disseminate and Reuse Data, Tools, and Samples Post-Project

NASA's GeneLab includes an open-access repository of some 200 plus omics datasets generated by biological experiments relevant to spaceflight (including simulated cosmic radiation and microgravity). In order to maximize the intelligibility of these data, particularly for users with limited bioinformatics knowledge, GeneLab is now transforming the data in the repository into actual biological and physiological knowledge of the genetic and proteomic signatures found in these samples. This processed data is being derived by establishing standard data analysis workflows vetted by 114 scientists who are members of the four GeneLab Analysis Working Groups (Animal AWG, Plant AWG, Microbe AWG, Multi-Omics AWG). AWG members from institutes spanning the U.S. and four other countries participate on a voluntary basis. The AWGs meet monthly to discuss data mining, compare results and interpretations, and test forthcoming releases of the GeneLab Data Systems (GLDS). GLDS version 3.0 has been available to the general public since October 1st 2018, and has been providing a professional state-of-the-art bioinformatics platform for everyone in the space biology community to upload their data into a space biology omics data commons, to process their data with vetted standard workflows and to compare to existing analyses. The user interface for the platform is being designed to be accessible to a broad variety of users including those with limited bioinformatics experience, including high school and college students who can use it to learn about omics data analysis and space biology. As such, Genelab will constitute a powerful general public outreach capability of NASA and the Space Biology community at large. Data mining of the GeneLab database by the AWG has already started generating very interesting findings, including reports linking specific spaceflight conditions such as radiation, microgravity or carbon dioxide levels to molecular changes seen across various species. In this presentation, we will report on the current and future objectives for GeneLab, and review recent studies reported by the various AWGs relating molecular changes observed in various animal models and tissue with microgravity, radiation, circadian rhythm, hydration and carbon dioxide conditions.

Omics↗

Rapid measurement of soluble xylo-oligomers using near-infrared spectroscopy (NIRS) and multivariate statistics: calibration model development and practical approaches to model optimization

Rapid monitoring of biomass conversion processes using techniques such as near-infrared (NIR) spectroscopy can be substantially quicker and less labor-, resource-, and energy-intensive than conventional measurement techniques such as gas or liquid chromatography (GC or LC) due to the lack of solvents and preparation methods, as well as removing the need to transfer samples to an external lab for analytical evaluation. The purpose of this study was to determine the feasibility of rapid monitoring of a biomass conversion process using NIR spectroscopy combined with multivariate statistical modeling, and to examine the impact of (1) subsetting the samples in the original dataset by process location and (2) reducing the spectral range used in the calibration model on model performance. We develop multivariate calibration models for the concentrations of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids at multiple points in a biomass conversion process which produces and then purifies XOS compounds from sugar cane bagasse. A single model using samples from multiple locations in the process stream showed acceptable performance as measured by standard statistical measures. However, compared to the single model, we show that separate models built by segregating the calibration samples according to process location show improved performance. We also show that combining an understanding of the sample spectra with simple multivariate analysis tools can result in a calibration model with a substantially smaller spectral range that provides essentially equal performance to the full-range model. We demonstrate that real-time monitoring of soluble xylo-oligosaccharides (XOS), monomeric xylose, and total solids concentration at multiple points in a process stream using NIR spectroscopy coupled with multivariate statistics is feasible. Segregation of sample populations by process location improves model performance. Models using a reduced spectral range containing the most relevant spectral signatures show very similar performance to the full-range model, reinforcing the importance of performing robust exploratory data analysis before beginning multivariate modeling.

09 BIOMASS FUELS↗

In Situ Strategy of the 2011 Mars Science Laboratory to Investigate the Habitability of Ancient Mars

The ten science investigations of the 2011 Mars Science Laboratory (MSL) Rover named "Curiosity" seek to provide a quantitative assessment of habitability through chemical and geological measurements from a highly capable robotic' platform. This mission seeks to understand if the conditions for life on ancient Mars are preserved in the near-surface geochemical record. These substantial payload resources enabled by MSL's new entry descent and landing (EDL) system have allowed the inclusion of instrument types nevv to the Mars surface including those that can accept delivered sample from rocks and soils and perform a wide range of chemical, isotopic, and mineralogical analyses. The Chemistry and Mineralogy (CheMin) experiment that is located in the interior of the rover is a powder x-ray Diffraction (XRD) and X-ray Fluorescence (XRF) instrument that provides elemental and mineralogical information. The Sample Analysis at Mars (SAM) suite of instruments complements this experiment by analyzing the volatile component of identically processed samples and by analyzing atmospheric composition. Other MSL payload tools such as the Mast Camera (Mastcam) and the Chemistry & Camera (ChemCam) instruments are utilized to identify targets for interrogation first by the arm tools and subsequent ingestion into SAM and CheMin using the Sample Acquisition, Processing, and Handling (SA/SPaH) subsystem. The arm tools include the Mars Hand Lens Imager (MAHLI) and the Chemistry and Alpha Particle X-ray Spectrometer (APXX). The Dynamic Albedo of Neutrons (DAN) instrument provides subsurface identification of hydrogen such as that contained in hydrated minerals

Mahaffy, Paul R.↗

Summary Report For The Analysis Of The Sludge Batch 7b (Macrobatch 9) DWPF Pour Stream Glass Sample For Canister S04023 (Rev. 1)

In order to comply with the Defense Waste Processing Facility (DWPF) Waste Form Compliance Plan for Sluldge Batch 7b, Savannah River National Laboratory (SRNL) personnel characterized the Defense Waste Processing Facility (DWPF) pour stream (PS) glass sample collected while filling canister S04023. This report summarizes the results of the compositional analysis for reportable oxides and radionuclides and the normalized Product Consistency Test (PCT) results. The PCT responses indicate that the DWPF produced glass that is significantly more durable than the Environmental Assessment glass.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization Report for the MP-1 Experiment Fabrication Campaign

This report covers the results of MP 1 fuel characterization analysis to provide a detailed understanding of the as-fabricated fuel that would be irradiated in the MP 1 (Mini-Plate 1) experiment. The work was performed at Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL). Characterization of the as-fabricated fuel was performed in accordance with Characterization Plan for the Fabrication of U 10Mo for the MP 1 Experiment, hereinafter the MP 1 Characterization Plan (MAQP 2016). Under the MP 1 Characterization Plan, fuel foils at different points in the foil fabrication process (e.g., hot rolled annealed, cold rolled annealed) were studied to understand the effect of various thermomechanical processes on the fuel microstructure. Samples were sent to each of the three organizations so that testing and analysis could be performed independently using similar equipment and a standardized set of measurement and analysis procedures. The MP 1 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare independently obtained results, and achieve a three-way validation. PNNL characterized 28 uranium–10 wt% molybdenum (U 10Mo) samples. Six pieces/specimens from each sample/foil were sectioned, in accordance with the MP 1 Characterization Plan. Similarly, INL and LANL also examined 24 and 17 U 10Mo specimens, respectively. These total 69 samples consist of six types of MP 1 characterization foils fabricated by Babcock and Wilcox Technologies (BWXT) from ingots produced by the Y-12 National Security Complex: • 0.047 in.-thick hot-rolled and annealed samples with and without Zr layers • 0.02 in.-thick cold-rolled and annealed samples with and without Zr layers • 0.01 in.-thick cold-rolled and annealed samples with and without Zr layers. Microstructure, chemical composition, carbide morphology, U 10Mo foil thickness, Zr thickness, mechanical properties (microhardness), and density were evaluated in both longitudinal and transverse directions for foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization Report for the MP-1 Experiment Fabrication Campaign (Rev.1)

This report covers the results of MP 1 fuel characterization analysis to provide a detailed understanding of the as-fabricated fuel that would be irradiated in the MP 1 (Mini-Plate 1) experiment. The work was performed at Pacific Northwest National Laboratory (PNNL), Idaho National Laboratory (INL), and Los Alamos National Laboratory (LANL). Characterization of the as-fabricated fuel was performed in accordance with Characterization Plan for the Fabrication of U 10Mo for the MP 1 Experiment, hereinafter the MP 1 Characterization Plan (MAQP 2016). Under the MP 1 Characterization Plan, fuel foils at different points in the foil fabrication process (e.g., hot rolled annealed, cold rolled annealed) were studied to understand the effect of various thermomechanical processes on the fuel microstructure. Samples were sent to each of the three organizations so that testing and analysis could be performed independently using similar equipment and a standardized set of measurement and analysis procedures. The MP 1 experiment will provide an opportunity to understand the effects of processing conditions on the final fuel microstructure, to compare independently obtained results, and achieve a three-way validation. PNNL characterized 28 uranium–10 wt% molybdenum (U 10Mo) samples. Six pieces/specimens from each sample/foil were sectioned, in accordance with the MP 1 Characterization Plan. Similarly, INL and LANL also examined 24 and 17 U 10Mo specimens, respectively. These total 69 samples consist of six types of MP 1 characterization foils fabricated by Babcock and Wilcox Technologies (BWXT) from ingots produced by the Y-12 National Security Complex: (a.) 0.047 in.-thick hot-rolled and annealed samples with and without Zr layers; (b.) 0.02 in.-thick cold-rolled and annealed samples with and without Zr layers; and (c.) 0.01 in.-thick cold-rolled and annealed samples with and without Zr layers. Microstructure, chemical composition, carbide morphology, U 10Mo foil thickness, Zr thickness, mechanical properties (microhardness), and density were evaluated in both longitudinal and transverse directions for foils of the three different thicknesses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 9 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4- 15.201). Testing indicates that the CC method produced mixed results. The CC method did not result in complete dissolution of either the SRAT Receipt or SRAT Product with some fine, dark solids remaining. However, elemental analyses did not reveal extreme biases for the major elements in the sludge when compared with analyses obtained following dissolution by hot aqua regia (AR) or sodium peroxide fusion (PF) methods. The CC elemental analyses agreed with the AR and PF methods well enough that it should be adequate for routine process control analyses in the DWPF after much more extensive side-by-side tests of the CC method and the PF method are performed on the first 10 SRAT cycles of the Sludge Batch 9 (SB9) campaign. The DWPF Laboratory should continue with their plans for further tests of the CC method during these 10 SRAT cycles.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Testing of the Defense Waste Processing Facility Cold Chemical Dissolution Method in Sludge Batch 10 Qualification

For each sludge batch that is processed in the Defense Waste Processing Facility (DWPF), the Savannah River National Laboratory (SRNL) tests the applicability of the digestion methods used by the DWPF Laboratory for elemental analysis of Sludge Receipt and Adjustment Tank (SRAT) Receipt samples and SRAT Product process control samples. DWPF SRAT samples are typically dissolved using a method referred to as the DWPF Cold Chemical or Cold Chem Method (CC), (see DWPF Procedure SW4-15.201- 2.1).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sampling and Analysis Plan for Partial Closure of Solid Waste Management Unit #16; Addendum Part I for Delineating BH-056

On July 11, 2022, Sandia National Laboratories in California (SNL/CA) submitted a Response to Regional Water Quality Control Board Comments on Soil Sampling Results for Closure of a Portion of SWMU #16 in response to the February 16,2022 San Francisco Bay Regional Water Quality Control Board’s (SFRWQCB) letter requesting supporting information for the recommended closure of 7,700 linear feet of abandoned sewer lines. On August 18, 2022, SFRWQCB further requested a Sampling and Analysis Plan (SAP) for additional “step-out” sampling to delineate the potential presence of benzidine near borehole BH-056, which is located near the former sewer line. SNL/CA is in the process of contracting Weiss Associates (Weiss) to perform and oversee the boring, sampling, analysis, and report development to determine the potential presence and extent of benzidine. This document outlines the work that is anticipated, including the development of the SAP, to complete the investigation and submit a final report to the SFRWQCB. The work proposed by Weiss provides an estimated schedule for completing the investigation and developing the addendum Part II SAP for the project. In addition, Weiss provided a preliminary estimate of the sample locations (see Attachment A) which serve as addendum Part I of the SAP requested by the SFRWQCB. The contractor will submit the addendum Part II SAP, to satisfy the SFRWQCB requirement, before proceeding with any work.

54 ENVIRONMENTAL SCIENCES↗

A Review of Flow Analysis Methods for Determination of Radionuclides in Nuclear Wastes and Nuclear Reactor Coolants

The safety and security nuclear power plant operations depends on the application of the most appropriate techniques and methods of chemical analysis, where modern flow analysis methods find increasing applications. Nevetheless, the current status of development of these methods is more limited than might be expected from their authentic advantages. The main aim of this contribution is to review automated flow analysis procedures developed with various detection methods for application in the nuclear energy industry. The flow analysis methods for determination of radionuclides that have been reported to date have been primarily focused mainly on environmental applications. The needs and benefits of the application of flow methods for the monitoring of nuclear wastes and for process analysis of the primary circuit coolants of light water nuclear reactors are discussed. Application of continuous flow methods (CFA) or injection methods (FIA, SIA) of flow analysis with radiometric detection shorterns the time of analysis and improves precision of determinations due to mechanization of time-consuming operations of sample processing. The use of mass spectrometry (MS) detection enables multicomponent analyses and determination of transuranic isotopes with much better limits of detection compared to radiometric detection.

radiochemical analysis, Sequential Injection and F↗

Formation of periodic interfacial misfit dislocation array at the InSb/GaAs interface via surface anion exchange

The relationship between growth temperature and the formation of periodic interfacial misfit (IMF) dislocations via the anion exchange process in InSb/GaAs heteroepitaxy was systematically investigated. The microstructural and electrical properties of the epitaxial layer were characterized using atomic force microscope, high-resolution x-ray diffraction, transmission electron microscopy, and Hall resistance measurement. The formation of interfacial misfit (IMF) dislocation arrays depended on growth temperature. A uniformly distributed IMF array was found in a sample grown at 310 °C, which also exhibited the lowest threading dislocation density. The analysis suggested that an incomplete As-for-Sb anion exchange process impeded the formation of IMF on sample grown above 310 °C. At growth temperature below 310 °C, island coalescence led to the formation of 60° dislocations and the disruption of periodic IMF array. All samples showed higher electron mobility at 300 K than at 77 K.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A core handling device for the Mars Sample Return Mission

A core handling device for use on Mars is being designed. To provide a context for the design study, it was assumed that a Mars Rover/Sample Return (MRSR) Mission would have the following characteristics: a year or more in length; visits by the rover to 50 or more sites; 100 or more meter-long cores being drilled by the rover; and the capability of returning about 5 kg of Mars regolith to Earth. These characteristics lead to the belief that in order to bring back a variegated set of samples that can address the range of scientific objetives for a MRSR mission to Mars there needs to be considerable analysis done on board the rover. Furthermore, the discrepancy between the amount of sample gathered and the amount to be returned suggests that there needs to be some method of choosing the optimal set of samples. This type of analysis will require pristine material-unaltered by the drilling process. Since the core drill thermally and mechanically alters the outer diameter (about 10 pct) of the core sample, this outer area cannot be used. The primary function of the core handling device is to extract subsamples from the core and to position these subsamples, and the core itself if needed, with respect to the various analytical instruments that can be used to perform these analyses.

Gwynne, Owen↗