Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development Towards Stable Chlorine Isotope Measurements of Astromaterials Using the Modified Middleton Source of an Accelerator Mass Spectrometer

The volatile element Cl can be lost during the formation and evolution of planetary bodies, leading to fractionation of its two stable isotopes 35Cl and 37Cl. Chlorine isotope variations (reported as δ37Cl in parts per thousand (‰) relative to Standard Mean Ocean Chloride, SMOC) are documented to exceed 80‰ between different lunar rock samples and have been variably interpreted as the fingerprint of degassing during accretion, magma ocean, or volcanic portions of lunar history. The large intersample and intrasample variations observed by both bulk isotope ratio mass spectrometry (IRMS) and in-situ secondary ion mass spectrometry (SIMS) methods are difficult to interpret in part because of a paucity of bulk Cl isotope measurements. This lack of high-precision bulk data is due to the relative rarity of IRMS laboratories capable of making these high precision measurements on small samples of precious planetary materials such as those returned by human or robotic exploration. Here we present a new method for performing high precision δ37Cl measurements using the modified Middleton ion source of an existing accelerator mass spectrometer. For samples with as little as 1 μg Cl–the equivalent of 2–4 mm3 of a typical lunar rock sample–the average cathode accuracy is ∼1‰. Cathode reproducibility is typically ∼1‰ (2σ) for samples with at least 10 μg of Cl, increasing to ∼3–6‰ for aliquots with ∼1–2 μg Cl, similar to published SIMS results and sufficient to study astromaterials from the Moon, Mars, or 4 Vesta, which have tens of ‰ observed variations.

Tyler S. Anderson↗

Measurement of Precision Geometric Distances to Three Anchor Points in the Local Universe

As stated in previous reports, our program, funded by a NASA/SARA 3-yr grant, is designed to measure distances directly with accuracies of 5% to three anchor points in the Local Universe. We are attacking this problem on three fronts, using Very Long Baseline Interferometry (VLBI) observations of NGC 4258, M 33, and Sgr A*. We plan to provide distance estimates, with a minimum of systematic uncertainty, that can be used to re- calibrate several "standard candles," such as Cepheid and RR Lyrae variables. This Will place the Galactic and extragalactic distance scales on much firmer ground. The program will provide crucial, independent checks and calibrations of extragalactic distance measurements, and will contribute to the ultimate success and impact of the HST Key Project on Extragalactic Distances and any future NASA astrometric missions. Additionally, since distances are fundamental to astrophysics, our results will affect a large number of general projects on NASA facilities such as the HST, CXO, and JWST.

Reid, Mark J.↗

A Grand Scan of the pMSSM Parameter Space for Snowmass 2021

We present a flexible framework for interpretation of SUSY sensitivity studies for future colliders in terms of the phenomenological minimal supersymmetric standard model (pMSSM). We perform a grand scan of the pMSSM 19-dimensional parameter space that covers the accessible ranges of many collider scenarios, including electron, muon, and hadron colliders at a variety of center of mass energies. This enables comparisons of sensitivity and complementarity across different future experiments, including both colliders and precision measurements in the Cosmological and Rare Frontiers. The details of the scan framework are discussed, and the impact of future precision measurements on Higgs couplings, the anomalous muon magnetic moment, and dark matter quantities is presented. The next steps for this ongoing effort include performing studies with simulated events in order to quantitatively assess the sensitivity of selected future colliders in the context of the pMSSM.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of ICESat-2 Ice Sheet Surface Heights, Based on Comparisons over the Interior of the Antarctic Ice Sheet

We collected kinematic Global Navigation Satellite Systems (GNSS) surface height data, on a 750‐km ground‐based traverse of the flat interior of the Antarctic ice sheet, for comparison with Ice, Cloud, and Land Elevation Satellite‐2 (ICESat‐2) surface heights. Vertical errors in the GNSS data are estimated to be 5.6 cm, comparable to results from a previous traverse and with year‐to‐year comparisons. Comparisons of the GNSS heights and 6 months of ICESat‐2 ATL03 photon‐based heights and ATL06 segment‐based heights indicate that the accuracy and precision of ICESat‐2 data are comparable to that of results from the ICESat mission: ATL03 is currently accurate to better than 5 cm with better than 13 cm of surface measurement precision, while ATL06 is currently accurate to better than 3 cm with better than 9 cm of surface measurement precision.

Brunt, K. M.↗

Ultrasonic Monitor

MicroUltrasonics PLR-1000 is a refined microprocessor-controlled version (usable on bolts, plates, liquids and gases) of the P2L2 developed by Langley Research Center. New technique is for nondestructive measurement of residual stress in various types of structures, for example, nuclear pressure vessels, pipes in nuclear reactors, offshore platforms, bridges, railroad tracks and wheels, aircraft wings, and engines. The instrument produces sound tone pulses that travel through a test specimen. PLR-1000 precisely measures speeds as stress increases speed of sound, tone changes, making precise measurements possible.

Source record↗

The Modernization of a Long-Focal Length Fringe-Type Laser Velocimeter

A long-focal length laser velocimeter constructed in the early 1980's was upgraded using current technology to improve usability, reliability and future serviceability. The original, free-space optics were replaced with a state-of-the-art fiber-optic subsystem which allowed most of the optics, including the laser, to be remote from the harsh tunnel environment. General purpose high-speed digitizers were incorporated in a standard modular data acquisition system, along with custom signal processing software executed on a desktop computer, served as the replacement for the signal processors. The resulting system increased optical sensitivity with real-time signal/data processing that produced measurement precisions exceeding those of the original system. Monte Carlo simulations, along with laboratory and wind tunnel investigations were used to determine system characteristics and measurement precision.

Meyers, James F.↗

14- by 22-Foot Subsonic Tunnel Laser Velocimeter Upgrade

A long-focal length laser velocimeter constructed in the early 1980's was upgraded using current technology to improve usability, reliability and future serviceability. The original, free-space optics were replaced with a state-of-the-art fiber-optic subsystem which allowed most of the optics, including the laser, to be remote from the harsh tunnel environment. General purpose high-speed digitizers were incorporated in a standard modular data acquisition system, along with custom signal processing software executed on a desktop computer, served as the replacement for the signal processors. The resulting system increased optical sensitivity with real-time signal/data processing that produced measurement precisions exceeding those of the original system. Monte Carlo simulations, along with laboratory and wind tunnel investigations were used to determine system characteristics and measurement precision.

Meyers, James F.↗

The muon g-2 experiment at Fermilab

The E989 collaboration has recently published the most precise measurement of the muon anomalous magnetic moment $a_\mu$ with an uncertainty of $0.46\,\mathrm{ppm}$. The new experimental world average of $a_\mu$ deviates by 4.2 standard deviations from the Standard Model prediction provided by the Muon g-2 Theory Initiative. Emerging results from ab-initio lattice QCD calculations for hadron-physics contributions allow to scrutinize this tantalizing hint for physics beyond the Standard Model for the first time in a three way comparison. To extract the value of $a_\mu$ a frequency comparison experiment is performed with spin-polarized muons confined in a superbly controlled electric and magnetic field environment. A measurement of the difference between the Larmor and the cyclotron frequency, the so-called anomalous spin precession frequency, is combined with a high-precision measurement of the magnetic field environment which is performed using nuclear magnetic resonance techniques. I discussed the most recent result of the Fermilab Muon g-2 experiment's first physics data run performed in 2018. I reported on the experimental improvements implemented for the subsequent science runs that will allow the collaboration to achieve the ultimate goal of $0.14\,\mathrm{ppm}$ uncertainty on $a_\mu$.

Fertl, Martin↗

Measurement of precision oscillator phase noise using the two-oscillator coherent down-conversion technique

The characterization of precision frequency standard phase noise and spurious outputs is addressed, using the two-oscillator coherent downconversion technique. Focus is on techniques for making accurate measurements of phase noise and spurious outputs within 100 KHz of a carrier. Significant sources of measurement error related to hardware design problems and inadequate measurement procedures are discussed: measurement errors resulting from system noise sources, phase-locked loop effects, and system bandwidth limitations. In addition, methods and design considerations for minimizing the effects of such errors are presented. Analytic discussions and results are supplemented with actual test data and measurements made using measurement hardware developed at the Ball Corporation, Efratom Division.

Christopher J. Pagnanelli↗

Direct Subsurface Measurements through Precise Micro Drilling

Wellbore integrity is a significant problem in the U.S. and worldwide, which has serious adverse environmental and energy security consequences. Wells are constructed with a cement barrier designed to last about 50 years. Indirect measurements and models are commonly used to identify wellbore damage and leakage, often producing subjective and even erroneous results. The research presented herein focuses on new technologies to improve monitoring and detection of wellbore failures (leaks) by developing a multi-step machine learning approach to localize two types of thermal defects within a wellbore model, a prototype mechatronic system for automatically drilling small diameter holes of arbitrary depth to monitor the integrity of oil and gas wells in situ, and benchtop testing and analyses to support the development of an autonomous real-time diagnostic tool to enable sensor emplacement for monitoring wellbore integrity. Each technology was supported by experimental results. This research has provided tools to aid in the detection of wellbore leaks and significantly enhanced our understanding of the interaction between small-hole drilling and wellbore materials.

42 ENGINEERING↗

A Comprehensive Radial Velocity Error Budget for Next Generation Doppler Spectrometers

We describe a detailed radial velocity error budget for the NASA-NSF Extreme Precision Doppler Spectrometer instrument concept NEID (NN-explore Exoplanet Investigations with Doppler spectroscopy). Such an instrument performance budget is a necessity for both identifying the variety of noise sources currently limiting Doppler measurements, and estimating the achievable performance of next generation exoplanet hunting Doppler spectrometers. For these instruments, no single source of instrumental error is expected to set the overall measurement floor. Rather, the overall instrumental measurement precision is set by the contribution of many individual error sources. We use a combination of numerical simulations, educated estimates based on published materials, extrapolations of physical models, results from laboratory measurements of spectroscopic subsystems, and informed upper limits for a variety of error sources to identify likely sources of systematic error and construct our global instrument performance error budget. While natively focused on the performance of the NEID instrument, this modular performance budget is immediately adaptable to a number of current and future instruments. Such an approach is an important step in charting a path towards improving Doppler measurement precisions to the levels necessary for discovering Earth-like planets.

NASA-NSF Extreme Precision Doppler Spectrometer in↗

Advanced optical measuring systems for measuring the properties of fluids and structures

Four advanced optical models are reviewed for the measurement of visualization of flow and structural properties. Double-exposure, diffuse-illumination, holographic interferometry can be used for three-dimensional flow visualization. When this method is combined with optical heterodyning, precise measurements of structural displacements or fluid density are possible. Time-average holography is well known as a method for displaying vibrational mode shapes, but it also can be used for flow visualization and flow measurements. Deflectometry is used to measure or visualize the deflection of light rays from collimation. Said deflection occurs because of refraction in a fluid or because of reflection from a tilted surface. The moire technique for deflectometry, when combined with optical heterodyning, permits very precise measurements of these quantities. The rainbow schlieren method of deflectometry allows varying deflection angles to be encoded with colors for visualization.

Decker, A. J.↗

Measurement of Precision Geometric Distances to Three Anchor Points in the Local Universe

Our program, funded by a NASA/SARA 3-yr grant, seeks to provide a much improved foundation of r the extra-galactic distance scale. The goal is to measure geometric distances with accuracies of 5% of better to several anchor points in the Local Universe. There are three objects that we are observing in order to attack this problem: NGC 4258, M 33, and Sgr A*. We plan to provide distance estimates, with a minimum of systematic uncertainty, that can be used to recalibrate several "standard candles," such as Cepheid and RR Lyrae variables. This will place the extragalactic distance scales on much firmer ground. The program will provide crucial, independent checks and calibrations of extragalactic distance measurements, and will contribute to the ultimate success and impact of the HST Key Project on Extragalactic Distances and any future NASA astrometric missions. Additionally, since distances are fundamental to astrophysics, our results will affect a large number of general projects on NASA facilities such s the HST, CXO, and JWST.

Reid, Mark J.↗

Nuclear charge densities in spherical and deformed nuclei: Toward precise calculations of charge radii

Precise measurements of atomic transitions affected by electron-nucleus hyperfine interactions offer sensitivity to explore basic properties of the atomic nucleus and study fundamental symmetries, including the search for new physics beyond the standard model of particle physics. Specifically, such measurements, augmented by atomic and nuclear calculations, will enable extraction of the higher-order radial moments of the charge-density distribution in spherical and deformed nuclei. The new data impose higher precision requirements on a theoretical description. The nuclear charge density is composed of the proton point distribution folded with the nucleonic charge distributions. The latter induce subtle relativistic corrections due to the coupling of nucleon magnetic moments with the nuclear spin-orbit density. Additional corrections come from the effect of center-of-mass projection. We assess the precision of nuclear charge density calculations by studying the behavior of relativistic and center-of-mass motion corrections to the second and fourth charge radial moments. Special attention has been paid to the magnetic spin-orbit density associated with the local variations of the spin-orbit current. The calculations for semimagic and open-shell nuclei are performed in the framework of self-consistent mean-field theory using quantified energy density functionals and density-dependent pairing forces. We used the general expression for the spin-orbit form factor that is valid for spherical and deformed nuclei. We studied the impact of various correction terms on the charge radii, fourth radial moments, diffraction radii, and surface thickness of spherical and deformed nuclei. The spin-orbit corrections to charge radial moments and surface thickness show strong shell fluctuations which can make an appreciable effect when aiming at high-precision predictions of isotopic shifts. The inclusion of relativistic and center-of-mass corrections impacts the quality of energy density functionals optimized to charge radii data. To establish reliable constraints on the existence of new forces from isotope shift measurements, precise calculations of nuclear charge densities of deformed nuclei are needed. The proper inclusion of the spin-orbit charge density and other correction terms is essential when aiming at extraction of subtle effects which become particularly visible in isotopic trends. It is also important when developing high-quality nuclear energy density functionals optimized using heterogeneous datasets involving absolute charge radii, differential charge radii, and charge form factor properties deduced from electron-scattering data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative 2D thermometry in turbulent sooting non-premixed flames using filtered Rayleigh scattering

This paper demonstrates the application of a thermometry method in turbulent sooting non-premixed flames using filtered Rayleigh scattering (FRS). Fuel tailoring is used to establish a specific C 2 H 2 -based fuel mixture such that temperature can be determined accurately by a single FRS measurement over the entirety of mixture fraction space, or equivalently, for all relevant thermo-chemical states. Evaluation is performed in a hierarchy of flows to establish measurement precision and accuracy. Initial assessments in a series of heated fuel mixtures; non-sooting, near-adiabatic flat flames; and laminar non-premixed sooting flames show accuracy of the approach over a full range of expected temperatures and high single-shot measurement precision (e.g., 65 < <#comment/> S N R < <#comment/> 80 ) for temperatures between 1900 and 2200 K. Subsequently, 2D temperature measurements are evaluated in a turbulent non-premixed sooting flame. For the current fuel mixture, the local mixture-averaged Rayleigh scattering cross section is nearly constant over all composition space, and thus traditional laser Rayleigh scattering (LRS) is used as a measurement standard in the absence of soot. The results show excellent agreement between the proposed FRS thermometry approach and LRS in non-sooting regions. In the presence of soot, the proposed FRS-based approach shows no signs of interference. In addition, 2D temperature imaging shows high SNR (60–74) over all temperature conditions. Thus, we believe the proposed methodology successfully provides a high-resolution 2D temperature method under turbulent sooting flame conditions.

Pu, Jinpeng↗

Beam maser measurements of CH3OH rotational transitions

Precise measurements of rotational transitions in methanol are reported that were made by means of beam maser spectrometers. No hyperfine structure was resolved at a resonance line width of 8 kHz. Accurate center frequencies for the transitions measured are useful for determining Doppler shifts for observed interstellar lines.

Gaines, L.↗

Measurements of the charge ratio and polarization of cosmic-ray muons with the Super-Kamiokande detector

We present the results of the charge ratio (𝑅) and polarization (𝑃$^{𝜇}_{0}$) measurements using decay electron events collected between September 2008 and June 2022 with the Super-Kamiokande detector. Because of its underground location and long operation, we are able to perform high-precision measurements by accumulating cosmic-ray muons. We measured the muon charge ratio to be 𝑅 = 1.32 ± 0.02⁢(stat +syst) at 𝐸 𝜇 ⁢cos⁡𝜃 Zenith = 0.7$^{+0.3}_{−0.2}$ TeV, where 𝐸 𝜇 is the muon energy and 𝜃 Zenith is the zenith angle of incoming cosmic-ray muons. This result is consistent with the Honda flux model while indicating a tension with the 𝜋⁢𝐾 model of 1.9⁢𝜎. We also measured the muon polarization at the production location to be 𝑃$^{𝜇}_{0}$ = 0.52 ± 0.02 (stat+syst) at the muon momentum of 0.9$^{+0.6}_{−0.1}$ TeV/𝑐 at the surface of the mountain; this also suggests a tension with the Honda flux model of 1.5⁢𝜎. This is the most precise measurement ever to experimentally determine the cosmic-ray muon polarization near 1 TeV/𝑐. These measurement results are useful to improve atmospheric neutrino simulations.

Atmospheric neutrino oscillations↗