Impacts of Experimentally Obtained Harmonic Spectrums of Residential Appliances on Distribution Feeder: Preprint

This paper focuses on the harmonic load flow study for a set of residential loads and the impacts of the harmonic contents on the distribution feeder. Owing to the increased use of the power electronic based appliances and energy efficient home equipment like the lighting loads, the percentage of non-linear loads has increased in the distribution system which can impact the system performance, loss, and stability. Thus a comprehensive knowledge of their power quality and harmonic analysis is essential to improve the load models, voltage stability assessment, determining possible interactions at harmonic frequencies, protection planning, and the effect of the system impedance. For this study, the household appliances include the lighting, power electronics, resistive, and motor loads with a nominal supply voltage of 120 V single-phase or 240 V split-phase at a nominal frequency of 60 Hz. The harmonic spectrum as obtained from the experimental data is used to solve the harmonic load flow for a detailed secondary network including the distribution transformer extracted from a real distribution feeder's model. Additionally, the impact of the voltage harmonic on a three phase test load is presented through experimental results. The harmonic data of the transformer terminal voltage as obtained from the former load flow study is scaled to generate the source voltage for the three phase configuration of the grid simulator to make the test setup very similar to a real scenario.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hardware-in-the-Loop Testbed for Cyber-Physical Security of Photovoltaic Farms

In the last decades, modem grids with distributed energy resources, such as photovoltaic (PV) farms, are increasingly vulnerable to cyber-attacks that seriously affect the stability and performance of the power system. While cyber-physical security of smart grids is extensively studied, most of the existing work focuses on the grid level and neglects the modeling and features of device-level power electronics converters (PECs). Furthermore, establishing a high-fidelity simulation testbed that can simulate harmonic frequencies of the PV farm is in urgent need. In this paper, a high-fidelity and real-time hardware-in- the-loop testbed is built to simulate the harmonics of power electronics converters for cyber-physical security of PEC-enabled PV farms. Based on this testbed, the impact of typical cyber-attacks and physical faults on the PV converter can be analyzed, thus providing a foundation for cyber-attack detection, root cause diagnosis, and resilient control to mitigate the adverse effects of cyber-attacks.

14 SOLAR ENERGY↗

Real-time Event Detection Using Rank Signatures of Real-world PMU Data

Timely detection of power system events is a crucial task, which can facilitate the implementation of remedial actions to improve reliability, resiliency, and security of the system. Meanwhile, the widespread deployment of phasor measurement units (PMUs) makes it possible to develop data-driven event detection techniques. However, relying purely on data without incorporating domain knowledge for the event detection task in power systems poses substantial security and stability risks due to issues associated with data misinterpretation and model accuracy. In this regard, we propose a real-time event detection method using real-world PMU data by incorporating domain knowledge to adequately capture the event signatures. Specifically, we track the change in rank signatures of PMU data to accurately localize the events. To optimize the detection process, we incorporate an offline Bayesian optimization algorithm to tune the parameters by efficiently searching for the best values. The experiments using the real-world PMU dataset from a U.S. interconnection show that the proposed event detection approach can efficiently detect the events from PMU data streams with high accuracy.

Ghasemkhani, Amir↗

Comparative Study of Data-Driven Area Inertia Estimation Approaches on WECC Power Systems

With the increasing integration of inverter-based resources into the power grid, there has been a notable reduction in system inertia, potentially compromising frequency stability. To assess the suitability of existing area inertia estimation techniques for real-world power systems, this paper presents a rigorous comparative analysis of system identification, measurement reconstruction, and electromechanical oscillation-based area inertia estimation methodologies, specifically applied to the large-scale and multi-area WECC 240-bus power system. Comprehensive results show that the system identification-based approach exhibits superior robustness and accuracy relative to its counterparts.

area inertia estimation↗

High-efficiency, air-stable manganese–iron oxide nanoparticle-pigmented solar selective absorber coatings toward concentrating solar power systems operating at 750 °C

Solar selective absorber coating with long-term thermal stability at high temperatures ≥750 °C in air is an important component to reduce the levelized cost of energy (LCOE) of concentrating solar power (CSP) systems toward 50% power efficiency and dispatchable solar electricity. Conventionally, solar spectral selectivity requires multilayer-interference coatings implemented by stringently controlled vacuum deposition, and these coatings degrade significantly at >700 °C in air. Herein, we established a quantitative design approach and demonstrated a proof-of-concept air-stable, manganese–iron oxide nanoparticle (NP)-pigmented solar selective coatings with a high solar absorptance of ~93%, a relatively low thermal emittance of ~52%, and an optical-to-thermal energy conversion efficiency >89% under 1,000× solar concentration at 750 °C toward Generation 3 CSP systems. These coatings demonstrate spectral selectivity using cost-effective spray coating approach, a notable improvement over conventional vacuum-deposited, multilayer solar selective coatings for low-cost, high-efficiency solar thermal receivers. In contrast to the thermal degradation of spectrally non-selective benchmark Pyromark 2500 coatings at 750 °C in air, the solar absorptance of the MnFe 2 O 4 -pigmented coatings on stainless steel 310 (SS 310) substrates is increased to ~92.9% and the optical-to-thermal energy conversion efficiency is improved to 89.7% after serving at 750 °C in air for 700 h. X-ray diffraction results reveal that this improvement is due to the transformation of MnFe 2 O 4 NPs into more thermodynamically stable, non-stoichiometric manganese-rich manganese ferrite and iron-rich manganese–iron oxide phases after 500 h aging at 750 °C. For >1,000 h-endurance testing at 750 °C in air and the subsequent 19 day-night thermal cycling between 750 °C (12 h/cycle) and 25 °C (12 h/cycle) on SS 310 substrates, the thermal degradation is mainly due to the CrO x microflake formation from SS 310 substrates rather than the coatings, which can be suppressed by preoxidizing the surface of SS 310. With lower emittance matrix material and further optimization of pigment NP stoichiometry, concentration, and coating thickness, it is promising to achieve an optimized thermal efficiency ≥92.5% with long-term thermal stability at 750 °C for Generation 3 CSP systems.

14 SOLAR ENERGY↗

Large-Signal Stability Improvement of Parallel Grid-Forming Inverter-Driven Black Start: Preprint

With the rapid increase of inverter-based resources in modern grids, advanced grid-forming (GFM) inverter capa- bilities, such as system restoration and operation under faults, are urgently needed to realize power electronics-dominant grids at scale. One such capability is inverter-driven black start using GFM inverters. This paper analyzes the ability of two recently proposed advanced GFM controls to help GFM inverters sustain system-wide, off-nominal conditions and remain synchronized until they can overcome the momentary overloading as more GFMs join the process without generator sequence coordination or communications and finally stabilize the grid. Through an extensive set of 1,200 full-order electromagnetic transient simu- lations, we evaluate the black-start process while employing the various GFM inverter controls. The results show that the GFM current limiter and primary control have a significant impact on the stability of the system during dynamic operating conditions and thus impact the success of inverter-driven system restoration.

current limit↗

Electrical Systems of Pumped Storage Hydropower Plants: Electrical Generation, Machines, Power Electronics, and Power Systems

Adjustable-speed (AS) pumped storage hydropower (PSH) technology has the potential to become a large, consistent contributor to grid stability enabling higher penetrations of wind and solar energy on the future U.S. power system. AS-PSH has high-value characteristics, such as fast response to provide ancillary services to the grid, because it is a power converter interface with the grid (like battery storage), but at the same time it has the energy content large enough to supply both short-term (seconds-to-minutes) and long-term (minutes-to-hours) of energy needs, like more conventional power plants. However, designs must be optimized to lower the capital expenditure (CapEx) and to provide a high-quality grid interface capability (e.g. power quality, ancillary service provider, fault-tolerant or fault ride-through capability), which is a primary factor in the acceptance of AS-PSH into a utility’s generation mix. This CapEx will be greatly affected by the cost savings associated with the civil structure, turbine design, power electronics, control systems, or unique generator designs. A holistic design must be considered to get a full picture of the benefits of the technology proposed. The AS-PSH can be controlled to reduce the impact of transient disturbance on a power system and at the same time can be controlled to minimized subsequent component fatigue and potential oscillation modes within the plant, with the overall impact in reducing the operational expenditures (OpEx).Generating clean power to meet standards such as Institute of Electrical and Electronics Engineers (IEEE) 519 and International Electrotechnical Commission (IEC) 1000-3-2 will be a continuing challenge. For many technology developers, however, improved AS-PSH technologies will become a key component of generator-storage systems of the future given the prospects of increased performance and decreasing costs, and the ever-increasing penetration of renewables (e.g wind power and solar power).

13 HYDRO ENERGY↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response: Preprint

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believes that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost benefit↗

Impact of High PV Penetration on Voltage Stability

Photovoltaics (PV) are becoming increasingly relevant in modern power systems. With this increase also comes reliability concerns as photovoltaics behave differently than conventional generators. One reliability concern is voltage stability. In this paper, voltage stability of the Austin area in the Electric Reliability Council of Texas (ERCOT) system is studied using dynamic models with varying levels of photovoltaic penetration. The base case is set at 0% renewable penetration. Additional cases include 15% wind penetration and up to 65% photovoltaic penetration. The study results show that voltage/var control capacity is critical to voltage stability, which PV lacks. Voltage regulation of photovoltaics may cause over-voltage and voltage collapse may be more abrupt under high regional photovoltaic penetration.

Till, Jeremy↗

Leveraging PHIL for Inverter Functionality Requirement Evaluation to Ensure a Reliable Grid

This presentation showcases NREL's ongoing research on advanced Multi-point Power Hardware-in-the-Loop (PHIL) systems, enabling comprehensive evaluation of interoperability, stability, and wide-area stability in complex power grids. Key features include high-power PHIL capabilities, seamless PHIL Interfaces for effortless Grid-Following (GFL) and Grid-Forming (GFM) mode switching, and advanced multi-domain PHIL/Controller Hardware-in-the-Loop (CHIL) capabilities for evaluating diverse technology mixes, facilitating rigorous testing and validation of emerging power systems for reliable integration, enhanced resilience, and optimal performance.

lab capabilities↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Bayesian stability and force modeling for uncertain machining processes

Accurately simulating machining operations requires knowledge of the cutting force model and system frequency response. However, this data is collected using specialized instruments in an ex-situ manner. Bayesian statistical methods instead learn the system parameters using cutting test data, but to date, these approaches have only considered milling stability. This paper presents a physics-based Bayesian framework which incorporates both spindle power and milling stability. Initial probabilistic descriptions of the system parameters are propagated through a set of physics functions to form probabilistic predictions about the milling process. The system parameters are then updated using automatically selected cutting tests to reduce parameter uncertainty and identify more productive cutting conditions, where spindle power measurements are used to learn the cutting force model. The framework is demonstrated through both numerical and experimental case studies. Results show that the approach accurately identifies both the system natural frequency and cutting force model.

42 ENGINEERING↗

Probability Density Function Control of Frequency Fluctuations in Renewable-Rich Power Systems

The stochastic nature of renewable energy sources (RESs) necessitates treating power system frequency response as a random process with a nonstationary probability density function (PDF). Here, based upon the stochastic distribution control theory originated by the second author, this paper proposes a novel stochastic controller to improve the frequency PDF in power grids when integrating a large amount of RESs, thereby minimizing the effects of uncertainties and enhancing overall system stability. The key idea is to manipulate the controllable power generation resources so that the frequency PDF is make to follow a target PDF by using the stochastic distribution control theory originated by the second author. The proposed method can easily be plugged into existing automatic generation controls for multi-area transmission grids. The proposed method is validated via a modified Kundar's two area system and 240-bus Western Electricity Coordinating Council systems. The simulation results show that the proposed control shapes the frequency PDF narrower and sharper, leading to a notable improvement toward minimizing the effects of randomness and uncertainty during grid operation.

frequency↗

Asymmetry underlies stability in power grids

Abstract Behavioral homogeneity is often critical for the functioning of network systems of interacting entities. In power grids, whose stable operation requires generator frequencies to be synchronized—and thus homogeneous—across the network, previous work suggests that the stability of synchronous states can be improved by making the generators homogeneous. Here, we show that a substantial additional improvement is possible by instead making the generators suitably heterogeneous. We develop a general method for attributing this counterintuitive effect to converse symmetry breaking , a recently established phenomenon in which the system must be asymmetric to maintain a stable symmetric state. These findings constitute the first demonstration of converse symmetry breaking in real-world systems, and our method promises to enable identification of this phenomenon in other networks whose functions rely on behavioral homogeneity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Response Analysis to Monitor and Identify Changes in the Impedance of a Photovoltaic Panel Measured Online using a Power Optimizer

Photovoltaic (PV) cells are generally modeled as a current source due to photocurrent, p-n junction diodes with parasitic resistance, capacitance, and inductance. This paper proposes online frequency response analysis (FRA) to measure the impedance of a PV panel using an existing panel-level power optimizer in a PV system. The algorithm will actively perturb a small signal into a 300 W rooftop PV panel and compute its small signal impedance. The technology discussed is easy to incorporate, requires no additional hardware, doesn't alter the stability of the system, and is implemented at a steady-state point. The power optimizer initially stabilizes at an operating point and then perturbs the PV current via FRA and computes PV panel impedance. The relative standard deviation test conducted indoors under 300 W/m 2 illumination on a PV panel shows a less than 5% error rate in PV panel impedance magnitude and phase is measured using a power optimizer.

14 SOLAR ENERGY↗

Power Quality and Stability in a Cluster of Microgrids with Coordinated Power and Energy Management

Distributed Energy Resources (DER) such as photovoltaic (PV) systems and battery energy storage systems (BESS) can be operated collectively as microgrids. Microgrids can be effective in meeting local load requirements as well as in improving the power quality and stability in a modern power distribution system. Multiple microgrids can also be operated in a coordinated manner as a cluster, to improve the resiliency of the power distribution system. In the event of an outage caused by a transmission system failure, the microgrids in a cluster can use their distributed generation capacity and energy storage resources to recover and extend power availability to the critical loads in the system. In this paper, an illustrative cluster of two microgrids based on the IEEE 13-bus model with DERs has been used, to demonstrate the operation of the concept using real-time simulations. Using real-time simulations, capabilities such as switching reconfiguration following faults, identification of optimal DER placement for effective power quality management, and power electronic controller validation have been demonstrated. For the two-microgrid cluster, this paper also presents improvements in load voltage quality and

Chowdhury, Prithwiraj Roy↗

A Neural Network-Based Power Mismatch Elimination Strategy for Integrated Solar and ESS AC/DC Systems (MARS)

The multiport autonomous reconfigurable solar power plant (MARS) is a promising concept for the integration of photovoltaic (PV) and energy storage system (ESS) to the transmission ac grid and a high-voltage direct current (HVdc) link. The presence of PV and ESS in each arm of the MARS results in uneven distribution of active power among different submodules (SMs), thereby leading to unbalanced SM capacitor voltages and potentially compromising the system stability. Moreover, in the case of partial shadings, shaded PV SMs will suffer from decreased power injections causing power mismatch in the MARS system. To address this issue, a neural-network-based power mismatch elimination (NNPME) strategy is proposed in this article. The proposed NNPME strategy optimizes ESS usage and leverages both dc and ac circulating currents to facilitate power transfer among the SMs, arms, and phases of the MARS system. Simulation and control hardware-in-the-loop (cHIL) experiments demonstrate the effectiveness of the proposed NNPME strategy. Compared with the traditional approaches, the proposed NNPME strategy can significantly enhance system efficiency and ensure stable and continuous operation, even in the presence of uneven power distribution within the MARS system.

14 SOLAR ENERGY↗

Stability and Performance of an Undersea Kite Operating in a Turbulent Flow Field

In this paper, we examine the effects of flow disturbances resulting from turbulence on the dynamic behavior of an underwater energy-harvesting kite system that executes periodic figure-8 flight. Due to the periodic nature of the kite’s operation, we begin by assessing orbital stability using the Floquet analysis and stroboscopic intersection analysis of a Poincaré section, with the former analysis performed on a simplified “unifoil” model and the latter performed on a six-degree-of-freedom (6-DOF)/flexible tether model. With periodic stability established, a frequency-domain analysis based on a linearization about the kite’s path is used to predict the quality of flight path tracking as a function of the turbulence frequency. To validate the accuracy of these simulation-based predictions under flow disturbances, we compare the predictions of the kite’s behavior against the results of small-scale tow testing experiments performed in a controlled pool environment.

13 HYDRO ENERGY↗