Creating a Lunar Surface Power Grid
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
This paper presents the findings of our investigation into inverter-based resource- (IBR-) driven blackstart of electric grids. Four potential black-start configurations with different setups are presented. To evaluate the technical feasibility of IBR-driven black start in the four configurations, a behavioral model of inverters that mimics current-limited inverter operation is developed using variable resistors in the MATLAB Simulink/Simscape environment. The inverter model is connected to an induction motor through transformers and a transmission line to simulate its startup. Simulation results show that even with the limited current supply capability of inverters because of their physical constraints, IBRs can black-start a motor under certain conditions. Results also show that by using soft-start techniques, such as ramped supply voltage, inrush currents can be reduced, thereby expanding the conditions under which IBRs can provide black-start support. Simulation results with different scenarios lead to discussions and key takeaways that could be valuable for further IBR-driven black-start research.
Abstract not provided.
A corrosion monitoring system includes one or more objects coupled to respective portions of a transformer tank. The one or more objects are configured to corrode before the respective portions of the transformer tank. At least one optical sensor is coupled to each of the objects. The at least one optical sensor has an optical output that changes in response to strain of the object. An analyzer is coupled to the at least one optical sensor. The analyzer is configured to perform one or more of detecting and predicting corrosion of the transformer tank based on the output of the at least one optical sensor.
Abstract not provided.
A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.
A corrosion monitoring system includes one or more objects coupled to respective portions of a transformer tank. The one or more objects are configured to corrode before the respective portions of the transformer tank. At least one optical sensor is coupled to each of the objects. The at least one optical sensor has an optical output that changes in response to strain of the object. An analyzer is coupled to the at least one optical sensor. The analyzer is configured to perform one or more of detecting and predicting corrosion of the transformer tank based on the output of the at least one optical sensor.
A monitoring system includes an array of optical sensors disposed within a transformer tank. Each optical sensor is configured to have an optical output that changes in response to a temperature within the transformer tank. An analyzer is coupled to the array of optical sensors. The analyzer is configured to determine a sensed temperature distribution based on the sensed temperature. The sensed temperature distribution is compared to an expected distribution. Exterior contamination of the transformer tank is detected based on the comparison.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.
A system-wide assessment of the Puerto Rico power system grid strength is studied when considering high levels of inverter-based resource penetration. This study is carried out in PSSE and assesses the impact of inverter-based resource (IBR) contributions in response to three-phase ground faults. A hypothetical 100% inverter-based generation scenario is created to assess the extreme impact on short circuit levels and a realistic scenario is considered to assess the impact to short circuit ratios. The overall conclusion is that short circuit capacity and current will drastically decrease in a high IBR scenario, an effect that is quantified in this paper. The short circuit ratio metric is typically used to assess the impact of IBR but generally overestimates grid strength due to not accounting for the impact from multiple IBRs. Other methods such as equivalent circuit based short circuit ratio and weighted short circuit ratio offer a more comprehensive consideration for multiple IBRs and can better account for their mutual interactions. The work presented in this paper is part of the PR100 study.
Modern power distribution grids suffer from multiple vulnerabilities due to the tight integration between the physical system and the cyber infrastructure. Sophisticated and malicious cyber attacks continue to adversely impact the grid operation leading to performance degradation, service interruption, and grid failure. State estimation plays an essential role in grid monitoring and advancing cyber-attack situational awareness. In this regard, this paper first proposes a distributed compressive sensing (CS) state estimation approach for an unobservable distribution grid. Further, the proposed distributed CS approach divides the distribution grid into sub-areas to perform local state estimation. Then an alternating direction method of multipliers (ADMM) based iterative information exchange among neighboring areas is employed to complete the estimation process. In this estimation process, the impact of loss of measurement data, false data injection (FDI), replay, and neighborhood cyber-attacks is analyzed. Extensive simulations are performed on the IEEE 37-bus and IEEE 123-bus standard networks to demonstrate the algorithm’s robustness to the aforementioned cyber-attacks. A quantitative analysis of computational complexity and simulation time of the distributed CS based approach is also presented.
This paper proposes and demonstrates a real-time condition monitoring method using gate driver integrated sensing circuits and sensor fusion algorithms. Power device on-state voltage (VDSon) measurement and junction temperature (Tj) sensing circuits with high noise immunity are built and integrated into an adaptive gate driver circuit for power modules. Considering the inherently noisy measurement environment of power converters, VDSon together with several other measurements are fused together to provide accurate descriptions of the stress and degradation of each power device. Furthermore, the gate driver circuit can actively control the turn-on gate voltage (VGSon) for each device based on the stress and degradation state. The proposed sensing circuits and power device condition assessment algorithms are implemented in a 75 KVA grid-tied power converter. This paper focuses on the sensing circuits hardware designs and testing in grid-tied power converter prototype and device stress index generation. More comprehensive results on the device state of health index generation will be presented in future work.
The power system is undergoing rapid evolution with increasing penetration of inverter-based resources (IBRs), large loads, microgrids, and power electronic devices. Ensuring reliable and stable operation of the modern power grid is a multi-faceted challenge that requires detailed understanding of this complex system. Dynamic stability is a major concern in maintaining the security of power grids as the generation mixes and large loads transitions to include high shares of power electronic devices. The operation of IBRs in regions with low system strength and higher grid impedances has been found to be the main reason behind many of the power system instabilities that manifest themselves in various types of oscillations and interactions that, if not properly addressed and damped, can jeopardize the reliable operation of the power system. Weak grid conditions compound such stability problems, particularly when many IBRs operate in proximity to and connect to weak power grids. Therefore, it is important to assess grid strength for planning, integration and operation of IBRs for a given power system. In this report, we aim to understand and classify existing methodologies for grid strength assessment, along with their limitations and future needs. Further, we aim to utilize the huge untapped potential in utilizing hydro energy resources in addressing some of the pertinent challenges of grid strength and reliable operation of modern power systems. Hydropower, historically valued for its flexibility and dispatchability, now faces new constraints due to reduced share of synchronous machines in the generation mix and seasonal variability of available water resources. Yet, these same plants present untapped potential beyond energy generation - notably, as providers of critical grid services. This report explores how hydropower plants, particularly through operation as synchronous condensers, can play a pivotal role in strengthening the grid amid evolving system dynamics.
Due to changes in electric distribution grid operation, new operation regimes have been recommended. Distribution grid optimal power flow (DOPF) has received tremendous attention in the research community, yet it has not been fully adopted across the utility industry. Our paper recognizes this problem and suggests a development and integration procedure for DOPF. We propose development of DOPF as a three step procedure of 1) processing the grid, 2) obtaining a tractable solution, and 3) implementing multiple solution algorithms and benchmarking them to improve application reliability. For the integration of DOPF, we demonstrate how a DOPF federate may be developed that can be integrated in a co-simulation environment to mimic the real-world conditions and hence improve its practicality to be deployed in the field. To demonstrate the efficacy of the proposed methods, tests on IEEE 123 bus system are performed where the usage of tractable formulation in DOPF algorithm development and its comparison to the benchmark solution are demonstrated.
There is growing interest in energy storage technologies due to the expansion of renewable energy sources that are inherently intermittent and the increasing frequency of extreme weather events that disturb the power grid. Power consumption in buildings makes up approximately 76% of all electricity usage on the grid and is primarily used for thermal applications such as space conditioning, hot water, and cooking. This makes thermal energy storage (TES) an ideal solution for many of these applications. Many TES technologies rely on latent energy storage, which utilizes the melting/solidification of phase change materials (PCM) to store energy. Typically, TES designs suffer from low power density due to their low inherent thermal conductivity. This limitation makes the deployment of TES in active applications difficult as the ease of access to energy is essential for effective use. Common routes for improving power density include high thermal conductivity additives or extended features such as fins that increase cost. This study presents an alternative approach to improving performance through increasing the overall surface area to volume ratio of the device, to increase the available area for convection to occur between the working fluid and PCM. In the study a commercial PCM was selected with a transition temperature ideal for space heating applications. The heat exchanger design utilizes a unique application of triply periodic minimal surfaces (TPMS) for macro-encapsulation of the PCM. The use of TPMS for heat exchangers has been growing in interest due to their high-surface area to volume ratios, which were previously unmanufacturable until the development of additive manufacturing. A modular system was designed and manufactured with a stereolithography resin printing system that is then backfilled with PCM. An experiment test set-up is designed to test the charge and discharge performance of the thermal storage using a conditioned air stream. The pressure drop of the design is tested across a variety of flow rates. When compared to existing experimental data within literature, there is excellent agreement based on the Reynolds number at similar hydraulic diameters. Several inlet temperatures are tested at consistent temperature differences from the phase change temperature for both charging and discharging. Additionally, the volumetric flow rate is varied for each temperature set point. It was found that increasing flow rate had diminishing returns in reducing the overall charge time of the TES. The temperature delta from the melting temperature was the primary contributor to the change in average heat flux with limited variation in average heat transfer rate between charging and discharging at similar inlet temperatures and flow rates. The TPMS heat exchanger design has a high air-side pressure drop but it provides high heat transfer rates. This helps maintain a high outlet temperature during discharge, which is important to thermal comfort applications. The design, manufacturing, and experimental characterization of the TES device will be presented as part of this study.