Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Stringy Bubbles Solve de Sitter Troubles

Finding four-dimensional de Sitter spacetime solutions in string theory has been a vexing quest ever since the discovery of the accelerating expansion of the universe. Building on a recent analysis of bubble-nucleation in the decay of (false-vacuum) AdS backgrounds where the interfacing bubbles themselves exhibit a de Sitter geometry we show that this resonates strongly with a stringy cosmic brane construction that naturally provides for an exponential mass-hierarchy and the localization of both gravity and matter, in addition to an exponentially suppressed positive cosmological constant. Finally, we argue that these scenarios can be realized in terms of a generalization of a small resolution of a conifold singularity in the context of a (Lorentzian) Calabi–Yau 5-fold, where the isolated (Lorentzian) two complex dimensional Fano variety is a four-dimensional de Sitter spacetime.

79 ASTRONOMY AND ASTROPHYSICS↗

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Towards the spatial resolution of metalloprotein charge states by detailed modeling of XFEL crystallographic diffraction

Oxidation states of individual metal atoms within a metalloprotein can be assigned by examining X-ray absorption edges, which shift to higher energy for progressively more positive valence numbers. Indeed, X-ray crystallography is well suited for such a measurement, owing to its ability to spatially resolve the scattering contributions of individual metal atoms that have distinct electronic environments contributing to protein function. However, as the magnitude of the shift is quite small, about +2 eV per valence state for iron, it has only been possible to measure the effect when performed with monochromated X-ray sources at synchrotron facilities with energy resolutions in the range 2–3 × 10 −4 (Δ E / E ). This paper tests whether X-ray free-electron laser (XFEL) pulses, which have a broader bandpass (Δ E / E = 3 × 10 −3 ) when used without a monochromator, might also be useful for such studies. The program nanoBragg is used to simulate serial femtosecond crystallography (SFX) diffraction images with sufficient granularity to model the XFEL spectrum, the crystal mosaicity and the wavelength-dependent anomalous scattering factors contributed by two differently charged iron centers in the 110-amino-acid protein, ferredoxin. Bayesian methods are then used to deduce, from the simulated data, the most likely X-ray absorption curves for each metal atom in the protein, which agree well with the curves chosen for the simulation. The data analysis relies critically on the ability to measure the incident spectrum for each pulse, and also on the nanoBragg simulator to predict the size, shape and intensity profile of Bragg spots based on an underlying physical model that includes the absorption curves, which are then modified to produce the best agreement with the simulated data. This inference methodology potentially enables the use of SFX diffraction for the study of metalloenzyme mechanisms and, in general, offers a more detailed approach to Bragg spot data reduction.

59 BASIC BIOLOGICAL SCIENCES↗

A study on the impact of using a subchannel resolution for modeling of large break loss of coolant accidents

The nuclear industry is investigating the feasibility of transitioning from 18- to 24-month fuel cycles because of the positive impact it would have on the operational costs for the current fleet of light-water reactors. A challenge to making this change is the increased risk of fuel fragmentation, relocation, and dispersal (FFRD) due to the known potential for ceramic fuel to pulverize into fine particles at the higher discharge burnups. Previous work has been performed by the Nuclear Energy Advanced Modeling and Simulation program to assess FFRD risk in high-burnup cores using the BISON fuel performance code and a coarse mesh thermal hydraulics (T/H) solution for a loss-of-coolant accident (LOCA) using the TRACE system T/H code. Because of the importance of the T/H solution for FFRD assessment, this study seeks to investigate the impact of using higher-fidelity subchannel techniques for modeling of the LOCA transient. CTF was used to model a subregion of a high-burnup core that was depleted by the Virtual Environment for Reactor Applications (VERA) multiphysics core simulator. Both coarse-mesh and pin-resolved models were created in CTF, and a consistent coarse-mesh TRACE model was also developed to allow for benchmarking the code results. Further, a large-break loss-of-coolant accident (LBLOCA) reflood transient was simulated using these three models, and results were compared. Results showed some consistent differences between the CTF and TRACE coarse models, including a higher peak cladding temperature (PCT) prediction in CTF and later quenching in CTF; however, the transient clad temperature behavior was similar, and these differences are likely due to post-critical heat flux heat transfer modeling differences and minimum film boiling temperature model differences. The pin-resolved results indicate that the PCT in the lumped model is often under-predicted by as much as 70 °C and that PCT occurs at a different location than the high-power pin in the assembly. The lumped model predicts a difference of 10 °C or less between the average and hot pins in the assembly, whereas the pin-resolved model predicts a range of over 100 °C. These results indicate that higher-fidelity T/H results may have an impact on predicted core behavior during LOCA, which may be important to consider when assessing FFRD risk.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

Methylammonium Lead Tribromide Single Crystal Detectors towards Robust Gamma-Ray Photon Sensing

In recent years, hybrid perovskite single crystalline solid-state detectors have shown promise in γ-ray spectroscopy. Here, the γ-ray photon induced electrical pulses are investigated, which are produced by perovskite solid-state detectors made with the commonly used methylammonium lead tribromide crystals with chlorine incorporation. Under low electric field detector operation, slow pulses generated by γ-rays with average rise times of 65 µs are observed, which decreases to 20 µs when a higher electrical field of 500 V cm -1 is applied. However, the baseline becomes noisy quickly, which prevents collection of clean pulses for spectra construction. Further, by systematically measuring the temperature dependence and current–voltage characteristics, such instability is attributed to the local ion migration under electrical field creating a fluctuating dark noise, which presents a major challenge in perovskite γ-ray detector technologies. It is demonstrated that cycling the bias between positive and negative polarity can stabilize the detector, allowing for longer periods of pulse accumulation for generating energy resolved spectra with resolutions of ≈35% at 59.6 keV and ≈25% at 662 keV at room temperature. The study indicates that the main limiting factors of perovskite-based γ-ray detectors are slow rise times and bias instability. Finally, these challenges must be properly addressed to achieve reproducible, high-resolution γ-ray detection.

47 OTHER INSTRUMENTATION↗

Parametric Finite Element Analysis of Naturally Corroded Steel Specimens Using 3D Surface Laser Scans

Corrosion is considered a uniform thickness reduction design guideline of the maritime industry. However, additionally, the corroded and irregular morphology of the surface affects the steel's load-bearing capacity and its impact on the strength and elongation behaviour of the steel is not yet fully understood. These effects on the local behaviour of steel structures under tensile loading were investigated with tensile tests on naturally corroded steel specimens and nonlinear finite element simulations including the corroded surface morphology with a uniform surface idealation. The models also include the deformed specimen shape. The developed approach led to highly accurate parametric finite element models predicting the ultimate tensile strength and longitudinal position of fracture. The results show that all included aspects are essential for accurate simulations, while solely the maximum available surface resolution was not as decisive.

corrosion↗

FPV Video Adaptation for UAV Collision Avoidance

First person view (FPV) technology for unmanned aerial vehicles (UAVs) provides an immersive experience for pilots and enables various personal and commercial applications such as aerial photography, drone racing, search and rescue operations, agricultural surveillance, and structural inspection. While real time video streaming from a UAV and vision-based collision avoidance strategies have been studied in literature as separate topics, in this paper we tackle collision avoidance in FPV scenarios, taking into account network delays and real time video parameters. We present a theoretical model for obstacle collisions that considers the current communication channel conditions, the real time video parameters, and the UAV's position relative to the closest obstacle. A video adaptation algorithm is then designed, using this metric, to tune the FPV video resolution, number of re-transmission attempts, and the modulation scheme to maximize the probability of avoiding collisions. This algorithm also takes into account specific latency constraints of the application. This video algorithm was evaluated in various scenarios and its ability to respond to both distances to the obstacle as well as the communication channel conditions was demonstrated. It was found that, for the considered scenarios, the performance of the proposed adaptive algorithm was, on an average, 58.63% higher than the closest non-adaptive one in terms of maximizing the probability of avoiding collision. Such collision avoidance strategies could be used to make UAV FPV applications safer and more reliable.

47 OTHER INSTRUMENTATION↗

Atomic electron tomography in three and four dimensions

Atomic electron tomography (AET) has become a powerful tool for atomic-scale structural characterization in three and four dimensions. It provides the ability to correlate structures and properties of materials at the single-atom level. With recent advances in data acquisition methods, iterative three-dimensional (3D) reconstruction algorithms, and post-processing methods, AET can now determine 3D atomic coordinates and chemical species with sub-Angstrom precision, and reveal their atomic-scale time evolution during dynamical processes. In this work, we review the recent experimental and algorithmic developments of AET and highlight several groundbreaking experiments, which include pinpointing the 3D atom positions and chemical order/disorder in technologically relevant materials and capturing how atoms rearrange during early nucleation at four-dimensional atomic resolution.

30 DIRECT ENERGY CONVERSION↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Development of a High-Rate Front-End ASIC for X-Ray Spectroscopy and Diffraction Applications

We developed a new front-end application-specific integrated circuit (ASIC) to upgrade the Maia X-ray microprobe. The ASIC instruments 32 configurable channels that perform either positive or negative charge amplification, pulse shaping, peak amplitude, and time extraction along with buffered analog storage. At a gain of 3.6 V/fC, 1-μs peaking time, and a temperature of 248 K, an electronic resolution of 13 and 10 e- rms was measured with and without a silicon drift detector (SDD) sensor, respectively. A spectral resolution of 170-eV full-width at half-maximum (FWHM) at 5.9 keV was obtained with an 55Fe source. The channel linearity was better than ± 1% with rate capabilities up to 40 kcps. The ASIC was fabricated in a commercial 250-nm process with a footprint of 6.3 mm × 3.9 mm and dissipates 167 mW of static power.

Vernon, Emerson↗

Hard X-ray imaging with sub-10 nm resolution by scanning bonded 2D multilayer Laue lenses

Multilayer Laue lenses (MLLs) offer significant advantages over traditional diffractive focusing optics, such as zone plates (ZPs), in terms of efficiency and durability when focusing hard X-rays to 10 nm and below. Typically, a pair of 1D MLLs is aligned independently to achieve point focusing. This approach only permits scanning microscopy by moving the sample stage, which presents a limitation when it comes to scanning large or bulky objects at high speed. In this study, we present an experimental demonstration of scanning monolithically bonded 2D MLLs while keeping the sample stationary, effectively addressing the limitation of the sample’s size and weight. We characterized the system’s positional and angular stabilities during scanning, which are critical parameters to the nanofocusing performance of MLLs. In addition, we provided the X-ray measurement results and corresponding image resolution analysis.

36 MATERIALS SCIENCE↗

Imaging Bias‐Driven Domain Wall Motion With Scanning Oscillator Piezoresponse Force Microscopy

Understanding ferroelectric domain wall dynamics at the nanoscale across a broad range of timescales requires measuring domain wall position under different applied electric fields. The success of piezoresponse force microscopy (PFM) as a tool to apply local electric fields at different positions and imaging their changing position, together with the information obtained from associated switching spectroscopies has fueled numerous studies of the dynamics of ferroelectric domains to determine the impact of intrinsic parameters such as crystalline order, defects and pinning centers, as well as boundary conditions such as environment. However, the investigation of sub-coercive reversible domain wall vibrational modes requires the development of new tools that enable visualizing domain wall motion under varying applied fields with high temporal and spatial resolution while also accounting for spurious electrostatic effects. Here, scanning oscillator piezoresponse force microscopy extends the investigation of domain wall dynamics to new regimes, providing direct visualization of domain wall position as a function of an external electric field that varies in time and location. In conclusion, this enables studying the energetics of field-driven ferroelectric domain wall motion, which is shown to obey a thermally activated flow regime in the millisecond timescale.

Piezoresponse Force Microscopy↗

Discriminating Accretion States via Rotational Symmetry in Simulated Polarimetric Images of M87

In 2017 April, the Event Horizon Telescope observed the shadow of the supermassive black hole at the core of the elliptical galaxy Messier 87. While the original image was constructed from measurements of the total intensity, full polarimetric data were also collected, and linear polarimetric images are expected in the near future. We propose a modal image decomposition of the linear polarization field into basis functions with varying azimuthal dependence of the electric vector position angle. We apply this decomposition to images of ray traced general relativistic magnetohydrodynamics simulations of the Messier 87 accretion disk. Furthermore, for simulated images that are physically consistent with previous observations, the magnitude of the coefficient associated with rotational symmetry, β2, is a useful discriminator between accretion states. We find that at 20 μas resolution, $| {\beta }_{2}| $ is greater than 0.2 only for models of disks with horizon-scale magnetic pressures large enough to disrupt steady accretion. We also find that images with a more radially directed electric vector position angle correspond to models with higher black hole spin. Our analysis demonstrates the utility of the proposed decomposition as a diagnostic framework to improve constraints on theoretical models.

79 ASTRONOMY AND ASTROPHYSICS↗

Molecular basis of C-S bond cleavage in the glycyl radical enzyme isethionate sulfite-lyase

Desulfonation of isethionate by the bacterial glycyl radical enzyme (GRE) isethionate sulfite-lyase (IslA) generates sulfite, a substrate for respiration that in turn produces the disease-associated metabolite hydrogen sulfide. Here, we present a 2.7 Å resolution X-ray structure of wild-type IslA from Bilophila wadsworthia with isethionate bound. In comparison with other GREs, alternate positioning of the active site β strands allows for distinct residue positions to contribute to substrate binding. These structural differences, combined with sequence variations, create a highly tailored active site for the binding of the negatively charged isethionate substrate. Through the kinetic analysis of 14 IslA variants and computational analyses, we probe the mechanism by which radical chemistry is used for C-S bond cleavage. This work further elucidates the structural basis of chemistry within the GRE superfamily and will inform structure-based inhibitor design of IsIA and thus of microbial hydrogen sulfide production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring the propagation of mechanical discontinuity using data-driven causal discovery and supervised learning

Mechanical wave transmission through a material is influenced by the mechanical discontinuity in the material. The propagation of embedded discontinuities can be monitored by analyzing the wave-transmission measurements recorded by a multipoint sensor system placed on the surface of the material. The proposed workflow monitors the propagation of mechanical discontinuity through three stages, namely initial, intermediate, and final stages, by using supervised learning followed by data-driven causal discovery. To the end, the workflow processes the multipoint waveform measurements resulting from a single impulse source, while considering the effects of wave attenuation, dispersion and multiple wave-propagation modes due to the discontinuity and material boundaries. Among various feature reduction techniques ranging from decomposition methods to manifold approximation methods, the features derived based on statistical parameterizations of the measured waveforms lead to reliable monitoring that is robust to changes in precision, resolution, and signal-to-noise ratio of the multipoint sensor measurements. The numbers of zero-crossing, negative-turning, and positive turning in the waveforms are the strongest causal signatures of the propagation of mechanical discontinuity. Higher order moments of the waveforms, such as variance, skewness and kurtosis, are also strong causal signatures of the propagation. Finally, the newly discovered causal signatures confirm that the statistical correlations and conventional feature rankings are not always statistically significant indicators of causality.

42 ENGINEERING↗

Smart Microbial Cells Couple Catalysis and Sensing to Provide High-Throughput Selection of an Organophosphate Hydrolase

Enzyme engineering for gain of function requires navigating a large combinatorial sequence space efficiently. Typically, many mutations are needed to get significant improvements, while a single “bad” mutation can inactivate the enzyme. To establish high-throughput screening and achieve enhanced resolution between two variants, genetic libraries of the organophosphate hydrolase enzyme paraoxonase 1 (PON 1 ) were rapidly screened via an engineered positive-feedback circuit: a p-nitrophenol (PNP)-specific transcription factor (TF) regulated expression of PON 1 , which catalyzed paraoxon breakdown and PNP production. Rare active mutant colonies, picked by simple visual fluorescence of a PON 1 –green fluorescent protein (GFP) fusion, were characterized. Furthermore, in a single screening round, high (library-scale) throughput enabled the discovery of enhanced paraoxon degradation activity in PON 1 , including structurally unexpected mutations.

59 BASIC BIOLOGICAL SCIENCES↗