Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-F-T-453: Improved Head and Neck SBRT Treatment Planning Using PlanIQ

Purpose: Treatment planning for Head and Neck(HN) re-irradiation is a challenge because of ablative doses to target volume and strict critical structure constraints. PlanIQ(Sun Nuclear Corporation) can assess the feasibility of clinical goals and quantitatively measure plan quality. Here, we assess whether incorporation of PlanIQ in our SBRT treatment planning process can improve plan quality and planning efficiency. Methods: From 2013–2015, 35 patients (29 retrospective, 6 prospective) with recurrent HN tumors were treated with SBRT using VMAT treatment plans. The median prescription dose was 45 Gy in 5 fractions. We retrospectively reviewed the treatment plans and physician directives of our first 29 patients and generated score functions of the dosimetric goals used in our practice and obtained a baseline histogram. We then re-optimized 12 plans that had potential to further reduce organs-at-risk (OAR) doses according to PlanIQ feasibility DVH and plan quality analysis and compared them to the original plans. We applied our new PlanIQ-assisted planning process for our 6 most recently treated patients and evaluated the plan quality and planning efficiency. Results: The mean plan quality metric(PQM) and feasibility adjusted PQM(APQM) scores of our initial 29 treatment plans were 77.1±13.1 and 88.7±11.9, respectively (0–100 scale). The PQM and APQM scores for the 12 optimized plans improved from 75.9±11.0 and 85.1±10.2 to 80.7±9.3 and 90.2±8.0, respectively (p<0.005). Using our newly developed PlanIQ-assisted planning process, the PQM and APQM scores for the 6 most recently treated patients were 93.6±6.5 and 99.1±0.6, respectively. The planning goals were more straightforward to minimize OAR doses during optimization, thus less planning and revision time were used than before. Conclusion: PlanIQ has the potential to provide achievable planning goals and also improve plan quality and planning efficiency.

60 APPLIED LIFE SCIENCES↗

Evaluation of a commercial automatic treatment planning system for prostate cancers

Recent developments in Radiation Oncology treatment planning have led to the development of software packages that facilitate automated intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT) planning. Such solutions include site-specific modules, plan library methods, and algorithm-based methods. In this study, the plan quality for prostate cancer generated by the Auto-Planning module of the Pinnacle{sup 3} radiation therapy treatment planning system (v9.10, Fitchburg, WI) is retrospectively evaluated. The Auto-Planning module of Pinnacle{sup 3} uses a progressive optimization algorithm. Twenty-three prostate cancer cases, which had previously been planned and treated without lymph node irradiation, were replanned using the Auto-Planning module. Dose distributions were statistically compared with those of manual planning by the paired t-test at 5% significance level. Auto-Planning was performed without any manual intervention. Planning target volume (PTV) dose and dose to rectum were comparable between Auto-Planning and manual planning. The former, however, significantly reduced the dose to the bladder and femurs. Regression analysis was performed to examine the correlation between volume overlap between bladder and PTV divided by the total bladder volume and resultant V70. The findings showed that manual planning typically exhibits a logistic way for dose constraint, whereas Auto-Planning shows a more linear tendency. By calculating the Akaike information criterion (AIC) to validate the statistical model, a reduction of interoperator variation in Auto-Planning was shown. We showed that, for prostate cancer, the Auto-Planning module provided plans that are better than or comparable with those of manual planning. By comparing our results with those previously reported for head and neck cancer treatment, we recommend the homogeneous plan quality generated by the Auto-Planning module, which exhibits less dependence on anatomic complexity.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-266: Proton PBS Plan Design and Robustness Evaluation for Head and Neck Cancers

Purpose: To describe a newly designed proton pencil beam scanning (PBS) planning technique for radiotherapy of patients with bilateral oropharyngeal cancer, and to assess plan robustness. Methods: We treated 10 patients with proton PBS plans using 2 posterior oblique field (2F PBS) comprised of 80% single-field uniform dose (SFUD) and 20% intensity-modulated proton therapy (IMPT). All patients underwent weekly CT scans for verification. Using dosimetric indicators for both targets and organs at risk (OARs), we quantitatively compared initial plans and verification plans using student t-tests. We created a second proton PBS plan for each patient using 2 posterior oblique plus 1 anterior field comprised of 100% SFUD (3F PBS). We assessed plan robustness for both proton plan groups, as well as a photon volumetric modulated arc therapy (VMAT) plan group by comparing initial and verification plans. Results: The 2F PBS plans were not robust in target coverage. D98% for clinical target volume (CTV) degraded from 100% to 96% on average, with maximum change Δ D98% of −24%. Two patients were moved to photon VMAT treatment due to insufficient CTV coverage on verification plans. Plan robustness was especially weak in the low-anterior neck. The 3F PBS plans, however, demonstrated robust target coverage, which was comparable to the VMAT photon plan group. Doses to oral cavity were lower in the Proton PBS plans compared to photon VMAT plans due to no lower exit dose to the oral cavity. Conclusion: Proton PBS plans using 2 posterior oblique fields were not robust for CTV coverage, due to variable positioning of redundant soft tissue in the posterior neck. We designed 3-field proton PBS plans using an anterior field to avoid long heterogeneous paths in the low neck. These 3-field proton PBS plans had significantly improved plan robustness, and the robustness is comparable to VMAT photon plans.

60 APPLIED LIFE SCIENCES↗

SU-G-201-09: Evaluation of a Novel Machine-Learning Algorithm for Permanent Prostate Brachytherapy Treatment Planning

Purpose: A novel, automated, algorithm for permanent prostate brachytherapy (PPB) treatment planning has been developed. The novel approach uses machine-learning (ML), a form of artificial intelligence, to substantially decrease planning time while simultaneously retaining the clinical intuition of plans created by radiation oncologists. This study seeks to compare the ML algorithm against expert-planned PPB plans to evaluate the equivalency of dosimetric and clinical plan quality. Methods: Plan features were computed from historical high-quality PPB treatments (N = 100) and stored in a relational database (RDB). The ML algorithm matched new PPB features to a highly similar case in the RDB; this initial plan configuration was then further optimized using a stochastic search algorithm. PPB pre-plans (N = 30) generated using the ML algorithm were compared to plan variants created by an expert dosimetrist (RT), and radiation oncologist (MD). Planning time and pre-plan dosimetry were evaluated using a one-way Student’s t-test and ANOVA, respectively (significance level = 0.05). Clinical implant quality was evaluated by expert PPB radiation oncologists as part of a qualitative study. Results: Average planning time was 0.44 ± 0.42 min compared to 17.88 ± 8.76 min for the ML algorithm and RT, respectively, a significant advantage [t(9), p = 0.01]. A post-hoc ANOVA [F(2,87) = 6.59, p = 0.002] using Tukey-Kramer criteria showed a significantly lower mean prostate V150% for the ML plans (52.9%) compared to the RT (57.3%), and MD (56.2%) plans. Preliminary qualitative study results indicate comparable clinical implant quality between RT and ML plans with a trend towards preference for ML plans. Conclusion: PPB pre-treatment plans highly comparable to those of an expert radiation oncologist can be created using a novel ML planning model. The use of an ML-based planning approach is expected to translate into improved PPB accessibility and plan uniformity.

60 APPLIED LIFE SCIENCES↗

Comparison of Planning Quality and Efficiency Between Conventional and Knowledge-based Algorithms in Nasopharyngeal Cancer Patients Using Intensity Modulated Radiation Therapy

Purpose: Intensity modulated radiation therapy (IMRT) is widely used to achieve a highly conformal dose and improve treatment outcome. However, plan quality and planning time are institute and planner dependent, and no standardized tool exists to recognize an optimal plan. RapidPlan, a knowledge-based algorithm, can generate constraints to assist optimization and produce high-quality IMRT plans. This report evaluated the quality and efficiency of using RapidPlan in nasopharyngeal carcinoma (NPC) IMRT planning. Methods and Materials: RapidPlan was configured using 79 radical IMRT plans for NPC; 20 consecutive NPC patients indicated for radical radiation therapy between October 2014 and May 2015 were then recruited to assess its performance. The ability of RapidPlan to produce acceptable plans was evaluated. For plans that could not achieve clinical acceptance, manual touch-up was performed. The IMRT plans produced without RapidPlan (manual plans) and with RapidPlan (RP-2 plans, including those with manual touch-up) were compared in terms of dosimetric quality and planning efficiency. Results: RapidPlan by itself could produce clinically acceptable plans for 9 of the 20 patients; manual touch-up increased the number of acceptable plans (RP-2 plans) to 19. The target dose coverage and conformity were very similar. No difference was found in the maximum dose to the brainstem and optic chiasm. RP-2 plans delivered a higher maximum dose to the spinal cord (46.4 Gy vs 43.9 Gy, P=.002) but a lower dose to the parotid (mean dose to right parotid, 37.3 Gy vs 45.4 Gy; left, 34.4 Gy vs 43.1 Gy; P<.001) and the right cochlea (mean dose, 48.6 Gy vs 52.6 Gy; P=.02). The total planning time for RP-2 plans was significantly less than that for manual plans (64 minutes vs 295 minutes, P<.001). Conclusions: This study shows that RapidPlan can significantly improve planning efficiency and produce quality IMRT plans for NPC patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Comprehensive Comparison of IMRT and VMAT Plan Quality for Prostate Cancer Treatment

Purpose: We performed a comprehensive comparative study of the plan quality between volumetric-modulated arc therapy (VMAT) and intensity-modulated radiation therapy (IMRT) for the treatment of prostate cancer. Methods and Materials: Eleven patients with prostate cancer treated at our institution were randomly selected for this study. For each patient, a VMAT plan and a series of IMRT plans using an increasing number of beams (8, 12, 16, 20, and 24 beams) were examined. All plans were generated using our in-house-developed automatic inverse planning (AIP) algorithm. An existing eight-beam clinical IMRT plan, which was used to treat the patient, was used as the reference plan. For each patient, all AIP-generated plans were optimized to achieve the same level of planning target volume (PTV) coverage as the reference plan. Plan quality was evaluated by measuring mean dose to and dose-volume statistics of the organs at risk, especially the rectum, from each type of plan. Results: For the same PTV coverage, the AIP-generated VMAT plans had significantly better plan quality in terms of rectum sparing than the eight-beam clinical and AIP-generated IMRT plans (p < 0.0001). However, the differences between the IMRT and VMAT plans in all the dosimetric indices decreased as the number of beams used in IMRT increased. IMRT plan quality was similar or superior to that of VMAT when the number of beams in IMRT was increased to a certain number, which ranged from 12 to 24 for the set of patients studied. The superior VMAT plan quality resulted in approximately 30% more monitor units than the eight-beam IMRT plans, but the delivery time was still less than 3 min. Conclusions: Considering the superior plan quality as well as the delivery efficiency of VMAT compared with that of IMRT, VMAT may be the preferred modality for treating prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated Volumetric Modulated Arc Therapy Treatment Planning for Stage III Lung Cancer: How Does It Compare With Intensity-Modulated Radio Therapy?

Purpose: To compare the quality of volumetric modulated arc therapy (VMAT) or intensity-modulated radiation therapy (IMRT) plans generated by an automated inverse planning system with that of dosimetrist-generated IMRT treatment plans for patients with stage III lung cancer. Methods and Materials: Two groups of 8 patients with stage III lung cancer were randomly selected. For group 1, the dosimetrists spent their best effort in designing IMRT plans to compete with the automated inverse planning system (mdaccAutoPlan); for group 2, the dosimetrists were not in competition and spent their regular effort. Five experienced radiation oncologists independently blind-reviewed and ranked the three plans for each patient: a rank of 1 was the best and 3 was the worst. Dosimetric measures were also performed to quantitatively evaluate the three types of plans. Results: Blind rankings from different oncologists were generally consistent. For group 1, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.6, 2.13, and 2.18, respectively. The auto-VMAT plans in group 1 had 10% higher planning tumor volume (PTV) conformality and 24% lower esophagus V70 (the volume receiving 70 Gy or more) than the manual IMRT plans; they also resulted in more than 20% higher complication-free tumor control probability (P+) than either type of IMRT plans. The auto- and manual IMRT plans in this group yielded generally comparable dosimetric measures. For group 2, the auto-VMAT, auto-IMRT, and manual IMRT plans received average ranks of 1.55, 1.75, and 2.75, respectively. Compared to the manual IMRT plans in this group, the auto-VMAT plans and auto-IMRT plans showed, respectively, 17% and 14% higher PTV dose conformality, 8% and 17% lower mean lung dose, 17% and 26% lower mean heart dose, and 36% and 23% higher P+. Conclusions: mdaccAutoPlan is capable of generating high-quality VMAT and IMRT treatment plans for stage III lung cancer. Manual IMRT plans could achieve quality similar to auto-IMRT plans if best effort was spent.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automatic planning on hippocampal avoidance whole-brain radiotherapy

Mounting evidence suggests that radiation-induced damage to the hippocampus plays a role in neurocognitive decline for patients receiving whole-brain radiotherapy (WBRT). Hippocampal avoidance whole-brain radiotherapy (HA-WBRT) has been proposed to reduce the putative neurocognitive deficits by limiting the dose to the hippocampus. However, urgency of palliation for patients as well as the complexities of the treatment planning may be barriers to protocol enrollment to accumulate further clinical evidence. This warrants expedited quality planning of HA-WBRT. Pinnacle{sup 3} Automatic treatment planning was designed to increase planning efficiency while maintaining or improving plan quality and consistency. The aim of the present study is to evaluate the performance of the Pinnacle{sup 3} Auto-Planning on HA-WBRT treatment planning. Ten patients previously treated for brain metastases were selected. Hippocampal volumes were contoured on T1 magnetic resonance (MR) images, and planning target volumes (PTVs) were generated based on RTOG0933. The following 2 types of plans were generated by Pinnacle{sup 3} Auto-Planning: the one with 2 coplanar volumetric modulated arc therapy (VMAT) arcs and the other with 9-field noncoplanar intensity-modulated radiation therapy (IMRT). D{sub 2%} and D{sub 98%} of PTV were used to calculate homogeneity index (HI). HI and Paddick Conformity index (CI) of PTV as well as D{sub 100%} and D{sub max} of the hippocampus were used to evaluate the plan quality. All the auto-plans met the dose coverage and constraint objectives based on RTOG0933. The auto-plans eliminated the necessity of generating pseudostructures by the planners, and it required little manual intervention which expedited the planning process. IMRT quality assurance (QA) results also suggest that all the auto-plans are practically acceptable on delivery. Pinnacle{sup 3} Auto-Planning generates acceptable plans by RTOG0933 criteria without time-consuming planning process. The expedited quality planning achieved by Auto-Planning (AP) may facilitate protocol enrollment of patients to further investigate the hippocampal-sparing effect and be used to ensure timely start of palliative treatment in future clinical practice.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-16A-01: Evolution of Radiation Treatment Planning

Welcome and Introduction - Lawrence N. Rothenberg This symposium is one a continuing series of presentations at AAPM Annual Meetings on the historical aspects of medical physics, radiology, and radiation oncology that have been organized by the AAPM History Committee. Information on previous presentations including “Early Developments in Teletherapy” (Indianapolis 2013), “Historical Aspects of Cross-Sectional Imaging” (Charlotte 2012), “Historical Aspects of Brachytherapy” (Vancouver 2011), “50 Years of Women in Medical Physics” (Houston 2008), and “Roentgen's Early Investigations” (Minneapolis 2007) can be found in the Education Section of the AAPM Website. The Austin 2014 History Symposium will be on “Evolution of Radiation Treatment Planning.” Overview - Radhe Mohan Treatment planning is one of the most critical components in the chain of radiation therapy of cancers. Treatment plans of today contain a wide variety of sophisticated information conveying the potential clinical effectiveness of the designed treatment to practitioners. Examples of such information include dose distributions superimposed on three- or even four-dimensional anatomic images; dose volume histograms, dose, dose-volume and dose-response indices for anatomic structures of interest; etc. These data are used for evaluating treatment plans and for making treatment decisions. The current state-of-the-art has evolved from the 1940s era when the dose to the tumor and normal tissues was estimated approximately by manual means. However, the symposium will cover the history of the field from the late-1950's, when computers were first introduced for treatment planning, to the present state involving the use of high performance computing and advanced multi-dimensional anatomic, functional and biological imaging, focusing only on external beam treatment planning. The symposium will start with a general overview of the treatment planning process including imaging, structure delineation, assignment of dose requirements, consideration of uncertainties, selection of beam configurations and shaping of beams, and calculations, optimization and evaluation of dose distributions. This will be followed by three presentations covering the evolution of treatment planning, which parallels the evolution of computers, availability of advanced volumetric imaging and the development of novel technologies such as dynamic multi-leaf collimators and online image guidance. This evolution will be divided over three distinct periods - prior to 1970's, the 2D era; from 1980 to the mid-1990's, the 3D era; and from the mid 1990's to today, the IMRT era. When the World was Flat: The Two-Dimensional Radiation Therapy Era” - Jacob Van Dyk In the 2D era, anatomy was defined with the aid of solder wires, special contouring devices and projection x-rays. Dose distributions were calculated manually from single field, flat surface isodoses on transparencies. Precalculated atlases of generic dose distributions were produced by the International Atomic Energy Agency. Massive time-shared main frames and mini-computers were used to compute doses at individual points or dose distributions in a single plane. Beam shapes were generally rectangular, with wedges, missing tissue compensators and occasional blocks to shield critical structures. Dose calculations were measurement-based or they used primary and scatter calculations based on scatter-air ratio methodologies. Dose distributions were displayed on line printers as alpha-numeric character maps or isodose patterns made with pen plotters. More than Pretty Pictures: 3D Treatment Planning and Conformal Therapy - Benedick A. Fraass The introduction of computed tomography allowed the delineation of anatomy three-dimensionally and, supported partly by contracts from the National Cancer Institute, made possible the introduction and clinical use of 3D treatment planning, leading to development and use of 3D conformal therapy in the 1980's. 3D computer graphics and 3D anatomical structure definitions made possible Beam's Eye View (BEV) displays, making conformal beam shaping and much more sophisticated beam arrangements possible. These conformal plans significantly improved target dose coverage as well as normal tissue sparing. The use of dose volume histograms, gross/clinical/planning target volumes, MRI and PET imaging, multileaf collimators, and computer-controlled treatment delivery made sophisticated planning approaches practical. The significant improvements in dose distributions and analysis achievable with 3D conformal therapy made possible formal dose escalation and normal tissue tolerance clinical studies that set new and improved expectations for improved local control and decreasing complications in many clinical sites. From the Art to the State of the Art: Inverse Planning and IMRT - Thomas R. Bortfeld While the potential of intensity modulation was recognized in the mid- 1980's, intensity-modulated radiotherapy (IMRT) did not become a reality until the mid-1990's. Broad beams of photons could be sub-divided into narrow beamlets whose intensities could be determined using sophisticated optimization algorithms to appropriately balance tumor dose with normal tissue sparing. The development of dynamic multi-leaf collimators (on conventional linear accelerators as well as in helical delivery devices) enabled the efficient delivery of IMRT. The evolution of IMRT planning is continuing in the form of Volumetric Modulated Arc Therapy (VMAT) and through advanced optimization tools, such as multi-criteria optimization, automated IMRT planning, and robust optimization to protect dose distributions against uncertainties. IMRT also facilitates “dose painting” in which different sub-volumes of the target are prescribed different doses. Clearly, these advancements are being made possible by the increasing power and lower cost of computers and developments in other fields such as imaging and operations research. Summary - Radhe Mohan The history does not end here. The advancement of treatment planning is expected to continue, leading to further automation and improvements in conformality and robustness of dose distributions, particularly in the area of particle therapy. Radiobiological modeling will gain emphasis as part of the planning process. Learning Objectives: The scope of changes in technology and the capabilities of radiation treatment planning The impact of these changes in the quality of treatment plans and optimality of dose distributions The impact of development in other fields (imaging, computers, operations research, etc.) on the evolution of radiation treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-E-T-97: An Analysis of Knowledge Based Planning for Stereotactic Body Radiation Therapy of the Spine

Purpose: Creating high quality SBRT treatment plans for the spine is often tedious and time consuming. In addition, the quality of treatment plans can vary greatly between treatment facilities due to inconsistencies in planning methods. This study investigates the performance of knowledge-based planning (KBP) for spine SBRT. Methods: Treatment plans were created for 28 spine SBRT patients. Each case was planned to meet strict dose objectives and guidelines. After physician and physicist approval, the plans were added to a custom model in a KBP system (RapidPlan, Varian Eclipse v13.5). The model was then trained to be able to predict estimated DVHs and provide starting objective functions for future patients based on both generated and manual objectives. To validate the model, ten additional spine SBRT cases were planned manually as well as using the model objectives. Plans were compared based on planning time and quality (ability to meet the plan objectives, including dose metrics and conformity). Results: The average dose to the spinal cord and the cord PRV differed between the validation and control plans by <0.25% demonstrating iso-toxicity. Six out of 10 validation plans met all dose objectives without the need for modifications, and overall, target dose coverage was increased by about 4.8%. If the validation plans did not meet the dose requirements initially, only 1–2 iterations of modifying the planning parameters were required before an acceptable plan was achieved. While manually created plans usually required 30 minutes to 3 hours to create, KBP can be used to create similar quality plans in 15–20 minutes. Conclusion: KBP for spinal tumors has shown to greatly decrease the amount of time required to achieve high quality treatment plans with minimal human intervention and could feasibly be used to standardize plan quality between institutions. Supported by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

SU-F-T-337: Accounting for Patient Motion During Volumetric Modulated Ac Therapy (VMAT) Planning for Post Mastectomy Chest Wall Irradiation

Purpose: To evaluate two dose optimization strategies for maintaining target volume coverage of inversely-planned post mastectomy radiotherapy (PMRT) plans during patient motion. Methods: Five patients previously treated with VMAT for PMRT at our clinical were randomly selected for this study. For each patient, two plan optimization strategies were compared. Plan 1 was optimized to a volume that included the physician’s planning target volume (PTV) plus an expansion up to 0.3 cm from the bolus surface. Plan 2 was optimized to the PTV plus an expansion up to 0.3 cm from the patient surface (i.e., not extending into the bolus). VMAT plans were optimized to deliver 95% of the prescription to 95% of the PTV while sparing organs at risk based on clinical dose limits. PTV coverage was then evaluated following the simulation of patient shifts by 1.0 cm in the anterior and posterior directions using the treatment planning system. Results: Posterior patient shifts produced a difference in D95% of around 11% in both planning approaches from the non-shifted dose distributions. Coverage of the medial and lateral borders of the evaluation volume was reduced in both the posteriorly shifted plans (Plan 1 and Plan 2). Anterior patient shifts affected Plan 2 more than Plan 1 with a difference in D95% of 1% for Plan 1 versus 6% for Plan 2 from the non-shifted dose distributions. The least variation in PTV dose homogeneity for both shifts was obtained with Plan 1. However, all posteriorly shifted plans failed to deliver 95% of the prescription to 95% of the PTV. Whereas, only a few anteriorly shifted plans failed this criteria. Conclusion: The results of this study suggest both planning volume methods are sensitive to patient motion, but that a PTV extended into a bolus volume is slightly more robust for anterior patient shifts.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP1-05: Development and Clinical Introduction of Automated Radiotherapy Treatment Planning for Prostate Cancer

Purpose: To develop an automated radiotherapy treatment planning and optimization workflow for prostate cancer in order to generate clinical treatment plans. Methods: A fully automated radiotherapy treatment planning and optimization workflow was developed based on the treatment planning system Monaco (Elekta AB, Stockholm, Sweden). To evaluate our method, a retrospective planning study (n=100) was performed on patients treated for prostate cancer with 5 field intensity modulated radiotherapy, receiving a dose of 35×2Gy to the prostate and vesicles and a simultaneous integrated boost of 35×0.2Gy to the prostate only. A comparison was made between the dosimetric values of the automatically and manually generated plans. Operator time to generate a plan and plan efficiency was measured. Results: A comparison of the dosimetric values show that automatically generated plans yield more beneficial dosimetric values. In automatic plans reductions of 43% in the V72Gy of the rectum and 13% in the V72Gy of the bladder are observed when compared to the manually generated plans. Smaller variance in dosimetric values is seen, i.e. the intra- and interplanner variability is decreased. For 97% of the automatically generated plans and 86% of the clinical plans all criteria for target coverage and organs at risk constraints are met. The amount of plan segments and monitor units is reduced by 13% and 9% respectively. Automated planning requires less than one minute of operator time compared to over an hour for manual planning. Conclusion: The automatically generated plans are highly suitable for clinical use. The plans have less variance and a large gain in time efficiency has been achieved. Currently, a pilot study is performed, comparing the preference of the clinician and clinical physicist for the automatic versus manual plan. Future work will include expanding our automated treatment planning method to other tumor sites and develop other automated radiotherapy workflows.

60 APPLIED LIFE SCIENCES↗

The Center Master Plan For NASA Glenn Research Center

The Center Master Plan for NASA Glenn Research Center is a comprehensive survey of NASA Glenn's current facility assets and a vision of how we see the facilities will change over the next 20 years in order to support the changing NASA Mission. This Center Master Plan is a vital management tool used by all organizations for making near term decisions and in future planning. During the summer of 2004, I worked with Joseph Morris, the Chief Architect in the Facilities Division, on beginning this Center Master Planning Process. The previous Master Plan was completed by the Center in 1985 and contained general information on the background of the facility as well as maps detailing environmental and historic records, land use, utilities, etc. The new Master Plan is required for the Center by NASA headquarters and will include similar types of information as used in the past. The new study will provide additional features including showing how individual buildings are linked to the programs and missions that they serve. The Master Plan will show practical future options for the facility s assets with a twenty year look ahead. The Plan will be electronically retrievable so that it becomes a communications tool for Center personnel. A Center Master Plan, although required, is very beneficial to NASA Glenn Research Center in aiding management with the future direction of the campus. Keeping up-to-date information and future plans readily available to all of NASA Glenn will insure that future real property development efficiently and effectively supports the missions camed out and supported by the Center. A Center Master Plan will also facilitate coordination with Center supported programs, stakeholders, and customers. In addition, it will provide a basis for cooperative planning with local and other governmental organizations and ultimately ensure that future budgets include the Center program needs described in the plan. This will ensure that development plans are safe, practical, and cost effective. To properly formulate any future plans, background information and research are required. Before bringing in a consultant to tackle the three year process anticipated to prepare a Center Master Plan, my job was to gather information on different organizations contributions to the NASA mission, their facility needs, consistent trends they observe, etc. I conducted numerous interviews with personnel such as Directorate Representatives, Division Chiefs, Branch Chiefs, System Managers and Building Managers. I documented the information I received from them for future use. I used the information to create various color-coded maps layering the different data. This was done with the ending objective being to collect the information and place it in a database that will be linked with Aperture (a computer program that generates color-coded map layers from database information) and made electronically retrievable to the Planning Consultant, NASA personnel, program stakeholders, and other governmental agencies. My goal this summer was to gather information and ideas appropriate for use in NASA Glenn Research Center s Master Plan and organize them for future application by the Planning Consultant. By the end of the summer, after completion of my goal, I will utilize my knowledge and create an array of preliminary future plans for the facility that can be passed along as a guidance tool.

Bigach, Kristin M.↗

Automation and Intensity Modulated Radiation Therapy for Individualized High-Quality Tangent Breast Treatment Plans

Purpose: To demonstrate the large-scale clinical implementation and performance of an automated treatment planning methodology for tangential breast intensity modulated radiation therapy (IMRT). Methods and Materials: Automated planning was used to prospectively plan tangential breast IMRT treatment for 1661 patients between June 2009 and November 2012. The automated planning method emulates the manual steps performed by the user during treatment planning, including anatomical segmentation, beam placement, optimization, dose calculation, and plan documentation. The user specifies clinical requirements of the plan to be generated through a user interface embedded in the planning system. The automated method uses heuristic algorithms to define and simplify the technical aspects of the treatment planning process. Results: Automated planning was used in 1661 of 1708 patients receiving tangential breast IMRT during the time interval studied. Therefore, automated planning was applicable in greater than 97% of cases. The time for treatment planning using the automated process is routinely 5 to 6 minutes on standard commercially available planning hardware. We have shown a consistent reduction in plan rejections from plan reviews through the standard quality control process or weekly quality review multidisciplinary breast rounds as we have automated the planning process for tangential breast IMRT. Clinical plan acceptance increased from 97.3% using our previous semiautomated inverse method to 98.9% using the fully automated method. Conclusions: Automation has become the routine standard method for treatment planning of tangential breast IMRT at our institution and is clinically feasible on a large scale. The method has wide clinical applicability and can add tremendous efficiency, standardization, and quality to the current treatment planning process. The use of automated methods can allow centers to more rapidly adopt IMRT and enhance access to the documented improvements in care for breast cancer patients, using technologies that are widely available and already in clinical use.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A planning study investigating dual-gated volumetric arc stereotactic treatment of primary renal cell carcinoma

This is a planning study investigating the dosimetric advantages of gated volumetric-modulated arc therapy (VMAT) to the end-exhale and end-inhale breathing phases for patients undergoing stereotactic treatment of primary renal cell carcinoma. VMAT plans were developed from the end-inhale (VMATinh) and the end-exhale (VMATexh) phases of the breathing cycle as well as a VMAT plan and 3-dimensional conformal radiation therapy plan based on an internal target volume (ITV) (VMATitv). An additional VMAT plan was created by giving the respective gated VMAT plan a 50% weighting and summing the inhale and exhale plans together to create a summed gated plan. Dose to organs at risk (OARs) as well as comparison of intermediate and low-dose conformity was evaluated. There was no difference in the volume of healthy tissue receiving the prescribed dose for the planned target volume (PTV) (CI100%) for all the VMAT plans; however, the mean volume of healthy tissue receiving 50% of the prescribed dose for the PTV (CI50%) values were 4.7 (± 0.2), 4.6 (± 0.2), and 4.7 (± 0.6) for the VMATitv, VMATinh, and VMATexh plans, respectively. The VMAT plans based on the exhale and inhale breathing phases showed a 4.8% and 2.4% reduction in dose to 30 cm{sup 3} of the small bowel, respectively, compared with that of the ITV-based VMAT plan. The summed gated VMAT plans showed a 6.2% reduction in dose to 30 cm{sup 3} of the small bowel compared with that of the VMAT plans based on the ITV. Additionally, when compared with the inhale and the exhale VMAT plans, a 4% and 1.5%, respectively, reduction was observed. Gating VMAT was able to reduce the amount of prescribed, intermediate, and integral dose to healthy tissue when compared with VMAT plans based on an ITV. When summing the inhale and exhale plans together, dose to healthy tissue and OARs was optimized. However, gating VMAT plans would take longer to treat and is a factor that needs to be considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-C-BRB-03: Cross-Institutional Validation of An Ultrafast Automatic Planning Platform for Breast Irradiation

Purpose: Recently an ultrafast automatic planning system for breast irradiation using tangential beams was developed by modeling relationships between patient anatomy and achieved dose distribution. This study evaluates the performance of this system when applied to a different patient population and dose calculation algorithm. Methods: The system and its anatomy-to-dose models was developed at institution A based on 20 cases, which were planned using manual fluence painting technique and calculated WITH heterogeneity correction. Institution B uses field-in-field planning technique and dose calculation WITHOUT heterogeneity correction. 11 breast cases treated at Institution B were randomly selected for retrospective study, including left and right sides, and different breast size (irradiated volumes defined by Jaw/MLC opening range from 875cc to 3516cc). Comparisons between plans generated automatically (Auto-Plans) and those used for treatment (Clinical-Plans) included: energy choice (single/mixed), volumes receiving 95%/100%/105%/110% Rx dose (V95%/V100%/V105%/V100%) relative to irradiated volume, D1cc, and LungV20Gy. Results: In 9 out of 11 cases single/mixed energy choice made by the software agreed with Clinical-Plans. For the remaining 2 cases software recommended using mixed energy and dosimetric improvements were observed. V100% were similar (p=0.223, Wilcoxon Signed-Rank test) between Auto-Plans and Clinical-Plans (57.6±8.9% vs. 54.8±9.5%). V95% is 2.3±3.0% higher for Auto-Plans (p=0.027), indicating reduced cold areas. Hot spot volume V105% were significantly reduced in Auto-Plan by 14.4±7.2% (p=0.004). Absolute V105% was reduced from 395.6±359.9cc for Clinical-Plans to 108.7±163cc for Auto-Plans. D1cc was 107.4±2.8% for Auto-Plans, and 109.2±2.4% for Clinical-Plans (p=0.056). LungV20Gy were 13.6±4.0% for Auto-Plan vs. 14.0±4.1% for Clinical-Plans (p=0.043). All optimizations were finished within 1.5min. Conclusion: The performance of this breast auto-planning system remained stable and satisfactory when applied to a different patient population and dose calculation algorithm. The auto-planning system was able to produce clinically similar Rx dose coverage with significantly improved homogeneity inside breast tissue, in less than 1.5min.

60 APPLIED LIFE SCIENCES↗

Robust Proton Pencil Beam Scanning Treatment Planning for Rectal Cancer Radiation Therapy

Purpose: To investigate, in a treatment plan design and robustness study, whether proton pencil beam scanning (PBS) has the potential to offer advantages, relative to interfraction uncertainties, over photon volumetric modulated arc therapy (VMAT) in a locally advanced rectal cancer patient population. Methods and Materials: Ten patients received a planning CT scan, followed by an average of 4 weekly offline CT verification CT scans, which were rigidly co-registered to the planning CT. Clinical PBS plans were generated on the planning CT, using a single-field uniform-dose technique with single-posterior and parallel-opposed (LAT) fields geometries. The VMAT plans were generated on the planning CT using 2 6-MV, 220° coplanar arcs. Clinical plans were forward-calculated on verification CTs to assess robustness relative to anatomic changes. Setup errors were assessed by forward-calculating clinical plans with a ±5-mm (left–right, anterior–posterior, superior–inferior) isocenter shift on the planning CT. Differences in clinical target volume and organ at risk dose–volume histogram (DHV) indicators between plans were tested for significance using an appropriate Wilcoxon test (P<.05). Results: Dosimetrically, PBS plans were statistically different from VMAT plans, showing greater organ at risk sparing. However, the bladder was statistically identical among LAT and VMAT plans. The clinical target volume coverage was statistically identical among all plans. The robustness test found that all DVH indicators for PBS and VMAT plans were robust, except the LAT's genitalia (V5, V35). The verification CT plans showed that all DVH indicators were robust. Conclusions: Pencil beam scanning plans were found to be as robust as VMAT plans relative to interfractional changes during treatment when posterior beam angles and appropriate range margins are used. Pencil beam scanning dosimetric gains in the bowel (V15, V20) over VMAT suggest that using PBS to treat rectal cancer may reduce radiation treatment–related toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Forward treatment planning for modulated electron radiotherapy (MERT) employing Monte Carlo methods

Purpose: This paper describes the development of a forward planning process for modulated electron radiotherapy (MERT). The approach is based on a previously developed electron beam model used to calculate dose distributions of electron beams shaped by a photon multi leaf collimator (pMLC). Methods: As the electron beam model has already been implemented into the Swiss Monte Carlo Plan environment, the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA) can be included in the planning process for MERT. In a first step, CT data are imported into Eclipse and a pMLC shaped electron beam is set up. This initial electron beam is then divided into segments, with the electron energy in each segment chosen according to the distal depth of the planning target volume (PTV) in beam direction. In order to improve the homogeneity of the dose distribution in the PTV, a feathering process (Gaussian edge feathering) is launched, which results in a number of feathered segments. For each of these segments a dose calculation is performed employing the in-house developed electron beam model along with the macro Monte Carlo dose calculation algorithm. Finally, an automated weight optimization of all segments is carried out and the total dose distribution is read back into Eclipse for display and evaluation. One academic and two clinical situations are investigated for possible benefits of MERT treatment compared to standard treatments performed in our clinics and treatment with a bolus electron conformal (BolusECT) method. Results: The MERT treatment plan of the academic case was superior to the standard single segment electron treatment plan in terms of organs at risk (OAR) sparing. Further, a comparison between an unfeathered and a feathered MERT plan showed better PTV coverage and homogeneity for the feathered plan, with V{sub 95%} increased from 90% to 96% and V{sub 107%} decreased from 8% to nearly 0%. For a clinical breast boost irradiation, the MERT plan led to a similar homogeneity in the PTV compared to the standard treatment plan while the mean body dose was lower for the MERT plan. Regarding the second clinical case, a whole breast treatment, MERT resulted in a reduction of the lung volume receiving more than 45% of the prescribed dose when compared to the standard plan. On the other hand, the MERT plan leads to a larger low-dose lung volume and a degraded dose homogeneity in the PTV. For the clinical cases evaluated in this work, treatment plans using the BolusECT technique resulted in a more homogenous PTV and CTV coverage but higher doses to the OARs than the MERT plans. Conclusions: MERT treatments were successfully planned for phantom and clinical cases, applying a newly developed intuitive and efficient forward planning strategy that employs a MC based electron beam model for pMLC shaped electron beams. It is shown that MERT can lead to a dose reduction in OARs compared to other methods. The process of feathering MERT segments results in an improvement of the dose homogeneity in the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗