Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV grid integration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

281 records · Page 16

Combined Cycle Integrated Thermal Energy Storage “CiTES” (Final Scientific/Technical Report)

The Phase I of this project confirmed the technical feasibility of a Combined Cycle integrated Thermal Energy Storage “CiTES” system, calculated the key performance parameters like power efficiency and costs, and proved its commercial value with full-year simulations for several US electricity markets with high degree of variable renewable generation and volatile hourly electricity prices. The core element of this project is the Electro Thermal Energy Storage (ETES) technology from Siemens Gamesa Renewable Energy GmbH, using thermally stable and inexpensive volcanic rocks as storage material and air as heat transfer medium. This technology is backed by more than 10 years of experience and a 440MMBTU (130MWh-th) pilot plant in Hamburg, Germany, which is in operation since 2019. The integration of this thermal storage in an existing combined cycle power plant (CCPP) is typical power plant technology without any major technology risks. It allows the storage of inexpensive renewable energy during times of surplus renewable generation and the discharge of this energy in times of high energy demand when the fossil plant is in operation. This supplements the fossil power generation with CO2-emission-free energy. The secondary effect of the CiTES system is that a small part of the stored thermal energy is used to keep the heat recovery steam generator (HRSG) and steam turbine (ST) of the combined cycle power plant in hot and ready-to-start condition. This enables the plant to start rapidly when fossil generation is required to satisfy demand as soon variable generation drops off in the evenings or during cloud cover and calm wind periods. Without pre-warming of the HRSG and ST, the CCPP would need several hours for a cold or warm start, burn a lot of gas and release high NOx emissions during start and wouldn’t be able to use the short times of high energy prices in an efficient or economical manner. The economic parameters of CiTES were determined by a full year “8760” simulation using a data set calculation for each of the hours of the year, and historical electricity and gas prices. For consistency, the simulations were focused on the pre-COVID year 2019. The financially most attractive markets were in the Energy Reliability Council of Texas (ERCOT) region, which allowed substantial value generation with arbitrage (charge with cheap energy during renewable surplus times and discharge when energy is needed and expensive). The improvement of flexibility with the CiTES system by pre-heating and warm-keeping of the CCPP allowed for additional power generation during short time periods when demand is high but renewable generation is down; when the hourly energy prices are highest in these markets. The simulations are based on 2019 data, when ERCOT had 27GW of installed photovoltaic (PV) and wind generation. They showed that the created revenue with the prototypically sized CiTES system of 1,000MMBTU (300MWh-th) falls a little bit short of what is expected from a commercially viable investment. The system has optimization opportunities for cost reduction and increased effectiveness which will be realized during a potential Phase II Pre-FEED study following this project. Furthermore, it is safe to assume that a lot of renewable generation capacity will be added all over the US in the coming years. As an example, ERCOT is predicting to more than double its renewable generation from 27GW in 2019 to a forecasted 63GW in 2023. This will increase the amount of renewable overproduction exponentially. This rapid increase of local overproduction and the need to curtail renewable generation is well documented by the California ISO (www.CAISO.com / managing oversupply). However, the simulations also revealed a weakness in the structure of the electricity markets in the US. More specifically, when electricity prices are very low and approaching negative levels, the owners of Variable Renewable Energy (VRE) will curtail a part of their facility to stabilize the price by reducing supply. This results in a situation in which storage facilities, which are integrated in existing fossil assets and don’t have the behind-the-meter benefit of a VRE, won’t be able to purchase low cost – otherwise curtailed – renewable energy off the grid. A special tariff, which motivates VRE owners to sell otherwise curtailed renewable energy to storage facilities (Hydrogen, thermal, pumped hydro, etc.) can solve this issue. The implementation of such a regulating tariff by Independent System Operators, thus avoiding renewable curtailment, is a pre condition for successful commercialization for renewable energy storage technologies. With this advancement of design and technology and improvements in the market environment, it can be expected that the Combined Cycle integrated Thermal Energy Storage proves itself as an important innovation to keep highly efficient, natural gas-based power generation economically successful and relevant for the power industry in the United States of America.

Wolf, Thorsten↗

Hybrid renewable energy systems: the value of storage as a function of PV-wind variability

As shares of variable renewable energy (VRE) on the electric grid increase, sources of grid flexibility will become increasingly important for maintaining the reliability and affordability of electricity supply. Lithium-ion battery energy storage has been identified as an important and cost-effective source of flexibility, both by itself and when coupled with VRE technologies like solar photovoltaics (PV) and wind. In this study, we explored the current and future value of utility-scale hybrid energy systems comprising PV, wind, and lithium-ion battery technologies (PV-wind-battery systems). Using a price-taker model with simulated hourly energy and capacity prices, we simulated the revenue-maximizing dispatch of a range of PV-wind-battery configurations across Texas, from the present through 2050. Holding PV capacity and point-of-interconnection capacity constant, we modeled configurations with varying wind-to-PV capacity ratios and battery-to-PV capacity ratios. We found that coupling PV, wind, and battery technologies allows for more effective utilization of interconnection capacity by increasing capacity factors to 60%–80%+ and capacity credits to close to 100%, depending on battery capacity. We also compared the energy and capacity values of PV-wind and PV-wind-battery systems to the corresponding stability coefficient metric, which describes the location-and configuration-specific complementarity of PV and wind resources. Our results show that the stability coefficient effectively predicts the configuration-location combinations in which a smaller battery component can provide comparable economic performance in a PV-wind-battery system (compared to a PV-battery system). These PV-wind-battery hybrids can help integrate more VRE by providing smoother, more predictable generation and greater flexibility.

14 SOLAR ENERGY↗

Techno-economic Analysis of the Cryogenic Flux Capacitor Compared to Other forms of Hydrogen Production and Storage

The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. The hydrogens storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (~1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 49% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at equivalent densities. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce GH2. The TEA compares pure hydrogen burning in a combined cycle gas turbine (CCGT) to hydrogen fuel cells with an overall net power output of 650 MW. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity is developed based on the capital cost and operating cost of the systems. Sensitivities are discussed around the cost of natural gas, ranging from 1.93 USD per MMBTU to 6.75 USD per MMBTU, and carbon dioxide disposal, ranging from 7 USD per tonne to 10 USD per tonne. For comparison to the conventional CCGT baseline, a baseload scenario is adopted with 85% capacity factor. The results of the study show that onsite hydrogen generation from SMR is about 1 to 3 USD per kg over the life of the plant and the PV hydrogen production produces at 4 to 5 USD per kg. The cost of storage for CFC is compared to other systems, including high-pressure GH2 and atmospheric LH2. The system is shown to provide the lowest costs for all these options at the grid scale, due to its higher capacity than high-pressure GH2 and ability to operate at 80K, receiving refrigeration from liquid nitrogen systems reducing capital and operating costs when compared LH2 storage systems. SMR is competitive with CCGT at the gas prices, both of which have lower LCOE than the PV system. When accounting for variability in gas prices, the PV and electrolyzer system is less sensitive to these changes and provides the lowest LCOE across the whole range.

08 HYDROGEN↗

Soft-Switching Solid-State Transformer With Reduced Conduction Loss

Solid-state transformers (SSTs) are a promising solution photovoltaic (PV), wind, traction, data center, battery energy storage system (BESS), and fast charging electric vehicle (EV) applications. The traditional SSTs are typically three-stage, i.e., hard-switching cascaded multilevel rectifiers and inverters with dual active bridge (DAB) converters, which leads to bulky passives, low efficiency, and high electromagnetic interference (EMI). This article proposes a new soft-switching solid-state transformer (S4T). The S4T has full-range zero-voltage switching (ZVS), electrolytic capacitor-less dc link, and controlled dv/dt, which reduces EMI. The S4T comprises two reverse-blocking current-source inverter (CSI) bridges, auxiliary branches for ZVS, and transformer magnetizing inductor as a reduced dc link with 60% ripple. Compared with the prior S4T, an effective change on the leakage inductance diode is made to reduce the number of the devices on the main power path by 20% for significant conduction loss saving and retain the same functionality of damping the resonance between the leakage and resonant capacitors and recycling trapped leakage energy. The conduction loss saving is crucial, being the dominating loss mechanism in SSTs. Importantly, the proposed single-stage SST not only holds the potential for high power density and high efficiency but also has full functionality, e.g., multiport dc loads integration, voltage regulation, and reactive power compensation, unlike the traditional single-stage matrix SST. The S4T can achieve single-stage isolated bidirectional dc–dc, ac–dc, dc–ac, or ac–ac conversion. It can also be configured input-series output-parallel (ISOP) in a modular way for medium-voltage (MV) grids. Hence, the S4T is a promising candidate for the SST. The full functionality, e.g., voltage buck–boost, multiport, etc., and the universality of the S4T for the dc–dc, dc–ac, and ac–ac conversion are verified through the simulations and experiments of two-port and three-port MV prototypes based on 3.3 kV SiC MOSFETs in dc–dc, dc–ac, and ac–ac modes at 2 kV.

14 SOLAR ENERGY↗

Real-time Simulation of Coordinated Sub-Transmission Volt-Var Control Tool under High Distributed PV Penetration

With the rapid penetration of intermittent solar photovoltaic (PV) and other distributed energy resources (DER) into the grid, and subsequent changes in power flow patterns in both distribution and sub-transmission, voltage regulation is becoming a major challenge. It is prudent to leverage PV and DER to provide ancillary services to the grid, such as voltage regulation. Recently, a quasi-static, coordinated real-time sub transmission volt-var control algorithm (CReST-VCT) was developed for voltage regulation under high PV penetration by dispatching the reactive power settings of the shunt devices and PV inverters. The algorithm was validated offline, on a quasistatic study. Such quasi-static dispatching algorithms cannot guarantee its performance for highly nonlinear dynamical power systems. In this paper the performance of the algorithm is validated with a real time nonlinear dynamic simulation of a modified IEEE 118 bus system in Opal-RT. The real time simulation is used to emulate the actual system operation, providing a more realistic testing environment for CReST-VCT. The dispatch and control signals are communicated between the power system (Opal solver) and the control center (GAMS solver) in real-time with a MODBUS bridge. The results demonstrate i) system is stable with the new dispatch points ii) significant improvement in system-wide voltage profiles compared to an uncontrolled scenario. Another significant contribution of the work is developing a framework for dispatchable, long duration dynamic simulations that can be leveraged for market/dispatch studies.

CReST-VCT, Opal-RT, Volt/Var Control, renewable in↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future

This report is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The main insights from this study can also help inform policy development and investment decisions.

08 HYDROGEN↗

Assessment of the polygeneration approach in wastewater treatment plants for enhanced energy efficiency and green hydrogen/ammonia production

Wastewater treatment plants (WWTPs) offer opportunities to optimize resource utilization and enhance energy efficiency. Here, this study provides a comprehensive analysis of using the polygeneration approach in WWTPs to reduce grid energy dependence, optimize energy distribution, and utilize surplus energy for hydrogen (H 2 ) and ammonia (NH 3 ) production. Several models were employed, including photovoltaic (PV) cells, parabolic trough collectors (PTCs), steam methane reforming, and polymer electrolyte membranes, to assess the feasibility of this approach. Three scenarios were evaluated and compared: Scenario 1 (Baseline) represents the current situation, Scenario 2 maximizes the Net Present Value (NPV), and Scenario 3 minimizes NH 3 production costs. Real data from As-Samra WWTP in Jordan was used to accurately assess the feasibility of each scenario. The results show that Scenario 2 offers the highest profitability and efficiency, with a NPV of 87.48 million USD and an annual NH 3 production of 15,417 tons, reducing both grid dependency and biogas fuel consumption. Both Scenarios 2 and 3 demonstrate the ability to meet thermal demands efficiently while generating significant revenue from NH 3 production. Scenario 3, in particular, achieves competitive H 2 and NH 3 production costs. Environmentally, Scenario 2 significantly reduces annual greenhouse gas emissions by 12.66 kilotons of CO 2eq , with near-zero carbon intensity for thermal energy due to solar reliance. In conclusion, the polygeneration approach offers a promising pathway for WWTPs to achieve greater sustainability, economic gains, and reduced environmental impact, providing valuable insights for decision-makers.

42 ENGINEERING↗

IBR Digital Supply Chain Gap Analysis and Recommendations

The adoption of clean energy technologies, including solar photovoltaics, continues to introduce non-traditional stakeholders to the operations and planning of the electric system. Stakeholders such as manufacturers, vendors, owners, aggregators, and others are enabling the adoption, integration, and optimum operations of solar technologies at accelerated rates. Inverters form the foundation of many digitally controlled energy sources for clean energy technologies, including Solar, Battery Energy Storage Systems, Hybrid Systems, and Hydrogen Fuel Cells. Their supply chain is complex, a series of microchips, electronic switches and other components making up its primary functions. The complexity of this space and the growing digitization associated with these components can create supply chain cyber risks. One measure to mitigate cybersecurity attacks is proper digital supply chain security. The U.S. Department of Energy (DOE) Solar Energy Technologies Office (SETO), in partnership with the Cybersecurity, Energy, Security, and Emergency Response (CESER) office, is hosting a workshop to bring together solar vendors and services providers to discuss digital supply chain security for solar systems and challenges and opportunities in the transitioning to a fully domestic supply chain for solar energy in the U.S. This workshop will support the Securing Solar for the Grid (S2G) and Energy Cyber Sense program activities. During the workshop, industry experts and researchers from DOE National Laboratories will discuss the current solar supply chain landscape and the transition to domestic manufacturing of solar components in the U.S. Tools and techniques to better manage and secure the digital supply chain of solar devices and systems will be discussed.

cybersecurity↗

New Industry Partnerships: Solar Energy Technologies Office Support for Early Projects in the Energy Systems Integration Facility: An Agreement Closeout Summary Report

The U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) Solar Energy Technologies Office (SETO)-funded New Industry Partnerships (NIPs) agreement established multiple new cooperative research projects with industry partners. Each project demonstrated the use of the National Renewable Energy Laboratory's Energy Systems Integration Facility (ESIF) as a national asset for research and development, testing, and validation of new technologies to support high penetrations of solar energy on the electric grid. The agreement was launched in 2013 and represented the SETO portion of the DOE EERE-wide Integrated Network Testbed for Energy Grid Research and Technology Experimentation (INTEGRATE) program. The focus of INTEGRATE was on multi-energy system testing and on testing the interactions of energy systems with information technology, communications, and telecommunications (ICT) systems. The NIPs agreement was a bit different from traditional research projects because it was specifically structured to enable partnerships for ESIF testing and as such required at least a 1:1 funds-in cost share from industry partners. In the end, the project engaged six different industry partnerships and resulted in testing a large number of innovative technologies. These included tiny inverters; power-to-gas technologies; and advanced simulation, analysis, and power-hardware-in-the-loop testing techniques. The agreement also provided significant impact for both research and industrial communities. This summary report provides a brief, high-level overview of these projects and their highlights along with lists of citations and other impacts. Readers are referred to the corresponding project reports for more in-depth information.

14 SOLAR ENERGY↗

Impacts of Renewable Energy and Green Hydrogen Policies on Uttar Pradesh's Power Sector Future: Additional Modeling Scenarios to Explore Hydrogen Flexibility [Slides]

This slide deck is part of a broader program focused on supporting Indian states with long-term power system planning. More information about this program can be found at the National Renewable Energy Laboratory's "Supporting India's States With Renewable Energy Integration" web page at https://www.nrel.gov/international/india-renewable-energy-integration.html. The power sector in Uttar Pradesh, India's most populous state, is poised to transform over the next few decades due to a combination of national and state-level policies impacting both the supply and demand of electricity. The Government of Uttar Pradesh has policies and plans to develop in-state solar PV, pumped storage hydropower, and green hydrogen. Power system policymakers and utilities in Uttar Pradesh are faced with the challenges of planning a system that incorporates increasing amounts of renewable energy and storage resources, meets rising electricity demand due to economic development and green hydrogen production, and satisfies operational and reliability requirements. To support these various objectives, the National Renewable Energy Laboratory (NREL), RMI, and the Uttar Pradesh New and Renewable Energy Development Agency (UPNEDA) evaluated the least-cost pathways for the state's power sector through 2050. NREL developed a capacity expansion model that identifies investment and operational decisions for every year (2024-2050) for all of India, with detailed representation for the state of Uttar Pradesh, which can provide a framework for recurring planning studies. The purpose of this slide deck is to supplement the main study (published in May 2024) with additional modeling scenarios to explore hydrogen flexibility.

08 HYDROGEN↗

Grid-Connected Modular Soft-Switching Solid State Transformers (M-S4T)

The objective of this project is to develop and verify the concept of a flexible and modular soft-switching solid-state transformer (M-S4T) for direct grid-connected applications. The ability to directly connect power electronics converters to the medium voltage grid (4 kV – 13 kV), and to potentially replace the passive and bulky, but ubiquitous 60 hertz service transformer in the 25 kVA to 100 kVA range, with a more flexible and controllable device, has been regarded as the ‘holy grail’ in grid control. However, this has proven to be extremely difficult. This project has developed the solutions to several key challenges of the direct grid-connected power electronics and realized a 7.2 kV M-S4T prototype. First, a protection method to protect the M-S4T from the high voltages (110 kV for the 13 kV system) that occur on the grid due to transients and lightning strikes have been developed and experimentally verified. Second, the realization and the operation of the M-S4T based on high-voltage SiC devices (>3.3 kV) and a medium-frequency medium-voltage low-leakage transformer in a single-stage solid-state transformer with zero-voltage switching, low dv/dt, and low electromagnetic interference has been successfully demonstrated up to 7.5 kV peak. Third, an oil-cooling system and stable communication and distributed control system for converter module voltage sharing have been developed and experimentally verified. The developed M-S4T has realized a modular universal high-performance power conversion system. This conversion system is scalable to different voltage and power levels and adaptable to four-quadrant bidirectional operation. Moreover, the use of passive cooling techniques meets the equipment life requirements, and the lightning protection scheme fulfills the basic insulation level specifications for direct grid connection. Such power conversion system opens up near-term opportunities, including energy storage, solar PV, or electric vehicle charging with significant cost and footprint savings. In the longer term, the possibility of replacing the utility distribution transformer with an M-S4T will be transformative for future distribution grids with a compact footprint and full controllability to enable high renewable energy and storage penetration. In addition to the main project, this report expands on the Plus-Up projected including as part of the main award. This project developed and demonstrated the technology for autonomous collaborative inverters that can be connected in an ad hoc manner to the grid. The aim of the project was to: (1) evaluate the existing techniques for grid-connected inverters and find their limitations; (2) develop detailed requirements for grid-connected inverters in the modern grid with millions of active nodes; (3) design a unified control strategy that brings more autonomy and intelligence to grid-connected inverters, and addresses parts of the issues with the existing techniques. The proposed technique, called UniCon, enables inverters to 1) connect/disconnect to/from the grid in an ad hoc manner; (2) work based on local sensing. Slow communication could be used for a more optimized behavior; (3) work automatically in both grid-forming/grid-following mode; (4) handle large disturbances, e.g., big load step and fault, in an oscillation-free manner; (5) work collaboratively with other inverters in steady-state and during transients. UniCon can be implemented in the middle-level control; hence it is agnostic to the vendor and to the implementation of the inner voltage/current and protection loops. Furthermore, a new synchronization scheme, based on deep learning, was developed that can extract the grid voltage phase and amplitude in a stable manner. The method is cheap to implement can improve the dynamic performance of the grid-connected inverters during fast transients, e.g., fault. The proposed control scheme was validated by (1) MATLAB/Simulink; (2) hardware-in-the-loop results, and; (3) experimental results using three inverters that form a microgrid in a down-scaled feeder. Lastly, both the M-S4T and UniCon have achieved promising tangible paths to markets. In the case of the M-S4T, the underlying technology — the Soft Switching Solid State Transformer (S4T) developed at the Georgia Tech Center for Distributed Energy (GT-CDE) has been licensed by GridBlock from the Georgia Tech Research Corporation, and GridBlock has been working with manufacturing partner Jabil (one of the largest US-based contract manufacturers) and system integrator Power Secure (largest deployer of microgrids in the US with 4.7 GW under management), to meet the strong initial demand. Similarly, GridBlock has an exclusive license to the UniCon technology, developed under this award by GT-CDE. The UniCon provides an intermediate control layer that enables the implementation of the higher-level ‘transactive’ control commands for the system. The architecture of the system - slow communications with the cloud for system optimization and setpoints, and the use of locally measured quantities for real-time control, provide a very robust and secure way of implementing a real-time must-run grid that is also secure and stable. This is a brand-new functionality that is critical for the future grid and key to GridBlock’s business model.

24 POWER TRANSMISSION AND DISTRIBUTION↗