Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

From IEC 61853 power measurements to PV system simulations.

The IEC 61853 PV module energy rating standard requires measuring module power (and hence efficiency) over a matrix of irradiance and temperature conditions. These matrix points represent nearly the full range of operating conditions encountered in the field in all but the most extreme locations, and create an opportunity to develop alternative approaches to existing modelssuch as the single-diode models and the Sandia Array Performance Modelfor calculating system performance. This report begins by discussing the bilinear interpolation and extrapolation method from IEC 61853-3, and then describes four existing model-based methods that could be used with matrix measurements. Then a new model is developed and all options are compared according to seven objective criteria using the matrix measurements of four PV modules of different technologies. The results show that the new model is an excellent candidate for launching power matrix-based PV system simulations.

14 SOLAR ENERGY↗

Clear-Sky Detection Using Time-Averaged, Tilted-Plane Data

A method is presented to detect clear-sky periods for plane-of-array, time-averaged irradiance data that is based on the algorithm originally described by Reno and Hansen. We show this new method improves the state-of-the-art by providing accurate detection at longer data intervals, and by detecting clear periods in plane-of-array data, which is novel. We illustrate how accurate determination of clear-sky conditions helps to eliminate data noise and bias in the assessment of long-term performance of PV plants.

clear-sky conditions↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Colloidal Quantum Dot Photovoltaics: Current Progress and Path to Gigawatt Scale Enabled by Smart Manufacturing

Colloidal quantum dots (QDs) have lately been pursued with intense vigor for optoelectronic applications such as photovoltaics (PV), flexible electronics, displays, mid-infrared photodetectors, lasers, and single-photon emitters. These nanometer-sized semiconducting crystals can be suitably mass-produced and size-tuned via cost-effective solution-based synthetic routes to operate in the quantum size confinement regime, endowing them with a wide array of exotic optical and electronic properties. While the first potential market entry could be in displays and in niche applications such as “internet-of-things”, ultimately, the technology has the potential to influence large-scale terrestrial power generation, because it is amenable to high-throughput synthesis from Earth-abundant materials and large-area solution-based coating techniques and can be air-stable. In this Review, we chronicle the recent advances that have propelled QD PV toward commercialization and highlight potential areas for further progress. We present an account of the material compositions being explored as QDs and their various benefits, major chemical passivation and doping strategies that have been developed to allay QD surface traps, and advanced device designs deployed to maximize charge extraction. We also discuss pathways to >20% efficient QD PV and describe recent advances in high-precision and autonomous synthesis of such materials. With recent demonstrations of scalable synthesis of high-quality QDs, smart manufacturing of QDs and QD solids, and fabrication of stable solar cells under ambient conditions, we suggest that the technology is on the road to achieving maturity and technological relevance and that gigawatt per year distributed panel production sites may be within reach.

14 SOLAR ENERGY↗

Acceleration Factors for Combined‐Accelerated Stress Testing of Photovoltaic Modules

Combined‐accelerated stress testing (C‐AST) is developed to establish the durability of photovoltaic (PV) products, including for degradation modes that are not a priori known or examined in standardized tests. C‐AST aims to comprehensively represent the sample, stress factors, and their combinations using levels at the statistical tails of the natural environment. Acceleration factors for relevant climate sequences within the C‐AST cycle with respect to the Florida USA climate are estimated for selected degradation mechanisms. It is found that for degradation of the outer backsheet polymer layer, the acceleration factor of the tropical climate sequence (the longest of the climate sequences) is f ( T , G ) = 17.3 with ultraviolet photodegradation; for polyethylene terephthalate hydrolysis (backsheets), f ( T , RH ) = 426; for electrochemical corrosion (PV cell), f ( I ) = 14.1; and for PbSn solder fatigue f (Δ T , r ( T )) = 17.3. Here, T is the module temperature, G is the broadband spectrum irradiance on the plane of array of the module, RH is the relative humidity on the module surface, I is the leakage current through the module packaging, and r ( T ), the number of temperature reversals. The methods discussed herein are generally applicable for evaluating acceleration factors in other accelerated test methods.

14 SOLAR ENERGY↗

Recent advances in GaAs/Ge solar cells

By growing the GaAs cell on a Ge substrate, the advantages of GaAs cells can be retained and the higher mechanical strength of the Ge makes larger, thinner GaAs cells possible. To conform to immediate user requirements, GaAs growth conditions were modified to eliminate the additional PV output at GaAs/Ge interface. To demonstrate acceptable cell manufacturing technology, the major areas in cell manufacture were analyzed and developed, and efficiency combined. Also the cells were successfully assembled on current lightweight arrays. The main areas of effort are discussed.

Chu, C. L.↗

Semiconductors: In Situ Processing of Photovoltaic Devices

The possible processing of semiconductor photovoltaic devices is discussed. The requirements for lunar PV cells is reviewed, and the key challenges involved in their manufacturing are investigated. A schematic diagram of a passivated emitter and rear cell (PERC) is presented. The possible fabrication of large photovoltaic arrays in space from lunar materials is also discussed.

Curreri, Peter A.↗

Evaluation of Models and Measurements to Estimate Solar Radiation for 1-Axis Tracking Modules at NREL’s SRRL

Solar radiation reaching photovoltaic (PV) modules on a 1-axis tracking system can be measured by reference cells or thermopiles. The former is often biased due to the reflection of solar radiation by the glass cover of the PV. The uncertainty can be moderated by applying a correction factor, as a function of solar incident angle and the refractive index of the glass, to the measurement. On the other hand, solar radiation on the inclined PV panels can be computed by transposition models using global horizontal irradiance (GHI) observations from thermopiles. This study examines the models and measurements to estimate solar radiation for 1-axis tracking modules at the National Renewable Energy Laboratory’s (NREL’s) Solar Radiation Research Laboratory (SRRL). The 1-minute plane-of-array (POA) irradiances from 2019 are computed using the observed GHIs and a transposition model developed by Perez et al. The POA irradiances are compared with the observation by an IMT reference cell and a Kipp & Zonen CM Pyranometer 22 (CMP22) thermopile. For the SRRL’s 1-axis tracking system with an annual solar energy of 2323.9 kWh/m 2 , the POA irradiance is overestimated by ~70 kWh/m 2 using the transposition model. This bias is reduced by more than 50% using the IMT measurements calibrated by a correction factor for a PV surface of antireflection coated glass.

POA irradiance↗

Utility-Scale Solar, 2021 Edition

Berkeley Labs "Utility-Scale Solar", 2021 Edition presents analysis of empirical plant-level data from the U.S. fleet of ground-mounted photovoltaic (PV), PV+battery, and concentrating solar-thermal power (CSP) plants with capacities exceeding 5 MWAC. While focused on key developments in 2020, this report explores trends in deployment, technology, capital and operating costs, capacity factors, the levelized cost of solar energy (LCOE), power purchase agreement (PPA) prices, wholesale market value, and interconnection queue data.

2021↗

Advanced Photovoltaic Module Characterization: Using Image Transformers for Current–Voltage Curve Prediction From Electroluminescence Images

Individual photovoltaic (PV) module health monitoring can be a daunting task for operation and maintenance of solar farms. Modules can be inspected through luminescence, thermal imaging, and current–voltage (I–V) curve analyzes for identification of damage and power loss. I–V curves provide easily interpretable data to determine module health as they directly provide electrical performance metrics. However, in order to obtain these curves, modules must be disconnected from the array and either removed to a solar simulator or characterized in situ with corrections for module temperature, the incident solar spectrum, and intensity. Luminescence or thermal images of a module are relatively easy to acquire in situ. Electroluminescence (EL) images highlight physical defects in the modules but do not provide easily interpretable features to correlate with electrical performance. This work presents a SWin transformer network to predict I–V curves for PV modules from their corresponding EL images. The predicted I–V curves allow the accurate prediction of the maximum power point (MPP), short-circuit current I sc , and open-circuit voltage V oc with a mean error less of than 1%. Comparing single diode model (SDM) parameters extracted from the predicted curves to those extracted from the true curves, the series resistance R s demonstrates a mean error of 5.19%, and the photocurrent I a mean error of 0.197%. The shunt resistance R sh and dark current Io parameters are predicted with larger errors because of their sensitivity to small changes in the I–V curve.

Byford, Brandon K. [New Mexico State Univ., Las Cr↗

Measuring Irradiance for Bifacial PV Systems

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

bifacial↗

Measuring Irradiance for Bifacial PV Systems: Preprint

The advent of bifacial PV systems drives new requirements for irradiance measurement at PV projects for monitoring and assessment purposes. While there are several approaches, there is still no uniform guidance for what irradiance parameters to measure and for the optimal selection and placement of irradiance sensors at bifacial arrays. Standards are emerging to address these topics but are not yet available. In this paper we review approaches to bifacial irradiance monitoring which are being discussed in the research literature and pursued in early systems, to provide a preliminary guide and framework for developers planning bifacial projects.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Feature review of photovoltaic modeling software utilizing blind performance assessment

While confidence in photovoltaic (PV) modeling software has always been essential, the rapid pace of new PV plant developments makes accuracy and credibility more critical than ever. Independent assessments, particularly through blind modeling comparisons, are therefore necessary to ensure unbiased benchmarking across PV modeling software. Previous studies have been limited by a narrow range of models compared, anonymized results, or system size. This study presents results from the first-ever onymous blind modeling comparison, evaluated using both lab- and utility-scale fixed-tilt, monofacial, south-facing systems at sub-hourly time intervals. Seven commercially used PV software tools were compared: 3E SynaptiQ, PlantPredict, PVsyst, RatedPower, SAM, SolarFarmer, and Solargis Evaluate. Predictions were submitted directly by software representatives, providing unique insights into each software’s implementation and resulting prediction behavior. Notable features, including plane-of-array (POA) transposition model, module temperature model, shading model, and performance model were analyzed and compared. Four summary tables compile these features of the software, serving as a resource to help users understand the methodological differences and select the most suitable software for their applications. The software tools show deviations from mean error in annual yield up to 2.5 % in the lab-scale system, increasing to 6.0 % for the utility-scale system. These differences arise from a combination of user decisions and the inherent behavior of the software, indicating the need for continuous and rigorous validation of modeling methods using these software tools against complex, real-world systems.

14 SOLAR ENERGY↗

Flat-plate module efficiency versus cost tradeoffs

The Five Year Research Plan energy cost methodology and in depth analyses based on the extensive data that are relevant to PV systems are used to facilitate the accomplishment of the $0.15/kWh energy cost goal. An equation is given for the five year energy cost methodology. The allocation guidelines are designed to be consistent with flat solar array (FSA) milestones for module cost, module efficiency, and the programmatic goal for energy cost. They are research targets that appear to be achievable, given prior accomplishments and planned activities in the areas of low cost silicon purification, low cost sheet material, high efficiency cell processing, low cost, long life encapsulants, and automated fabrication method. Extensive sensitivity analysis work has been performed that shows that these guidelines represent an efficient way to meet the intent of the DOE program.

Aster, R. W.↗

Processing Meteorological Data for the CAP-88 PC Model at Los Alamos National Laboratory

The Environmental Protection and Compliance-Compliance Programs (EPC-CP) group at Los Alamos National Laboratory (LANL) uses the Clean Air Act Assessment Package 1988 (CAP-88, Littleton 2020) PC model (Version 4.1) to estimate radiological doses for a set of areal sectors surrounding a release location, in order to satisfy the Environmental Protection Agency (EPA) National Emission Standards for Hazardous Air Pollutants (NESHAP) dose calculation requirement in 40 CFR 61 Subpart H. Among several types of data that must be prepared for CAP-88 input is a text file of meteorological data (“WIND” file), consisting of the joint frequency of wind direction, wind speed, and atmospheric stability categories. EPC-CP produces customized WIND files by running a CAP-88 utility program on a user generated text file of wind data in a different format, known as a STability ARray (STAR) file (Turner, 1964). At LANL, EPC-CP meteorologists prepare customized STAR files with data over desired time periods at selected meteorological towers. A custom program written in Precision Visuals -Workstation Analysis and Visualization Environment (PV-WAVE), a commercial Fortran-like language, is used to read LANL meteorological data and write a STAR file; the executable filename is “Star.out”. However, the outdated PV-WAVE utility program is being phased out by EPC-CP, due to the inefficient process to run it and an inability to modify the code. To preserve the ability to create customized meteorological data for CAP-88 in a way that will be easy to use and maintain, a new replacement utility program, written in the Python programming language, has been developed. The new, improved program reads a data file from any LANL meteorological tower, and at each desired observation time, determines the wind direction, wind speed, and stability categories defined in the CAP-88 documentation. The frequencies of all combinations of the three sets of categories are calculated and written to a file in the STAR format, which can later be converted to a WIND file for input into CAP-88.

54 ENVIRONMENTAL SCIENCES↗

Electrical power system WP-04

Viewgraphs on Space Station Freedom Electrical Power System (EPS) WP-40 are presented. Topics covered include: key EPS technical requirements; photovoltaic power module systems; solar array assembly; blanket containment box and box positioning subassemblies; solar cell; bypass diode assembly; Kapton with atomic oxygen resistant coating; sequential shunt unit; gimbal assembly; energy storage subsystem; thermal control subsystem; direct current switching unit; integrated equipment assembly; PV cargo element; PMAD system; and PMC and AC architecture.

Nored, Donald L.↗

Sample IEEE123 Bus system for OEDI SI

Time series load and PV data from an IEEE123 bus system. An example electrical system, named the OEDI SI feeder, is used to test the workflow in a co-simulation. The system used is the IEEE123 test system, which is a well studied test system (see link below to IEEE PES Test Feeder), but some modifications were made to it to add some solar power modules and measurements on the system. The aim of this project is to create an easy-to-use platform where various types of analytics can be performed on a wide range of electrical grid datasets. The aim is to establish an open-source library of algorithms that universities, national labs and other developers can contribute to which can be used on both open-source and proprietary grid data to improve the analysis of electrical distribution systems for the grid modeling community. OEDI Systems Integration (SI) is a grid algorithms and data analytics API created to standardize how data is sent between different modules that are run as part of a co-simulation. The readme file included in the S3 bucket provides information about the directory structure and how to use the algorithms. The sensors.json file is used to define the measurement locations.

123 bus↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗