Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE GAUGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparisons Between Pretest Prediction and Flight Test Data of Aerodynamic Loading for EFT-1

Exploration Flight Test One (EFT-1) was an incredible milestone in the development NASA's Orion spacecraft. It incorporated hundreds of articles of flight test instrumentation and returned with a wealth of data. Aerodynamic surface pressures were collected during launch vehicle ascent and capsule reentry and descent. These discrete surface pressure measurements enable comparisons to computational results and ground test data. This paper details the comparisons between pre-test predictions and flight test data for the Orion MPCV Crew Module (CM) and Launch Abort Tower (LAT) during all phases of flight. Regions with strong comparisons, poor predictions, and lessons learned are discussed. 38 pressure measurements were made on the LAT during ascent. Nine of the gauges were Honeywell PPTs and the remainder were Kulite pressure transducers. In order to address bias in the Kulites, a two-point linear calibration was used and the details are discussed. Results from the flight are compared to existing database products. 44 pressure measurements were made on the CM during reentry and descent. Nine of the gauges were Honeywell PPTs and the remainder were Kulite pressure transducers. In order to address bias in the Kulites, a tare was made against the vacuum measurements as described below. Once the bias was removed from the gauges, comparisons between predicted loading and the measured results are compared.

Schwing, Alan M.↗

Calibration stability of some hot-cathode ion gauges

Data are presented on the stability of calibration of some hot-cathode ion gauges: a conventional triode used in the range of 0.0002-0.2 Pa, and Bayard-Alpert-type gauges used in the range of 0.0002-0.02 Pa. Numerical magnitudes are given of the systematic corrections that must be applied to the gauge indication in order to achieve the highest accuracy of pressure indication. The relative sensitivities of these gauges to Ar, N2, Ne, and He are also given.

Warshawsky, I.↗

Mars Entry, Descent, and Landing Instrumentation 2 Trajectory, Aerodynamics, and Atmosphere Reconstruction

On February 18th, 2021, the Mars 2020 entry system successfully delivered the Perseverance rover to the surface of Mars at Jezero Crater. The entry capsule carried a set of instrumentation installed on the heat shield and backshell, named the Mars Entry, Descent, and Landing Instrumentation 2. The instruments include pressure transducers, thermocouples, heat flux gauges, and radiometers to measure the aerodynamic and aerothermodynamic performance of the entry vehicle. This paper describes the trajectory and atmosphere reconstruction results based on the pressure sensor measurements. The process uses a Kalman filter approach to estimate the freestream atmospheric properties from the pressure measurements combined with a model of the pressure distribution of the heatshield and other sensor inputs, including an inertial measurement unit and other on-board navigation sensors, and several external atmospheric observations. The results indicate upper altitude density was up to 150% higher than nominal, which is consistent with the observed early entry guidance start time. The density below 40 km was within 12% the pre-flight predictions. The reconstructed axial force coefficient was approximately 2% lower than the pre-flight prediction across the flight range.

Christopher D Karlgaard↗

Piston manometer as an absolute standard for vacuum-gauge calibration.

Determination of the total pressure in a calibration volume by measuring the force on a thin circular disk, of accurately known area, that is freely suspended in a hole in the container wall, so that the disk is substantially flush with the wall. The disk almost fills the hole, so that there is a narrow annular gap. A continuous flow of calibrating gas, injected into the container in order to maintain a desired pressure, passes through the annular gap to a diffusion pump. The ratio of pressures on the two faces of the disk is of the order of 100:1, so that downstream pressure need be known only nominally in order to deduce the upstream surface. Force on the disk is measured by a balance that is calibrated in situ with dead weights. In one arrangement, pressures in the range from 10 to 500 microtorr were measured with an estimated probable error of (1 microtorr + 1%).

Warshawsky, I.↗

Investigation of the Neutral Gas Pressure Effect on the Metal Resistive Bolometer

The bolometer system planned for W7-X consists mainly of metal (Au) resistive detector arrays. All the detectors are exposed to neutral gas environment. The thin bolometer foil used for detecting the radiated power loss may be sensitive to the neutral gas pressure due to the strain gauge effect. Recently, a prototype of this kind of bolometer camera consisting of 12 channels has been installed on the cylindrical plasma device VINETA in order to investigate the influences of the neutral gas pressure on the bolometer signals. Experiments are carried out for Ar-discharges under different gas pressure conditions. It is found that the pressure effect of the neutral gas can make considerable contributions, thus inducing non-negligible errors of the results in most of the investigated cases. Using the VINETA plasmas (Ar, T{sub e}<10 eV, n{sub e}<10{sup -19} m{sup -3}) as examples, the paper demonstrates and discusses how to minimize the neutral gas effects, especially in the data analysis process. The radiated power and the radiation intensity profile obtained in helicon discharges are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fully nonlinear and exact perturbations of the Friedmann world model: non-flat background

We extend the fully non-linear and exact cosmological perturbation equations in a Friedmann background universe to include the background curvature. The perturbation equations are presented in a gauge ready form, so any temporal gauge condition can be adopted freely depending on the problem to be solved. We consider the scalar, and vector perturbations without anisotropic stress. As an application, we analyze the equations in the special case of irrotational zero-pressure fluid in the comoving gauge condition. We also present the fully nonlinear formulation for a minimally coupled scalar field.

79 ASTRONOMY AND ASTROPHYSICS↗

Development and Design of a Zero-G Liquid Quantity Gauge for a Solar Thermal Vehicle

The development and design of a cryogenic liquid quantity gauge for zero-g applications is described. The gauge, named the Compression Mass Gauge (CMG), operates on the principle of slightly changing the volume of the tank by an oscillating bellows. The resulting pressure change is measured and used to predict the volume of vapor in the tank, from which the volume of liquid is computed. For each gauging instance, pressures are measured for several different bellows frequencies to enable minor real-gas effects to be quantified and thereby to obtain a gauging accuracy of +/- 1% of tank volume. Southwest Research Institute (Tm) and NASA-GRC (Glenn Research Center) have developed several previous breadboard and engineering development gauges and tested them in cryogenic hydrogen and nitrogen to establish the gauge capabilities, to resolve several design issues, and to formulate data processing algorithms. The CMG has been selected by NASA's Future X program for a flight demonstration on the USAF (United States Air Force) / Boeing Solar Thermal Vehicle Space Experiment (SOTVSE). This paper reviews the design trade studies needed to satisfy the SOTVSE limitations on CMG power, volume, and mass, and describes the mechanical design of the CMG.

Dodge, Franklin T.↗

Development and Design of Zero-g Liquid Quantity Gauge for Solar Thermal Vehicle

The development and design of a cryogenic liquid quantity gauge for zero-gravity (zero-g) applications are described. The gauge, named the compression mass gauge (CMG), operates on the principle of slightly changing the volume of the tank by an oscillating bellows. The resulting pressure change is measured and used to predict the volume of vapor in the tank, from which the volume of liquid is computed. For each gauging instance, pressures are measured for several different bellows frequencies to enable minor real-gas effects to be quantified and thereby to obtain a gauging accuracy of 11 percent of tank volume. The CMG has been selected by NASA's Future-X program for a flight demonstration on the United States Air Force-Boeing Solar Orbit Transfer Vehicle Space Experiment (SOTVSE). This report reviews the design trade studies needed for the CMG to satisfy the SOTVSE limitations on its power, volume, and mass and also describes the mechanical design of the CMG.

Dodge, Franklin T.↗

The study of pressure measurement techniques and devices in the range of 10(exp -1) to 10(exp -5) torr (2 millipsi to 0.2 micropsi)

The atmospheric pressure range was studied in a region where conventional pressure sensing devices do not provide meaningful measurements. However, a hot filament gauge was developed and miniaturized which will measure the pressure in the 10(exp -1) to 10(exp -5) torr (2 millipsi to 0.2 micropsi) region, hence the name Micropsi gauge. Laboratory studies were made comparing the currently available devices with the newly developed miniature low power 'Micropsi' pressure sensor.

Hoffman, John H.↗

Groundwater and surface water head from 2019 to 2022 at the Tims Branch in Savannah River Site (SRS), South Carolina.

This dataset contains groundwater and surface water head measurements for investigating hydro-biogeochemical processes in Tims Branch at the Savannah River Site, SC. Water levels were monitored using pressure transducers installed in surface water gauges and piezometers across three subsites in Tims Branch, identified as Wfloc, Snon (Snon1 and Snon2), and Sfloc. A barometric pressure logger was deployed in piezometers to correct pressure transducers from atmospheric pressure. Manual water level measurements were taken to calibrate transducer data. The dataset consists of at least paired groundwater and surface water head time series for each subsite, provided as individual CSV files. These data support analyses of surface-groundwater interactions, hydrologic controls on redox processes, and broader synthesis of wetland hydrology at the Savannah River Site.

ESS-DIVE CSV File Formatting Guidelines Reporting ↗

Preliminary Findings of the Experimental Development Unit Cold Flow Test for a Generation Zero Nuclear Propulsion Engine

Nuclear thermal propulsion (NTP) technology will greatly benefit human travel to Mars by significantly shortening transit times, improving crew safety, and providing more mission flexibility than traditional chemical rockets. As part of DRACO follow-on work to develop, build, and fly a generation zero NTP engine, a full scale flight-like experimental design unit (EDU) reactor was constructed to collect sufficient on-ground performance data to characterize flow induced vibrations (FIV) of critical reactor structures/components, inform development of the engine and reactor control algorithm, and collect pressure drop and flow distribution data across the reactor. The fluid conditions for the test program were designed to achieve system responses equivalent to that of an operational engine through all phases of engine operation including reactor startup, mainstage operation, reactor shutdown, and reactor cooldown. Over 100 tests were executed, flowing either GN2 or GHe through the EDU at varying flow rates and pressures. This experiment provided early validation of flow behavior and vibration risks before nuclear testing, boosted critical subsystem TRLs, informed design iterations, and reduced future test costs. The steady-state flow parameters for the experiment were modeled in Ansys Thermal Desktop, allowing rapid tuning and experiment-informed updates to a flight-like test matrix. The EDU dynamic environment was characterized with accelerometers, strain gauges, and high-frequency pressure transducers all sampled at 20 kHz. While many narrow-band oscillations were identified, no significant FIV occurred; the reactor structural responses tend to be enveloped by typical launch vehicle ascent vibration environments (defined up to 2 kHz), although significant energy is also present at higher frequencies.

Flow Induced Vibration↗

Shock and Release Response of Unreacted Epon 828: Shot 2s-905

This document summarizes the shock and release response of Epon 828 measured in the dynamic impact experiment 2s-905. Experimentally, a thin Kel-F impactor backed by a low impedance foam impacted an Epon 828 target with embedded electromagnetic gauges. Computationally, a one dimensional simulation of the impact event was performed, and tracer particles were located at the corresponding electromagnetic gauge locations. The experimental configuration was such that the Epon 828 target was initially shocked, and then allowed to release from the high-pressure state. Comparisons of the experimental gauge and computational tracer data were made to assess the performance of equation of state (EOS) 7603, a SESAME EOS for Epon 828, on and off the principal shock Hugoniot. Results indicate that while EOS 7603 can capture the Hugoniot response to better that 1%, while the sound speeds at pressure are under-predicted by 6 - 7%.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Development and validation of a radial inflow turbine model for simulation of the SNL S-CO 2 split-flow loop

A one-dimensional model for a radial inflow turbine has been developed for super-critical carbon dioxide (S-CO 2 ) Brayton cycle applications. The model accounts for the main phenomena present in the volute, nozzle, and impeller of a single-stage turbine. These phenomena include internal losses due to friction, blade loading, and angle of incidence and parasitic losses due to windage and blade-housing leakage. The model has been added as a component to the G-PASS plant systems code. The model was developed to support the analysis of S-CO 2 cycles in conjunction with small-scale loop experiments. Such loops operate at less than a MWt thermal input. Their size permits components to be reconfigured in new arrangements relatively easily and economically. However, the small thermal input combined with the properties of carbon dioxide lead to turbomachines with impeller diameters of only one to two inches. At these sizes the dominant phenomena differ from those in larger more typical machines. There is almost no treatment in the literature of turbomachines at these sizes. The present work therefore is aimed at developing turbomachine models that support the task of S-CO 2 cycle analysis using small-scale tests. Model predictions were compared against data from an experiment performed for Sandia National Laboratories in the split-flow Brayton cycle loop currently located at Barber-Nichols Inc. The split-flow loop incorporates two turbo-alternator-compressor (TAC) units each incorporating a radial inflow turbine and a radial flow compressor on a common shaft. The predicted thermodynamic conditions at the outlet of the turbine on the main compressor shaft were compared with measured values at different shaft speeds. Two modifications to the original model were needed to better match the experiment data. First, a representation of the heat loss from the volute downstream of the sensed inlet temperature was added. Second, an empirical multiplicative factor was applied to the Euler head and another to the head loss to bring the predicted outlet pressure into better agreement with the experiment. These changes also brought the overall efficiency of the turbine into agreement with values cited by Barber Nichols for small turbines. More generally, the quality of measurement set data can in the future be improved by additional steps taken in the design and operation of the experimental apparatus. First, a thermocouple mounted at the nozzle inlet would provide a better indication of temperature at this key point. Second, heat losses from the turbine should be measured directly. Allowing the impeller to free wheel at inlet conditions and measuring the temperature drop between inlet and outlet would provide a more accurate measure of heat loss. Finally, the enthalpy change during operation is more accurately obtained by measuring the torque on the stator using strain gauges rather than by measuring pressure and temperature at inlet and outlet to infer thermodynamic states.

42 ENGINEERING↗

N.A.C.A. Langley Field Wind Tunnel Apparatusthe Tilting Manometer

A description is given of a tilting manometer designed to meet the requirements of a manometer for use in the wind tunnel at the Langley Memorial Aeronautical Laboratory. This gauge was designed to meet the requirements of a manometer in use in connection with a static pressure plate to indicate the wind speed in the tunnel. The requirements are noted. The sensitivity of the gauge must be made inversely proportional to the pressure to be measured. The gauge must be accurately and quickly set for any desired pressure. When set at the desired pressure, the extent of variation between the existing and the desired pressures may be readily estimated. In fact, this manometer is quick to adjust, is easy to read, always has the meniscus in the same position, and accurately indicates a large range of air speeds on what is a comparatively compact instrument.

Norton, F H↗

The pressure multiplier revisited

Pressure multipliers, which were originally intended to continuously sample an unknown pressure and increase it by a known factor, so that measurements could be conducted at low pressures with liquid-in-gas gauges, may be usefully applied to the increasing number of components available for use in molecular flow networks. An intriguing possibility involves the electric control of pressure multiplier gain by means of a piezoelectric valve.

Kendall, B. R. F.↗

Complete Fiber/Copper Cable Solution for Long-Term Temperature and Pressure Measurement in Supercritical Reservoirs and EGS Wells

High Temperature insulated wire and optical fiber cable is a key enabling technology for the Geothermal Technologies Program (GTP). Without insulated electrical wires and optical fiber, downhole temperature and pressure sensors, flow meters and gauges cannot communicate with the surface. Unfortunately, there are currently no insulated electrical wire or fiber cable constructions capable of surviving for extended periods of deployment in a geothermal well (240-325°C) or supercritical (374°C) reservoir. This has severely hindered engineered reservoir creation, management and utilization, as hot zones and cool water intrusions cannot be understood over time. The lack of a insulated electrical wire and fiber cable solution is a fundamental limitation to the viability of this energy source. The High Temperature Downhole Tools target specification is development of tools and sensors for logging and monitoring wellbore conditions at depths of up to 10,000 meters and temperatures up to 374oC. It well recognized in the industry that no current electronic or fiber cable can be successfully deployed in a well and function successfully for more a few days at temperatures over 240oC. The goal of this project was to raise this performance level significantly. Prysmian Group’s objective in this project was to develop a complete, multi-purpose cable solution for long-term deployment in geothermal wells/reservoirs that can be used with the widest variety of sensors. In particular, the overall project objective was to produce a manufacturable cable design that can perform without serious degradation: • At temperatures up to 374°C; • At pressures up to 220 bar; • In a hydrogen-rich environment; and • For the life of the well (> 5 years). This cable incorporates: • Specialty optical fibers, with specific glass chemistry and high temperature and pressure protective coatings for data communication and distributed temperature and pressure sensing, and • High-temperature insulated wire conductors Prysmian Group has developed a geothermal fiber optic cable (GFOC) solution which incorporates novel glass chemistry for optical fibers to operate at the required bandwidths in high temperature/high pressure hydrogen rich environments with fiber protection, high temperature insulated conductors and protective cladding for cable components. The cable solution has been tested in a geothermal installation for 10 months. The electrical insulation and optical fibers have been validated through laboratory testing to ensure successful operation for greater than 5 years at 300°C, with the possibility of higher temperatures depending on the particular well environment. With the 300°C optical fiber and electrical insulation developments completed and validated in laboratory tests the greatest challenge to a complete 300°C cable solution was protecting the optical fibers in the cable. Optical fibers are typically incased in a protective tube where the tube is filled with a gel. The gel serves as mechanical protection, prevent moisture ingress, and can include hydrogen scavenging materials. A suitable gel for use at 300°C could not be identified and an industrialized alternative was not fully attained. Despite the problems encountered and the lower long-term operating temperature of the cable solution, the project showed success in developing a complete cable solution for a large portion of the geothermal wells in operation today. Further work to obtain the higher long-term temperature goal of the project can be achieved based on the knowledge gained in the current project. This project is significant for many reasons including the new materials science, manufacturing technology, energy independence, and jobs created and will create.

15 GEOTHERMAL ENERGY↗