Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRESSURE DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Demonstration of RELAP5-3D for transient analysis of a dual coolant lead lithium fusion blanket concept

Our research aims to build a multiphysics framework for transient analysis of the Dual- Coolant Lead-Lithium (DCLL) blanket design of the proposed Fusion Nuclear Science Facility (FNSF) for all Onticipated Operational Occurrences (AOOs) using Reduced Order Models (ROMs). This paper presents an assessment of using RELAP5-3D for transient thermal-hydraulic blanket analysis of the DCLL design. Preliminary validation studies for the RELAP5-3D properties were conducted using a representative vertical flow loop model and a comparison study using experimental data from the thermal convection corrosion loops at ORNL. These studies inspected the thermal hydraulic response of Lead-Lithium Eutectic (PbLi) systems within the RELAP5-3D code; mainly pressure drop and heat transfer, as compared to analytical calculations and experimental data. The Magnetohydrodynamic (MHD) pressure drop effect for liquid metal under the effects of a uniform magnetic field was implemented into our models using an equivalent forms loss coefficient based on the phasic momentum equations. We verified our implementation of MHD pressure drop within RELAP5-3D using a systematic approach consisting of two studies. Models were developed to perform comparison studies based on experimental data from the Argonne Liquid metal EXperiment (ALEX) facility and the Magnetohydrodynamic PbLi Experiment (MaPLE) facility. Using the developed validation basis, we built a simplified DCLL channel model within RELAP5-3D, inspected MHD pressure drop and performed transient temperature analysis. The DCLL channel model used radial heating data from the International Thermonuclear Experimental Reactor (ITER) which was normalized to the FNSF design. Here, a representative startup transient was performed using a relative power curve from the initial ramp up of a long-term power pulse of the Tore Supra reactor. This study demonstrated that RELAP5-3D ROMs are capable of accurate transient analysis of the DCLL blanket. We have since utilized MCNP to develop heating profiles based on the FNSF design and are working toward implementing them into our DCLL model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary modeling of triply periodic minimal surface (TPMS) structures using RELAP5-3D

With the United States Department of Energy (DOE)’s goal of quadrupling the nation’s nuclear energy supply by 2050, and with the Advanced Fuels Campaign pushing for new types of advanced reactor fuels and geometries, the need has arisen for new nuclear fuel designs. One such design is to swap out current nuclear fuel geometries in exchange for another type of geometry, called a Triply Periodic Minimal Surface (TPMS). TPMSs are self-supporting, infinitely repeating lattices—attributes that lend themselves well to additive manufacturing. These surfaces also possess enhanced heat transfer properties thanks to their internal area changes and large surface-area-to-volume ratios. Their drawback, however, is an increased pressure drop. Given the small amount of correlations and data (Reynolds numbers in the 2,000–8,000 range), and the minimal amount of experience so far obtained by modeling TPMS structures using 1D systems codes such as the Reactor Excursion and Leak Analysis Program (RELAP5-3D), further research into this topic was needed. Using data from the University of Wisconsin - Madison (UW), curve fits were created for both a Heat Transfer Coefficient (HTC) correlation and a Darcy friction factor empirical coefficient correlation. The curves’ coefficients and multipliers were then output and utilized in RELAP5-3D models of two upcoming experiments—Flow Loop for INFLUX Pressure drop (FLIP) and Microreactor Agile Non-nuclear Experimental Test (MAGNET)—aimed at increasing the available data for Reynolds numbers to the 16,000–36,000 range for TPMS structures. The models were run under the conditions utilized by a Computational Fluid Dynamics (CFD) analysis performed by another group at Idaho National Laboratory. Only CFD pressure drop values were obtained from the FLIP test, and those values showed that the RELAP5-3D models had a lower rate of pressure increase in comparison to the CFD values. In addition, there seemed to be a vertical shift upward in the pressure drop for both models whenever the TPMS porosity decreased, and the RELAP5-3D models showed a higher vertical shift in comparison to the CFD values. The MAGNET results did not correspond to any CFD or experimental results against which they could be compared, so they were instead compared against the proposed CFD input conditions. These values were then compared with each other to make sure the model seemed to be performing as expected, paving the way for future tests that can be run for the purpose of further analyses and comparisons. The pressure drop increased with temperature and mass flow rate independently. The temperature change would decrease with increasing mass flow rate and temperature, which was just as we expected based on the fact that the lower viscosity and decreased density would result in higher friction and churning losses. The last metric that was assessed was the enthalpy flow change, which increased with increasing mass flow rate and decreasing temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of Pulsed Electrical Fields for Advanced Cooling and Water Recovery in Coal-Fired Power Plant

The overall objective of the present work was to develop technologies to reduce freshwater consumption in a cooling tower of coal-based power plant so that one could significantly reduce the need of make-up water. The specific goal was to develop a scale prevention technology based an integrated system of physical water treatment (PWT) and a novel filtration method so that one could reduce the need for the water blowdown, which accounts approximately 30% of water loss in a cooling tower. The present study investigated if a pulsed spark discharge in water could be used to remove deposits from the filter membrane. The test setup included a circulating water loop and a pulsed power system. The present experiments used artificially hardened water with hardness of 1,000 mg/L of CaCO{sub 3} made from a mixture of calcium chloride (CaCl{sub 2}) and sodium carbonate (Na{sub 2}CO{sub 3}) in order to produce calcium carbonate deposits on the filter membrane. Spark discharge in water was found to produce strong shockwaves in water, and the efficiency of the spark discharge in cleaning filter surface was evaluated by measuring the pressure drop across the filter over time. Results showed that the pressure drop could be reduced to the value corresponding to the initial clean state and after that the filter could be maintained at the initial state almost indefinitely, confirming the validity of the present concept of pulsed spark discharge in water to clean dirty filter. The present study also investigated the effect of a plasma-assisted self-cleaning filter on the performance of physical water treatment (PWT) solenoid coil for the mitigation of mineral fouling in a concentric counterflow heat exchanger. The self-cleaning filter utilized shockwaves produced by pulse-spark discharges in water to continuously remove scale deposits from the surface of the filter, thus keeping the pressure drop across the filter at a relatively low value. Artificial hard water was used in the present fouling experiments for three different cases: no treatment, PWT coil only, and PWT coil plus self-cleaning filter. Fouling resistances decreased by 59-72% for the combined case of PWT coil plus filter compared with the values for no-treatment cases. SEM photographs showed much smaller particle sizes for the combined case of PWT coil plus filter as larger particles were continuously removed from circulating water by the filter. The x-ray diffraction data showed calcite crystal structures for all three cases.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Investigation of Entrance-region Heat-transfer Coefficients

Experimental results of tests made at the Langley Memorial Aeronautical Laboratory are presented to show how heat-transfer coefficients can he increased by a method utilizing the high rate of heat transfer known to exist on any heat-transfer surface in the region adjacent to the edge on which the cooling or heating fluid impinges. The results show that, for the same pressure drop, the average surface heat-transfer.coefficient can be increased 50 to 100 percent when a cooling surface having a length of four inches in the direction of fluid flow is cut to form twenty fins with a length of 0.2 inch in the direction of fluid flow and the fins are sharpened and staggered in the air stream. The percentage of increase in the surface heat-transfer coefficient obtained as a result of shortening the length of the cooling surface varies with the pressure drop of the cooling fluid in passing the surface, the increase being largest when small pressure drop is used and smallest when high pressure drop is used.

HEAT EXCHANGERS - PRESSURE DROP↗

An Assessment of Helium Evolution from Helium-Saturated Propellant Depressurization in Space

Helium evolution from the transfer of helium-saturated propellant in space is quantified to assess its impacts from creating two-phase gas/liquid flow from the supply tank, gas injection into the receiving tank, and liquid discharge from the receiving tank. Propellant transfer takes place between two similar tanks whose maximum storage capacity is approximately 2.55 cubic meters each. The maximum on-orbit propellants transfer capability is 9000 lbm (fuel and oxidizer). The transfer line is approximately 1.27 cm in diameter and 6096 cm in length and comprised of the fluid interconnect system (FICS), the orbiter propellant transfer system (OPTS), and the International Space Station (ISS) propulsion module (ISSPM). The propellant transfer rate begins at approximately 11 liter per minute (lpm) and subsequently drops to approximately 0.5 lpm. The tank nominal operating pressure is approximately 1827 kPa (absolute). The line pressure drops for Monomethy1hydrazine (MMH) and Nitrogen tetroxide (NTO) at 11.3 lpm are approximately 202 kPa and 302 kPa, respectively. The pressure-drop results are based on a single-phase flow. The receiving tank is required to vent from approximately 1827 kPa to a lower pressure to affect propellant transfer. These pressure-drop scenarios cause the helium-saturated propellants to release excess helium. For tank ullage venting, the maximum volumes of helium evolved at tank pressure are approximately 0.5 ft3 for MMH and 2 ft3 for NTO. In microgravity environment, due to lack of body force, the helium evolution from a liquid body acts to propel it, which influences its fluid dynamics. For propellant transfer, the volume fractions of helium evolved at line pressure are 0.1% by volume for MMH and 0.6 % by volume for NTO at 11.3 lpm. The void fraction of helium evolved varies as an approximate second order power function of flow rate.

Nguyen, Bich N.↗

Evaluation of operational control strategies applicable to solar chimney power plants

Numerical simulations are carried out to study the performance of two schemes of power output control applicable to solar chimney power plants. Either the volume flow or the turbine pressure drop is used as independent control variable. Values found in the literature for the optimum ratio of turbine pressure drop to pressure potential vary between 2/3 and 0.97. It is shown that the optimum ratio is not constant during the whole day and it is dependent of the heat transfer coefficients applied to the collector. This study is a contribution towards understanding solar chimney power plant performance and control and may be useful in the design of solar chimney turbines. (author)

14 SOLAR ENERGY↗

Laser-Processed Condensing Heat Exchanger for Space Applications

In sizing a condensing heat exchanger for space life support systems, there is a limit to allowable pressure drop along with a required vapor recuperation rate. This sizing is performed by using known heat transfer and pressure drop correlations in a numerical model. Dimpling the surface of an air-liquid channeled heat exchanger increases the convective heat transfer rate however creates difficulties within the numerical model as the flat plate correlations are no longer accurate. To increase the fidelity of the numerical model used for sizing the heat exchanger Computational Fluid Dynamics (CFD) with an SST k-ω turbulence model was performed on a periodic portion of the heat exchanger. Through CFD modeling a heat flux and pressure drop was measured across the heat exchanger channel, this information was used to create a localized Nusselt number that was incorporated into the numerical model along with a more accurate pressure drop due to the dimpled surface. Additionally, through modeling the heat exchanger after manufacturing and assembly in Computer Aided Drafting (CAD) software there was an increase in the measurement accuracy of geometric features which was incorporated into the numerical model for further increase in fidelity.

heat exchanger↗

Gas-Liquid Flows Through Porous Media in Microgravity: The International Space Station Packed Bed Reactor Experiment

Experimental results on pressure drop and flow patterns for gas-liquid flow through packed beds obtained in the International Space Station with two types of packing are presented and analyzed. It is found that the pressure drop depends on the packing wettability in the viscous-capillary (V-C) regime and this dependence is compared with previously published results developed using short duration low-gravity aircraft tests. Within the V-C regime, the capillary contribution is the dominant force contributing to the pressure drop for the wetting case (glass) versus the viscous contribution dominating for the non-wetting case (Teflon). Outside of the V-C regime, it is also found that hysteresis effects that are often strong in normal gravity gas-liquid flows are greatly diminished in microgravity and pressure drop is nearly independent of packing wettability. A flow pattern transition map from bubble to pulse flow is also compared with the earlier aircraft data.

Viscous-capiliary regime↗

Thermalhydraulic calculation for boiling water reactor and its natural circulation component

Thermalhydraulic of reactor core is the thermal study on fluids within the core reactor, i.e. analysis of the thermal energy transfer process produced by fission reaction from fuel to the reactor coolant. This study include of coolant temperature and reactor power density distribution. The purposes of this analysis in the design of nuclear power plant are to calculate the coolant temperature distribution and the chimney height so natural circulation could be occurred. This study was used boiling water reactor (BWR) with cylinder type reactor core. Several reactor core properties such as linear power density, mass flow rate, coolant density and inlet temperature has been took into account to obtain distribution of coolant density, flow rate and pressure drop. The results of calculation are as follows. Thermal hydraulic calculations provide the uniform pressure drop of 1.1 bar for each channels. The optimum mass flow rate to obtain the uniform pressure drop is 217g/s. Furthermore, from the calculation it could be known that outlet temperature is 288°C which is the saturated fluid’s temperature within the system. The optimum chimney height for natural circulation within the system is 14.88 m.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hydraulic Permeability of Resorcinol-Formaldehyde Resin

An ion exchange process using spherical resorcinol-formaldehyde (RF) resin is the baseline process for removing cesium from the dissolved salt solution in the high-level waste tanks at the Hanford Site, using large scale columns as part of the Waste Treatment Plant (WTP). The RF resin is also being evaluated for use in the proposed small column ion exchange (SCIX) system, which is an alternative treatment option at Hanford and at the Savannah River Site (SRS). A recirculating test loop with a small ion exchange column was used to measure the effect of oxygen uptake and radiation exposure on the permeability of a packed bed of the RF resin. The lab-scale column was designed to be prototypic of the proposed Hanford columns at the WTP. Although the test equipment was designed to model the Hanford ion exchange columns, the data on changes in the hydraulic permeability of the resin will also be valuable for determining potential pressure drops through the proposed SCIX system. The superficial fluid velocity in the lab-scale test (3.4-5.7 cm/s) was much higher than is planned for the full-scale Hanford columns to generate the maximum pressure drop expected in those columns (9.7 psig). The frictional drag from this high velocity produced forces on the resin in the lab-scale tests that matched the design basis of the full-scale Hanford column. Any changes in the resin caused by the radiation exposure and oxygen uptake were monitored by measuring the pressure drop through the lab-scale column and the physical properties of the resin. Three hydraulic test runs were completed, the first using fresh RF resin at 25 C, the second using irradiated resin at 25 C, and the third using irradiated resin at 45 C. A Hanford AP-101 simulant solution was recirculated through a test column containing 500 mL of Na-form RF resin. Known amounts of oxygen were introduced into the primary recirculation loop by saturating measured volumes of the simulant solution with oxygen and reintroducing the oxygenated simulant into the feed tank. The dissolved oxygen (DO) concentration of the recirculating simulant was monitored, and the amount of oxygen that reacted with the resin was determined from the change in the DO concentration of the recirculating simulant solution. Prior to hydraulic testing the resin for runs 2 and 3 was covered with the simulant solution and irradiated in a spent fuel element at the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Both batches of resin were irradiated to a total gamma dose of 177 Mrad, but the resin for run 2 reached a maximum temperature during irradiation of 51 C, while the resin for run 3 reached a temperature of 38 C. The different temperatures were the result of the operating status of HFIR at the time of the irradiation and were not part of the test plan; however, the results clearly show the impact of the higher-temperature exposure during irradiation. The flow rate and pressure drop data from the test loop runs show that irradiating the RF resin reduces both the void fraction and the permeability of the resin bed. The mechanism for the reduction in permeability is not clear because irradiation increases the particle size of the resin beads and makes them deform less under pressure. Microscopic examination of the resin beads shows that they are all smooth regular spheres and that irradiation or oxygen uptake did not change the shape of the beads. The resin reacts rapidly with DO in the simulant solution, and the reaction with oxygen reduces the permeability of a bed of new resin by about 10% but has less impact on the permeability of irradiated resin. Irradiation increases the toughness of the resin beads, probably by initiating cross-linking reactions in them. Oxygen uptake reduces the crush strength of both new and irradiated resin; however, the pressures that caused the beads to crush are much higher than would be expected during the operation of an ion exchange column. There was no visible evidence of broken beads in any of the resin samples taken from the test loop. Reaction with oxygen reduces the cesium distribution coefficient of the resin beads, as does irradiation. Higher temperatures during irradiation or during contact with the simulant solution further reduce the cesium distribution coefficient.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Flowrate testing of the bag filter LANCS-BOP 6CPVC-1.5-2SPVC (LANCS Industries) at 1 psig

The air flowrate through a flexible HEPA grade filter (Part LANCS-BOP 6CPVC-1.5-2SPVC www.lancsindustries.com) was measured at 48 ALPM for a differential pressure drop of 1.0 psig (28 inWC, 7.0 kPa). These filters are rated by the manufacturer to have a flowrate of 3 ALPM at a differential pressure drop of 1 inWC (0.25 kPa). The Los Alamos National Laboratory Aerosol Engineering Facility used one of their test rigs (originally developed to measure the pressure drop in capsule HEPA filters) to measure the airflow through the LANCS bag filter.

42 ENGINEERING↗

Enhancement of operational Flexibility of Power Plants Using IN740

Headers are crucial components within diverse industries, especially in the energy sector, as they enable the efficient transfer of fluids. The selection of materials for headers is determined by their specific applications; for example, Grade 91 and Grade 92 steels are commonly utilized. In our research, we recommend the adoption of INCONEL alloy 740 due to its exceptional robustness and heat-resistant characteristics. One critical parameter in header systems is the heat transfer coefficient, which directly influences the efficiency of heat exchange processes and can thereby impact the structural integrity of the headers. This coefficient is closely linked with factors such as the Nusselt number, which is influenced by fluid flow characteristics and thermal properties. The flow direction within headers, whether unidirectional or multidirectional—significantly affects the overall dynamics of heat transfer. This research focuses on exploring the behavior of headers, a specific pipeline system component, using ANSYS simulation software. The study aims to predict heat transfer and mechanical behavior within headers under various conditions through steady-state and transient simulations (parts 1 and 2 of the report). Key parameters such as heat transfer coefficient, velocity, and temperature are examined with the goal of optimizing header design. Part 3 of the report addresses the critical yet underexplored relationship between pressure drop and heat transfer coefficients in the transient flow regime within headers, specifically focusing on smooth horizontal circular tubes. Limited experimental work has been conducted in this area, prompting the need for comprehensive analysis. By leveraging machine learning techniques, this research aims to establish a correlation between pressure drop and heat transfer across various flow conditions, including laminar, transient, quasi-turbulent, and turbulent regimes. The data utilized for this analysis were meticulously gathered from existing literature, capturing simultaneous measurements of pressure drops and heat transfer. Part 4: In the context of power plants, header pipes are essential components that significantly influence system performance by facilitating the collection and distribution of steam. This report highlights the critical role of header pipes in enhancing reliability, efficiency, and overall power plant performance. A key aspect of this investigation is shape optimization, which aims to maximize performance while minimizing material usage. By focusing on shape optimization, this research contributes to improved efficiency and a reduced environmental footprint for power plant installations. The methodology developed in this study emphasizes optimizing header shapes to decrease reliance on expensive alloy materials and lower maintenance costs. Furthermore, a case study was conducted using a header from an operational power plant to validate the proposed optimization techniques. Finally, part 5 addresses the challenges associated with flexible operations in boiler systems, the study outlines several strategies for enhancing the durability and reliability of steam headers. Key approaches include material selection, which involves utilizing advanced materials with superior high-temperature properties and enhanced fatigue resistance to extend the lifespan of steam headers. Design modifications are also recommended, focusing on implementing changes that mitigate thermal stress and cyclic loading to reduce the likelihood of failures under varying operating conditions. Additionally, the study emphasizes the importance of regular inspection and monitoring by establishing rigorous protocols to detect early signs of damage, allowing for timely maintenance and minimizing the risks of catastrophic failures. Furthermore, operational guidelines are developed to minimize the frequency and severity of thermal transients, ensuring stable and efficient operations. Collectively, these strategies provide a robust framework for overcoming the unique challenges posed by flexible operation in boiler systems, ultimately contributing to improved reliability and performance in power plant operations. Through this comprehensive approach, the study not only enhances the understanding of pressure drop and heat transfer relationships but also promotes advancements in design and operation that will benefit the entire power generation industry.

01 COAL, LIGNITE, AND PEAT↗

Two-phase flow characteristics in multiple orifice valves

This work presents an experimental investigation on the characteristics of two-phase flow through multiple orifice valve (MOV), including frictional pressure drop and void fraction. Experiments were carried out using an MOV with three different sets of discs with throat thickness-diameter ratios (s/d) of 1.41, 1.66 and 2.21. Tests were run with air and water flow rates ranging between 1.0 and 3.0 m{sup 3}/h, respectively. The two-phase flow patterns established for the experiment were bubbly and slug. Two-phase frictional multipliers, frictional pressure drop and void fraction were analyzed. The determined two-phase multipliers were compared against existing correlations for gas-liquid flows. None of the correlations tested proved capable of predicting the experimental results. The large discrepancy between predicted and measured values points at the role played by valve throat geometry and thickness-diameter ratio in the hydrodynamics of two-phase flow through MOVs. A modification to the constants in the two-phase multiplier equation used for pipe flow fitted the experimental data. A comparison between computed frictional pressure drop, calculated with the modified two-phase multiplier equation and measured pressure drop yielded better agreement, with less than 20% error. (author)

42 ENGINEERING↗

Experimental studies of adiabatic flow boiling in fractal-like branching microchannels

Experimental results of adiabatic boiling of water flowing through a fractal-like branching microchannel network are presented and compared to numerical model simulations. The goal is to assess the ability of current pressure loss models applied to a bifurcating flow geometry. The fractal-like branching channel network is based on channel length and width ratios between adjacent branching levels of 2{sup -1/2}. There are four branching sections for a total flow length of 18 mm, a channel height of 150 {mu}m and a terminal channel width of 100 {mu}m. The channels were Deep Reactive Ion Etched (DRIE) into a silicon disk. A Pyrex disk was anodically bonded to the silicon to form the channel top to allow visualization of the flow within the channels. The flow rates ranged from 100 to 225 g/min and the inlet subcooling levels varied from 0.5 to 6 C. Pressure drop along the flow network and time averaged void fraction in each branching level were measured for each of the test conditions. The measured pressure drop ranged from 20 to 90 kPa, and the measured void fraction ranged from 0.3 to 0.9. The measured pressure drop results agree well with separated flow model predictions accounting for the varying flow geometry. The measured void fraction results followed the same trends as the model; however, the scatter in the experimental results is rather large. (author)

42 ENGINEERING↗

Improvements to CTF Closure Models for Modelling of Two-Phase Flow

This report documents the efforts to improve the CTF prediction of void fraction and two-phase pressure drop by improving two-phase closure models. Previous validation activities have revealed that CTF tends to overpredict void fraction and two-phase pressure drop. In response to this, two approaches were taken to improve CTF’s predictive capabilities. Based on findings that the interfacial drag and subcooled boiling models significantly impact void prediction, alternative closure models for these physical effects were found and implemented into the code. An extensive assessment was performed by using the existing and newly added two-phase experimental data, which showed that void prediction, wall temperature, and two-phase pressure-drop results are improved by using the newly implemented models. A second approach for improving CTF modeling accuracy involved the use of a Bayesian calibration process that uses CTF validation data to optimize selected modeling coefficients and closure model multipliers to achieve a more accurate prediction of experimental results. A similar assessment was performed with calibrated models that improved the void and pressure-drop prediction for test cases that were both included and not included in the calibration dataset. Results of this study will be used to change the models used in CTF to achieve more accurate BWR analyses moving forward. This study also identified opportunities for improving additional closure models and other opportunities to use calibration techniques to improve CTF.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Investigation of Two-Phase Flows in Piping Bends and Elbows

An experimental investigation of the hydrodynamic characteristics of two-phase R-113 flow has been carried out. Straight tube pressure drop data, as a function of mass flow rate (mass flux) and flow quality has been obtained using the Two-Phase Flow Test Facility located in the Advanced Thermal Laboratories of the Crew and Thermal Systems Division at the Lyndon B. Johnson Space Center. Additionally, after successfully obtaining the straight tube pressure drop data, the test facility was modified in order to obtain pressure drop data for the flow of two-phase R-113 through 180 deg piping bends. Inherent instabilities of the test facility prevented the successful acquisition of pressure drop data through the piping bends. The experimental straight tube data will be presented and compared with existing predictive correlations in an attempt to gain insight into the utility of such correlations as the basis for developing design criteria. A discussion of the instabilities which rendered successful acquisition of the piping bend data will be presented and suggestions will be made for eliminating these system tendencies. Finally, recommendations for future investigations, based on successful reconfiguration of the test facility, will be made.

Duncan, Allen B.↗

3D printed structures for optimized carbon capture technology in packed bed columns

The use of 3D printed structured packing for the optimization of aqueous-amine based carbon capture in packed absorption columns is examined in this paper. An experimental testing system has been set up, and initial comparisons were made between metal, plastic, and 3D printed 16-inch packing elements and between three 8-inch 3D printed elements of different densities. Pressure drop measurements were obtained at various air flowrates under dry conditions. Measurements were also taken for a wet system by adding water at six different liquid flowrates. In each case, theoretical calculations for pressure drop were performed based on a model presented in the literature. It was found that, for the 16-inch dry column, the model slightly overpredicts the pressure drop. The model provides an accurate prediction for the dry 8-inch experimental data, especially for the two least dense packing elements. For the wet system, the model overpredicts the pressure drop, likely due to modeling deficiencies when the column reaches its loading limit. Furthermore, these results provide sufficient confidence to move forward with testing and process intensification of the CO 2 capture process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗