Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DISTRIBUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Unified Design Theory for Multi-Port Polyphase Transformers Enabling Scalable Power-Multiplexed EV Fleet Charging Systems

This paper presents a unified analytical design theory for multi-port polyphase transformers, targeting scalable and isolated high-power Electric Vehicle (EV) fleet charging systems with power multiplexing capability. As fleet electrification accelerates, conventional one-to-one charger architectures face significant challenges in infrastructure cost, peak power demand, and low utilization of installed power electronics. Power-multiplexed charging architectures, which dynamically distribute power from a shared pool of converter modules across multiple vehicles, have emerged as a promising solution. However, such architectures require scalable, isolated multi-port power interfaces capable of routing energy among multiple inputs and outputs, whose design remains complex and dependent on iterative modeling. To address this gap, the proposed theory provides closed-form expressions for self-inductance, leakage inductance, and mutual coupling terms for arbitrary multi-phase, multi-port transformer structures. The formulation enables direct synthesis of isolated multi-input and multi-output resonant converter systems without reliance on geometry-specific finite-element analysis or extensive parameter extraction. This capability is particularly critical for power-multiplexed systems, where modular converter structures must interface with multiple vehicles while maintaining galvanic isolation and flexible power allocation. The effectiveness of the proposed framework is demonstrated through the design of a 360 kW multi-phase system operating over a 700–900 VDC input and 400–1250 VDC output range. PLECS simulation results confirm accurate prediction of system behavior and validate the applicability of the approach to multi-port, power-multiplexed charging scenarios. The proposed method significantly reduces design complexity while enabling scalable, cost-effective, and fully utilized EV fleet charging infrastructure.

Asa, Erdem [ORNL] (ORCID:0000000190884812)↗

A Learning-based Supervisory Control Architecture for Electric Vehicle Charging System Paired with Energy Storages

A Machine Learning-based predictive model is developed for optimal dispatching energy storage system integrated with Electric Vehicle battery charger. The model is effectively trained using transfer learning algorithm and successfully validated via measurement data to achieve high fidelity and accuracy. The study findings provide possibilities for future development of the presented approach to implement computational heavy predictive algorithms with multi-step predictions in emerging modular bidirectional charger topologies to realize vehicle-to-grid (V2G) technology. The online tuning can be explored using the new measurements obtained during the operation, henceforth, enhancing the controller performance for integrating multiple DERs into distribution power networks that shows huge interest for the utilities and regulatory agencies. Multiple operation scenatios have been evaluated and simulation results are discussed to verify intended performance of the proposed control solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutronic analysis of a PWR-type SMR core using duplex ThO{sub 2}-UO{sub 2} in TRISO fuel particles

Currently, studies on small modular reactors (SMRs) present an important development due to the potential they represent in terms of safety, operational flexibility, economy, and non-energy applications. Furthermore, there is increasing interest in studying the use of thorium as fuel, as an effective way to solve problems such as the shortage of uranium reserves, reduction of nuclear waste and nuclear proliferation. Also, the use of thorium combined with highly enriched uranium TRISO particles has been studied, showing proper performance. In this work, the concept of ThO{sub 2}-UO{sub 2} duplex fuel is used, for the core configuration of a PWR type SMR that uses TRISO fuel, designed to achieve extended fuel cycles. Three distribution cases of ThO{sub 2} and UO{sub 2} in TRISO particles inside the fuel rods are compared. First, particles composed by a homogeneous mixture of ThO{sub 2} and UO{sub 2} are distributed inside of fuel elements. Second, the fuel zone of the fuel elements is divided into two radially, an internal one where the TRISO particles composed of ThO{sub 2} are distributed and the external one where the TRISO particles composed of UO{sub 2} are distributed. The third case is like the previous one, except that the particles that contain UO{sub 2} are distributed in the inner zone and those that contain ThO{sub 2} in the outer zone of the fuel elements. The comparison of the cases is carried out in terms of cycle main isotopes' mass transmutation, power distribution and temperature reactivity coefficients. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Physics-Informed Graph Neural Networks for Collaborative Dynamic Reconfiguration and Voltage Regulation in Unbalanced Distribution Systems

Network reconfiguration has long been employed as a strategic approach to minimize power distribution system losses and effectively regulate voltage levels. Tap-changing voltage regulators are also critical for controlling bus voltages, especially in accommodating the increasing integration of distributed energy resources (DERs) with intermittent outputs. This paper introduces novel methodologies to address the challenges of dynamic reconfiguration and optimal tap setting in unbalanced three-phase distribution systems. We propose an approximated mixed-integer quadratically constrained program (MIQCP) to model dynamic reconfiguration, along with a pioneering formulation for voltage regulator (VR) tap-setting based on Special Ordered Set type 1 (SOS1). To mitigate computational complexity, we propose a physics-informed spatial-temporal graph convolutional network (STGCN) with an integrated link classifier. The proposed approach enables efficient solution generation by fixing specific variables in the MIQCP instance and solving the simplified sub-MIP using an MIP solver. Numerical studies demonstrate the superior prediction accuracy of our STGCN model compared to baseline neural network models, resulting in reduced DER curtailment and voltage deviation with shorter computation time.

dynamic reconfiguration↗

Distributed Ledger Technology for Fault Tolerant Distribution Grid Operations

This paper explores the potential of distributed ledger technology (DLT) to improve fault-tolerant grid operations by leveraging its core features as an immutable, decentralized ledger, a distributed, consensus-based agreement process, and a distributed state-replication engine. Distribution power systems deliver electricity to millions of customers; however, they are susceptible to various threats that can result in customer interruptions. These include faults caused by adverse weather conditions, natural disasters, vegetation growth, equipment failure, and malicious attacks. To minimize the effects of these faults, fault-handling approaches rely on network knowledge to isolate affected areas and reconnect unaffected areas, reducing the number of affected customers while maintaining safety. Here, we present a trusted data-sharing architecture that enables independent, distributed actors to reconstruct the pre-fault system state by enabling distributed resources to make appropriate decisions with limited network/system information. Although the process requires some data sharing between switch-delimited areas, the approach limits the amount of private information shared, preserving customers' privacy and business-sensitive information. We include three use cases that form a foundation for third parties to develop functional solutions that can eventually be deployed in the field. The gross error detection method used within switch-delimited areas can identify sensor errors and accurately detect circuit breaker states. The evaluation of possible reconnection while preserving data ownership resulted in a voltage magnitude difference smaller than 0.001% from the OpenDSS power flow solution that has full system knowledge, which is below the expected power flow tolerance. The approach offers a promising opportunity for improving fault-tolerant distribution grid operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MCS solutions for the TVA Watts Bar Unit 1 multi-physics depletion benchmark

The high-fidelity solution for exercises 1-3 of the recently developed TVA Watts Bar Unit 1 multi-physics and multi-cycle depletion benchmark using MCS was coupled with two different thermal-hydraulics (TH) codes: TH1D and COBRA-TF (CTF), and their solutions were compared. The solutions from MCS/CTF and MCS/TH1D for typical Pressurized Water Reactor (PWR) problems are quite close. And to evaluate MCS solutions for the benchmark, their results were also compared against measured data as well as publicly available high-fidelity solutions. The MCS criticality solutions at Hot Zero Power (HZP) deviate within 50 pcm against the reference solutions. While for the critical boron concentration (CBC) search calculations, the difference on the MCS calculated CBC is about 7 ppm, and the root-mean-squared (RMS) errors for the assembly power distribution and outlet coolant temperature are less than 0.5% and 1 Celsius degree respectively. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multisource Data Fusion Outage Location in Distribution Systems via Probabilistic Graphical Models

Efficient outage location is critical to enhancing the resilience of power distribution systems. However, accurate outage location requires combining massive evidence received from diverse data sources, including smart meter (SM) last gasp signals, customer trouble calls, social media messages, weather data, vegetation information, and physical parameters of the network. This is a computationally complex task due to the high dimensionality of data in distribution grids. In this paper, we propose a multi-source data fusion approach to locate outage events in partially observable distribution systems using Bayesian networks (BNs). A novel aspect of the proposed approach is that it takes multi-source evidence and the complex structure of distribution systems into account using a probabilistic graphical method. Our method can radically reduce the computational complexity of outage location inference in high-dimensional spaces. The graphical structure of the proposed BN is established based on the network’s topology and the causal relationship between random variables, such as the states of branches/customers and evidence. Utilizing this graphical model, accurate outage locations are obtained by leveraging a Gibbs sampling (GS) method, to infer the probabilities of de-energization for all branches. Compared with commonly-used exact inference methods that have exponential complexity in the size of the BN, GS quantifies the target conditional probability distributions in a timely manner. As a result, a case study of several real-world distribution systems is presented to validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a high-fidelity multi-cycle model of the NuScale small modular reactor using VERA

With growing renewables penetration, there is increased interest in flexible power operation for nuclear reactors. For multi-unit SMRs, in particular the NuScale SMR, which is an integral pressurized water reactor, there are opportunities to optimize flexible power operation across multiple units to limit the degradation of structural and control components. Here, we focus on degradation of in-core components, specifically the control rods and reactor pressure vessel. To perform these studies a high-fidelity, multi-cycle representation of the NuScale SMR is required, with a detailed representation of the structural and control components. To this end, the NuScale SMR has been modelled using the Virtual Environment for Reactor Applications (VERA) software. The entire transition to equilibrium is simulated, from Cycle 1 through to the equilibrium cycle. The equilibrium cycle model shows a good agreement with the NuScale design certification application (DCA) results, with differences attributable to a combination of using public domain data for the present study, and methodological differences. K-effective, power distributions, reactivity coefficients, and boron letdown curves are compared and all found to closely match. This shows that the VERA model is suitable for further studies. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

CEFR simulation using diffusion code system RAST-F

In this study, the RAST-F code system, which is based on the two-step approach that couples a multi-group cross-section generation Monte-Carlo (MC) code and a multi-group nodal diffusion solver, was used for the neutronic simulation of the CEFR start-up experiments. The numerical solution of the RAST-F system was verified against the full core MC solution MCS at all control rods fully inserted and withdrawn states. The RAST-F solution of the selected experimental simulations was compared against the measurement data. A good agreement between RAST-F and MCS solutions was observed with less than 120 pcm discrepancies and 1.2% root-mean-square error in terms of k{sub eff} and power distribution, respectively. Meanwhile, the RAST-F result agreed well with the experimental data within two-sigma of experimental uncertainty. The good agreement of these results indicates that RAST-F can be used to neutronic steady-state simulations for small core-size SFR, which was challenged to deterministic code systems. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Communication enabled fast-acting imbalance reserve

A system and method for control of dispatchable resources on an electrical power distribution grid is disclosed. The disclosed method provides improved response to power imbalance based on a communications signal independent of system frequency. The communication signal provides a feed-forward control of dispatchable power resources. A communications network is employed to generate a signal to dispatchable resources that a power imbalance has occurred. Due to fast response power transmission network interfaces associated with the dispatchable resources, the respective resources respond in significantly less time than feedback controlled conventional generators which depend on line frequency sensing. The rapid response mitigates the impact of power imbalances and enables greater penetrations of converter-interfaced power generation units such as renewable energy sources to be connected to the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modernizing the Legacy Fission Wire Measurement System for the Advanced Test Reactor-Critical Facility

Operational lifetime extensions of existing research reactors have emphasized the need for refurbishment, replacements, and upgrades to supporting equipment and instrumentation. The Advanced Test Reactor (ATR) at Idaho National Laboratory (INL), which entered service in 1967, has recently completed the sixth core internals change-out and has scheduled operations until at least 2040. Reactor maintenance and operational risk management is critically important in the research reactor community, however supporting measurement systems sometimes get overlooked when maintenance is planned. The Fission Wire Measurement System (FWMS) is a custom measurement system designed in the 1960s to measure the beta-particle activity of irradiated uranium-aluminum fission wires. This measurement is conducted to determine the fission rate profile of the Advanced Reactor Test Critical (ATR-C) facility. The ATR-C is an open-pool, low-power test reactor that was purpose driven to resemble ATR and is used to qualify experiment configurations and verify core models prior to full-power experiment irradiations in ATR. A power distribution measurement in ATR-C uses uranium-aluminum wires that are distributed throughout the ATR-C core to validate simulation and modeling results. These measurements require 340 to 1500 wires to be irradiated and measured within a 12-hour window. The activity of the wires is measured in the required time with the FWMS, which was put into service in 1965 at the Radiation Measurements Laboratory (RML). The system consists of 4 measurement channels and one reference channel, each with a 2-pi proportional gas flow detector and the measurement channels each have an automated sample changer. This legacy system is crucial to the continued operations of ATR and has undergone some minor hardware upgrades since 1965, however the system presently relies on custom control boards, custom gas ion chambers, analog amplifiers/discriminators, and a user interface (UI) for the system written in outdated code. Much of the equipment and software is custom with no commercial replacements or support and limited documentation. The existing control software requires an operating system that is no longer supported, creating more vulnerabilities to continued operations. A project is underway with a third-party vendor to design, build, and document a new control and data acquisition system (CDAS) for the FWMS. The new upgrade will replace the control system, computer, UI, sample changer motors, and main power supply while maintaining the interface with existing detector hardware. The upgraded system will be operated in parallel with the current hardware and software to conduct validation testing. This equipment upgrade demonstrates the commitment at ATR to ensuring successful operations and potential future research reactors at INL.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Joint Expansion Planning of Power and Water Distribution Networks

This research considers the joint expansion planning of power and water distribution networks, which are interdependent at various levels. We consider the dependency arising through the power consumption of pumps and develop models for integrating new components into existing networks. Then, we formulate the joint expansion planning as a Mixed Integer Nonlinear Program (MINLP). Applying this MINLP to a small-scale test network, we illustrate the advantages offered by joint expansion planning, such as increased flexibility and reduced costs and redundancy, over independently expanding power and water distribution networks.

expansion planning↗

Heterogeneous network topology management and control

In one aspect, the present disclosure may provide devices or systems configured to receive indications of geographic areas, each corresponding to distribution networks, and determine whether the distribution networks overlap. The processor(s) may also be configured to receive parameter value(s) obtained by a device within one distribution network at a location within an overlapping area, and cause device(s) within another distribution network to modify operation based on the parameter value(s). In another aspect, the present disclosure may provide devices that include a voltage sensor to measure a voltage of a power distribution network at a power consumption location that corresponds to the device. The device may be configured to provide at least one cable service to the power consumption location via a cable television (CATV) distribution network and output an indication the measured voltage value.

Cruickshank, III, Robert Fraser↗

A CIM Based Data Integration Framework for Distribution Utilities

With the proliferation of distributed energy resources and advanced metering, modern electric power distribution systems are data rich and include advanced capabilities for distribution automation. Distribution utilities need applications for planning and operations that can integrate all the available data from the enterprise applications and may incorporate distributed approaches to operate and control. This paper describes a framework for standardizing and integrating the data available at different vendor specific applications in a utility utilizing the Common Information Model (CIM). Theframework incorporates the conversion of these the standardized CIM models into models compatible with GridLAB-D, an open source distribution system simulator, for developing advanced planning and operation strategies.

data integration platform, object-oriented data mo↗

Matrix Completion Using Alternating Minimization for Distribution System State Estimation

This paper examines the problem of state estimation in power distribution systems under low-observability conditions. The recently proposed constrained matrix completion method which combines the standard matrix completion method and power flow constraints has been shown to be effective in estimating voltage phasors under low-observability conditions using single-snapshot information. However, the method requires solving a semidefinite programming (SDP) problem, which becomes computationally infeasible for large systems and if multiple-snapshot (time-series) information is used. This paper proposes an efficient algorithm to solve the constrained matrix completion problem with time-series data. This algorithm is based on reformulating the matrix completion problem as a bilinear (non-convex) optimization problem, and applying the alternating minimization algorithm to solve this problem. This paper proves the summable convergence of the proposed algorithm, and demonstrates its efficacy and scalability via IEEE 123-bus system and a real utility feeder system. This paper also explores the value of adding more data from the history in terms of computation time and estimation accuracy.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Direct-DC Power in Buildings: Identifying the Best Applications Today for Tomorrow’s Building Sector

Driven by the increased use of direct current (DC) sources (photovoltaics, battery storage) and DC end-use devices (electronics, solid-state lighting, efficient motors), DC power distribution in buildings and DC microgrids have been proposed as a way to achieve greater efficiency, cost savings, and resiliency in a transitioning building sector. Despite these important benefits, several market and technological barriers inhibit the development of DC distribution, and the market for DC in buildings is still largely in the demonstration phase. Therefore, to jumpstart this technology, a clear path forward must emerge at this early stage of deployment. The goal of this paper is to define specific end-use cases for which DC distribution in buildings is a value proposition today by defining clear efficiency and resiliency benefits while addressing barriers to implementation. The paper begins with a technology and market assessment of DC distribution equipment, end uses, and technology standards. That is followed by results from an expert elicitation of DC power and building end-use professionals (e.g., electrical designers, building operators, engineers) and reports on-site visits and lessons learned from successful (and less successful) field deployments of DC distribution projects in North America. We present specific adoption pathways at the community and building level that can be implemented today, and evaluate them using qualitative and quantitative metrics, such as technology and market readiness, energy savings, and resiliency.

building-level electrical distribution↗

Building Large-Scale U.S. Synthetic Electric Distribution System Models

Rapid increases in distributed energy resources on distribution systems are prompting research efforts to improve and evaluate electric power distribution algorithms; however, there is a shortage of realistic, large-scale, U.S.-style test systems for the evaluation of such advanced algorithms. Some available tools to build large-scale test systems are of European style, and their application to studies focused on the United States might not be desirable given very different characteristics between the European and U.S. distribution designs. Motivated by this need, this paper develops detailed algorithms to build large-scale U.S. distribution systems and incorporates them in a new Reference Network Model, RNM-US. The approach starts with information from street maps and a catalog with electric equipment that includes power lines, transformers, voltage regulators, capacitors, and switching devices. The paper presents the algorithms through an illustrative case study of the different steps that comprise the process of building a synthetic distribution grid. Finally, the paper presents a medium- and a large-scale data set covering 10 million electrical nodes and 120,000 km of power lines, demonstrating the applicability of the proposed method to build very large-scale synthetic distribution systems.

27 ARPA - Advanced Research Projects Agency-Energy↗

Virtual Power Plants and Distributed Energy Resource Management Systems

Virtual Power Plants (VPPs) are aggregations of DERs that can balance electrical loads and provide utility-scale and utility-grade grid services like a traditional power plant. This presentation covers VPP definition, State-of-the-Art, Grid Architectures, Example VPP studies, VPP Standards, and VPP Roadmap.

24 POWER TRANSMISSION AND DISTRIBUTION↗