Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POLLUTION CONTROL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sandia National Laboratories, California Pollution Prevention Program annual report.

The annual program report provides detailed information about all aspects of the SNL/CA Pollution Prevention Program for a given calendar year. It functions as supporting documentation to the SNL/CA Environmental Management System Program Manual. The program report describes the activities undertaken during the past year, and activities planned in future years to implement the Pollution Prevention Program, one of six programs that supports environmental management at SNL/CA.

54 ENVIRONMENTAL SCIENCES↗

Study of Relation between Indoor Radon in Multi-storey Building and Outdoor Factors

A continuous radon monitoring in indoor and outdoor air was carried out for the period of one year. The relation between indoor radon and indoor-outdoor temperature difference, as well as between indoor radon and outdoor radon was investigated. The best correlation was obtained between indoor and outdoor radon concentrations.

54 ENVIRONMENTAL SCIENCES↗

UNIQUE APPROACH TO COMPLYING WITH VERY LOW NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM PERMIT LIMITS FOR COPPER

The NPDES permit issued to the Savannah River Site (SRS) in 2003 contained copper limits as low as six micrograms per liter. It also contained compliance schedules that provided SRS with anywhere from three to five years to select and implement projects that would enable compliance at several outfalls. Some outfall problems were much more difficult to correct than others. SRS personnel implemented several innovative projects in order to meet compliance schedule deadlines as inexpensively as possible. One innovation, constructing a humic acid feed system to increase effluent dissolved organic carbon (DOC) content, has proven to be very successful.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Evaluation of BOC'S Lotox Process for the Oxidation of Elemental Mercury in Flue Gas from a Coal-Fired Boiler

Linde's Low Temperature Oxidation (LoTOx{trademark}) process has been demonstrated successfully to remove more than 90% of the NOx emitted from coal-fired boilers. Preliminary findings have shown that the LoTOx{trademark} process can be as effective for mercury emissions control as well. In the LoTOx{trademark} system, ozone is injected into a reaction duct, where NO and NO{sub 2} in the flue gas are selectively oxidized at relatively low temperatures and converted to higher nitrogen oxides, which are highly water soluble. Elemental mercury in the flue gas also reacts with ozone to form oxidized mercury, which unlike elemental mercury is water-soluble. Nitrogen oxides and oxidized mercury in the reaction duct and residual ozone, if any, are effectively removed in a wet scrubber. Thus, LoTOx{trademark} appears to be a viable technology for multi-pollutant emission control. To prove the feasibility of mercury oxidation with ozone in support of marketing LoTOx{trademark} for multi-pollutant emission control, Linde has performed a series of bench-scale tests with simulated flue gas streams. However, in order to enable Linde to evaluate the performance of the process with a flue gas stream that is more representative of a coal-fired boiler; one of Linde's bench-scale LoTOx{trademark} units was installed at WRI's combustion test facility (CTF), where a slipstream of flue gas from the CTF was treated. The degree of mercury and NOx oxidation taking place in the LoTOx{trademark} unit was quantified as a function of ozone injection rates, reactor temperatures, residence time, and ranks of coals. The overall conclusions from these tests are: (1) over 80% reduction in elemental mercury and over 90% reduction of NOx can be achieved with an O{sub 3}/NO{sub X} molar ratio of less than two, (2) in most of the cases, a lower reactor temperature is preferred over a higher temperature due to ozone dissociation, however, the combination of both low residence time and high temperature proved to be effective in the oxidation of both NOx and elemental mercury, and (3) higher residence time, lower temperature, and higher molar ratio of O{sub 3}/NOx contributed to the highest elemental mercury and NOx reductions.

01 COAL, LIGNITE, AND PEAT↗

Environmental licensing in Brazilian's crushed stone industries

Highlights: • Failures in environmental reporting compromise the effectiveness of the environmental license process • The infrastructure of environmental agencies must be improved • The participation of society is essential for monitoring industries - Abstract: The crushed stone industries' activities are characterized by the extraction and processing of stones for use as aggregates in construction. The sector causes environmental impacts that can be mitigated by the implementation of control instruments, namely, environmental licensing, whose purpose is to carry out monitoring of potentially polluting activities. In this paper, it was analyzed the environmental studies of three industries located in Monsenhor Gil, Piauí, Brazil, elaborated as requisites for obtaining the environmental and mineral licenses. There were made visits to the State Department of Environment and Water Resources (SEMAR) and to the National Department of Mineral Production (DNPM) to verify the environmental reports and the environmental and mineral licensing processes. There were also made visits to the analyzed industries, with the aim of comparing the information contained in the studies, with the reality and verifying the implementation of the mitigating measures proposed in them, through the observation of the industries operation, and interviews with the responsible managers. Furthermore, it was made a research in the scientific literature, to know the licensing process in other countries, to compare with the Brazilian reality. From the research, in Brazilian industries, it was observed that, although all the legal steps to obtain the licenses have been fulfilled, the environmental reports have elaboration failures, such as the lack of a multidisciplinary team and the fact that some data diverge from the reality, decreasing the reliability of the evaluation of the environmental impacts caused by the projects. Also, the environmental replacement cost is not accounted in the final value of the product, and any of the industries have started the implementation of the proposed mitigation measures since they do not have mineral depletion areas. SEMAR was delayed in issuing licenses within the period established by law, and there are no periodic inspections by both the environmental agency and DNPM. It should also be pointed out that the community did not claim public hearings and there is no participation in environmental education projects, factors that compromise the effectiveness of the environmental licensing process. Regarding the process in other parts of the world, in some countries, such as Uruguay and Paraguay, the agency responsible for licensing and inspection is federal. In Argentina, as in Brazil and USA, states have autonomy to legislate on environmental issues. There is also divergence in the period of execution of the licenses, being 12 months in Brazil, while in Thailand it can be up to 56 days. In Peru, the society participation is much more representative than in Brazil, and there is differentiation in the collection form of environmental compensation fees, among countries. The failures pointed out in the Brazilian process, as well as the system of other countries, can serve as parameters for the improvement of the process' effectiveness, both in Brazil and in other parts of the world, aiming at the conservation of the environment.

54 ENVIRONMENTAL SCIENCES↗

A modeling study of coarse particulate matter pollution in Beijing: regional source contributions and control implications for the 2008 summer Olympics

In the last 10 yr, Beijing has made a great effort to improve its air quality. However, it is still suffering from regional coarse particulate matter (PM10) pollution that could be a challenge to the promise of clean air during the 2008 Olympics. To provide scientific guidance on regional air pollution control, the Mesoscale Modeling System Generation 5 (MM5) and the Models-3/Community Multiscale Air Quality Model (CMAQ) air quality modeling system was used to investigate the contributions of emission sources outside the Beijing area to pollution levels in Beijing. The contributions to the PM10 concentrations in Beijing were assessed for the following sources: power plants, industry, domestic sources, transportation, agriculture, and biomass open burning. In January, it is estimated that on average 22% of the PM10 concentrations can be attributed to outside sources, of which domestic and industrial sources contributed 37 and 31%, respectively. In August, as much as 40% of the PM10 concentrations came from regional sources, of which approximately 41% came from industry and 31% from power plants. However, the synchronous analysis of the hourly concentrations, regional contributions, and wind vectors indicates that in the heaviest pollution periods the local emission sources play a more important role. The implications are that long-term control strategies should be based on regional-scale collaborations, and that emission abatement of local sources may be more effective in lowering the PM10 concentration levels on the heavy pollution days. Better air quality can be attained during the Olympics by placing effective emission controls on the local sources in Beijing and by controlling emissions from industry and power plants in the surrounding regions. 44 refs., 6 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Economic implications of incorporating emission controls to mitigate air pollutants emitted from a modeled hydrocarbon-fuel biorefinery in the United States

The implementation of the US Renewable Fuel Standard is expected to increase the construction and operation of new biofuel facilities. Allowing this industry to grow without adversely affecting air quality is an important sustainability goal sought by multiple stakeholders. However, little is known about how the emission controls potentially required to comply with air quality regulations might impact biorefinery cost and deployment strategies such as siting and sizing. In this study, we use a baseline design for a lignocellulosic hydrocarbon biofuel production process to assess how the integration of emission controls impacts the minimum fuel selling price (MFSP) of the biofuel produced. We evaluate the change in MFSP for two cases as compared to the baseline design by incorporating (i) emission controls that ensure compliance with applicable federal air regulations and (ii) advanced control options that could be used to achieve potential best available control technology (BACT) emission limits. Our results indicate that compliance with federal air regulations can be achieved with minimal impact on biofuel cost (~$0.02 per gasoline gallon equivalent (GGE) higher than the baseline price of $5.10 GGE -1 ). However, if air emissions must be further reduced to meet potential BACT emission limits, the cost could increase nontrivially. For example, the MFSP could increase to $5.50 GGE -1 by adopting advanced emission controls to meet potential boiler BACT limits. Finally, given tradeoffs among emission control costs, permitting requirements, and economies of scale, these results could help inform decisions about biorefinery siting and sizing and mitigate risks associated with air permitting.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Mode-Converted (P-SV) Waves for Imaging Thin Intercalated Basaltic Layers and Their Possible Geologic Implications

The subsurface imaging using conventional seismic reflection technique is challenging in areas where high velocity rocks such as basalts are underlain by low velocity rocks. The seismic image quality worsens in the presence of intercalated sediments within the basaltic layers. In the recent years, the multicomponent seismic exploration technique has drawn great attention because it reduces the ambiguity in seismic imaging, enlarges the S-wave information, and improves the prediction and identification of reservoir fluids. Improvements in sub-basalt imaging techniques could hold highly significant geologic implications such as resource exploration and identifying permanent geochemical trapping potential (such as for carbon sequestration studies). In this article, we examine the possibility of utilizing mode-converted (P-SV) waves for sub-basalt imaging as well as likely complicacies one may expect in such processes.

58 GEOSCIENCES↗

Technology demonstration for reducing mercury emissions from small-scale gold refining facilities.

Gold that is brought from artisanal and small-scale gold mining areas to gold shops for processing and sale typically contains 5-40% mercury. The uncontrolled removal of the residual mercury in gold shops by using high-temperature evaporation can be a significant source of mercury emissions in urban areas where the shops are located. Emissions from gold shop hoods during a burn can exceed 1,000 mg/m{sup 3}. Because the saturation concentration of mercury vapor at operating temperatures at the hood exhaust is less than 100 mg/m{sup 3}, the dominant component of the exhaust is in the form of aerosol or liquid particles. The U.S. Environmental Protection Agency (EPA), with technical support from Argonne National Laboratory (Argonne), has completed a project to design and test a technology to remove the dominant aerosol component in the emissions from gold shops. The objective was to demonstrate a technology that could be manufactured at low cost and by using locally available materials and manufacturing capabilities. Six prototypes designed by Argonne were locally manufactured, installed, and tested in gold shops in Itaituba and Creporizao, Brazil. The initial prototype design incorporated a pebble bed as the media for collecting the mercury aerosols, and a mercury collection efficiency of over 90% was demonstrated. Though achieving high efficiencies, the initial prototype was determined to have practical disadvantages such as excessive weight, a somewhat complex construction, and high costs (>US$1,000). To further simplify the construction, operation, and associated costs, a second prototype design was developed in which the pebble bed was replaced with slotted steel baffle plates. The system was designed to have flexibility for installation in various hood configurations. The second prototype with the baffle plate design was installed and tested in several different hood/exhaust systems to determine the optimal installation configuration. The significance of coagulation and collection of the mercury aerosols in exhaust ducts, which is dependent on the hood and collector configuration, was also evaluated. Prototype demonstration tests verified the theoretical basis for mercury aerosol capture that can be used to optimize the baffle plate design, flow rates, and hood exhaust ducts and plenum to achieve 80% or higher removal efficiencies. Results indicated that installation configuration significantly influences a system's capture efficiency. Configurations that retained existing inlet ducts resulted in system efficiencies of more than 80%, whereas installation configurations without inlet ducts significantly reduced capture efficiency. As an alternative to increasing the volume of inlet ducts, the number of baffle plates in the system baffle assembly could be doubled to increase efficiency. Recommended installation and operation procedures were developed on the basis of these results. A water-based mercury capture system developed in Indonesia for installation in smaller shops was also tested and shown to be effective for certain applications. The cost of construction and installation of the baffle plate prototype was approximately US$400. These costs were reported as acceptable by local gold shop owners and government regulators, and were significantly lower than the cost of an alternate charcoal/copper mesh mercury filter available in the region, which costs about US$10,000. A sampling procedure that consists of a particle filter combined with a vapor analyzer was demonstrated as an effective procedure for analyzing both the aerosol and vapor components of the mercury concentrations. Two key findings for enhancing higher mercury collection were identified. First, the aerosol/vapor mercury emissions must be given sufficient time for the mercury particles to coagulate to a size that can be readily captured by the baffle plates. An interval of at least 6 seconds of transit time between the point of evaporation and contact with the slotted baffle plates is recommended. Some particles will also deposit in the exhaust ducts between the point of evaporation and the baffle plates. Second, the slots in the baffle plates create jets that force the mercury particles to impinge and adhere on downstream surfaces. The baffle plates should closely follow the designs developed for this system to be most effective.

54 ENVIRONMENTAL SCIENCES↗

Computer simulation as a NOx reduction design tool

Nalco Mobotec engineers were charged with reducing emissions on a utility boiler converted from burning oil to eastern bituminous coal using the company's Rotamix selective noncatalytic reduction (SNCR) system which injects urea into the furnace. A CFD simulation of the existing boiler was first conducted and then the furnace was simulated with the SNCR system added and the design was optimised. Operating and capital costs were minimised by optimal placement of 50 injector ports. 6 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Is it time to rethink SO{sub 2} control technology selection?

The article traces the history of flue gas desulfurization (FGD) systems in power plants in the USA following the 1990 Clean Air Act which divided boilers into Phase I (larger SO{sub 2} emitters) and Phase II units. The Clean Air Interstate Rule (CAIR) will soon require emission control on smaller boilers burning low and medium-sulfur coal. Today the systems of choice are dry FGD systems for low sulfur coals and greater than wet LSFO. (limestone forced oxidation systems) for coal with sulfur content about 2%. Demand for wet FGD coupled with tighter regulations has led to significant cost increases in LSFO. technology. 4 refs., 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Dual discounting in cost-benefit analysis for environmental impacts

Discounting has been a long-established intertemporal efficiency tool in cost-benefit analysis which focuses on project selection at communal level with a view to maximising the social welfare. However, with the relentless growth in environmental stress that, in good parts, stems from investment projects the established criterion in discounting appears to be inadequate especially when environmental issues are taken into consideration. This paper looks at how dual focus on efficiency and sustainability can be achieved by using dual discounting, i.e. discounting environmental benefits separately and differently from other costs and benefits and applies this alternative criterion to an afforestation scheme in the United Kingdom which contains carbon sequestration in addition to timber benefits.

54 ENVIRONMENTAL SCIENCES↗

Cliffside 6 integrated emissions control system

The article takes an inside look into the environmental hardware going into one of the highest profile coal-fired power plants projects in the US, a new 800 MW supercritical coal-fired facility at Cliffside, NC, Unit C6. This is currently under construction and scheduled to be in commercial service in 2012. To evaluate the alternative air quality control system (AQCS) options, Duke Energy established a cross-functional team and used a decision analysis process to select the 'best balanced choice'. Alstom's integrated AQCS which combines dry and wet flue gas desulfurization systems was the best balanced choice. Replacing an ESP with a spray dryer absorber achieved major cost savings and eliminated the need for wastewater treatment. 1 ref., 2 photos.

01 COAL, LIGNITE, AND PEAT↗

Comparing materials used in mist eliminators

Wet flue gas desulfurization (FGD) systems, or wet scrubbers, are notoriously capital - and maintenance-intensive. Mist eliminators are an integral part of most wet FGD systems. These are available in a variety of materials - polypropylene, fiberglass reinforced polymer (FRP), polysulfone and stainless steel. The article discusses the material properties, performance attributes and relative cost differences associated with each of these four materials. It describes the common problems with mist eliminators - fouling and corrosion. These can be minimised by routine cleaning and use of chemical additives to prevent deposition. An analysis was carried out to compare the four materials at APS Cholla power plant. As a result the facility is retrofitting its remaining wet scrubber towers in Unit 2 with mist eliminators constructed from polysulfone as each of the current ones of the existing polypropylene needs replacing. Polysulfone is cheaper to clean and components require replacing less frequently than polypropylene. Switching from stainless steel to polypropylene has proved advantageous on 22 wet scrubbers operated by PPL Montana. 5 figs. 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

An integrated analytical framework for quantifying the LCOE of waste-to-energy facilities for a range of greenhouse gas emissions policy and technical factors

This study presents a novel integrated method for considering the economics of waste-to-energy (WTE) facilities with priced greenhouse gas (GHG) emissions based upon technical and economic characteristics of the WTE facility, MSW stream, landfill alternative, and GHG emissions policy. The study demonstrates use of the formulation for six different policy scenarios and explores sensitivity of the results to ranges of certain technical parameters as found in existing literature. The study shows that details of the GHG emissions regulations have large impact on the levelized cost of energy (LCOE) of WTE and that GHG regulations can either increase or decrease the LCOE of WTE depending on policy choices regarding biogenic fractions from combusted waste and emissions from landfills. Important policy considerations are the fraction of the carbon emissions that are priced (i.e. all emissions versus only non-biogenic emissions), whether emissions credits are allowed due to reducing fugitive landfill gas emissions, whether biogenic carbon sequestration in landfills is credited against landfill emissions, and the effectiveness of the landfill gas recovery system where waste would otherwise have been buried. The default landfill gas recovery system effectiveness assumed by much of the industry yields GHG offsets that are very close to the direct non-biogenic GHG emissions from a WTE facility, meaning that small changes in the recovery effectiveness cause relatively larger changes in the emissions factor of the WTE facility. Finally, the economics of WTE are dependent on the MSW stream composition, with paper and wood being advantageous, metal and glass being disadvantageous, and plastics, food, and yard waste being either advantageous or disadvantageous depending upon the avoided tipping fee and the GHG emissions price.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Should a coal-fired power plant be replaced or retrofitted?

In a cap-and-trade system, a power plant operator can choose to operate while paying for the necessary emissions allowances, retrofit emissions controls to the plant, or replace the unit with a new plant. Allowance prices are uncertain, as are the timing and stringency of requirements for control of mercury and carbon emissions. We model the evolution of allowance prices for SO{sub 2}, NOx, Hg, and CO{sub 2} using geometric Brownian motion with drift, volatility, and jumps, and use an options-based analysis to find the value of the alternatives. In the absence of a carbon price, only if the owners have a planning horizon longer than 30 years would they replace a conventional coal-fired plant with a high-performance unit such as a supercritical plant; otherwise, they would install SO{sub 2} and NOx controls on the existing unit. An expectation that the CO{sub 2} price will reach $50/t in 2020 makes the installation of an IGCC with carbon capture and sequestration attractive today, even for planning horizons as short as 20 years. A carbon price below $40/t is unlikely to produce investments in carbon capture for electric power. 1 ref., 5 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗