Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHOTOMULTIPLIERS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

Performance measurements of the electromagnetic calorimeter and readout electronics system for the DarkQuest experiment

Here, this paper presents performance measurements of a new readout electronics system based on silicon photomultipliers for the PHENIX electromagnetic calorimeter. Installation of the lead-scintillator Shashlik style calorimeter into the SeaQuest/SpinQuest spectrometer has been proposed to broaden the experiment’s dark sector search program, an upgrade known as DarkQuest. The calorimeter and electronics system were subjected to testing and calibration at the Fermilab Test Beam Facility. Detailed studies of the energy response and resolution, as well as particle identification capabilities, were performed. The background rate in the actual experimental environment was also examined. The system is found to be well-suited for a dark sector search program on the Fermilab 120 GeV proton beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and commissioning of readout electronics for a $K$$^{0}_{L}$ and $μ$ detector at the Belle II experiment

The K-long and muon detector (KLM) constitutes the outer-most volume of the Belle II spectrometer at the interaction region of the SuperKEKB collider in Tsukuba, Japan. The KLM detector was partially upgraded since the Belle experiment by replacing many of its resistive-plate chambers with scintillators containing wavelength-shifting fibers and instrumenting it with silicon photomultipliers. Here, we describe the readout electronics, firmware, and software created to control and acquire data from the scintillators and resistive-plate chambers.

Belle II↗

A monolithic antineutrino detector for non-intrusive reactor monitoring

Recent advances in organic detection media have found applications in reactor antineutrino physics. One example is the Precision Oscillation and Spectrum Experiment (PROSPECT), which leveraged pulse-shape sensitivity to enable a successful surface deployment at the High Flux Isotope Reactor (HFIR), achieving a signal to background of 4:1. PROSPECT utilized almost 4 tonnes of 6 Li-doped pulse-shape sensitive liquid scintillator in a two-dimensional segmented array. It used a combination of pulse-shape sensitivity and position sensitivity via segmentation to reduce the most prominent form of correlated background for surface detectors — cosmogenic fast neutrons. These new liquids may enable detector designs that bring additional tools for reducing backgrounds while reducing engineering complexity. In this paper, we present an investigation into a detector design that exploits properties of these liquids by maximizing spectral and pulse-shape sensitivity via highly efficient photon detection. The detector utilizes photomultiplier tubes (PMTs) placed at the top and bottom of a right cylinder, with highly reflective white walls. This design sacrifices some position sensitivity for maximal photon efficiency. In conclusion, the design choice has consequences for the identification of the background and antineutrino sensitivity, which we examine.

Pulse shape↗

Performance studies of the Mu2e cosmic ray veto detector

The cosmic ray veto (CRV) detector of the Mu2e experiment consists of four layers of plastic scintillation counters that surround the detector solenoid. These counters are embedded with wavelength-shifting fibers and are read out by silicon photomultipliers (SiPMs). The performance of a subset of the CRV counters was studied in a cosmic-ray test stand. Here, using data taken over a two-year period, we report the single-layer muon detection efficiency and the rate at which the light yield degrades due to the aging of the plastic scintillation counters.

Aging↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

K 2 CuX 3 (X = Cl, Br): All-Inorganic Lead-Free Blue Emitters with Near-Unity Photoluminescence Quantum Yield

Recently, copper(I) halides have been gaining increased attention as highly luminescent nontoxic alternatives to lead halide perovskites for optoelectronic applications. In this paper, we report preparation of blue emitting, lead free, all-inorganic halides K 2 CuX 3 (X = Cl, Br) through five synthetic methods including traditional solid-state and solution methods. The photoluminescence (PL) emission spectra of K 2 CuCl 3 and K 2 CuBr 3 exhibit narrow peaks centered at 392 and 388 nm with full widths at half-maximum (fwhm) values of ~54 nm. The visible bright blue emission is corroborated by the remarkably high photoluminescence quantum yield (PLQY) values up to ~97%. Furthermore, radioluminescence measurements on K 2 CuCl 3 yield a bright peak at 404 nm under irradiation with X-rays at 200 kVp and 20 mA, which is optimal for use with PMTs and Si photomultipliers, suggesting a strong potential of this family for radiation detection applications. Based on our combined experimental and computational investigations, the origin of the efficient luminescence in K 2 CuX 3 is attributed to the high stability self-trapped excitons (STE) formed in the one-dimensional anionic ∞ 1 [CuX 3 ] 2– chains. Advantageously, K 2 CuX 3 demonstrate improved air- and photostability compared to the previously reported copper(I) halides. The discovery of highly efficient and high stability light emitters based on earth-abundant copper(I) halides paves the way for their potential practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-Markovian Hole Excess Noise in Avalanche Amorphous Selenium Thin Films

Enhancing the signal-to-noise ratio in avalanche photodiodes by utilizing impact ionization gain requires materials exhibiting low excess noise factors. Amorphous selenium (a-Se) as a wide bandgap at ~2.1 eV, a solid-state avalanche layer, demonstrates single-carrier hole impact ionization gain and manifests ultralow thermal generation rates. A comprehensive study of the history dependent and non-Markovian nature of hot hole transport in a-Se was modeled using a Monte Carlo (MC) random walk of single hole free flights, interrupted by instantaneous phonon, disorder, hole–dipole, and impact-ionization scattering interactions. The hole excess noise factors were simulated for 0.1–15 μm a-Se thin-films as a function of mean avalanche gain. The hole excess noise factors in a-Se decreases with an increase in electric field, impact ionization gain, and device thickness. The history dependent nature of branching of holes is explained using a Gaussian avalanche threshold distance distribution and the dead space distance, which increases determinism in the stochastic impact ionization process. An ultralow non-Markovian excess noise factor of ~1 was simulated for 100 nm a-Se thin films corresponding to avalanche gains of 1000. Future detector designs can utilize the nonlocal/non-Markovian nature of the hole avalanche in a-Se, to enable a true solid-state photomultiplier with noiseless gain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Highly efficient photoelectric effect in halide perovskites for regenerative electron sources

Electron sources are a critical component in a wide range of applications such as electron-beam accelerator facilities, photomultipliers, and image intensifiers for night vision. We report efficient, regenerative and low-cost electron sources based on solution-processed halide perovskites thin films when they are excited with light with energy equal to or above their bandgap. We measure a quantum efficiency up to 2.2% and a lifetime of more than 25 h. Importantly, even after degradation, the electron emission can be completely regenerated to its maximum efficiency by deposition of a monolayer of Cs. The electron emission from halide perovskites can be tuned over the visible and ultraviolet spectrum, and operates at vacuum levels with pressures at least two-orders higher than in state-of-the-art semiconductor electron sources.

36 MATERIALS SCIENCE↗

Self-powered perovskite photon-counting detectors

Metal-halide perovskites (MHPs) have been successfully exploited for converting photons to charges or vice versa in applications of solar cells, light-emitting diodes and solar fuels for which all these applications involve strong light. Here we show that self-powered polycrystalline perovskite photodetectors can rival the commercial silicon photomultipliers (SiPMs) for photon counting. The photon-counting capability of perovskite photon-counting detectors (PCDs) is mainly determined by shallow traps, despite that deep traps also limit charge-collection efficiency. Two shallow traps with energy depth of 5.8 ± 0.8 millielectronvolts (meV) and 57.2 ± 0.1 meV are identified in polycrystalline methylammonium lead triiodide, which mainly stay at grain boundaries and the surface, respectively. We show that these shallow traps can be reduced by grain-size enhancement and surface passivation using diphenyl sulfide, respectively. It greatly suppresses dark count rate (DCR) from >20,000 counts per second per square millimetre (cps mm –2 ) to 2 cps mm –2 at room temperature, enabling much better response to weak light than SiPMs. The perovskite PCDs can collect γ-ray spectra with better energy resolution than SiPMs and maintain performance at high temperatures up to 85 °C. The zero-bias operation of perovskite detectors enables no drift of noise and detection property. Finally, this study opens a new application of photon counting for perovskites that uses their unique defect properties.

47 OTHER INSTRUMENTATION↗

Highly efficient photon detection systems for noble liquid detectors based on perovskite quantum dots

Abstract Wavelength shifting photon detection systems (PDS) are the critical functioning components in noble liquid detectors used for high energy physics (HEP) experiments and dark matter search. The vacuum ultraviolet (VUV) scintillation light emitted by these Liquid argon (LAr) and liquid Xenon (LXe) detectors are shifted to higher wavelengths resulting in its efficient detection using the state-of-the-art photodetectors such as silicon photomultipliers (SiPM). The currently used organic wavelength shifting materials [such as 1,1,4,4 Tetraphenyl Butadiene (TPB)] have several disadvantages and are unreliable for longterm use. In this study, we demonstrate the application of the inorganic perovskite cesium lead bromide (CsPbBr 3 ) quantum dots (QDs) as highly efficient wavelength shifters. The absolute photoluminescence quantum yield of the PDS fabricated using these QDs exceeds 70%. CsPbBr 3 -based PDS demonstrated an enhancement in the SiPM signal enhancement by up to 3 times when compared to a 3 µm-thick TPB-based PDS. The emission spectrum from the QDs was optimized to match the highest quantum efficiency region of the SiPMs. In addition, we have demonstrated the deposition of the QD-based wavelength shifting material on a large area PDS substrate using low capital cost and widely scalable solution-based techniques providing a pathway appropriate for meter-scale PDS fabrication and widespread use for other wavelength shifting applications.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Air-transfer production method for large-area picosecond photodetectors

We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCPPMT) using the “air-transfer” assembly process developed with single LAPPD TM modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and of hermetically sealing the large-perimeter window–body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume and have shown that the micro-channel plates recover their functionality after cathode synthesis. These steps inform a design for a multi-module batch facility employing dual nested low-vacuum and ultra-high-vacuum systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.

47 OTHER INSTRUMENTATION↗

An all-digital associated particle imaging system for the 3D determination of isotopic distributions

Associated particle imaging (API) is a non-destructive nuclear technique for the 3D determination of isotopic distributions. By detecting the alpha particle associated with the emitted neutron in the deuterium–tritium fusion reaction with a position- and time-resolving detector, the direction of the 14.1 MeV neutron and its time of emission can be determined. Employing this method, isotope characteristic gamma rays emitted in inelastic neutron scattering events can be correlated with the neutron interaction location. Here, an API system consisting of a sealed-type neutron generator, gamma detectors, and a position-sensitive alpha detector was designed, constructed, and characterized. The system was tested with common soil elements and shown to be sensitive to 12 C, 16 O, 28 Si, 27 Al, and 56 Fe. New aspects of our approach are the use of a yttrium–aluminum–perovskite scintillator, using a sapphire window instead of a fiber-optic faceplate for light transport to the photomultiplier, and the all-digital data acquisition system. We present a description of the system with simulations and experimental results that show a position resolution on the alpha detector of 1 mm, a depth resolution using a LaBr 3 detector of 6.2 cm, and an angular resolution of 4.5°. Additionally, we present single-element gamma response measurements for the elements mentioned above together with a comparison to Monte Carlo simulations (MCNP6).

47 OTHER INSTRUMENTATION↗

Fundamental investigation of unipolar and RF corona in atmospheric air

Here, unipolar (DC) and radio frequency (RF) corona at 3.3 MHz is studied at centimeter-sized gaps in a needle-plane geometry in atmospheric air at room temperature. Positive and negative corona using pure tungsten electrodes with varying tip angles revealed a lower onset voltage for the needle with the smaller included angle. The RF corona onset voltage and corresponding time delay were measured for a series of needles composed of pure tungsten or 2% lanthanated tungsten. The corona onset, established when the first instance of UV photon emission is detected via photomultiplier tube, occurred primarily during the negative half cycle of the applied RF voltage for pure tungsten needles. In contrast, with lanthanated tungsten needles, such preference was not observed. No distinguishable difference in onset voltage between pure tungsten and lanthanated tungsten was found, indicating that adding a small amount of lanthanum to tungsten has a negligible impact on the onset voltage at 3.3 MHz frequencies for electrodes at room temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗