At least 289 records · Page 16

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

The Physics and Nuclear Nonproliferation Goals of WATCHMAN: A WAter CHerenkov Monitor for ANtineutrinos

Herein, this article describes the physics and nonproliferation goals of WATCHMAN, the WAter Cherenkov Monitor for ANtineutrinos. The baseline WATCHMAN design is a kiloton scale gadolinium-doped (Gd) light water Cherenkov detector, placed 13 kilometers from a civil nuclear reactor in the United States. In its first deployment phase, WATCHMAN will be used to remotely detect a change in the operational status of the reactor, providing a first- ever demonstration of the potential of large Gd-doped water detectors for remote reactor monitoring for future international nuclear nonproliferation applications. During its first phase, the detector will provide a critical large-scale test of the ability to tag neutrons and thus distinguish low energy electron neutrinos and antineutrinos. This would make WATCHMAN the only detector capable of providing both direction and flavor identification of supernova neutrinos. It would also be the third largest supernova detector, and the largest underground in the western hemisphere. In a follow-on phase incorporating the IsoDAR neutrino beam, the detector would have world-class sensitivity to sterile neutrino signatures and to non-standard electroweak interactions (NSI). WATCHMAN will also be a major, U.S. based integration platform for a host of technologies relevant for the Long-Baseline Neutrino Facility (LBNF) and other future large detectors. This white paper describes the WATCHMAN conceptual design,and presents the results of detailed simulations of sensitivity for the project's nonproliferation and physics goals. Furthermore, it describes the advanced technologies to be used in WATCHMAN, including high quantum efficiency photomultipliers, Water-Based Liquid Scintillator (WbLS), picosecond light sensors such as the Large Area Picosecond Photo Detector (LAPPD), and advanced pattern recognition and particle identification methods.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COHERENT Experiment: current status

The COHERENT Collaboration is realizing a long term neutrino physics research program. The main goals of the program are to detect and study elastic neutrino-nucleus scattering (CEνNS). This process is predicted by Standard Model but it has never been observed experimentally because of the very low energy of the recoil nucleus. COHERENT is using different detector technologies: CsI[Na] and NaI scintillator crystals, a single-phase liquid Ar and a Ge detectors. The placement of all the detector setups is in the basement of the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL). The current status of the COHERENT experimental program is presented.

36 MATERIALS SCIENCE↗

Development and application of InAsP/InP quantum well infrared detector

InAs{sub x}P{sub 1-x}/InP quantum wells grown using metal organic vapor phase epitaxy are investigated for infrared detector applications. The structural parameters of the QWs are evaluated from high resolution x-ray diffraction. The electronic transition energies measured from surface photo voltage and photoconductivity confirms that these QWs can be used for fabricating IR detectors in the wide wavelength range, i.e. 0.9–1.46 µm by inter-band transitions and 7–18 µm by inter-sub-band transitions. Subsequently the functionality of one such fabricated InAs{sub x}P{sub 1-x}/InPQW detector is verified by measuring the photoluminescence of suitable semiconductor quantum well structure. At the request of all authors of the paper, and with the agreement of the Proceedings Editor, an updated version of this article was published on 24 June 2016. The original version supplied to AIP Publishing contained an error in the Figures 1 and 2 where the right side of the images were cutoff. The error has been corrected in the updated and re-published article.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bottom Production from Fixed-Target to Large Hadron Collider Energies

We present a state-of-the-art compilation of the existing bottom production cross sections in elementary collisions, from fixed-target to collider experiments. We then discuss the theoretical uncertainties on the total and differential bottom cross sections in the FONLL approach. In particular, we show total cross sections and kinematical distributions of the bottom hadrons and their decays: B {yields} e/{mu}X, B {yields} D {yields} e/{mu}, and B {yields} J/{psi}X. After seeing that the calculations give a good description of the existing measurements, we present detailed predictions for the LHC experiments in their specific phase space windows. Recent improvements in heavy quark production theory and experimental measurements at colliders, especially for bottom production, have shown that the perturbative QCD framework seems to work rather well, see Refs. [1, 2]. It is important to continue to validate this theoretical framework and its phenomenological inputs, extracted from other measurements, with new data such as that obtained by the CMS collaboration in pp collisions at {radical}s = 7 TeV. We validate the FONLL approach with lower energy data and also compare the results with preliminary LHC data. By showing good agreement between the calculations and the data, we demonstrate we can confidently extrapolate our results to energies appropriate for heavy-ion measurements. Total cross section calculations using the FONLL approach for pp {yields} B{bar B} show excellent agreement across a wide range of {radical}s at both full phase space and CDF phase space. This provides confidence that extrapolating to LHC energies will also show good agreement. Differential cross section FONLL calculations (d{sigma}/dp{sub T} and d{sigma}/d{eta}) at 7 TeV have been compared to preliminary CMS results. The agreement is quite striking. In addition, B fraction calculations have been made that also compare well to the CMS data. This should allow us to expect good agreement between further FONLL calculations and other observables.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Facility for Antiproton and Ion Research and the Compressed Baryonic Matter Experiment

The Compressed Baryonic Matter (CBM) experiment will be one of the major scientific activities at the future Facility for Antiproton and Ion Research (FAIR) in Darmstadt. The goal of the CBM research program is to explore the QCD phase diagram in the region of high baryon densities using high-energy nucleus-nucleus collisions. This includes the study of the equation-of-state of nuclear matter at high densities, and the search for the deconfinement and chiral phase transitions. The CBM detector is designed to measure both bulk observables with large acceptance and rare diagnostic probes such as charmed particles and vector mesons decaying into lepton pairs. The layout and the physics performance of the proposed CBM experimental facility will be discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Binary black hole coalescence in the large-mass-ratio limit: The hyperboloidal layer method and waveforms at null infinity

We compute and analyze the gravitational waveform emitted to future null infinity by a system of two black holes in the large-mass-ratio limit. We consider the transition from the quasiadiabatic inspiral to plunge, merger, and ringdown. The relative dynamics is driven by a leading order in the mass ratio, 5PN-resummed, effective-one-body (EOB), analytic-radiation reaction. To compute the waveforms, we solve the Regge-Wheeler-Zerilli equations in the time-domain on a spacelike foliation, which coincides with the standard Schwarzschild foliation in the region including the motion of the small black hole, and is globally hyperboloidal, allowing us to include future null infinity in the computational domain by compactification. This method is called the hyperboloidal layer method, and is discussed here for the first time in a study of the gravitational radiation emitted by black hole binaries. We consider binaries characterized by five mass ratios, {nu}=10{sup -2,-3,-4,-5,-6}, that are primary targets of space-based or third-generation gravitational wave detectors. We show significative phase differences between finite-radius and null-infinity waveforms. We test, in our context, the reliability of the extrapolation procedure routinely applied to numerical relativity waveforms. We present an updated calculation of the final and maximum gravitational recoil imparted to the merger remnant by the gravitational wave emission, v{sub kick}{sup end}/(c{nu}{sup 2})=0.04474{+-}0.00007 and v{sub kick}{sup max}/(c{nu}{sup 2})=0.05248{+-}0.00008. As a self-consistency test of the method, we show an excellent fractional agreement (even during the plunge) between the 5PN EOB-resummed mechanical angular momentum loss and the gravitational wave angular momentum flux computed at null infinity. New results concerning the radiation emitted from unstable circular orbits are also presented. The high accuracy waveforms computed here could be considered for the construction of template banks or for calibrating analytic models such as the effective-one-body model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A proposed method for electronic feedback compensation of damping in ferromagnetic resonance

Here, we propose an experimental technique for extending feedback compensation of dissipative radiation used in nuclear magnetic resonance (NMR) to encompass ferromagnetic resonance (FMR). This method uses a balanced microwave power detector whose output is phase shifted π/2, amplified, and fed back to drive precession. Using classical control theory, we predict an electronically controllable narrowing of field swept FMR line-widths. This technique is predicted to compensate other sources of spin dissipation in addition to radiative loss.

36 MATERIALS SCIENCE↗

The LUX prototype detector: Heat exchanger development

The LUX (large underground xenon) detector is a two-phase xenon time projection chamber (TPC) designed to search for WIMP–nucleon dark matter interactions. As with all noble element detectors, continuous purification of the detector medium is essential to produce a large (> 1 ms) electron lifetime; this is necessary for efficient measurement of the electron signal which in turn is essential for achieving robust discrimination of signal from background events. Here, we describe the development of a novel purification system deployed in a prototype detector. The results from the operation of this prototype indicated heat exchange with an efficiency above 94% up to a flow rate of 42 slpm, allowing for an electron drift length greater than 1 m to be achieved in approximately 2 days and sustained for the duration of the testing period.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The MAST motional Stark effect diagnostic

A motional Stark effect (MSE) diagnostic is now installed and operating routinely on the MAST spherical tokamak, with 35 radial channels, spatial resolution of {approx}2.5 cm, and time resolution of {approx}1 ms at angular noise levels of {approx}0.5 deg. Conventional (albeit very narrow) interference filters isolate {pi} or {sigma} polarized emission. Avalanche photodiode detectors with digital phase-sensitive detection measure the harmonics of a pair of photoelastic modulators operating at 20 and 23 kHz, and thus the polarization state. The {pi} component is observed to be significantly stronger than {sigma}, in reasonably good agreement with atomic physics calculations, and as a result, almost all channels are now operated on {pi}. Trials with a wide filter that admits the entire Stark pattern (relying on the net polarization of the emission) have demonstrated performance almost as good as the conventional channels. MSE-constrained equilibrium reconstructions can readily be produced between pulses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

XMASS experiment

XMASS is a single phase liquid xenon scintillator detector. The project is designed for multi purposes, dark matter, neutrinoless double beta decay and {sup 7}Be/pp solar neutrino. As the first step of project, XMASS-I detector with 832 kg sensitive volume started operation from Dec. 2010. In this paper, recent obtained physics results from commissioning data, refurbishment of detector and future step of experiment are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode

We demonstrate a method of combining a supercontinuum light source with a commercial Fourier transform spectrometer, using a novel approach to dual-beam balanced detection, implemented with phase-sensitive detection on a single light detector. A 40 dB reduction in the relative intensity noise is achieved for broadband light, analogous to conventional balanced detection methods using two matched photodetectors. Unlike conventional balanced detection, however, this method exploits the time structure of the broadband source to interleave signal and reference pulse trains in the time domain, recording the broadband differential signal at the fundamental pulse repetition frequency of the supercontinuum. The method is capable of real-time correction for instability in the supercontinuum spectral structure over a broad range of wavelengths and is compatible with commercially designed spectrometers. A proof-of-principle experimental setup is demonstrated for weak absorption in the 1500-1600 nm region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WIDE-BAND SUZAKU ANALYSIS OF THE PERSISTENT EMISSION FROM SGR 0501+4516 DURING THE 2008 OUTBURST

We observed the soft gamma repeater SGR 0501+4516 with Suzaku for {approx}51 ks on 2008 August 26-27, about 4 days after its discovery. Following the first paper, which reported on the persistent soft X-ray emission and the wide-band spectrum of an intense short burst, this paper presents an analysis of the persistent broadband (1-70 keV) spectra of this source in outburst, taken with the X-ray Imaging Spectrometer (XIS) and the Hard X-ray Detector (HXD). Pulse-phase folding in the 12-35 keV HXD-PIN data on an ephemeris based on multi-satellite timing measurements at soft X-rays revealed the pulsed signals at {approx_gt}99% confidence in the hard X-ray band. The wide-band spectrum clearly consists of a soft component and a separate hard component, crossing over at {approx}7 keV. When the soft component is modeled by a blackbody plus a Comptonized blackbody, the hard component exhibits a 20-100 keV flux of 4.8{sup +0.8}{sub -0.6}(stat.){sup +0.8}{sub -0.4}(sys.) x 10{sup -11} erg s{sup -1} cm{sup -2} and a photon index of {Gamma} = 0.79{sup +0.20}{sub -0.18}(stat.){sup +0.01}{sub -0.06}(sys.). The hard X-ray data are compared with those obtained by INTEGRAL about 1 day later. Combining the present results with those on other magnetars, we discuss a possible correlation between the spectral hardness of magnetars and their characteristic age and magnetic field strengths.

79 ASTRONOMY AND ASTROPHYSICS↗

Supernova neutrino detection in LZ

In the first 10 seconds of a core-collapse supernova, almost all of its progenitor's gravitational potential, O(10 53 ergs), is carried away in the form of neutrinos. These neutrinos, with O(10 MeV) kinetic energy, can interact via coherent elastic neutrino-nucleus scattering (CEνNS) depositing O(1 keV) in detectors. In this work we describe the performances of low-background dark matter detectors, such as LUX-ZEPLIN (LZ), optimized for detecting low-energy depositions, in detecting these neutrino interactions. For instance, a 27 M ⊙ supernova at 10 kpc is expected to produce ~350 neutrino interactions in the 7-tonne liquid xenon active volume of LZ. Based on the LS220 EoS neutrino flux model for a SN, the Noble Element Simulation Technique (NEST), and predicted CEνNS cross-sections for xenon, to study energy deposition and detection of SN neutrinos in LZ. Here we simulate the response of the LZ data acquisition system (DAQ) and demonstrate its capability and limitations in handling this interaction rate. We present an overview of the LZ detector, focusing on the benefits of liquid xenon for supernova neutrino detection. We discuss energy deposition and detector response simulations and their results. We present an analysis technique to reconstruct the total number of neutrinos and the time of the supernova core bounce.

47 OTHER INSTRUMENTATION↗

Strong Einstein-Podolsky-Rosen entanglement from a single squeezed light source

Einstein-Podolsky-Rosen (EPR) entanglement is a criterion that is more demanding than just certifying entanglement. We theoretically and experimentally analyze the low-resource generation of bipartite continuous-variable entanglement, as realized by mixing a squeezed mode with a vacuum mode at a balanced beam splitter, i.e., the generation of so-called vacuum-class entanglement. We find that in order to observe EPR entanglement the total optical loss must be smaller than 33.3 %. However, arbitrarily strong EPR entanglement is generally possible with this scheme. We realize continuous-wave squeezed light at 1550 nm with up to 9.9 dB of nonclassical noise reduction, which is the highest value at a telecom wavelength so far. Using two phase-controlled balanced homodyne detectors we observe an EPR covariance product of 0.502{+-}0.006<1, where 1 is the critical value. We discuss the feasibility of strong Gaussian entanglement and its application for quantum key distribution in a short-distance fiber network.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complete parametrizations of diffusive quantum monitorings

The master equation for the state of an open quantum system can be unravelled into stochastic trajectories described by a stochastic master equation. Such stochastic differential equations can be interpreted as an update formula for the system state conditioned on results obtained from monitoring the bath. So far only one parametrization (mathematical representation) for arbitrary diffusive unravellings (quantum trajectories arising from monitorings with Gaussian white noise) of a system described by a master equation with L Lindblad terms has been found [H. M. Wiseman and A. C. Doherty, Phys. Rev. Lett. 94, 070405 (2005)]. This parametrization, which we call the U representation parameterizes diffusive unravellings by L{sup 2}+2L real numbers, arranged in a matrix U subject to three constraints. In this paper we investigate alternative parametrizations of diffusive measurements. We find, rather surprisingly, the description of diffusive unravellings can be unified by a single equation for a nonsquare complex matrix M if one is willing to allow for some redundancy by lifting the number of real parameters necessary from L{sup 2}+2L to 3L{sup 2}+L. We call this parametrization the M representation. Both the M representation and U representation lack a physical picture of what the measurement should look like. We thus propose another parametrization, the B representation that details how the measurement is implemented in terms of beam-splitters, phase shifters, and homodyne detectors. Relations between the different representations are derived.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Near-field limitations of Fresnel-regime coherent diffraction imaging

Coherent diffraction imaging (CDI) is a rapidly developing form of imaging that offers the potential of wavelength-limited resolution without image-forming lenses. In CDI, the intensity of the diffraction pattern is measured directly by the detector, and various iterative phase retrieval algorithms are used to “invert” the diffraction pattern and reconstruct a high-resolution image of the sample. But, there are certain requirements in CDI that must be met to reconstruct the object. Although most experiments are conducted in the “far-field”—or Fraunhofer—regime where the requirements are not as stringent, some experiments must be conducted in the “near field” where Fresnel diffraction must be considered. According to the derivation of Fresnel diffraction, successful reconstructions can only be obtained when the small-angle number, a derived quantity, is much less than one. We show, however, that it is not actually necessary to fulfill the small-angle condition. The Fresnel kernel well approximates the exact kernel in regions where the phase oscillates slowly, and in regions of fast oscillations, indicated by large A n , the error between kernels should be negligible due to stationary-phase arguments. Finally we verify, by experiment, this conclusion with a helium neon laser setup and show that it should hold at x-ray wavelengths as well.