Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PERFORM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Understanding Strong Scaling on GPUs Using Empirical Performance Saturation Size

The roofline model provides a concise overview of the maximum performance capabilities of a given computer system through a combination of peak memory bandwidth and compute performance rates. The increasing complexity of scheduling and cache in recent GPUs, however, has introduced complicated performance variability that is not captured by arithmetic intensity alone. This work examines the effect of problem size and GPU launch configurations on roofline performance for V100, A100, MI100, and MI250X graphics processing units. We introduce an extended roofline model that takes problem size into account, and find that strong scaling on GPUs can be characterized by saturation problem sizes as additional key metrics. Saturation problem sizes break up a plot of GPU performance vs. problem size into three distinct performance regimes– size-limited, cache-bound, and DRAM-bound. With our extended roofline model, we are able to provide a robust view of these performance regimes across recent GPU architectures.

Eberius, David↗

Performance Debugging and Tuning of Flash-X with Data Analysis Tools

State-of-the-art multiphysics simulations running on large scale leadership computing platforms have many variables contributing to their performance and scaling behavior. We recently encountered an interesting performance anomaly in Flash-X, a multiphysics multicomponent simulation software, when characterizing its performance behavior on several large-scale HPC platforms. The anomaly was tracked down to the interaction between the use of dynamic allocation of scratch data and data locality in the cache hierarchy. In this paper we present the details of unexpected performance variability of Flash-X, its extensive analysis using the performance measurement tool TAU to collect the data and Python data analysis libraries to explore the data, and our insights from this experience. In this process, we discovered and removed or mitigated two additional performance limiting bottlenecks for performance tuning.

Huck, Kevin↗

Automatic Generation of High-Performance Convolution Kernels on ARM CPUs for Deep Learning

In this work, we present FastConv, a template-based code auto-generation open source library that can automatically generate high-performance deep learning convolution kernels of arbitrary matrices/tensors shapes. FastConv is based on the Winograd algorithm, which is reportedly the highest performing algorithm for the time-consuming convolution layers of convolutional neural networks. ARM CPUs cover a wide range designs and specifications, from embedded devices to HPC-grade CPUs. The leads to the dilemma of how to consistently optimize Winograd-based convolution solvers for convolution layers of different shapes. FastConv addresses this problem by using templates to auto-generate multiple shapes of tuned kernels variants suitable for skinny tall matrices. As a performance portable library, FastConv transparently searches for the best combination of kernel shapes, cache tiles, scheduling of loop orders, packing strategies, access patterns, and online/offline computations. Auto-tuning is used to search the parameter configuration space for the best performance for a given target architecture and problem size. The experiments with layer-wise evaluation on the VGG--16 model confirms a 1.25x performance gains is got by tuning the Winograd library. Integrated comparison results shows 1.02x to 1.40x, 1.14x to 2.17x, and 1.22x and 2.48x speedup is achieved over NNPACK, Arm NN, and FeatherCNN on the Kunpeng 920 beside few cases. Furthermore, problem size performance portability experiments with various convolution shapes shows that FastConv achieves 1.2x to 1.7x speedup and 2x to 22x speedup over NNPACK and ARM NN inference engine using Winograd on Kunpeng 920 . CPU performance portability evaluation on the VGG--16 show an average speedup over NNPACK of 1.42x, 1.21x, 1.26x, 1.37x, 2.26x, and 11.02x is observed on Kunpeng 920, Snapdragon 835, 855, 888, Apple M1, and AWS Graviton2, respectively.

97 MATHEMATICS AND COMPUTING↗

Editors’ Choice—Examining Performance and Durability of Anion Exchange Membrane Fuel Cells with Novel Spirocyclic Anion Exchange Membranes

A series of spirocyclic copolymer membranes with varying ion exchange capacities (IECs) were investigated to probe the impact of polymer properties on in situ fuel cell performance and stability. In-situ electrochemical tests and post-mortem electron microscopy analysis of cross-sectioned membrane electrode assemblies (MEAs) have been combined with voltage loss breakdown analysis to evaluate the performance and degradation of different MEAs, and to probe the catalyst morphology and electrode structure at different stages of operation. Voltage loss breakdown results show that membrane degradation and kinetic losses played only a minor role in observed performance degradation and that performance losses were primarily related to increasing mass transport losses. From microscopy studies, carbon corrosion and Pt nanoparticle growth were identified at both the cathode and anode although more pronounced on the cathode resulting in significant structural changes. The membrane with the lowest IEC (1.3 mmolg −1 ) demonstrated the lowest peak power density ~ 1.16 W cm −2 , however, it showed the most stable performance (constant 0.6 A cm −2 hold) with ~ 5% degradation over 540 h. Isolation of performance losses and microscopic analysis of electrodes for anion exchange membrane fuel cells has not been reported previously, and these results help identify critical performance degradation concerns.

25 ENERGY STORAGE↗

COVID-19 global pandemic planning: Performance and electret charge of N95 respirators after recommended decontamination methods

Shortages of N95 respirators for use by medical personnel have driven consideration of novel conservation strategies, including decontamination for reuse and extended use. Decontamination methods listed as promising by the Centers for Disease Control and Prevention (CDC) (vaporous hydrogen peroxide (VHP), wet heat, ultraviolet irradiation (UVI)) and several methods considered for low resource environments (bleach, isopropyl alcohol and detergent/soap) were studied for two commonly used surgical N95 respirators (3M™ 1860 and 1870+ Aura™). Although N95 filtration performance depends on the electrostatically charged electret filtration layer, the impact of decontamination on this layer is largely unexplored. As such, respirator performance following decontamination was assessed based on the fit, filtration efficiency, and pressure drop, along with the relationship between (1) surface charge of the electret layer, and (2) elastic properties of the straps. Decontamination with VHP, wet heat, UVI, and bleach did not degrade fit and filtration performance or electret charge. Isopropyl alcohol and soap significantly degraded fit, filtration performance, and electret charge. Pressure drop across the respirators was unchanged. Modest degradation of N95 strap elasticity was observed in mechanical fatigue testing, a model for repeated donnings and doffings. CDC recommended decontamination methods including VHP, wet heat, and UV light did not degrade N95 respirator fit or filtration performance in these tests. Extended use of N95 respirators may degrade strap elasticity, but a loss of face seal integrity should be apparent during user seal checks. NIOSH recommends performing user seal checks after every donning to detect loss of appropriate fit. Decontamination methods which degrade electret charge such as alcohols or detergents should not be used on N95 respirators. The loss of N95 performance due to electret degradation would not be apparent to a respirator user or evident during a negative pressure user seal check.

60 APPLIED LIFE SCIENCES↗

Performance and community structure dynamics of microbial electrolysis cells operated on multiple complex feedstocks

Microbial electrolysis is a promising technology for converting aqueous wastes into hydrogen. However, substrate adaptability is an important feature, seldom documented in microbial electrolysis cells (MECs). In addition, the correlation between substrate composition and community structure has not been well established. This study used an MEC capable of producing over 10 L/L-day of hydrogen from a switchgrass-derived bio-oil aqueous phase and investigated four additional substrates, tested in sequence on a mature biofilm. The additional substrates included a red oak-derived bio-oil aqueous phase, a corn stover fermentation product, a mixture of phenol and acetate, and acetate alone. The MECs fed with the corn stover fermentation product resulted in the highest performance among the complex feedstocks, producing an average current density of 7.3 ± 0.51 A/m 2 , although the acetate fed MECs outperformed complex substrates, producing 12.3 ± 0.01 A/m 2 . 16S rRNA gene sequencing showed that community structure and community diversity were not predictive of performance, and replicate community structures diverged despite identical inoculum and enrichment procedure. The trends in each replicate, however, were indicative of the influence of the substrates. Geobacter was the most dominant genus across most of the samples tested, but its abundance did not correlate strongly to current density. High-performance liquid chromatography (HPLC) showed that acetic acid accumulated during open circuit conditions when MECs were fed with complex feedstocks and was quickly degraded once closed circuit conditions were applied. The largest net acetic acid removal rate occurred when MECs were fed with red oak bio-oil aqueous phase, consuming 2.93 ± 0.00 g/L-day. Principal component analysis found that MEC performance metrics such as current density, hydrogen productivity, and chemical oxygen demand removal were closely correlated. Net acetic acid removal was also found to correlate with performance. However, no bacterial genus appeared to correlated to these performance metrics strongly, and the analysis suggested that less than 70% of the variance was accounted for by the two components. This study demonstrates the robustness of microbial communities to adapt to a range of feedstocks and conditions without relying on specific species, delivering high hydrogen productivities despite differences in community structure. The results indicate that functional adaptation may play a larger role in performance than community composition. Further investigation of the roles each microbe plays in these communities will help MECs to become integral in the 21st-century bioeconomy to produce zero-emission fuels.

09 BIOMASS FUELS↗

Multi-contrast machine learning improves schistosomiasis diagnostic performance

Schistosomiasis currently affects over 250 million people and remains a public health burden despite ongoing global control efforts. Conventional microscopy is a practical tool for diagnosis and screening ofSchistosoma haematobium, but identification of eggs requires a skilled microscopist. Here we present a machine learning (ML)-based strategy for automated detection ofS. haematobiumthat combines two imaging contrasts, brightfield (BF) and darkfield (DF), to improve diagnostic performance. We collected BF and DF images of urine samples, many of them containingS. haematobiumeggs, during two different field studies in Côte d’Ivoire using a mobile phone-based microscope, the SchistoScope. We then trained separate egg-detection ML models and compared the patient-level performance of BF and DF models alone to combinations of BF and DF models, using annotations from trained microscopists as the gold standard. We found that models trained on DF images, and almost all BF and DF combinations, performed significantly better than models trained on BF images only. When models were trained on images from the first field study (n = 349 patients, 748 images of each contrast), patient-level classification performance on patient images from the second study (n = 375 patients, 752 images of each contrast) met the WHO Diagnostic Target Product Profile (TPP) sensitivity and specificity for the monitoring and evaluation use case (sensitivity for all models and combinations was >75% when evaluated at a confidence score threshold that resulted in specificity >96.5%). When we used images from both field studies for the training set, performance of the models was improved. Overall, this work shows that the use of DF and BF increases the performance of ML models on images from devices with low-cost optics, while retaining the portability, power, and time-to-results of the WHO’s diagnostic TPP. DF requires no additional sample preparation and does not increase the complexity of the imaging system. It thus offers a practical means to improve performance of automated diagnostics forS. haematobiumas well as other microscopy-based diagnostics.

Infectious Diseases↗

Evaluation of “Tight Oil” Well Performance and Completion Practices in the Powder River Basin - “Time Slice” Analysis

The objective of this paper is to assess how well completion practices and well performance have evolved over time (“time slices”) in the tight sands and shales of the Powder River Basin (PRB). This information can provide a foundation for helping operators define more effective well completion practices and thus optimize well performance in an emerging “tight oil” basin. To start, the authors assembled a “database” containing well completion practices, production data, and geologic information for more than 800 horizontal (Hz) wells targeting three “tight oil” formations -- Turner, Frontier, and Mowry--placed on production in the past dozen years. To control for the impact of geologic and reservoir properties on well performance, the authors defined 12 geologically distinct areas (“partitions”) for the Turner, Frontier, and Mowry Shale in the Powder River Basin (4 partitions in each formation). This paper discusses the methodology for establishing “time slices” for each partition within each of the three “tight oil” formations, including (1) taking out, to the extent practical, the effects of geology by partitioning the three “tight oil” formations based on their geologic parameters; (2) using type curves and estimated ultimate recoveries (EURs) to establish a reliable measure of well performance; and (3) rigorously inspecting the production and well completion data to assure a quality dataset. Partition #2, a high thermal maturity area of the Frontier Sandstone in the western Powder River Basin, helps illustrate the results of the study. Using a dataset of 55 Hz wells, the study found that well performance has steadily improved, with oil EURs increasing from 180 MBbl in 2012-13 to 290 MBbl in 2018-19. Much of this improvement was due to the use of longer Hz laterals, increasing notably from 3,765 ft in 2012-13 to 10,260 ft in 2018-19. More intensive completion practices contributed, as well. For example, the number of frac stages more than doubled, from 17 to 35, and proppant concentrations increased from 1,060 lbs/ft to 1,320 lbs/ft. Finally, the data show diminishing returns to longer laterals and more intensive completion practices. For example, the key performance measure of oil EUR per 1,000 ft of lateral is decreasing. For 2012-13, Hz wells recovered 50 MBbl of oil per 1,000 ft of lateral while the more recent 2018-19 Hz wells only provide 30 MBbl of oil per 1,000 ft of lateral. Considerable insight can be gained by using “time slices” and geologic partitioning to better understand the relationship between changes in well drilling and completion practices and changes in well performance in emerging “tight oil” plays. The results from this study can also serve as a foundation for subsequent, more intense efforts involving data analytics for defining more optimum well completion practices targeting specified geologic settings and formations.

02 PETROLEUM↗

Cesium Removal Performance Comparisons of Crystalline Silicotitanate Media Batches with Savannah River Site Waste Simulant

The Tank Closure Cesium Removal (TCCR) system uses ion exchange columns filled with Crystalline Silicotitanate (CST) media to process radioactive waste solutions for the removal of Cs137. TCCR currently focuses on dissolving Savannah River Site (SRS) Tank 10H waste (primarily sodium salt cake solids) within the tank followed by at-tank ion exchange column treatment. Plans are underway to prepare and install a second TCCR unit at SRS. Capacity and particle size differences exist between archived (IE-911) and more recently-prepared CST media batches (9120- B and 9140-B). Side-by-side comparison testing was performed to evaluate the cesium removal performance of each batch to aid in selecting the preferred CST batch and media characteristics to load into the second TCCR unit. Batch contact equilibrium and flow-through column tests have been conducted with three CST batches using an SRS Average Simulant. Simulant batch contact equilibrium cesium loading results for the three CST batches (including two lots of one batch) are provided in Table ES-1. The 35 °C data indicates that the archived IE-911 batch has a higher cesium capacity than recently-prepared CST media and that the minor TCCR CST 9120-B media lot (2099000035) has similar cesium removal performance to the major TCCR lot (2099000034). Tests conducted at 25 ºC for the archived IE-911 CST batch indicated lower cesium removal performance with this simulant batch than was observed recently with a different SRS Average Simulant batch. A dilution factor (DF) is typically utilized when modeling engineered CST media cesium loading performance to account for mass contributions from the binder material. In cases where CST performance is lower than expected, this factor includes corrections for the binder and for low performance. The ZAM (Zheng, Anthony, and Miller) Isotherm Model DF values are provided in Table ES-1 for each simulant batch contact result. DF values near 0.5 were determined for the 9120-B and 9140-B CST batch contact tests while DF values near 0.6 (20% higher) were determined for the tests with IE-911. These dilution factors are lower than recently observed with a different SRS Average Simulant batch (9140-B DF = 0.68; IE-911 DF = 1.0). Based on these results, it appears that some component in the simulant solution used for equilibrium testing may have resulted in reduced cesium loading on the CST media.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving the performance of medical imaging applications using SYCL

As opposed to the Open Computing Language (OpenCL) programming model, in which host and device codes are generally written in different programming languages, SYCL can combine host and device codes for an application in a type-safe way to improve development productivity and performance portability. Hence, this report shows the experimental results of applying the SYCL programming model to medical imaging applications for a study on performance portability and programming productivity between OpenCL and SYCL. Rodinia is a widely used open-source benchmark suite for heterogeneous computing. We choose two medical imaging applications (Heart Wall and Particle Filter) in the benchmark suite, migrate the OpenCL implementations of the applications to the SYCL implementations, and evaluate their performance and productivity on Intel® microprocessors that contain a central processing unit (CPU) and an integrated graphics processing unit (GPU). The maturing SYCL compilers, which are based on a conformant implementation of the SYCL 1.2.1 Khronos specification, have been actively optimized for Intel® computing platforms. The experimental results are promising in terms of the raw performance and productivity. Although the SYCL implementation of the Heart Wall application does not execute successfully on a CPU, the SYCL implementations of the application can achieve comparable or better performance than the OpenCL implementation on Intel® integrated GPUs. For the Particle Filter application, the performance difference between the SYCL and OpenCL implementations is comparable on the GPUs for most cases, but the SYCL implementations are on average 4X faster than the OpenCL implementations on Intel® Xeon® CPUs. For programming productivity, we arguably use lines of code as a way to measure programming productivity in software. The SYCL programs reduce the lines of code of the OpenCL programs by 52% and 38% for the Heart Wall and Particle Filter, respectively. The results indicate that SYCL is a promising programming model for heterogeneous computing with the maturing compilers. We organize the remainder of the report as follows. Section II introduces the SYCL programming model, compares the major differences between an OpenCL program and a SYCL program, and describes the characteristics of the two applications. Section III describes the SYCL programming model in more details, and shows the SYCL implementation of a kernel function in the Particle Filter application as an example. In Section IV, we evaluate the performance of the applications on the CPUs and GPUs. Section V concludes the report.

59 BASIC BIOLOGICAL SCIENCES↗

Performance Assessments of Demand Flexibility from Grid-Interactive Efficient Buildings: Issues and Considerations

This SEE Action Network report explains basic concepts and fundamental considerations for assessing the actual demand flexibility performance of buildings participating in demand flexibility programs and responding to time-varying retail rates. Demand flexibility is the capability of distributed energy resources (DERs) to adjust a building’s load profile across different timescales. Assessments determine the timing, location, quantity, and quality of grid services provided. The results can be used for financial settlements and to improve performance of demand flexibility, support its consideration in resource potential studies and electricity system planning, and contribute to cost-effectiveness evaluations. While practitioners and regulators regularly find opportunities to improve performance assessments of demand-related services, to a large degree current best practices are sufficient for basic service offerings as demand flexibility is implemented today. However, advances in assessment practices will be required in a future with grid-interactive efficient buildings (GEBs) that provide continuous demand flexibility by integrating multiple DERs and flexibility modes (load shed, load shift, modulate, and generate). Example practices include using new baseline constructs—including whether baselines are even required for certain building flexibility modes or configurations, deploying more advanced metering and analytics, further developing cybersecurity standards, improving communication standards for increased interoperability, and establishing performance metrics and assessment procedures for load modulation as it is more fully defined and implemented. This report provides information on prioritizing and designing performance assessment elements for demand flexibility programs and time-varying retail rates, assessment protocols, and research and development needs. Additional research sponsored by DOE’s Building Technologies Office offers more detailed technical information on assessing performance of demand flexibility, including definition of performance metrics.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Criteria for Capture and/or Immobilization Technologies (Revision 1)

The capture and subsequent immobilization of regulated volatile radionuclides from the off-gas streams of a used nuclear fuel (UNF) reprocessing facility has been a topic of substantial research interest for the US Department of Energy and its international counterparts. Removal of specific radionuclides from the plant effluent streams before discharge to the environment is required to meet regulations set forth by the US Environmental Protection Agency. Upon removal, the radionuclides, as well as associated sorbents that cannot be regenerated in a cost-effective manner, are destined for conversion to a waste form. Research in separation and capture methodologies has included a wide range of technology types, and studies of waste forms are correspondingly diverse. In considering the future development and implementation of both sorbents and waste forms, it is necessary to identify benchmark measures of performance to objectively evaluate each sorbent system or waste form. Sets of performance criteria and associated metrics have been developed for sorbent and waste form evaluation. These criteria address physical, radiological, and chemical characteristics, technical practicality, technical maturity, cost, and, for sorbents, system performance. The criteria and metrics appear to be robust and should be applicable despite the eventual waste classification (as either high- or low-level waste). They are flexible enough to address both aqueous reprocessing and electrochemical reprocessing of UNF. These criteria sets can serve as tools to evaluate performance at multiple stages within the development process, and in this revision (Revision 1) they have been used to assess technologies relating to krypton/xenon separations and iodine capture from off-gas streams arising from UNF reprocessing. Assessment of krypton/xenon separations using engineered forms of two zeolite minerals (silver mordenite and hydrogen mordenite in a polyacrylonitrile-based binder [AgZ-PAN/HZ-PAN]) found that the zeolite-based separation is relatively advanced in its development, but several key issues require resolution. First, desorption processes for both krypton and xenon require refinement to provide an understanding of the product purity that can be achieved. Second, adsorption rate data is needed in order to calculate the bed depth required for effective separation. Finally, it is strongly recommended that a technical review of krypton/xenon separation by AgZ-PAN/HZ-PAN be performed to synergize available data and assess the cost savings and operational benefits that may be realized from implementation of this technology. Assessment of metal organic frameworks (MOFs) for their use in the separation of krypton/xenon found that the ideal separation would be performed using a single-column system with a MOF selective for krypton over xenon. A robust research effort should work to identify a krypton-selective MOF designed to operate at temperatures of approximately 0°C or higher, which could be preferred over cryogenic krypton/xenon capture for used fuel reprocessing off-gas streams. In the case of the CaSDB-MOF (the most well-understood xenon sorbent to date), two issues are judged of high importance. First, xenon breakthrough capacity for the CaSDB-MOF in prototypical conditions should be determined. Preliminary research indicates that breakthrough may be near immediate, presenting a substantial obstacle in separative system design. Second, development of desorption methodology should be performed to determine regeneration time, energy requirements, and the product stream composition. Silver-based sorbents (AgZ and AgAero) for use in iodine capture from the dissolver off-gas were evaluated against the established criteria. These sorbents are significantly better understood for this application as a result of research efforts over the past decade. The potential implementation of AgAero at a large scale is hindered by its physical degradation by components of the dissolver off-gas stream. Less is known about the adsorption of iodine by these sorbents from other off-gas streams in the plant. Initial experimental efforts have been closely coordinated in an effort to understand organic iodine (such as would be found in the vessel off-gas) adsorption by AgZ and AgAero. Future work should expand this experimental program, and analysis of other reprocessing facility off-gas streams such as the vitrification off-gas stream should be conducted to better understand other potential applications for iodine sorbents. A review of iodine waste form development shows that this area is diverse and that multiple promising waste forms have been identified for the immobilization of radioactive iodine. Efforts related to the direct conversion of iodine sorbents (including AgZ and AgAero) should be continued because of the advantages of direct conversion in a waste management strategy and other sorbents should continue to be advanced as merited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High Performance SOFCs with a Superior Stability for Reliable and Durable Power Systems

Next generation of fuel cells, electrolyzers, and batteries requires higher power, faster kinetics, and larger energy density, which necessitate the use of compositionally complex oxides to achieve multifunctionalities and activity. These compositionally complex oxides may change their phases and structures during an electrochemical process – a so-called “electrochemically driven phase transformation”. The origin for such a phase change has remained obscure. More importantly, there is a need to develop high performance solid oxide fuel cells with an enhanced stability. In this work, the La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) cathode surface is modified by infiltration of Pr 6 O 11 and the power density at 0.8V and 750 °C is improved by 21%. In addition, by replacing the traditional barrier layer Gd 0.2 Ce 0.8 O 1.9 with mixed conducting Pr 0.1 Gd 0.1 Ce 0.8 O 1.9 , the power density increases by 38%. The different mechanism of promotions was investigated by electrochemical impedance spectroscopy. The ohmic resistance is dramatically reduced by applying the PGCO interlayer, and the distribution of relaxation time was used to analyze the mechanism for which the polarization resistance was decreased attributing to the mixed conduction nature in PrO x . An increase of power density at 0.8 V of 0.358 W/cm 2 (71%) is achieved with the implementation of both surface modification and buffer layer engineering. An experimental study and a theoretical analysis were then carried out on phase evolution in praseodymium nickelates. Nickelate-based electrodes show up to 60× greater phase transformation during operation when compared to thermally annealed ones. Theoretical analysis suggests that the presence of a reduced oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is the origin for the phase change in an oxygen electrode. Guided by the theory, an addition of the electronic conduction in the interface layer leads to the significant suppression of phase change, while improving cell performance and performance stability. When an oxygen electrode is under polarization, the oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is lower than that of incoming oxidant. Under a high polarization, the environment at the aforementioned interface may lead to phase transformation of the oxygen electrode. The local oxygen partial pressure is determined by the transport properties at the interfaces. An addition of the electronic conduction in the interface layer, for instance using (Pr,Gd)-doped ceria to replace Gd-doped ceria, results in improved cell performance and performance stability, while the phase transformation is significantly suppressed. This work provides a fundamental understanding of the origin for phase transformation in oxygen electrodes during operation and use this knowledge to develop a high-performance electrode that exhibits improved performance stability.

30 DIRECT ENERGY CONVERSION↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Monitoring Program: Developing Comparative Metrics for Fitness-for-Duty Programs

To comply with U.S. Nuclear Regulatory Commission (NRC) regulations, licensees and entities authorized under Title 10 of the Code of Federal Regulations (CFR) Part 26 Section 26.3 (§ 26.3) are required to have fitness-for-duty (FFD) programs. Under § 26.3, the expectation of these FFD programs is to provide reasonable assurance that individuals who are granted unescorted access to nuclear power reactor protected areas and Category I fuel cycle facility material control areas are trustworthy, will perform their tasks in a reliable manner, are not under the influence of any substance, legal or illegal, that may impair their ability to perform their duties, and are not mentally or physically impaired from any cause that can adversely affect their ability to safely and competently perform their duties. Pacific Northwest National Laboratory (PNNL) was tasked with developing a performance monitoring program to risk inform NRC inspection and policy regarding quantitative FFD performance data. To meet this need, PNNL developed methodologies that could be implemented within a performance monitoring program. Throughout this report, these methodologies are referred to as comparative metrics. The NRC provided PNNL with 2016–2019 data from annual reporting forms and single positive test forms provided by licensees and other entities. For most of the comparative metrics, the analyses required customized processing, such as creating filtering fields, adding data fields and summaries, and joining datasets. The comparative metrics developed include: random testing rate, random policy violation rate, pre-access policy violation rate, subversion attempt rate, and number of policy violations by labor category. The comparative metrics can be used for parsing and visualizing FFD program data and monitoring FFD performance at the labor category, facility, licensee, and industry levels to risk inform NRC inspection and policy with regard to the FFD data currently collected from licensees and other entities that implement Part 26 requirements. Furthermore, these developed comparative metrics allow a more in-depth look at the FFD programs for the industry to discern trends and patterns that may warrant changes at an industry level and to inform policy decisions. These analyses should be refreshed as new FFD data become available.

99 GENERAL AND MISCELLANEOUS↗

Comparison of the Neutronic Performance of IRP-1 and IRP-2 at SNS

The Spallation Neutron Source (SNS) operated from start-up, in May 2006, through December, 2017 before replacing the Inner Reflector Plug (IRP). This component is the most costly and time-consuming “regular maintenance” replacement foreseen in the operation of the First Target Station (FTS). The IRP includes beryllium reflector blocks, steel and aluminum support structures, aluminum moderator vessels (which in turn include gadolinium and cadmium neutron poisons) and water coolant systems. The lifetime of this multi-million dollar component is driven by poison and decoupler burnup in moderator vessels. The moderators include these neutron poisons to best match neutron beam performance with scattering instrument needs. The burnup that comes with use changes the performance of the moderators until they no longer server their intended purpose. The reasonable desire to maximize the IRP lifetime means that the moderator performance at the Beginning Of Life (BOL) is significantly “over poisoned” and different from the performance at moderator End Of Life (EOL). Upon installation of the second IRP article, IRP-2, the SNS Neutronics team characterized the performance of the neutron beamlines in order to assess the differences between them, primarily by comparing the EOL performance of IRP-1 to the BOL performance of IRP-2. While IRP-2 was largely similar to IRP-1 in its conceptual design, there were some differences in the specific design of IRP-2 to support enhanced manufacturability, and the change from IPR-1 to IRP-2 coincided with the replacement of the light water in the IRP cooling loop with heavy water, as had been intended in the SNS design but not implemented during construction because of heavy water availability.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An Online Prototype Toolset for Predicting and Optimizing P&T Performance (FY23 Status Report)

A new web-based toolset is being developed to support ongoing remediation optimization efforts and implementation of an adaptive site management strategy for the 200 West Area Pump-and-Treat (P&T) system at the Hanford Site. This toolset, comprising the well performance index tool and the well optimization pre-screening tool, will offer a user-friendly interface to predict and optimize the P&T well network’s performance at a preliminary level. Efforts in fiscal year (FY) 2023 focused on three main components: updating the existing deep learning model for predicting P&T performance, designing and developing a prototype of a web-based performance index tool, and initiating the conceptual design of the well optimization pre-screening tool. The well performance index tool is based on a pre-trained deep learning model that allows users to select a target contaminant and well screen length, then visualize the predicted performance of potential new wells across the site. The well optimization pre-screening tool includes two separate modules: the pre-computed scenario viewer, which organizes and visualizes offline optimization simulation results, and the quick analysis module, which provides real-time model prediction using user-specified well locations. In FY24, the plan is to add web-based applications to SOCRATES for both the well performance prediction tool and the optimization prescreening tool, with accompanying user and theory guides. These tools are intended to enable an accessible, easily applied, and transparent approach to remedy planning and decision-making.

97 MATHEMATICS AND COMPUTING↗

Performance Demonstration of an Occupancy Sensor-enabled Integrated Solution for Commercial Buildings

Traditionally, a single-loop fixed-gain controller is applied to supply fan (SF) and cooling coil (CC) valve controls while a fixed-damper position control is applied to outdoor air (OA) damper control at air handling units (AHUs) in commercial buildings. With the increasing application of occupancy sensors, the information generated by occupancy sensors is applied to not only reduce the electricity loads from lighting and controllable plug loads, but also reset OA intake and minimum supply airflow setpoints. Meanwhile, these intermittent operation actions greatly elevate the dynamics of AHU systems, which may introduce unstable SF and CC valve operations and inaccurate OA flow control at AHUs and consequently degrade maximum energy efficiency gains. With virtual fan and valve flow meter technologies, two advanced controls, including cascade control and gain scheduling control, can be implemented on both the SF and CC valve, and an advanced control using a virtual OA flow meter can be implemented on OA damper integrated with occupancy sensors. The goal of this project is to demonstrate the savings, cost, and performance of an integrated solution that integrates the three advanced HVAC controls with occupancy sensors to allow accurate and stable AHU operations in real buildings. The project objectives are to: 1) develop and validate an advance SF control algorithm; 2) develop and validate an advanced CC valve control algorithm; 3) validate an algorithm to implement a virtual OA flow meter; and 4) demonstrate the savings, cost, and performance of the integrated solution in real buildings. The technical approaches are to: 1) select a test system at the University of Oklahoma; 2) develop and implement the algorithms of advanced SF and CC valve controls and validate the performance; 3) develop and implement the advanced OA control using a virtual OA flow meter and validate the performance; 4) demonstrate the savings, cost, and performance of the proposed integrated solution with and without three advanced HVAC controls; and 5) disseminate the project results through publications and presentations. For the SF control, both the gain scheduling and cascade controls can improve the fan energy performance by reducing the fan power during the transient period and the fan control performance at lower speeds by reducing fan speed variation. Moreover, the gain scheduling control provides a simple and low-cost solution and is recommended. The fan power savings can reach 30% in a transient period. For the CC valve control, the gain scheduling control can considerably reduce the supply air temperature oscillation range and frequency under both higher and lower load conditions and the control valve response is much more stable. As a result, the gain scheduling control is recommended. The projected pump energy consumption can be reduced by 68.5%. With the developed virtual OA flow meter, the OA can be accurately controlled at its setpoint, which is determined based on the actual number of occupants in the building provided by occupancy sensors. The RMSE of the proposed OA control is 15.9 L/s. The energy data shows that the fan power and CC cooling energy were significantly reduced. On the other hand, the energy savings majorly results from the occupancy sensors and the energy savings by the advanced HVAC controls is minimal because that the controllers in the test AHU were tuned with very slow response. An annual technical savings potential is estimated as 0.5 quads in the commercial sector.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗