Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optimal Power Flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Mitigating the Impacts of Uncertain Geomagnetic Disturbances on Electric Grids: A Distributionally Robust Optimization Approach

Severe geomagnetic disturbances (GMDs) increase the magnitude of the electric field on the Earth’s surface (E-field) and drive geomagnetically-induced currents (GICs) along the transmission lines in electric grids. These additional currents can pose severe risks, such as current distortions, transformer saturation and increased reactive power losses, each of which can lead to system unreliability. Today several mitigation actions (e.g., changing grid topology) exist that can reduce the harmful GIC effects on the grids. Making such decisions can be challenging, however, because the magnitude and direction of the E-field are uncertain and non-stationary. In this paper, we model uncertain E-fields using the distributionally robust optimization (DRO) approach that determines optimal transmission grid operations such that the worst-case expectation of the system cost is minimized. We also capture the effect of GICs on the nonlinear AC power flow equations. For solution approaches, we develop an accelerated column-and-constraint generation (CCG) algorithm by exploiting a special structure of the support set of uncertain parameters representing the E-field. Extensive numerical experiments based on “epri-21” and “uiuc-150” systems, designed for GMD studies, demonstrate (i) the computational performance of the accelerated CCG algorithm, (ii) the superior performance of distributionally robust grid operations that satisfy nonlinear, nonconvex AC power flow equations and GIC constraints, in comparison with standard stochastic programming-based methods during the out-of-sample testing.

42 ENGINEERING↗

Transient Optimization of an Electrified Gas Turbine Engine Using Machine Learning

Gas turbine engines are designed with sufficient margin to prevent stall under normal operating conditions throughout their life. This compromise ensures that during rapid accelerations, compressor operation remains stable, but at the cost of efficiency and thrust responsiveness. The design margin encompasses multiple sources of uncertainty and systematic deviances from the operating line, the largest of which is the transient allowance. This set-aside accounts for the temporary incoordination of the engine spools during an acceleration while still enabling it to meet the certification requirement to accelerate from low to high power within a specified time, and without experiencing overtemperature, surge, stall, or other detrimental factors. Electrification of the powertrain provides the opportunity to address this reserve and truly optimize the design. The addition of electric machines inherent in hybrid propulsion concepts offers a means to interact with the engine shafts such that the necessary margin can be reduced, which can positively impact the engine design. By adjusting the amount of power extracted from or injected to the engine spools by the electric machines during transient operation, excursions from the operating line can be minimized. Past work using a dynamic engine model has shown that optimization of the fuel flow schedule during acceleration can reduce the required margin while still meeting the time requirement, and results are further improved when combined with power injection and extraction. The current work uses machine learning through a genetic algorithm to address the problem holistically by concurrently optimizing the electric machine power command and fuel flow acceleration schedule using an updated, higher fidelity version of the original engine model.

Stall Margin↗

Transient Optimization of an Electrified Gas Turbine Engine Using Machine Learning

Gas turbine engines are designed with sufficient margin to prevent stall under normal operating conditions throughout their life. This compromise ensures that during rapid accelerations, compressor operation remains stable, but at the cost of efficiency and thrust responsiveness. The design margin encompasses multiple sources of uncertainty and systematic deviances from the operating line, the largest of which is the transient allowance. This set-aside accounts for the temporary incoordination of the engine spools during an acceleration while still enabling it to meet the certification requirement to accelerate from low to high power within a specified time, and without experiencing overtemperature, surge, stall, or other detrimental factors. Electrification of the powertrain provides the opportunity to address this reserve and truly optimize the design. The addition of electric machines inherent in hybrid propulsion concepts offers a means to interact with the engine shafts such that the necessary margin can be reduced, which can positively impact the engine design. By adjusting the amount of power extracted from or injected to the engine spools by the electric machines during transient operation, excursions from the operating line can be minimized. Past work using a dynamic engine model has shown that optimization of the fuel flow schedule during acceleration can reduce the required margin while still meeting the time requirement, and results are further improved when combined with power injection and extraction. The current work uses machine learning through a genetic algorithm to address the problem holistically by concurrently optimizing the electric machine power command and fuel flow acceleration schedule using an updated, higher fidelity version of the original engine model.

Stall Margin↗

Transient Optimization of an Electrified Gas Turbine Engine Using Machine Learning

Gas turbine engines are designed with sufficient margin to prevent stall under normal operating conditions throughout their life. This compromise ensures that during rapid accelerations, compressor operation remains stable, but at the cost of efficiency and thrust responsiveness. The design margin encompasses multiple sources of uncertainty and systematic deviances from the operating line, the largest of which is the transient allowance. This set-aside accounts for the temporary incoordination of the engine spools during an acceleration while still enabling it to meet the certification requirement to accelerate from low to high power within a specified time, and without experiencing overtemperature, surge, stall, or other detrimental factors. Electrification of the powertrain provides the opportunity to address this reserve and truly optimize the design. The addition of electric machines inherent in hybrid propulsion concepts offers a means to interact with the engine shafts such that the necessary margin can be reduced, which can positively impact the engine design. By adjusting the amount of power extracted from or injected to the engine spools by the electric machines during transient operation, excursions from the operating line can be minimized. Past work using a dynamic engine model has shown that optimization of the fuel flow schedule during acceleration can reduce the required margin while still meeting the time requirement, and results are further improved when combined with power injection and extraction. The current work uses machine learning through a genetic algorithm to address the problem holistically by concurrently optimizing the electric machine power command and fuel flow acceleration schedule using an updated, higher fidelity version of the original engine model.

Stall Margin↗

Decentralized Voltage optimization Method for Distribution Networks with Distributed PVs

In order to solve the voltage violations caused by high penetration distributed photovoltaics (PVs), this paper proposes a decentralized voltage optimization method for distribution networks. Through the optimal dispatch of distributed PVs and reactive power resources, it realizes the voltage security and economic operation of distribution systems and facilitates the integration of massive distributed PVs. The proposed method is inspired by the idea of locational marginal price (LMP) and feasible cutting plane. It separates the optimization of boundary bus voltage and power flow in adjacent regions and uses the interaction of boundary variables’ marginal prices to obtain the optimal solution. The effectiveness and accuracy of the proposed method are demonstrated via simulation test on a practical l0kV feeder in China.

Xue, Yaosuo↗

A General Method for Estimating Zonal Transmission Interface Limits from Nodal Network Data: Preprint

Capacity expansion models for the electric power system often employ zonal (rather than nodal) resolution, necessitating estimates of aggregate power transfer limits across the interfaces between model zones. Interface limits between planning areas are sometimes published, but they are not generalizable to arbitrary zone shapes. There is thus a need for a reproducible method for estimating interface transfer limits (ITLs) between user-defined zones directly from nodal transmission system data. Here, we present a simple method for estimating ITLs using a DC power flow approximation via the power transfer distribution factor (PTDF) matrix. Linear optimization is performed to identify the distribution of power flows that maximizes the total flow on interface-crossing lines, subject to individual line ratings, limits on bus injection/withdrawal, and the relationships among flows, injections, and withdrawals imposed by the PTDF matrix. We demonstrate the application of the method on a 134-zone ~65000-bus system, and we explore the influence of flow direction, contingency level, and zone size on the estimated ITLs. There is significant heterogeneity in the ratio of the ITL to the sum of interface-crossing line ratings, which highlights the importance of accounting for the physical constraints on power flows imposed by Kirchhoff's laws when estimating zonal ITLs.

17 WIND ENERGY↗

Advanced Transmission Technologies – GETs and HPCs Session 1: ATT Foundations and Dynamic Line Ratings (DLRs)

The INL TADA GETs Cohort Session 1, held on November 4, 2025, convened experts to address the integration of advanced transmission technologies, including Grid-Enhancing Technologies (GETs) and High Performance Conductors (HPCs), with a focus on digital assurance challenges. The session highlighted the growing importance of cybersecurity, supply chain transparency, reliability, and business risk management in deploying GETs, especially Dynamic Line Ratings (DLRs). Participants examined how expanded attack surfaces, limited vendor pools, and new regulatory requirements—such as FERC Orders 881, 2023, and 1920—are influencing utilities and technology providers. The workshop underscored the need for cyber-informed engineering, secure-by-design principles, and practical risk management strategies, while fostering collaboration and knowledge sharing among industry peers. Technical discussions covered the evolution from static to dynamic line ratings, complexities of cloud-based architectures, and NERC CIP compliance challenges. The session concluded with a collaborative risk exercise and a preview of future workshops on advanced power flow control and transmission topology optimization, reinforcing the cohort’s commitment to advancing digital assurance in the energy sector.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advanced Transmission Technologies (ATTs) Supplier Cohort Workshops Cohort Summary [Slides]

This Summary slide deck summarizes the key outcomes of the Advanced Transmission Technologies (ATTs) supplier cohort, part of Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program. The program aimed to strengthen grid resilience through cybersecurity controls, supply-chain security, and Cyber-Informed Engineering (CIE) for advanced transmission technologies. The cohort brought together vendors representing the full range of Grid-Enhancing Technologies (GETs), including providers of Dynamic Line Ratings (DLR), Advanced Power Flow Control (APFC), Transmission Topology Optimization (TTO), and High-Performance Conductors (HPCs). Discussions focused on institutional, integration, and operational barriers limiting GET adoption; cybersecurity risks at EMS/SCADA, cloud, and network integration points; and supply-chain transparency issues such as semiconductor dependence and SBOM/HBOM expectations. Participants also addressed operator trust, human-in-the-loop requirements, and challenges with utility adoption, while exploring how CIE can support secure deployment of GETs. This deck represents a consolidated summary of challenges and risks identified by vendors, cross-cutting themes and technology-specific insights from three cohort workshops, and actionable mitigations to guide utilities, vendors, and the Department of Energy in advancing secure, trusted deployment of GETs.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Solving the Unit Commitment Problem: Polyhedral Theory, Symmetry, and Power Flow

In this talk, I will give an overview of mixed integer linear programming (MILP) formulations and extensions thereof which enable the effective solution of the unit commitment problem (UC) when paired with a commercial MILP solver. First, we will place UC in context, stressing the importance of achieving a (near) optimal solution. Then we will discuss the importance of perfect and "good-enough" formulations for individual generators / market participants. Some of these formulations enable symmetry-aware reformulations for identical market participants, which can be critical when symmetry is present. Finally, we will discuss approximations of AC power flow currently used in practice, and the challenges with including these approximations within the UC formulation.

MATHEMATICS AND COMPUTING↗

Power flows and Mechanical Intensities in structural finite element analysis

The identification of power flow paths in dynamically loaded structures is an important, but currently unavailable, capability for the finite element analyst. For this reason, methods for calculating power flows and mechanical intensities in finite element models are developed here. Formulations for calculating input and output powers, power flows, mechanical intensities, and power dissipations for beam, plate, and solid element types are derived. NASTRAN is used to calculate the required velocity, force, and stress results of an analysis, which a post-processor then uses to calculate power flow quantities. The SDRC I-deas Supertab module is used to view the final results. Test models include a simple truss and a beam-stiffened cantilever plate. Both test cases showed reasonable power flow fields over low to medium frequencies, with accurate power balances. Future work will include testing with more complex models, developing an interactive graphics program to view easily and efficiently the analysis results, applying shape optimization methods to the problem with power flow variables as design constraints, and adding the power flow capability to NASTRAN.

Hambric, Stephen A.↗

Scalable Unit Commitment with Security Constrained AC Power Flow via ADMM and Hybrid Modeling Strategies

This research introduces a more efficient way to optimize power grid operations, breaking the problem into manageable steps and using advanced mathematical techniques to speed up calculations. By incorporating smart heuristics, improved preprocessing, and contingency analysis, the approach allows operators to make better decisions faster. These innovations enhance our understanding of how to optimize energy generation, making it possible to anticipate failures before they happen, reduce system costs, and improve overall grid performance. Ultimately, this research helps bridge the gap between theoretical models and real-world applications, paving the way for a smarter, more resilient power grid. This research directly benefits the public by making electricity more affordable, reliable, and sustainable. By improving how power grids schedule and distribute electricity, the project helps energy providers reduce operational costs, which can lead to lower electricity prices for consumers. Additionally, the ability to predict and prevent power system failures enhances grid reliability, reducing the likelihood of blackouts that can disrupt homes, businesses, and critical infrastructure such as hospitals. From an environmental perspective, optimizing power generation reduces energy waste and lowers carbon emissions, contributing to cleaner air and a more sustainable energy system. Furthermore, with extreme weather events becoming more frequent, these advancements make the power grid more resilient, ensuring communities are better prepared for emergencies and natural disasters. By strengthening the nation's energy infrastructure, this research plays a crucial role in improving economic stability, public safety, and environmental sustainability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adjoint-Based Design of a Distributed Propulsion Concept with a Power Objective

The adjoint-based design capability in FUN3D is extended to allow efficient gradient-based optimization and design of concepts with highly integrated and distributed aero-propulsive systems. Calculations of propulsive power, along with the derivatives needed to perform adjoint-based design, have been implemented in FUN3D. The design capability is demonstrated by the shape optimization and propulsor sizing of NASA’s PEGASUS aircraft concept. The optimization objective is the minimization of flow power at the aerodynamic interface planes for the wing-mounted propulsors, as well as the tail-cone boundary layer ingestion propulsor, subject to vehicle performance and propulsive constraints.

Ordaz, Irian↗

Advanced Transmission Technologies –GETs and HPCs Session 3: HPCs and Building Actions Plans to Digital Assurance Risks

The third session of the Idaho National Laboratory’s (INL) Technical Assistance for Digital Assurance (TADA) program, held on November 11, 2025, centered on High Performance Conductors (HPCs) and the formulation of action plans to address digital assurance risks associated with Grid-Enhancing Technologies (GETs). This session convened experts from utilities, vendors, and government agencies to examine the technical, operational, and cybersecurity aspects of HPC deployment. Discussions highlighted the benefits of HPCs, such as their ability to rapidly increase transmission capacity using existing corridors, improve grid resilience, reduce system losses, and align with FERC Orders 2023 and 1920. Participants evaluated supply chain and digital assurance risks, including reliance on imported materials, limited domestic manufacturing capacity, workforce shortages, and traceability issues. The session also emphasized the importance of digital trust, integration-layer cybersecurity, and unified risk frameworks, introducing tools like intrusion detection systems, encryption, zero trust networking, and firmware integrity. Recaps of earlier workshops on Dynamic Line Ratings (DLRs), Advanced Power Flow Control (APFC), and Transmission Topology Optimization (TTO) underscored institutional barriers and integration challenges. Action plans were proposed to mitigate issues such as inconsistent cybersecurity practices, SBOM usage, supply chain visibility, operator trust, and misaligned incentives. Additionally, INL presented its supply chain risk management tools and Cyber-Informed Engineering (CIE) principles to support secure procurement and system design. The session concluded with a commitment to share key takeaways, incorporate cohort feedback into future policy development, and continue collaborative engagement through upcoming pilot activities. Session 3 of 3.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Thermal Management of Discretized Heaters Using CuW Microchannel Heat Sinks and FC3283

Single-phase cooling using microchannel heat sinks (MCHS) has become a popular approach for overcoming the thermal challenges associated with high-powered microelectronic devices. Thermal management is one of the largest barriers to higher power densities in electronics and frequently limits overall device performance. The implementation of forced convective cooling via single-phase liquid cooling in MCHS reduces the thermal resistance resulting in lower device temperatures at high-power conditions, which can decrease the package size and extend the lifespan of devices. The goal of the work described in this article was to investigate practical cooling solutions for laser diode bars. This study examined the effectiveness of a copper tungsten (CuW) microchannel heat sink paired with a dielectric coolant (FC3283) for dissipating both discrete and uniform heat fluxes up to 600 W/cm2 across a 0.25-cm2 surface area through a numerical and experimental study. CuW was chosen as the MCHS material because it is thermal expansion matched to GaAs, which is a common laser diode substrate. FC3283 serves as a dielectric coolant that is compatible with power electronics cooling. The microchannels utilized in this work were approximately $365$ $μ$ m deep and $100$ $μ$ m wide resulting in a hydraulic diameter of $160$ $μ$ m. The study investigated the cooling performance across a variety of applied power loads and flow rates to determine optimal effectiveness. The resulting thermal resistance ranged from 0.15 cm2 K/W at the highest flow rate to 0.26 cm2 K/W at the lowest flow rate. Further, the resulting thermal performance from this study demonstrates the importance of considering discrete heat sources separately from uniform heat sources and proved that the unique combination of CuW microchannels with FC3283 can be a promising cooling option toward future advancements of laser diode bars and other high-power microelectronics.

42 ENGINEERING↗

Analysis and Control of a Three-Port Converter with High-Frequency AC Link for Hybrid Unmanned/Autonomous Aerial Vehicles

In this study, a three-port resonant converter with a high-frequency isolation link for hybrid unmanned/autonomous aerial vehicle (UAV/AAV) applications is analyzed. The rectified engine-generator set output supplies the first input ports while the other is connected to a battery energy storage system. Input ports consist of half-bridge high-frequency inverters, whereas output port utilizes a semi-bridgeless active rectifier. This rectifier is formed by replacing rectifier low-side diodes with active switching devices. A phase-shift duty-cycle control is implemented for switching signals to regulate the power share and flow between ports. The proposed control system implemented achieves zero voltage switching (ZVS), reduces switching losses, and minimum current flow optimization ensures regulation in a wide range of output power. Compared to the existing bidirectional pulse width modulation (PWM) converters, the proposed system decreases the number of power conversion stages and provides centralized control without needing communications between the ports. The proposed control technique operating in closed-loop control achieves the power flow between ports under various load conditions. Finally, theoretical analysis demonstrates the proposed converter’s viability and laboratory experimental validations at 500 W full power.

33 ADVANCED PROPULSION SYSTEMS↗

Decomposable Formulation of Transmission Constraints for Decentralized Power Systems Optimization

One of the most complicating factors in decentralized solution methods for a broad range of power system optimization problems is the modeling of power flow equations. Existing formulations for direct current power flows either have limited scalability or are very dense and unstructured, making them unsuitable for large-scale decentralized studies. Here, in this work, we present a novel sparsified variant of the injection shift factors formulation, which has a decomposable block-diagonal structure and scales well for large systems. We also propose a decentralized solution method, based on the alternating direction multiplier method, that efficiently handles transmission line outages in N-1 security requirements. Benchmarks on multizonal security-constrained unit commitment problems show that the proposed formulation and algorithm can reliably and efficiently solve interconnection-level test systems with up to 6,515 buses with no convergence or numerical issues.

Alternating-method of multipliers (ADMM)↗

Resilient Operating Constraints for Power Distribution Systems under Setpoint Attacks

Integration and operation of distributed generation (DG) and energy storage (ES) in power distribution systems are enabled by communication networks and embedded sensor and control devices that increase the vulnerability of the systems to cyber-threats, broadening the attack surface and making adversary actions more unpredictable. This paper proposes a methodology that uses ellipsoidal approximations to quantify the potential damage caused by successful attacks that affect, directly or indirectly, the desired operation setpoints and may drive the power distribution operation to unsafe states by violating the limits of voltage or line flows. More specifically, a new methodology is introduced to find the optimal non-symmetric operating constraints that can be imposed to each DG and ES in order to guarantee that the power distribution system is resilient to any malicious setpoints. The proposed method takes as inputs the system topology, DG and ES capabilities, and load limits to solve a convex optimization problem formulated using linear matrix inequalities (LMIs) and the power flow equations. The proposed solution is agnostic to the attacker's action or load profile and it does not require any assumption about the location or means of the attack. The numerical results on a test distribution feeder with several DG and ES illustrate how the proposed resilient operating constraints guarantee the security of the power distribution system under setpoint attacks.

Giraldo, Jairo↗