At least 289 records · Page 16

Controlling surface adatom kinetics for improved structural and optical properties of high indium content aluminum indium nitride

A non-traditional, for AlInN, method of controlling adatom kinetics and a low temperature growth condition were employed to improve the quality of high indium content aluminum indium nitride films. Metal-rich surfaces were used to enhance adatom mobility and compensate for the low growth temperature (Tsub ≤ 400 °C) effect of reducing surface diffusion lengths. The metal-rich approach resulted in 12 times lower x-ray diffraction full-width at half-maximum rocking curve figures of merit when compared to literature. In addition to promising photoluminescence emission, these results indicate improved structural quality over other reported approaches. AlInN films with ∼70% indium content were characterized via x-ray diffraction, atomic force microscopy, and photoluminescence spectroscopy with each technique indicating an optimal growth temperature of 350 °C. Al0.3In0.7N grown above 400 °C exhibited phase separation and a reduction in quality, while samples grown colder were predominantly single-phase and displayed improved photoluminescence at ∼1.45 eV. The photoluminescence spectra suggest emission from quantum wire-like structures with dimensions ranging from 15 to 18 nm. These low-temperature, metal-rich findings for high indium content AlInN are promising for future long-wavelength III-nitride optical devices.

Engel, Zachary (ORCID:0000000205021981)↗

Poling thin-film x-cut lithium niobate for quasi-phase matching with sub-micrometer periodicity

Quasi-phase-matched grating structures in lithium niobate waveguides with sub-micrometer periodicities will benefit the development of short-wavelength nonlinear optical devices. Here, we report on the reproducible formation of periodically poled domains in x-cut single-crystalline thin-film lithium niobate with periodicities as short as 600 nm. Shaped single-voltage poling pulses were applied to electrode structures that were fabricated by a combination of electron-beam and direct-writing laser lithography. Evidence of successful poling with good quality was obtained through second-harmonic microscopy and piezoresponse force microscopy imaging. For the sub-micrometer period structures, we observed patterns with a double periodicity formed by domain interactions and features with sizes <200 nm.

Zhao, Jie (ORCID:0000000306230125)↗

Birefringence in thermally anisotropic relativistic plasmas and its impact on laser–plasma interactions

One of the paradigm-shifting phenomena triggered in laser–plasma interactions at relativistic intensities is the so-called relativistic transparency. As the electrons become heated by the laser to relativistic energies, the plasma becomes transparent to the laser light even though the plasma density is sufficiently high to reflect the laser pulse in the non-relativistic case. This paper highlights the impact that relativistic transparency can have on laser-matter interactions by focusing on a collective phenomenon that is associated with the onset of relativistic transparency: plasma birefringence in thermally anisotropic relativistic plasmas. Here, the optical properties of such a system become dependent on the polarization of light, and this can serve as the basis for plasma-based optical devices or novel diagnostic capabilities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Empowering 2D nanoelectronics via ferroelectricity

Introducing ferroelectricity to two-dimensional (2D) van der Waals (vdW) materials such as graphene, transition metal dichalcogenides, and black phosphorous presents a promising route for developing high-speed and low-power nanoelectronics. This Perspective reviews two actively pursued materials strategies, ferroelectric/vdW heterostructures and vdW ferroelectric materials. Finally, the topics discussed include their application potential and performance limitations as memory, logic, sensing, and optical devices, as well as the challenges and outlook of the field.

2D materials↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

An imaging refractometer for density fluctuation measurements in high energy density plasmas

In this work, we report on a recently developed laser-probing diagnostic which allows direct measurements of ray-deflection angles in one axis, whilst retaining imaging capabilities in the other axis. This allows us to measure the spectrum of angular deflections from a laser beam which passes though a turbulent high-energy-density plasma. This spectrum contains information about the density fluctuations within the plasma, which deflect the probing laser over a range of angles. We create synthetic diagnostics using ray-tracing to compare this new diagnostic with standard shadowgraphy and schlieren imaging approaches, which demonstrates the enhanced sensitivity of this new diagnostic over standard techniques. We present experimental data from turbulence behind a reverse shock in a plasma and demonstrate that this technique can measure angular deflections between 0.06 and 34 mrad, corresponding to a dynamic range of over 500.

47 OTHER INSTRUMENTATION↗

Designing high-power, octave spanning entangled photon sources for quantum spectroscopy

Entangled photon spectroscopy is a nascent field that has important implications for measurement and imaging across chemical, biology, and materials fields. Entangled photon spectroscopy potentially offers improved spatial and temporal-frequency resolutions, increased cross sections for multiphoton and nonlinear measurements, and new abilities in inducing or measuring quantum correlations. A critical step in enabling entangled photon spectroscopies is the creation of high-flux entangled sources that can use conventional detectors as well as provide redundancy for the losses in realistic samples. Here, we report a periodically poled, chirped, lithium tantalate platform that generates entangled photon pairs with ~10 -7 efficiency. For a near watt level diode laser, this results in a near μW-level flux. The single photon per mode limit that is necessary to maintain non-classical photon behavior is still satisfied by distributing this power over up to an octave-spanning bandwidth. The spectral–temporal photon correlations are observed via a Michelson-type interferometer that measures the broadband Hong–Ou–Mandel two-photon interference. A coherence time of 245 fs for a 10 nm bandwidth in the collinear case and a coherence time of 62 fs for a 125 nm bandwidth in the non-collinear case are measured using a CW pump laser and, essentially, collecting the full photon cone. We outline in detail the numerical methods used for designing and tailoring the entangled photons source, such as changing center wavelength or bandwidth, with the ultimate aim of increasing the availability of high-flux UV–Vis entangled photon sources in the optical spectroscopy community.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The high intensity diffractometer for residual stress analysis (HIDRA), a third generation residual stress mapping neutron diffractometer at the high flux isotope reactor

This paper describes the hardware and software upgrades, operation, and performance of the high intensity diffractometer for residual stress analysis (HIDRA) instrument, a residual stress mapping neutron diffractometer located at the High Flux Isotope Reactor at Oak Ridge National Laboratory in Oak Ridge Tennessee, USA. Following a major upgrade in 2018, the new instrument has a single 3 He multiwire 2D 30 × 30 cm 2 position sensitive detector, yielding a field of view of 17° 2θ. Further, the increase in the field of view (from 4° 2θ) from the previous model instrument has contributed to the tremendous improvement in the out of plane solid angle such that the 3D count rate could be obtained easily. Accordingly, the hardware, software, Data Acquisition System (DAS), and so on have also been updated. Finally, all these enhanced features of HIDRA have been ably demonstrated by conducting multi directional diffraction measurements in the quenched 750-T74 aluminum, and the evolved and improved strain/stress mappings are presented.

3D printing↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photo-induced electron paramagnetic resonance: A means to identify defects and the defect level throughout the bandgap of ultrawide bandgap semiconductors

Ultrawide bandgap semiconductors (UWBGs) provide great promise for optical devices operating in the near to deep ultraviolet, and recently they have become a viable semiconducting material for high power electronics. From the power grid to electronic vehicles, the intention is to replace massively awkward components with the convenience of a solid state electronic “chip.” Unfortunately, the challenges faced by wide bandgap electronic materials, such as GaN and SiC, increase as the bandgap increases. A point defect, for example, can take on more charge states and energy configurations. This perspective describes a method to investigate the many charge states and their associated transitions—photo-induced electron paramagnetic resonance (photo-EPR) spectroscopy. Although not new to the study of defects in semiconductors, photo-EPR studies can probe the entire ultrawide bandgap given the appropriate light source for excitation. Examples provided here cover specific defects in UWBGs, AlN, and Ga2O3. The discussion also reminds us how the rapid pace of discovery surrounding this newest class of semiconductors is due, in part, to fundamental research studies of the past, some as far back as a century ago and some based on very different materials systems.

Physics↗

Results from a synthetic model of the ITER XRCS-Core diagnostic based on high-fidelity x-ray ray tracing

A high-fidelity synthetic diagnostic has been developed for the ITER core x-ray crystal spectrometer diagnostic based on x-ray ray tracing. This synthetic diagnostic has been used to model expected performance of the diagnostic, to aid in diagnostic design, and to develop engineering tolerances. The synthetic model is based on x-ray ray tracing using the recently developed xicsrt ray tracing code and includes a fully three-dimensional representation of the diagnostic based on the computer aided design. The modeled components are: plasma geometry and emission profiles, highly oriented pyrolytic graphite pre-reflectors, spherically bent crystals, and pixelated x-ray detectors. Plasma emission profiles have been calculated for Xe 44+ , Xe 47+ , and Xe 51+ , based on an ITER operational scenario available through the Integrated Modelling & Analysis Suite database, and modeled within the ray tracing code as a volumetric x-ray source; the shape of the plasma source is determined by equilibrium geometry and an appropriate wavelength distribution to match the expected ion temperature profile. All individual components of the x-ray optical system have been modeled with high-fidelity producing a synthetic detector image that is expected to closely match what will be seen in the final as-built system. Particular care is taken to maintain preservation of photon statistics throughout the ray tracing allowing for quantitative estimates of diagnostic performance.

47 OTHER INSTRUMENTATION↗

Obtaining bulk-like correlated oxide surfaces with protective caps

Functional oxides exhibit a diverse range of correlated electron phenomena, some of which are highly attractive for novel electronic, magnetic, and optical devices. Despite decades of advancement of our fundamental understanding of these materials, they consistently fall short of realizing their promise in functional devices. We identify a significant bottleneck toward device realization to be surface overoxidation. Protective caps can effectively prevent overoxidation, but their interfaces with functional oxides are not well understood. These interfaces are critical for effectively using functional oxides in field-effect devices, where “the interface is the device.” This work addresses the chemistry and physics of the interface between protective caps and the correlated metal SrVO3, a model functional oxide. Our comparison of five different cap materials reveals effective protection and similar SrVO3 surface chemistry in all cases. Systematic comparisons of surface and bulk-sensitive photoelectron spectra reveal that negligible interface redox takes place, elucidating the cap-SrVO3 interface chemistry. This work demonstrates a robust and simple solution to the surface overoxidation problem in vanadates, paving the way toward effectively using these materials in field-effect devices. Our conclusions are general and can be applied to numerous other systems, thus moving oxide electronics closer to the realization of functional devices.

Cohen, Amit (ORCID:0009000276477510)↗

StarDICE III: characterization of the photometric instrument with a collimated beam projector

The measurement of Type Ia supernovae magnitudes provides cosmological distances, which constrain dark energy parameters. Current and upcoming large photometric surveys require improved photometric calibration precision to reduce systematic uncertainties in cosmological constraints. The StarDICE experiment aims to establish accurate broad-band flux references for these surveys, targeting sub-percent precision in magnitude measurements. Achieving this requires precise filter bandpass measurements for both StarDICE and survey instruments with sub-nanometre accuracy. To this end, we developed the Collimated Beam Projector (CBP), an optical device for calibrating the throughput of astronomical telescopes and their filters. The CBP uses a tunable laser source and a reversed telescope to emit a parallel monochromatic light beam, continuously monitored in flux and wavelength. The CBP output flux is measured with a large-area photodiode calibrated relative to a NIST photodiode. Using CBP measurements, we derive the StarDICE telescope throughput and filter transmissions, anchoring them to NIST’s absolute calibration. After analysing systematic uncertainties, we achieved sub-nanometre accuracy for filter central wavelengths, measured filter transmission with ~0.5 per cent precision per 1 nm bin, and detected out-of-band leakages at a relative level of 10 –4 ⁠. Furthermore, we synthesized equivalent transmission for full pupil illumination from four sampled positions in the StarDICE telescope mirror, with ~0.2 nm accuracy for central wavelengths and 7 mmag for broad-band fluxes. This demonstrates our ability to characterize telescope throughput down to the millimagnitude, paving the way for future developments, such as the Rubin-CBP for measuring the LSST at Vera Rubin Observatory, and a portable CBP version for in-situ transmission monitoring.

Calibration↗

Isolation of Single Donors in ZnO

The shallow donor in zinc oxide (ZnO) is a promising semiconductor spin qubit with optical access. Single indium donors are isolated in a commercial ZnO substrate using plasma focused ion beam (PFIB) milling. Quantum emitters are identified optically by spatial and frequency filtering. The indium donor assignment is based on the optical bound exciton transition energy and magnetic dependence. The emission stability of these single donors in terms of both intensity and frequency, alongside their transition linewidths less than twice the lifetime limit, highlight the promise of single In donors as optically accessible spin qubits. Here, the optical stability of single donors after FIB fabrication is promising for optical device integration required for scalable quantum technologies based on single donors in direct band gap semiconductors.

42 ENGINEERING↗

Gaussian approximation potential for amorphous Si : H

Hydrogenation of amorphous silicon (a–Si : H) is critical for reducing defect densities, passivating midgap states and surfaces, and improving photoconductivity in silicon-based electro-optical devices. Modeling the atomic-scale structure of this material is critical to understanding these processes, which in turn is needed to describe c–Si/a–Si : H heterojunctions that are at the heart of modern solar cells with world-record efficiency. Density functional theory (DFT) studies achieve the required high accuracy but are limited to moderate system sizes of 100 atoms or so by their high computational cost. Simulations of amorphous materials have been hindered by this high cost because large structural models are required to capture the medium-range order that is characteristic of such materials. Empirical potential models are much faster, but their accuracy is not sufficient to correctly describe the frustrated local structure. Data-driven, machine-learned interatomic potentials have broken this impasse and have been highly successful in describing a variety of amorphous materials in their elemental phase. Here, we extend the Gaussian approximation potential (GAP) for silicon by incorporating the interaction with hydrogen, thereby significantly improving the degree of realism with which amorphous silicon can be modeled. We show that our Si : H GAP enables the simulation of hydrogenated silicon with an accuracy very close to DFT but with computational expense and run times reduced by several orders of magnitude for large structures. Here, we demonstrate the capabilities of the Si : H GAP by creating models of hydrogenated liquid and amorphous silicon and showing that their energies, forces, and stresses are in excellent agreement with DFT results, and their structure as captured by bond and angle distributions are in agreement with both DFT and experiments.

36 MATERIALS SCIENCE↗

Plasmonic nanoarcs: a versatile platform with tunable localized surface plasmon resonances in octave intervals

The tunability of the longitudinal localized surface plasmon resonances (LSPRs) of metallic nanoarcs is demonstrated with key relationships identified between geometric parameters of the arcs and their resonances in the infrared. The wavelength of the LSPRs is tuned by the mid-arc length of the nanoarc. The ratio between the attenuation of the fundamental and second order LSPRs is governed by the nanoarc central angle. Beneficial for plasmonic enhancement of harmonic generation, these two resonances can be tuned independently to obtain octave intervals through the design of a non-uniform arc-width profile. Because the character of the fundamental LSPR mode in nanoarcs combines an electric and a magnetic dipole, plasmonic nanoarcs with tunable resonances can serve as versatile building blocks for chiroptical and nonlinear optical devices.

42 ENGINEERING↗

Ultra-broadband mid-infrared generation in dispersion-engineered thin-film lithium niobate

Thin-film lithium niobate (TFLN) is an emerging platform for compact, low-power nonlinear-optical devices, and has been used extensively for near-infrared frequency conversion. Recent work has extended these devices to mid-infrared wavelengths, where broadly tunable sources may be used for chemical sensing. To this end, we demonstrate efficient and broadband difference frequency generation between a fixed 1-µm pump and a tunable telecom source in uniformly-poled TFLN-on-sapphire by harnessing the dispersion-engineering available in tightly-confining waveguides. We show a simultaneous 1–2 order-of-magnitude improvement in conversion efficiency and ∼5-fold enhancement of operating bandwidth for mid-infrared generation when compared to equal-length conventional lithium niobate waveguides. We also examine the effects of mid-infrared loss from surface-adsorbed water on the performance of these devices.

47 OTHER INSTRUMENTATION↗

Wavelength-tunable infrared chiral metasurfaces with phase-change materials

Optical phase-change materials exhibit tunable permittivity and switching properties during phase transition, which offers the possibility of dynamic control of optical devices. Here, a wavelength-tunable infrared chiral metasurface integrated with phase-change material GST-225 is demonstrated with the designed unit cell of parallelogram-shaped resonator. By varying the baking time at a temperature above the phase transition temperature of GST-225, the resonance wavelength of the chiral metasurface is tuned in the wavelength range of 2.33 µm to 2.58 µm, while the circular dichroism in absorption is maintained around 0.44. The chiroptical response of the designed metasurface is revealed by analyzing the electromagnetic field and displacement current distributions under left- and right-handed circularly polarized (LCP and RCP) light illumination. Moreover, the photothermal effect is simulated to investigate the large temperature difference in the chiral metasurface under LCP and RCP illumination, which allows for the possibility of circular polarization-controlled phase transition. The presented chiral metasurfaces with phase-change materials offer the potential to facilitate promising applications in the infrared regime, such as chiral thermal switching, infrared imaging, and tunable chiral photonics.

36 MATERIALS SCIENCE↗