Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OTHER INSTRUMENTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

BeyondPlanck: I. Global Bayesian analysis of the Planck Low Frequency Instrument data

We describe the BEYONDPLANCK project in terms of our motivation, methodology, and main products, and provide a guide to a set of companion papers that describe each result in more detail. Building directly on experience from ESA’s Planck mission, we implemented a complete end-to-end Bayesian analysis framework for the Planck Low Frequency Instrument (LFI) observations. The primary product is a full joint posterior distribution P(ω | d), where ω represents the set of all free instrumental (gain, correlated noise, bandpass, etc.), astrophysical (synchrotron, free-free, thermal dust emission, etc.), and cosmological (cosmic microwave background – CMB – map, power spectrum, etc.) parameters. Some notable advantages of this approach compared to a traditional pipeline procedure are seamless end-to-end propagation of uncertainties; accurate modeling of both astrophysical and instrumental effects in the most natural basis for each uncertain quantity; optimized computational costs with little or no need for intermediate human interaction between various analysis steps; and a complete overview of the entire analysis process within one single framework. As a practical demonstration of this framework, we focus in particular on low-ℓ CMB polarization reconstruction with Planck LFI. In this process, we identify several important new effects that have not been accounted for in previous pipelines, including gain over-smoothing and time-variable and non-1/f correlated noise in the 30 and 44 GHz channels. Modeling and mitigating both previously known and newly discovered systematic effects, we find that all results are consistent with the ΛCDM model, and we constrained the reionization optical depth to τ = 0.066 ± 0.013, with a low-resolution CMB-based χ 2 probability to exceed of 32%. This uncertainty is about 30% larger than the official pipelines, arising from taking a more complete instrumental model into account. The marginal CMB solar dipole amplitude is 3362.7 ± 1.4 μK, where the error bar was derived directly from the posterior distribution without the need of any ad hoc instrumental corrections. We are currently not aware of any significant unmodeled systematic effects remaining in the Planck LFI data, and, for the first time, the 44 GHz channel is fully exploited in the current analysis. We argue that this framework can play a central role in the analysis of many current and future high-sensitivity CMB experiments, including LiteBIRD, and it will serve as the computational foundation of the emerging community-wide COSMOGLOBE effort, which aims to combine state-of-the-art radio, microwave, and submillimeter data sets into one global astrophysical model.

79 ASTRONOMY AND ASTROPHYSICS↗

Incompatibility as a Resource for Programmable Quantum Instruments

Quantum instruments represent the most general type of quantum measurement, as they incorporate processes with both classical and quantum outputs. In many scenarios, it may be desirable to have some “on-demand” device that is capable of implementing one of many possible instruments whenever the experimenter desires. We refer to such objects as programmable instrument devices (PIDs), and this paper studies PIDs from a resource-theoretic perspective. A physically important class of PIDs are those that do not require quantum memories to implement, and these are naturally “free” in this resource theory. Additionally, these free objects correspond precisely to the class of unsteerable channel assemblages in the study of channel steering. The traditional notion of measurement incompatibility emerges as a resource in this theory since any PID controlling an incompatible family of instruments requires a quantum memory to build. We identify an incompatibility preorder between PIDs based on whether one can be transformed into another using processes that do not require additional quantum memories. Necessary and sufficient conditions are derived for when such transformations are possible based on how well certain guessing games can be played using a given PID. Ultimately our results provide an operational characterization of incompatibility, and they offer semi-device-independent tests for incompatibility in the most general types of quantum instruments. Published by the American Physical Society 2024

Physics↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

Technical Challenges and Gaps in Integration of Advanced Sensors, Instrumentation, and Communication Technologies with Digital Twins for Nuclear Application

This paper explores integrating advanced sensor, instrumentation, and communication technologies with digital twin technologies for nuclear energy application. Digital twins and digital-twin-enabling technologies are expected to integrate with future nuclear reactor designs and have the potential to impact currently operating nuclear power plants. Greater digital integration, advanced instrumentation and control systems, and advanced operations and maintenance practices are all associated with digital-twin-enabling technologies. Advanced sensors, instrumentation, and communication technology are expected to comprise important elements of the infrastructure required to develop and operate a nuclear digital twin system. This paper identifies and discusses challenges and gaps in developing and implementing advanced sensors and instrumentation and communication technology to be integrated with a digital twin in current and advanced reactor applications. It is important to address some challenge and gap to enable a successful near-term deploying advanced sensors, instrumentation, and communication technologies integrated with digital twins.

Yadav, Vaibhav↗

Optical calibration of the SuperCam instrument body unit spectrometers

The SuperCam remote sensing instrument on NASA’s Perseverance rover is capable of four spectroscopic techniques, remote micro-imaging, and audio recording. These analytical techniques provide details of the chemistry and mineralogy of the rocks and soils probed in the Jezero Crater on Mars. Here we present the methods used for optical calibration of the three spectrometers covering the 243–853 nm range used by three of the four spectroscopic techniques. We derive the instrument optical response, which characterizes the instrument sensitivity to incident radiation as a function of a wavelength. The instrument optical response function derived here is an essential step in the interpretation of the spectra returned by SuperCam as it converts the observed spectra, reported by the instrument as “digital counts” from an analog to digital converter, into physical values of spectral radiance.

Legett, Carey (ORCID:0000000247412841)↗

Kilonova Detectability with Wide-Field Instruments [Slides]

A diverse set of instruments increase the chances of detecting and identifying a kilonova. Early observations increase the probability of detection. More sensitive wide-field ultraviolet instruments are needed as GW detectors reach design sensitivity. There is a dearth of wide-field infrared instruments. These results are useful for guiding kilonova searches following a GW detection and sGRD observation, proposals for time on current and upcoming instruments, and planning future wide-field instruments.

79 ASTRONOMY AND ASTROPHYSICS↗

Shielding development for the VENUS imaging instrument

VENUS is an imaging instrument that will use a broad range of neutron wavelengths, from epithermal to cold, will include enhanced contrast mechanisms, and will offer novel energy-selective imaging techniques that directly connect the structures, properties, and function of complex engineering materials and systems to reveal practical and fundamental answers about their real-world performance. The instrument is to be built at SNS beam line 10 and will face the decoupled poisoned hydrogen moderator. The driving cost for the instrument is the beam line and instrument cave shielding. Initial scoping analyses were performed to estimate thickness and composition of shielding materials for the instrument cave and beam line. In light of the upcoming Proton Power Upgrade (PPU) project, these transport analyses were performed for proton beam on target at 1.3 GeV and 2 MW.

Popova, Irina I.↗

Development of an in situ dual-channel thermal desorption gas chromatography instrument for consistent quantification of volatile, intermediate-volatility and semivolatile organic compounds

Abstract. Aerosols are a source of great uncertainty in radiative forcing predictions and have poorly understood health impacts. Most aerosol mass is formed in the atmosphere from reactive gas-phase organic precursors, forming secondary organic aerosol (SOA). Semivolatile organic compounds (SVOCs) (effective saturation concentration, C*, of 10−1–103 µg m−3) comprise a large fraction of organic aerosol, while intermediate-volatility organic compounds (IVOCs) (C* of 103–106 µg m−3) and volatile organic compounds (VOCs) (C* ≥ 106 µg m−3) are gas-phase precursors to SOA and ozone. The Comprehensive Thermal Desorption Aerosol Gas Chromatograph (cTAG) is the first single instrument simultaneously quantitative for a broad range of compound-specific VOCs, IVOCs and SVOCs. cTAG is a two-channel instrument which measures concentrations of C5–C16 alkane-equivalent-volatility VOCs and IVOCs on one channel and C14–C32 SVOCs on the other coupled to a single high-resolution time-of-flight mass spectrometer, achieving consistent quantification across 15 orders of magnitude of vapor pressure. cTAG obtains concentrations hourly and gas–particle partitioning for SVOCs every other hour, enabling observation of the evolution of these species through oxidation and partitioning into the particle phase. Online derivatization for the SVOC channel enables detection of more polar and oxidized species. In this work we present design details and data evaluating key parameters of instrument performance such as I/VOC collector design optimization, linearity and reproducibility of calibration curves obtained using a custom liquid evaporation system for I/VOCs and the effect of an ozone removal filter on instrument performance. Example timelines of precursors with secondary products are shown, and analysis of a subset of compounds detectable by cTAG demonstrates some of the analytical possibilities with this instrument.

54 ENVIRONMENTAL SCIENCES↗

Analysis of instrumentation error effects on the identification accuracy of aircraft parameters

An analytical investigation is presented of the effect of unmodeled measurement system errors on the accuracy of aircraft stability and control derivatives identified from flight test data. Such error sources include biases, scale factor errors, instrument position errors, misalignments, and instrument dynamics. Two techniques (ensemble analysis and simulated data analysis) are formulated to determine the quantitative variations to the identified parameters resulting from the unmodeled instrumentation errors. The parameter accuracy that would result from flight tests of the F-4C aircraft with typical quality instrumentation is determined using these techniques. It is shown that unmodeled instrument errors can greatly increase the uncertainty in the value of the identified parameters. General recommendations are made of procedures to be followed to insure that the measurement system associated with identifying stability and control derivatives from flight test provides sufficient accuracy.

Sorensen, J. A.↗

Earth Observatory Satellite system definition study. Report 2: Instrument constraints and interfaces

The instrument constraints and interface specifications for the Earth Observatory Satellite (EOS) are discussed. The Land Use Classification Mission using a 7 band Thematic Mapper and a 4 band High Resolution Pointable Imager is stressed. The mission and performance of the instruments were reviewed and expanded to reflect the instrument as a part of the total remote sensing system. A preliminary EOS interface handbook is provided to describe the mission and system, to specify the spacecraft interfaces to potential instrument contractors, and to describe the instrument interface data required by the system integration contractor.

Source record↗

The Shuttle Orbital Maneuvering System P-V-T Propellant Quantity Gaging Accuracy and Leak Detection Allowance for Four Instrumentation Conditions

The shuttle orbital maneuvering system (OMS) pressure-volume-temperature (P-V-T) propellant gaging module computes the quantity of usable OMS propellant remaining based on the real gas P-V-T relationship for the propellant tank pressurant, helium. The OMS P-V-T propellant quantity gaging error was determined for four sets of instrumentation configurations and accuracies with the propellant tank operating in the normal constant pressure mode and in the blowdown mode. The instrumentation inaccuracy allowance for propellant leak detection was also computed for these same four sets of instrumentation. These gaging errors and leak detection allowances are presented in tables designed to permit a direct comparison of the effectiveness of the four instrumentation sets. The results show the magnitudes of the improvements in propellant quantity gaging accuracies and propellant leak detection allowances which can be achieved by employing more accurate pressure and temperature instrumentation.

Duhon, D. D.↗

Instrument to average 100 data sets

An instrumentation system is currently under development which will measure many of the important parameters associated with the operation of an internal combustion engine. Some of these parameters include mass-fraction burn rate, ignition energy, and the indicated mean effective pressure. One of the characteristics of an internal combustion engine is the cycle-to-cycle variation of these parameters. A curve-averaging instrument has been produced which will generate the average curve, over 100 cycles, of any engine parameter. the average curve is described by 2048 discrete points which are displayed on an oscilloscope screen to facilitate recording and is available in real time. Input can be any parameter which is expressed as a + or - 10-volt signal. Operation of the curve-averaging instrument is defined between 100 and 6000 rpm. Provisions have also been made for averaging as many as four parameters simultaneously, with a subsequent decrease in resolution. This provides the means to correlate and perhaps interrelate the phenomena occurring in an internal combustion engine. This instrument has been used successfully on a 1975 Chevrolet V8 engine, and on a Continental 6-cylinder aircraft engine. While this instrument was designed for use on an internal combustion engine, with some modification it can be used to average any cyclically varying waveform.

Tuma, G. B.↗

Instrumentation systems for the National Transonic Facility

Instrumentation and measurement systems designs to achieve high Reynolds number test are discussed. The national transonic tunnel with its unique operational characterisics is a complex facility and represents a significant challenge to wind tunnel instrument designers. The instrument requirements imposed by the new testing environment, the instrument systems provided for facility calibration and operation, and the research and development activities directed at meeting overall instrument and measurement requirements are described.

Guarino, J. F.↗

Flight Instrument for Measurement of Liquid-Water Content in Clouds at Temperatures Above and Below Freezing

A principle formerly used in an instrument for cloud detection was further investigated to provide a simple and rapid means for measuring the liquid-water content of clouds at temperatures above and below freezing. The instrument consists of a small cylindrical element so operated at high surface temperatures that the impingement of cloud droplets creates a significant drop in the surface temperature. ? The instrument is sensitive to a wide range of liquid-water content and was calibrated at one set of fixed conditions against rotating multicylinder measurements. The limited conditions of the calibration Included an air temperature of 20 F, an air velocity of 175 miles per hour, and a surface temperature in clear air of 475 F. The results obtained from experiments conducted with the instrument indicate that the principle can be used for measurements in clouds at temperatures above and below freezing. Calibrations for ranges of airspeed, air temperature, and air density will be necessary to adapt the Instrument for general flight use.

Perkins, Porter J.↗

An Instrument Employing a Coronal Discharge for the Determination of Droplet-Size Distribution in Clouds

A flight instrument that uses electric means for measuring the droplet-size distribution in above-freezing clouds has been devised and given preliminary evaluation in flight. An electric charge is placed on the droplets and they are separated aerodynamically according to their mass. Because the charge placed on the droplets is a. function of the droplet size, the size spectrum can 'be determined by measurement of the charge deposited on cylinders of several different sizes placed to intercept the charged droplets. An expression for the rate of charge acquisition by a water droplet in a field of coronal discharge is derived. The results obtained in flight with an instrument based on the method described indicate that continuous records of droplet-size spectrum variations in clouds can be obtained. The experimental instrument was used to evaluate the method and was not refined to the extent necessary for obtaining conclusive meteorological data. The desirable features of an instrument based on the method described are (i) The instrument can be used in clouds with temperatures above freezing; (2) the size and the shape of the cylinders do not change during the exposure time; (3) the readings are instantaneous and continuous; (4) the available sensitivity permits the study of variations in cloud structures of less than 200 feet in extent.

Brun, Rinaldo J.↗

Stratospheric instruments and analyses

The Instruments are divided into two groups, ground based instruments and satellite-borne instruments. The ground based instruments include a Dobson ozone spectrophotometer, a filter ozonometer, and ozonesondes. The satellite-borne instruments include: a backscatter ultraviolet spectrometer, a high resolution infrared radiation sounder, a infrared interferometer spectrometer, a limb radiance inversion radiometer, and multichannel filter radiometer. A list of investigations using stratospheric satellite data is presented.

Source record↗

Advanced CO2 removal process control and monitor instrumentation development

A progam to evaluate, design and demonstrate major advances in control and monitor instrumentation was undertaken. A carbon dioxide removal process, one whose maturity level makes it a prime candidate for early flight demonstration was investigated. The instrumentation design incorporates features which are compatible with anticipated flight requirements. Current electronics technology and projected advances are included. In addition, the program established commonality of components for all advanced life support subsystems. It was concluded from the studies and design activities conducted under this program that the next generation of instrumentation will be greatly smaller than the prior one. Not only physical size but weight, power and heat rejection requirements were reduced in the range of 80 to 85% from the former level of research and development instrumentation. Using a microprocessor based computer, a standard computer bus structure and nonvolatile memory, improved fabrication techniques and aerospace packaging this instrumentation will greatly enhance overall reliability and total system availability.

Heppner, D. B.↗

Instrument scan - Is it an indicator of the pilot's workload

Results of an investigation of the relationship between an aircraft pilot's visual scanning of instruments and the level of mental activity during a simulated approach and landing are presented. Noting that periods of activity which demand either close to 100% of human capacity or low levels of capacity are the times when most errors are committed, trials were conducted with three NASA test pilots in a terminal configured vehicle simulator. The pilots flew a normal approach while verbally responding to three digit stimuli to be judged plus or minus according to an order of magnitude scheme, and also while using a control stick to extinguish a light that came on and off to the right and left of the instrument panel. Eyescans of the instrumentation were monitored, and determinations were made of the most common instruments used during approach and flare. Fixation on instruments was found to increase with the arithmetic tasks.

Ephrath, A. R.↗