Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “OPTICAL SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Photoheliograph optical system

Apollo telescope mount photoheliograph for high resolution cinematographs in white light near ultraviolet and narrow band hydrogen alpha

Becker, R. A.↗

Noise diffraction patterns eliminated in coherent optical systems

Lens rotation technique of noise diffraction pattern elimination spreads diffracted energy, normally concentrated over small area of image, over much larger annular area. Technique advantages include simplified lens selecting process, reduced clean room requirements, and low cost equipment requirements.

Grebowsky, G. R.↗

Molecular branching ratio method for intensity calibration of optical systems in the vacuum ultraviolet

A state-of-the-art review is given of the molecular branching ratio method for intensity calibration in the vacuum ultraviolet. Ways are described for determining both relative and quantitative responses in the wavelength range 1000 A to 3000 A. The molecular band systems which are discussed are the following: H2(B 1 Sigma u +)-(X 1 Sigma g +), H2(C 1 Pi u)-(X 1 Sigma g +), N2(A 1 Pi g)-(X 1 Sigma g +), CO(A 1 Pi)-(X 1 Sigma +), NO(A 2 Sigma +)-(X 2 Pi r), and NO(+) (A 1 Pi)-(X 1 Sigma +).

Mumma, M. J.↗

Frequency selective coupler for integrated optics systems.

A frequency selective coupler which consists of two thin film waveguides imbedded in a periodic medium is studied using the Brillouin diagram. Detailed results for the relative bandwidth and the coupling factor are plotted as a function of normalized frequency for a representative case.

Elachi, C.↗

Polarization - A key to an airborne optical system for the detection of oil on water.

Skylight polarization, which varies with the position of the sun in the sky, influences the contrast of oil on water. Good contrast is most consistently obtained by viewing in azimuth directions toward or away from the sun. Contrast is enhanced by imaging selected polarization components and by taking the difference between orthogonal polarization components.

Millard, J. P.↗

Strain gauge ambiguity sensor for segmented mirror active optical system

A system is described to measure alignment between interfacing edges of mirror segments positioned to form a segmented mirror surface. It serves as a gauge having a bending beam with four piezoresistive elements coupled across the interfaces of the edges of adjacent mirror segments. The bending beam has a first position corresponding to alignment of the edges of adjacent mirror segments, and it is bendable from the first position in a direction and to a degree dependent upon the relative misalignment between the edges of adjacent mirror segments to correspondingly vary the resistance of the strain guage. A source of power and an amplifier are connected in circuit with the strain gauge whereby the output of the amplifier varies according to the misalignment of the edges of adjacent mirror segments.

Wyman, C. L.↗

Correlation of an optical system degradation with contamination on a critical surface

The loss of sensitivity of a radiantly cooled radiometer during space operation was investigated. A quartz crystal microbalance (QCM), mounted in the proximity of the instrument filter lens and held at its temperature, measured the contaminant at the location during a vacuum test. The temperature cycling of the lens and the QCM verified the contamination of the lens as the cause of the deterioration. Data on the instrument performance in space and in the chamber allowed estimation of the rate of contaminant accretion on the lens in space service. That rate was used to estimate the contaminant partial pressure. The nature of material was inferred by comparison of the partial pressures and the saturated vapor pressures of materials at the temperature of the contaminated surface. These data, in conjunction with data on fields of view of the lens, are used to identify the sources of contamination.

Scialdone, J. J.↗

Heat trap - An optimized far infrared field optics system

The article deals with the design and performance of a heat trap IR system designed to maximize the concentration and efficient reception of far IR and submillimeter wavelength radiation. The test object is assumed to be extended and/or viewed at wavelengths much longer than the detector, and the entrance aperture is limited to the size of the telescope Airy diffraction disk. The design of lenses, cavity, bolometers, light collectors, and mirrors for the system is discussed. Advantages and feasibility of arrays of heat traps are considered. Beam patterns, flux concentration, and performance variation with wavelength are dealt with. The heat trap is recommended for sensing all types of far IR sources and particularly for extended far IR sources.-

Harper, D. A.↗