Alternate Reductant Cold Cap Evaluation Furnace Phase II Testing

Savannah River Remediation (SRR) conducted a Systems Engineering Evaluation (SEE) to determine the optimum alternate reductant flowsheet for the Defense Waste Processing Facility (DWPF). Specifically, two proposed flowsheets (nitric–formic–glycolic and nitric–formic–sugar) were evaluated based upon results from preliminary testing. Comparison of the two flowsheets among evaluation criteria indicated a preference towards the nitric–formic–glycolic flowsheet. Further research and development of this flowsheet eliminated the formic acid, and as a result, the nitric–glycolic flowsheet was recommended for further testing. Based on the development of a roadmap for the nitric–glycolic acid flowsheet, Waste Solidification Engineering (WS-E) issued a Technical Task Request (TTR) to address flammability issues that may impact the implementation of this flowsheet. Melter testing was requested in order to define the DWPF flammability envelope for the nitric-glycolic acid flowsheet. The Savannah River National Laboratory (SRNL) Cold Cap Evaluation Furnace (CEF), a 1/12 th scale DWPF melter, was selected by the SRR Alternate Reductant project team as the melter platform for this testing. The overall scope was divided into the following sub-tasks as discussed in the Task Technical and Quality Assurance Plan (TTQAP): Phase I - A nitric–formic acid flowsheet melter test (unbubbled) to baseline the CEF cold cap and vapor space data to the benchmark melter flammability models; Phase II - A nitric–glycolic acid flowsheet melter test (unbubbled and bubbled) to: Define new cold cap reactions and global kinetic parameters in support of the melter flammability model development; Quantify off-gas surging potential of the feed; Characterize off-gas condensate for complete organic and inorganic carbon species. After charging the CEF with cullet from Phase I CEF testing, the melter was slurry-fed with glycolic flowsheet based SB6-Frit 418 melter feed at 36% waste loading and was operated continuously for 25 days. Process data was collected throughout testing and included melter operation parameters and off-gas chemistry. In order to generate off-gas data in support of the flammability model development for the nitric-glycolic flowsheet, vapor space steady state testing in the range of ~300-750°C was conducted under the following conditions, (i) 100% (nominal and excess antifoam levels) and 125% stoichiometry feed and (ii) with and without argon bubbling. Adjustments to feed rate, heater outputs and purge air flow were necessary in order to achieve vapor space temperatures in this range. Surge testing was also completed under nominal conditions for four days with argon bubbling and one day without argon bubbling.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Models to Incorporate Reaction Mechanisms into DG-OSPREY: Fixed-Bed Simulations for Organic Iodides Capture Using Ag 0 Z

As one of the most potent radioisotopes released during spent nuclear fuel reprocessing, 129 I is strictly regulated and must be removed before discharge. Organic iodides (primarily alkyl iodides with different chain lengths, i.e., CH 3 I, C 4 H 9 I, and C 12 H 25 I) comprise ~2% of the total iodine in the reprocessing off-gases and are primarily present in vessel off-gas (VOG). Reduced silver mordenite (Ag 0 Z) is predominantly considered for the removal of radioiodine; however, its capture performance and underlying interaction processes with long-chain organic iodides are not fully understood. Two major tasks were accomplished in this study. First, to improve upon the previous experimental studies where Ag 0 Z was used to capture CH 3 I, C 4 H 9 I, and C 12 H 25 I at different concentrations, we comprehensively investigated the corresponding capture mechanisms by characterizing fully loaded Ag 0 Z samples. Second, computational codes were implemented to perform fixed-bed simulations that account for transport and reaction mechanisms. Scanning electron microscopy with energy dispersive X-ray analysis (SEM-EDX), powder X-ray diffraction (PXRD), UV-visible diffuse reflectance spectroscopy (UV-vis DRS), and thermogravimetric analysis (TGA) were conducted on Ag 0 Z samples that are saturated with I 2 , CH 3 I, C 4 H 9 I, and C 12 H 25 I), respectively. Results indicate that AgI is the predominant adsorption product regardless of the adsorbed iodine species, yet alkyl iodides with different carbon chain lengths may have different compositions of α- and γ-AgI. Synchrotron pair distribution function (PDF) measurements and TGA coupled with a Fourier transformed infrared detector (TGA FTIR) have been performed, and experimental data are currently analyzed. Results are expected to provide further insights into the adsorption mechanisms. The fixed-bed capture performance for CH 3 I was successfully simulated by solving mathematical equations that describe the underlying transport processes and adsorption reactions. The computational framework, Catalytic After Treatment System (CATS), that was originated in our research group, was used to solve the governing equations. Kinetic parameters, including the pore diffusivity and reaction rate constant were obtained by optimization techniques using data from thin-bed experiments performed at Oak Ridge National Laboratory. The performance of a deep bed predicted using the optimized parameters showed promising agreement with the experimental data.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodobutane Deep Bed Adsorption Test Report

The Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) Program Material Recovery and Waste Form Development (MRWFD) Campaign Off-gas Sigma Team has supported research and development on iodine control and iodine waste forms for the past several years. As a part of this on-going research, two deep-bed iodobutane adsorption tests have been performed with higher NO x levels. High (>1,000) iodine decontamination factors (DFs, the ratios of the inlet iodine concentrations divided by the outlet iodine concentrations, when the gas flowrate is constant) were achieved with both the silver aerogel and silver zeolite sorbents. The iodine adsorption mass transfer zone (the depth of the sorbent bed in which adsorption is occurring at any specific time) for these tests was estimated at 4 inches for both sorbents under the test conditions. Silver utilization for silver aerogel sorbent reached 41% (up to 12 g adsorbed iodine per 100 g silver aerogel sorbent), while silver utilization reached 43% (up to 6.8 g adsorbed iodine per 100 g silver zeolite sorbent). These values are generally consistent with results for prior methyl iodide adsorption tests. The results also indicate that, during iodine adsorption process, the organic iodide molecule decomposes so that the iodine can be adsorbed. Even when sorbent breakthrough is reached, the organic iodide molecule continues to decompose; and the unadsorbed iodine that passes through bed is no longer in the form of the original organic iodide; but in the form of iodine compounds that are soluble in NaOH solutions, such as HI or I 2 . This research and development has included iodine adsorption tests using a laboratory-scale test system containing segmented fixed beds of iodine adsorbents in series. Non-radioactive synthetic gas mixtures were blended from air, nitrogen, NO, NO 2 , water, and the target iodine compounds to represent dissolver off-gas (DOG) streams from used nuclear fuel aqueous reprocessing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of changes in microbial community structure during operation of an ammonia biofilter with molecular tools

Biofiltration has been used for two decades to remove odors and various volatile organic and inorganic compounds in contaminated off-gas streams. Although biofiltration is widely practiced, there have been few studies of the bacteria responsible for the removal of air contaminants in biofilters. In this study, molecular techniques were used to identify bacteria in a laboratory-scale ammonia biofilter. Both 16S rRNA and ammonia monooxygenase (amoA) genes were used to characterize the heterotrophic and ammonia-oxidizing bacteria collected from the biofilter during a 102-day experiment. The overall diversity of the heterotrophic microbial population appeared to decrease by 38% at the end of the experiment. The community structure of the heterotrophic population also shifted from predominantly members of two subdivisions of the Proteobacteria (the beta and gamma subdivisions) to members of one subdivision (the gamma subdivision). An overall decrease in the diversity of ammonia monooxygenase genes was not observed. However, a shift from groups dominated by organisms containing Nitrosomonas-like and Nitrosospira-like amoA genes to groups dominated by organisms containing only Nitrosospira-like amoA genes was observed. In addition, a new amoA gene was discovered. This new gene is the first freshwater amoA gene that is closely affiliated with Nitrosococcus oceanus and the particulate methane monooxygenase gene from the methane oxidizers belonging to the gamma subdivision of the Proteobacteria.

NASA Discipline Life Support Systems↗

A Review on Biomass Torrefaction Process and Product Properties for Energy Applications

Torrefaction of biomass can be described as a mild form of pyrolysis at temperatures typically ranging between 200 and 300 C in an inert and reduced environment. Common biomass reactions during torrefaction include devolatilization, depolymerization, and carbonization of hemicellulose, lignin and cellulose. Torrefaction process produces a brown to black solid uniform product and also condensable (water, organics, and lipids) and non condensable gases (CO2, CO, and CH4). Typically during torrefaction, 70% of the mass is retained as a solid product, containing 90% of the initial energy content, and 30% of the lost mass is converted into condensable and non-condensable products. The system's energy efficiency can be improved by reintroducing the material lost during torrefaction as a source of heat. Torrefaction of biomass improves its physical properties like grindability; particle shape, size, and distribution; pelletability; and proximate and ultimate composition like moisture, carbon and hydrogen content, and calorific value. Carbon and calorific value of torrefied biomass increases by 15-25%, and moisture content reduces to <3% (w.b.). Torrefaction reduces grinding energy by about 70%, and the ground torrefied biomass has improved sphericity, particle surface area, and particle size distribution. Pelletization of torrefied biomass at temperatures of 225 C reduces specific energy consumption by two times and increases the capacity of the mill by two times. The loss of the OH group during torrefaction makes the material hydrophobic (loses the ability to attract water molecules) and more stable against chemical oxidation and microbial degradation. These improved properties make torrefied biomass particularly suitable for cofiring in power plants and as an upgraded feedstock for gasification.

08 HYDROGEN↗

Tritium Content in and Release from Pressurized-Water-Reactor Fuel Cladding

It is expected that tritium pretreatment will be required in future reprocessing plants to prevent the release of tritium to the environment (except for long-cooled fuels; >30 yrs). To design and operate future reprocessing plants in a safe and environmentally compliant manner, the amount and form of tritium in the used nuclear fuel (UNF) must be understood and quantified. Tritium in light water reactor (LWR) fuel is dispersed between the fuel matrix and the fuel cladding, and some tritium may be in the plenum, probably as tritiated water (THO or T{sub 2}O). In a standard processing flowsheet, tritium management would be accomplished by treatment of liquid streams within the plant. Pretreating the fuel prior to dissolution to release the tritium into a single off-gas stream could simplify tritium management, so the removal of tritium in the liquid streams throughout the plant may not be required. The fraction of tritium remaining in the cladding may be reduced as a result of tritium pretreatment. Since Zircaloy'R cladding makes up roughly 25% by mass of UNF in the United States, processes are being considered to reduce the volume of reprocessing waste attributed to Zircaloy'R clad fuel by recovering the zirconium from the cladding for reuse. Treatment options for Zircaloy cladding include recycling to recover the significant value of the zirconium and eliminate costs associated with the disposal of transuranic-contaminated Zircaloy. If LWR fuel is reprocessed and the fuel is dissolved without tritium pretreatment, the tritium in the cladding will remain bound to the cladding. If tritium pretreatment is included in the flow sheet, some portion of the tritium in the cladding may be released along with the tritium from the fuel matrix. To design and operate reprocessing plants in a safe and environmentally compliant manner, the amount and form of tritium in the UNF must be understood and quantified. For Zircaloy-clad fuels from light water reactors, the tritium produced from ternary fission and other sources is expected to be divided between the fuel, where it is generated, and the cladding. It has been previously documented that a fraction of the tritium produced in uranium oxide fuel from LWRs can migrate and become trapped in the cladding. Estimates of the percentage of tritium in the cladding typically range from 0-96%. There is relatively limited data on how the tritium content of the cladding varies with burnup and fuel history (temperature, power, etc.) and how pretreatment impacts its release. The present study was undertaken to understand how tritium pretreatment at standard tritium pretreatment conditions (oxidation in air at 480 to 600 deg. C) affects the tritium content in the Zircaloy cladding and the extent to which the tritium content could be reduced with modest increases in the tritium pretreatment temperature. The data indicate that <20% of the tritium in PWR cladding will be removed by pretreatment at 500-700 deg. C for 24 h. Essentially 100% of the tritium will likely be released if the heating time at 700 deg. C is extended to 96 h. Small amounts of tritium are expected to be released if the cladding is heated at ≤ 600 deg. C for up to 96 h. The results of this study indicate that the amount of tritium released from tritium pretreatment systems will be dependent on both the operating temperature and length of time in the pretreatment system. Under certain conditions, a significant fraction of the tritium could remain bound in the cladding and would need to be considered in any subsequent processing of the cladding to recover/recycle the zirconium. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Process Considerations for the Production of Hydrogen via Steam Reforming of Oxygenated Gases from Biomass Pyrolysis and Other Conversion Processes

Abstract In 2021, average CO 2 emissions was 9.7 g CO 2 /g H 2 produced, primarily based on steam methane reforming (SMR) technology that currently dominates hydrogen production. The substitution of natural gas (NG) and other fossil feedstocks in SMRs with renewable gases may be considered as an option for reducing greenhouse gas emissions. This analysis explores process impacts and constraints associated with the potential introduction of biogenic gases into SMRs. The results indicate that replacing NG in the fuel train of the SMR, followed by partial replacement of NG in the feed train may be a feasible approach. For the CO‐ and CO 2 ‐rich gas compositions assumed in this analysis the results indicate that feed train may accommodate up to 25 mole % of biogenic gases using allowances in existing designs and/or with small modifications, while maintaining similar hydrogen output. NG substitution in higher proportions require more major changes because of increased flow rates and heat exchange requirements in the system. Biogenic gases with lower CO 2 and higher calorific values are advantageous for NG substitution, and dry reforming using the CO 2 present in the feed gas can reduce steam consumption and increase process efficiency within limits where coking does not become a new constraint.

08 HYDROGEN↗

Adsorption of iodine on hydrogen-reduced silver-exchanged mordenite: Experiments and modeling

The adsorption process of iodine, a major volatile radionuclide in the off-gas streams of spent nuclear fuel reprocessing, on hydrogen-reduced silver-exchanged mordenite (Ag 0 Z) was studied at the micro-scale. The gas-solid mass transfer and reaction involved in the adsorption process were investigated and evaluated with appropriate models. Optimal conditions for reducing the silver-exchanged mordenite (AgZ) in a hydrogen stream were determined. Kinetic and equilibrium data of iodine adsorption on Ag 0 Z were obtained by performing single-layer adsorption experiments with experimental systems of high precision at 373–473 K over various iodine concentrations. Results indicate approximately 91% to 97% of the iodine adsorption was through the silver-iodine reaction. The effect of temperature on the iodine loading capacity of Ag 0 Z was discussed. In conclusion, the Shrinking Core model describes the data well, and the primary rate controlling mechanisms were macro-pore diffusion and silver-iodine reaction. © 2016 American Institute of Chemical Engineers AIChE J, 2016

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Effectiveness of purging on preventing gas emission buildup in wood pellet storage

Storage of wood pellets has resulted in deadly accidents in connection with off-gassing and self-heating. A forced ventilation system should be in place to sweep the off-gases and control the thermal conditions. In this study, multiple purging tests were conducted in a pilot scale silo to evaluate the effectiveness of a purging system and quantify the time and volume of the gas needed to sweep the off-gases. To identify the degree of mixing, residence time distribution of the tracer gas was also studied experimentally. Large deviations from plug flow suggested strong gas mixing for all superficial velocities. As the velocity increased, the system dispersion number became smaller, which indicated less degree of mixing with increased volume of the purging gas. Finally, one-dimensional modelling and numerical simulation of the off-gas concentration profile gave the best agreement with the measured gas concentration at the bottom and middle of the silo.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lab-scaled performance evaluation of novel water-lean solvents for post combustion CO 2 capture

Here, this work focuses on demonstrating the energetic performance and operational reliability in a continuous system of RTI's water-lean solvents for post-combustion CO 2 capture applications. RTI's Non-Aqueous Solvent, NAS-1A was subjected to 100 h of continuous, CO 2 capture and regeneration operation using a Lab-scale Gas Absorption System (LsGAS) while the CO 2 capture efficiency, mass balance, and total energy inputs were monitored. Throughout the test period, NAS-1A demonstrated stable operation with 90% CO 2 capture while requiring about 15% lower total energy input for solvent regeneration compared to 30 wt% monoethanolamine (MEA) solution. The use of a slipstream of CO 2 -rich solvent from the absorber sump reduced the regenerated CO 2 temperature before the gas was further cooled by the overhead condenser at the top of the desorber. The rich-split setup combined with a wash section may be an effective approach to remove water and solvent vapor from the regenerated CO 2 as well as to recover heat at the top of the desorber. NAS-1B was later developed and included a modifier component that lowers the heat of CO 2 absorption and reduces the vapor pressure of the amine component. The total energy inputs for 90% CO 2 capture with NAS-1B was found to be 25% less than that of the MEA. A gas chromatograph was used to monitor the amine concentration in the gas leaving the absorber wash section. It was found that under similar operating conditions, the presence of the modifier in NAS-1B reduces the amine in the absorber off-gas from 143 ppm in NAS-1A to 20 ppm.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Reactor Facility Operational State Classification Using Gas Effluents and Radiation Measurements

Inferring the operational state of a reactor facility, using measurements from an independent in-situ monitoring system, is critical to the assessment of its compliance to agreements. We consider the problem of inferring the on/off operational state of a facility by using gas effluents and radiation measurements collected at the reactor's off-gas ventilation stack and within its surrounding area. Effluent release concentrations of three noble gases, namely, Ar-41, Cs-138, and Xe-138, are collected inside the ventilation stack and provided every four hours. Gamma spectra is recorded every second by a radiation detector located about 100 meters offset from the stack, which is affected by weather and nearby conditions. We study classifiers based on the correlation coefficient (CC) method [1] applied to individual modalities and their combinations. We implement CC classifiers using ground truth measurements collected over 2 operational cycles of High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) in year 2017.

Ramirez Aviles, Camila A.↗

On/Off State Classification of a Reactor Facility Using Gas Effluence Measurements

Inferring on/off operational state of a reactor facility using measurements from an independent monitoring system is critical to the assessment of its compliance to agreements. In this paper, we consider the problem of inferring on/off state of a reactor facility using measurements of Ar-41, Cs-138, and Xe-138 gas effluence types collected at the facility’s off-gas stack. We present classifiers based on thresholding measurements of individual effluence types, and then present fusers that combine their outputs or measurements. We present five fusers based on simple majority rule, Chow’s pattern recognition function, Fisher’s combined p-value statistic, physics-based Poisson radiation counts model, and correlation coefficient method. In addition, we also test five machine learning methods based on non-linear classifiers, which are available as R packages. Finally, our results show that: (i) these gas effluence measurements are effective in inferring on/off state of a reactor facility; for example, best fusers achieve ~97% detection at ~1% false alarm rate, and (ii) fusers that combine all effluence types based on physics-based models, correlation coefficient and Fisher’s method outperform simple majority rule, Chow’s fusers and machine learning methods, as well as when they are applied to individual and pairs of effluence types.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Complete Phase I Tests As Described in the Multi-lab Test Plan for the Evaluation of CH3I Adsorption on AgZ

Silver-exchanged mordenite (AgZ) has been identified as a potential sorbent for iodine present in the off-gas streams of a used nuclear fuel reprocessing facility. In such a facility, both elemental and organic forms of iodine are released from the dissolver in gaseous form. These species of iodine must be captured with high efficiency for a facility to avoid radioactive iodine release above regulatory limits in the gaseous effluent of the plant. Studies completed at Idaho National Laboratory (INL) examined the adsorption of organic iodine in the form of CH3I by AgZ. Upon breakthrough of the feed gas through the sorbent bed, elemental iodine was observed in the effluent stream, despite the fact that the only source of iodine in the system was the CH3I in the feed gas.1 This behavior does not appear to have been reported previously nor has it been independently confirmed. Thus, as a result of these prior studies, multiple knowledge gaps relating to the adsorption of CH3I by AgZ were identified, and a multi-lab test plan, including Oak Ridge National Laboratory (ORNL), INL, Pacific Northwest National Laboratory (PNNL), and Sandia National Laboratories, was formulated to address each in a systematic way.2 For this report, the scope of work for ORNL was further narrowed to three thin-bed experiments that would characterize CH3I adsorption onto AgZ in the presence of water, NO, and NO2. Completion of these three-thin bed experiments demonstrated that organic iodine in the form of CH3I was adsorbed by reduced silver mordenite (Ag0Z) to a 50% higher loading than that of I2 when adsorbed from a dry air stream. Adsorption curves suggest different adsorption mechanisms for I2 and CH3I. In the presence of NO and NO2 gas, the loading of CH3I onto Ag0Z is suppressed and may be reversible. Further, the presence of NO and NO2 gas appears to oxidize CH3I to I2; this is indicated by an adsorption curve similar to that of I2 on Ag0Z. Finally, the loss of organic iodine loading capacity by Ag0Z in the presence of NOx is unaffected by the addition of water vapor to the gas stream; no marked additional loss in capacity or retention was observed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Radioactive Semivolatiles in Nuclear Fuel Reprocessing

In nuclear fuel reprocessing, various radioactive elements enter the gas phase from the unit operations found in the reprocessing facility. In previous reports, the pathways and required removal were discussed for four radionuclides known to be volatile, 14 C, 3 H, 129 I, and 85 Kr. Other, less volatile isotopes can also report to the off-gas streams in a reprocessing facility. These were reported to be isotopes of Cs, Cd, Ru, Sb, Tc, and Te. In this report, an effort is made to determine which, if any, of 24 semivolatile radionuclides could be released from a reprocessing plant and, if so, what would be the likely quantities released. As part of this study of semivolatile elements, the amount of each generated during fission is included as part of the assessment for the need to control their emission. Also included in this study is the assessment of the cooling time (time out of reactor) before the fuel is processed. This aspect is important for the short-lived isotopes shown in the list, especially for cooling times approaching 10 y. The approach taken in this study was to determine if semivolatile radionuclides need to be included in a list of gas-phase radionuclides that might need to be removed to meet Environmental Protection Agency (EPA) and Nuclear Regulatory Commission (NRC) regulations. A list of possible elements was developed through a literature search and through knowledge and literature on the chemical processes in typical aqueous processing of nuclear fuels. A long list of possible radionuclides present in irradiated fuel was generated and then trimmed by considering isotope half-life and calculating the dose from each to a maximum exposed individual with the US EPA airborne radiological dispersion and risk assessment code CAP88 (Rosnick 1992) to yield a short list of elements that actually need to be considered for control because they require high decontamination factors to meet a reasonable fraction of the regulated release. Each of these elements is then discussed with respect to what is known in the literature about their behavior in a reprocessing facility. The context for the evaluation in this document is a UO2-based fuel processed through an aqueous-based reprocessing system with a TBP-based solvent extraction chemistry. None of these elements form sufficiently volatile compounds in the context of the reprocessing facility to be of regulatory concern.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Evaluation of Iodine and Water Co-adsorption on Silver-Functionalized Aerogel

The co-adsorption of iodine and water on silver-functionalized silica aerogel was evaluated using research quantities of the aerogel prepared at Pacific Northwest National Laboratory. A macro thermogravimetric analyzer was used to measure weight changes in a thin bed of the aerogel as air streams containing moisture and/or iodine flowed through the bed. The total gas flow in all tests was adjusted to achieve a velocity of 10 m/min through the bed. Initial heating of the aerogel sample to 150°C in dry air (dew point < -60°C) resulted in weight loss on the order of 1 wt %. Because subsequent phases of the tests indicated that the aerogel did not sorb water, the weight loss was speculated to be caused by volatilization of material that may have been used in the manufacture of the aerogel. Follow-on tests are recommended to ascertain if the aerogel sorbs water at low temperatures, such as 25°C—this would help to determine if a manufacturing reagent is volatilized when raising the sample to iodine sorption temperatures (i.e., 150°C). Alternatively, the off-gas released upon heating could be condensed and analyzed. In tests using humidified air streams with dew points between -60°C and +10°C, the aerogel did not adsorb water at test temperatures of either 75°C or 150°C. Because water alone was not adsorbed, tests were performed to ascertain if iodine sorption varied between cases when nearly no water was present in the gas stream and when water was present. In one experiment, the gas stream consisted of dry air (dew point < -60°C) with an iodine concentration of 50 ppmv. In the other experiment, the gas stream consisted of air with a water dew point of 0°C and an iodine concentration of 50 ppmv. The ultimate weight gain was nearly the same in both experiments and was presumed to be due entirely to adsorption of iodine. However, a reduced rate of iodine uptake is indicated when water vapor is present. The reason for this is unclear. In both cases, purging the sample with dry, iodine-free air resulted in some weight loss (~2 wt %). It is recommended that the gas phase chemistry of the iodine–water system be reviewed to ascertain if iodine species that are less reactive with silver than molecular iodine are present; this could explain the reduced sorption rates when water is present. Further evaluation of the desorption is recommended, especially to determine how raising the temperature would affect desorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a Zirconium Recycle Scrubber System

A hot-cell demonstration of the zirconium recycle process is planned as part of the Materials Recovery and Waste Forms Development (MRWFD) campaign. The process treats Zircaloy® cladding recovered from used nuclear fuel with chlorine gas to recover the zirconium as volatile ZrCl4. This releases radioactive tritium trapped in the alloy, converting it to volatile tritium chloride (TCl). To meet regulatory requirements governing radioactive emissions from nuclear fuel treatment operations, the capture and retention of a portion of this TCl may be required prior to discharge of the off-gas stream to the environment. In addition to demonstrating tritium removal from a synthetic zirconium recycle off-gas stream, the recovery and quantification of tritium may refine estimates of the amount of tritium present in the Zircaloy cladding of used nuclear fuel. To support these objectives, a bubbler-type scrubber was fabricated to remove the TCl from the zirconium recycle off-gas stream. The scrubber was fabricated from glass and polymer components that are resistant to chlorine and hydrochloric acid solutions. Because of concerns that the scrubber efficiency is not quantitative, tests were performed using DCl as a stand-in to experimentally measure the scrubbing efficiency of this unit. Scrubbing efficiency was ~108% ± 3% with water as the scrubber solution. Variations were noted when 1 M NaOH scrub solution was used, values ranged from 64% to 130%. The reason for the variations is not known. It is recommended that the equipment be operated with water as the scrubbing solution. Scrubbing efficiency is estimated at 100%.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Extended and Accelerated VOG Tests

The reprocessing of used nuclear fuel would release volatile radionuclides into the off-gas streams of a processing plant, including ¹²⁹I. The dissolver off-gas and more dilute vessel off-gas streams (VOG) must both be targeted when mitigating ¹²⁹I environmental release because each contains some amount of iodine. Iodine-129 will likely be found as elemental iodine (I₂) and methyl iodide (CH₃I) in these off-gas streams. Reduced silver-exchanged mordenite (AgZ or Ag⁰Z) has been investigated as a potential sorbent for iodine abatement and is studied here under prototypic VOG conditions. Because of the relatively low iodine abundance and high flow rates of the VOG, total iodine concentrations are expected to be in the parts per billion range. Thus, VOG experiments need to run for extended durations at low concentrations to reach sorbent saturation. Because the sorbent will be exposed to oxidizing gas streams for extended periods of time, aging effects and sorbent degradation need to be considered when designing a sorbent-based abatement system. Three sets of experiments were performed with the aim of determining how the adsorption of iodine by AgZ is affected by differing test durations and gas compositions. The first tested the capacity of sorbent aged for 8 months under a humid air stream. The second tested differences in sorbent capacity and mass transfer zone (MTZ) length during high-concentration (1200 ppb v ) CH₃I loading in a humid nitrogen gas (N₂) stream and a humid air gas stream over 28 days. The third tested sorbent capacity and MTZ length during low concentration (< 200 ppb v ) CH₃I and I₂ loading in a humid air stream over 9 months. The results of these tests suggest that AgZ capacity drops by ~50% after 1 month of aging, by ~60% after 2 months of aging, and then does not continue to decrease significantly at up to 8 months of aging. One-month aging tests that compared N₂ and air as the gas stream diluent resulted in similar maximum loading capacities and overall loading curves, indicating that the effects of aging cannot be mitigated by avoiding air as the balance gas. The 9-month extended VOG tests did not result in clear sorbent saturation at the inlet, but it can be inferred using an assumption of a maximum capacity of 45 mg I/g AgZ. Applying this assumption, then the MTZ of CH₃I is 12.8 cm, and the MTZ of I₂ is 12.4 cm. These results are similar to previous tests. Comparisons to tests completed at Idaho National Laboratory suggest that the CH₃I MTZ may be dependent on concentration. Future work should re-evaluate the design of the VOG iodine capture system with this updated data and should seek to understand fundamental characteristics of CH₃I adsorption by AgZ, such as the effect of concentration, gas velocity, and gas composition.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.