Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Application of the Rossi-alpha method to simulations of HEU and organic scintillators

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook contains thousands of high-quality benchmark measurements that include detailed descriptions of experiment designs and exhaustive accounting of uncertainties. These benchmarks are used extensively by the criticality safety and nuclear data communities. A subcritical benchmark involving bare, highly enriched uranium (HEU) has yet to be accepted to the handbook. The Measurement of Uranium Subcritical and Critical (MUSiC) was proposed to address this gap. MUSiC will be performed at the National Criticality Experiments Research Center (NCERC) and will leverage bare HEU hemisphere shells that can be assembled in a variety of configurations. The measurement has the following key benefits: it will be the first set of fast, subcritical measurements of HEU to be submitted to ICSBEP; ten configurations will be measured spanning from nearly no multiplication to critical (e.g., it is a measurement of similar systems with different re activities); measurements of an all-HEU system will be of value for nuclear data validation, providing results that assist in determining biases in both measurements and simulations. A variety of detector systems will be used including a Neutron Multiplicity Array Detector (NoMAD) system (similar to the MC-15), four small volume 0.635 cm (#8960;) × 7.59 cm 3He detectors (ideal for measuring prompt neutron decay constants due to their fast recovery speed), and an array of eight 5.08 cm (#8960;) × 5.08 cm EJ-309 organic scintillator detectors. The focus of this work is the simulation of the subcritical MUSiC configurations including the EJ-309 detectors and the application of the Rossi-α method. The EJ-309 organic scintillator detector array is a new detection system that will be deployed at NCERC. Organic scintillators are ideal for measurements of fast, subcritical systems due to their short time response on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total energy in supernova neutrinos and the tidal deformability and binding energy of neutron stars

The energy radiated in supernova neutrinos is a fundamental quantity that is closely related to the gravitational binding energy of a neutron star. Recently the tidal deformability of neutron stars was constrained by gravitational wave observations. By considering several equations of state, we find a strong correlation between the tidal deformability and neutron star binding energy. We use this correlation to sharpen predictions of the binding energy of neutron stars and the total neutrino energy in supernovae. We find a minimum binding energy for a neutron star formed in a supernova of ~ 1.5 × 10 53 ergs . Should the neutrino energy in a supernova be significantly below this value, it would strongly suggest new unobserved particles are carrying away some of the supernova energy. Alternatively, if the neutrino energy is observed above ~ 6 × 10 53 ergs , it would strongly imply the formation of a (perhaps surprisingly) massive neutron star.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterizing Shielded Special Nuclear Material by Neutron Capture Gamma-Ray Multiplicity Counting

We present a new neutron multiplicity counting analysis and measurement method for neutron-shielded fissile material using neutron-capture gamma rays. Neutrons absorbed in shielding produce characteristic gamma rays that preserve the otherwise lost neutron multiplicity signature. Neutron multiplicity counting provides estimates of fission parameters, such as neutron leakage multiplication, spontaneous fissioner (e.g. Pu-240) mass, and (α,n) ratio. Standard neutron multiplicity counting can incorporate the new neutron-capture gamma-ray multiplicity counting technique to characterize previously degenerate or intractable source configurations by maximizing the multiplicity signature. The new method decouples neutron source-detector interferences, such as reflection and thermalization time in the detector, that could improve measurements of the mean neutron lifetime. We also develop a detector prototype for the multiplicity counting of neutron-capture gamma rays and present detector design considerations, such as detection material and shielding, to optimize the detection of the 2.2 MeV hydrogen capture gamma ray. We simulate the prototype neutron- capture gamma-ray multiplicity counter against the BeRP ball in polyethylene shells to inform future measurements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining time-dependent ion temperature measurements in inertial confinement fusion (ICF) implosions with an intermediate distance neutron time-of-flight (nToF) detector

A concept for using an intermediate distance (0.3–3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

Moore, A. S. (ORCID:0000000221258882)↗

Excited states in semi-magic 82 Ge populated in the βn-decay of 83 Ga

For this work, the βn and β-decay of the neutron-rich 83 Ga isotopes produced in proton-induced fission of 238 U were studied at the Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory using on-line mass separation and the hybrid-3Hen neutron-γ detector array. Excited states in semi-magic 82 Ge populated in βn decay of 83 Ga were identified using neutron-γ coincidences. The measured relative population of excited states in 82 Ge is compared with a βn emission model, where the neutron emission model combines the strength distribution obtained from the shell-model calculations with the statistical Hauser-Feshbach model.

3HEN↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detector Characterization for Accurate Monte Carlo Simulation and Neutron Energy-spectrum Unfolding

This report details the characterization of a deuterated scintillation detector for use in neutron spectroscopy via the spectrum unfolding technique. The active volume of the detector consists of a 3-in. diameter by 3 in. depth right circular cylinder that contains 337 cm3 of liquid scintillator EJ-315, deuterated benzene with a D:H ratio of 141:1. A deuterated scintillator is desirable for unfolding fast neutron energy spectra because the backscattering of neutrons from deuterium produces peaks in the pulse height response corresponding to the incident neutron energy. Spectrum unfolding requires the detector’s response to be accurately known for any input neutron energy. The characterization in this report supports using a simulated response matrix calibrated by the measured light output and convolved with the measured resolution to produce a response matrix without bringing the detector to a neutron beam facility for characterization. In particular, characterization measurements were performed that included calibration of the detector’s light output to recoil electrons from gamma sources, calibration of the detector’s resolution to recoil electrons, and calibration of the detector’s light output to recoil protons from a time-tagged neutron source and a monoenergetic 14.1 MeV neutron source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Constraining the impact of chlorine as a neutron absorber in next-gen fast reactor designs

The role of chlorine as a neutron poison and as a seed for producing radioactive waste in nuclear systems has driven a renewed interest to improve its nuclear data uncertainties. Additionally, basic and applied science programs that use CLYC (Cs 2 LiYCl 6 :Ce) detectors for neutron spectroscopy and monitoring are also very sensitive to any change in chlorine nuclear data for simulations of the detector response. In this work, sensitivities relevant for these different applications are addressed through simulations of the efficiency of CLYC detectors in a fast fission spectrum when applying new chlorine nuclear data as input. These simulations are validated by an experimental measurement using CLYC detectors coupled to an ionization chamber loaded with a 252 Cf spontaneous fission source. The results are then used to obtain the first reliable direct measurement of the 35 Cl(n,p 0 ) and summed Cl(n,p+n,α) fission spectrum average cross sections, found to be 54.7(32) and 105.0(98) mb, respectively. The results are within uncertainty of calculated fission spectrum averaged cross sections based on recently re-evaluated chlorine nuclear data, which confirm recent impact studies performed for the Molten Chloride Reactor Experiment. Meanwhile, there currently exists only one published criticality benchmark experiment that is sufficiently sensitive to chlorine nuclear data. Discrepancies are found with this set of criticality safety benchmarks, which are more sensitive to thermal and epithermal neutron energies than the energies, above 100 keV, tested in this current work. Hence, there is still a need to re-evaluate the chlorine nuclear data at lower energies to assess these discrepancies. Interpretation of the data from future “faster” criticality benchmarks, which are needed for next-gen fast reactor designs, benefit from the improved constraints on the chlorine nuclear data validated in this work.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the Multi-Neutron Antineutrino Cross Section at Low Charged Hadron Energy in MINERvA

Current and future accelerator neutrino oscillation experiments need neutrino interaction models with smaller systematic uncertainties to resolve much of delta CP phase space. Final state interactions (FSI) and scattering off of correlated nuclei (2p2h) are poorly understood processes that currently contribute large uncertainties to leading models. These processes have proven difficult to study because they often produce relatively low energy nucleons. Protons up to about 100 MeV are below the detection threshold of some accelerator neutrino detectors, and neutrons are usually discounted as undetectable. This poster presents a measurement of the multi-neutron antineutrino cross section at low available energy using the MINERvA detector at Fermilab. This interaction channel is particularly sensitive to FSI and 2p2h interactions. A sideband-driven background constraint that greatly reduces uncertainties on the result will be presented. The measured cross section is compared to GENIE v3 models with different FSI treatments and the SuSA model's 2p2h predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modern Trends in Neutron Scattering Instrument Technologies

This article reviews some current trends that can be observed in the development of neutron scattering instrument technologies. While the number of neutron scattering facilities worldwide and the number of beam days they offer are largely stable, their scientific impact is increasing through improving instrumental capabilities, new and more versatile instruments, and more efficient data collection protocols. Neutron beams are becoming smaller but more intense, and instruments are being designed to utilize more ‘useful’ neutrons in unit time. This article picks and discusses a few recent developments in the areas of integrated source and instrument design, use of computational tools, new detectors, and experiment automation.

47 OTHER INSTRUMENTATION↗

Pulsed Sphere Time of Flight Neutron Spectrum Measurements: Blank Run and 1.8 Mean-Free-Path thick Polyethylene Moderating Sphere

From the late 1960s to 1985, Lawrence Livermore National Laboratory (LLNL) undertook a series of ‘pulsed sphere’ experiments for 32 materials involving 148 different experiments using 75 different spheres to measure the neutron leakage spectra for different materials from 14-MeV neutrons generated by 3 H(d, n) 4 He reactions induced by an incident D+ beam from the Insulated Core Transformer (ICT) accelerator at LLNL. This deuteron beam was focused to impinge on tritium loaded onto a titanium substrate within a low mass target assembly placed within the center of a spherical shell constructed from the material of interest. The neutron time of flight was measured at a detector outside a collimator. The program was intended to be comprehensive with numerous targets of various thicknesses spanning the periodic table from H to 239 Pu. Five different neutron detectors were utilized to avoid possible systematic errors due to differences in detector responses. Further, these measurements were designed with the aim that the simple geometry of the measurements could be easily simulated to validate Monte Carlo transport codes and nuclear data libraries. As a result, these benchmarks have been extensively used in the validation of ENDL, ENDF and other libraries. Two experiments selected as benchmark cases in this evaluation are: 1) target assembly without material sphere (blank run), and 2) target assembly with a hollow polyethylene sphere, 1.8 mean free path (mfp) or 16.56 cm thick.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Trade Study of Nondestructive Assay Technologies

The purpose of this report is to summarize the capabilities of currently existing NDA technologies that can be applied to holdup measurements. Cataloguing the strengths and weaknesses of the existing state of the art is a necessary step towards setting goals for new technology development. The NDA technologies evaluated in this report include gamma imaging, non-imaging gamma detectors, and neutron coincidence counting. These technologies were chosen based on their potential for technological improvement or to be applied in different settings. Each technology will be analyzed on a set of evaluation criteria chosen to represent the most salient features of a detector system for holdup measurements. These criteria include sensitivity, energy resolution, angular resolution (for imaging technologies only), ease of use, and cost.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Operation of the Fast Neutron Coincidence Collar (FNCL) with a DD-Neutron Generator

For more than 30 years, the quantitative assay of the 235 U content of light water reactor fresh fuel assemblies relied on measuring coincidence neutrons from fissions induced by an Am(Li) neutron source using 3 He based detectors. The Fast Neutron Collar (FNCL) developed by the International Atomic Energy Agency (IAEA), replaces traditional 3 He proportional counters with an array of liquid scintillator detectors arranged about the fuel assembly to provide improved measurement precision and reduced sensitivity to gadolinium poison rods. The FNCL relies on Am(Li) neutron sources that are no longer commercially available. This work examines the replacement of Am(Li) sources with a commercial off the-shelf deuterium–deuterium (DD) neutron generator. In addition to mitigating supply concerns, the neutron generator offers advantages in measurement precision and potential automation of sequential passive/active neutron measurements. This report presents the initial performance results for both the integrated DD/FNCL and Am(Li)/FNCL assays of compact depleted uranium, low-enriched uranium, and highly enriched uranium standards along with an estimate of the expected performance for fresh fuel assemblies. A discussion of the design and operation of the “FNCL Analysis and Simulation Software” is also provided.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nucleon Decays into Light New Particles in Neutrino Detectors

Proton and neutron decays into light new particles 𝑋 can drastically change the experimental signatures and benefit from the complementarity of large water-Cherenkov neutrino detectors such as Super- and Hyper-Kamiokande and tracking detectors such as JUNO and DUNE. The proton decays 𝑝 → ℓ + ⁢𝑋 and 𝑝 → 𝜋 + ⁢𝑋 with 𝑚 𝑋 near phase-space closure lead to charged particles below the Cherenkov threshold, rendering them practically invisible in Super- and Hyper-Kamiokande but not in JUNO and DUNE, which are therefore uniquely positioned for these baryon-number-violating signatures despite their smaller size. As an additional signature, such nucleon decays in the Earth can produce a sizable flux of 𝑋 particles in underground detectors. We present a simple model in which nucleons decay into sub-GeV sterile neutrinos that subsequently decay through active-sterile neutrino mixing, with a promisingly large number of events in Super-Kamiokande even in the seesaw-motivated parameter space.

Baryon & lepton number symmetries↗

Novel data analysis method for obtaining better performance from a complex 3D-printed collimator

Additively manufactured scattered beam collimators are increasingly being employed to boost the sample to cell peak signal ratio in high pressure neutron diffraction studies because of manufacturing versatility and performance improvements. We study how the measured diffraction pattern is affected by the presence of a collimator downstream of the sample, and develop a novel protocol that provides more effective background rejection. This protocol takes into account critical performance-determinants that were identified in this study, namely: (i) effectively identifying the collimator pattern on the detector; (ii) understanding the dependence of this pattern on sample and cell composition; and (iii) accurately identifying and differentiating the different regions of the pattern on the detector based on the dependency of the cell or sample and finally (iv) resolving the intensities at regions of the detector where neutrons scattered from the sample are preferentially represented, in order to boost the sample to cell peak signal ratio. Application of this novel analysis protocol is shown to increase the collimator performance over the traditional method.

3D printing↗