Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

284 records · Page 16

CLARREO Pathfinder Solar Diffuser Calibration Progress

Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission’s Hyperspectral Imager for Climate Science (HySICS) instrument’s transmissive flight diffuser calibration is presented. The absolute Bidirectional Transmittance Distribution Function (BTDF) measurement of the transmissive diffuser is needed to calculate the instrument’s absolute efficiency. Along with a known solar irradiance source such as Total Solar Irradiance Sensor (TSIS), it can provide an absolute irradiance measurement path on orbit, with NIST traceability. This provides an additional path for CPF to cross compare with other on orbit sensors’ measurement such as Visible-Infrared Imaging Radiometer Suite (VIIRS), Clouds and the Earth’s Radiant Energy System (CERES). The flight diffuser was calibrated at NASA’s Goddard Space Flight Center (GSFC) using the Facility’s Optical Scatterometer.

Bidirectional Transmittance Distribution Function↗

Prelaunch Spectral Characterization of the Operational Land Imager-2

The Landsat-9 satellite, launched in September 2021, carries the Operational Land Imager-2 (OLI-2) as one of its payloads. This instrument is a clone of the Landsat-8 OLI and its mission is to continue the operational land imaging of the Landsat program. The OLI-2 instrument is not significantly different from OLI though the instrument-level pre-launch spectral characterization process was much improved. The focal plane modules used on OLI-2 were manufactured as spares for OLI and much of the spectral characterization of the components was performed for OLI. However, while the spectral response of the fully assembled OLI was characterized by a double monochromator system, the OLI-2 spectral characterization made use of the Goddard Laser for Absolute Measurement of Radiance (GLAMR). GLAMR is a system of tunable lasers that cover 350–2500 nm which are fiber-coupled to a 30 in integrating sphere permanently monitored by NIST-traceable radiometers. GLAMR allowed the spectral characterization of every detector of the OLI-2 focal plane in nominal imaging conditions. The spectral performance of the OLI-2 was, in general, much better than requirements. The final relative spectral responses (RSRs) represent the best characterization any Landsat instrument spectral response. This paper will cover the results of the spectral characterization from the component-level to the instrument-level of the Landsat-9 OLI-2.

Landsat-9↗

Cryogenic Extension of NASA Species Polynomials Using Hydrogen and Oxygen at Stoichiometry

NASA has been conducting research in Rotating Detonation Rocket Engines (RDREs) for several years. A recent test at the Marshall Spaceflight Center has successfully shown operation of a RDRE that ran for 251 seconds which had combustion chamber cryogenic inlet conditions [1]. However, an overall pressure gain was not observed in the performance of the engine. Such an indication could mean an optimal chamber design is yet to be discovered. Such a design could significantly reduce parasitic pressure loses and improve overall engine efficiency beyond that of conventional rockets. To investigate different chamber configurations, new CFD capability is needed to accurately capture cryogenic thermophysical and transport property data. Such an effort is currently part of NASA’s Early Career Initiative (ECI) program. This paper focuses on the thermophysical property mixture model approach that makes use of NASA’s polynomial fits of species and another cryogenic model chosen from NIST’s Refprop program. Presented in this paper are results of a 1D denotation CFD simulation of stoichiometric Hydrogen and Oxygen mixture at a cryogenic upstream condition.

Combustion↗

Uncertainty Budget for Detector-Based Absolute Radiometric Calibration With GLAMR

The accuracy of the absolute radiometric calibration (RadCal) for remote sensing instruments is essential to their wide range of applications. The uncertainty associated to the traditional source-based RadCal method is assessed at a 2% (k=1) or higher level for radiance measurement. To further improve the accuracy to meet the demands of climate studies, a detector-based approach using tunable lasers as a light source has been devised. The Goddard Laser for Absolute Measurement of Radiance, known as the GLAMR system, is a notable example of the incorporation of such technology. Using transfer radiometers calibrated at NIST as calibration standards, the absolute spectral response (ASR) function of a remote sensing instrument is measured with its uncertainty traceable to the International System of Units. This paper presents a comprehensive uncertainty analysis of the detector-based absolute RadCal using the GLAMR system. It identifies and examines uncertainty sources during the GLAMR RadCal test, including those from the GLAMR system, the testing configuration, and data processing methodologies. Analysis is carried out to quantify the contribution of each source and emphasize the most influential factors. It is shown that the calibration uncertainty of GLAMR RadCal can be better than 0.3% (k=1) in the wavelength range of 350-950 nm and 0.6% (k=1) between 950-2300 nm, with the exception of regions with strong water absorption. In addition, recommendations are made to refine the calibration process to further reduce the uncertainty.

Zhipeng Wang↗

Parahydrogen Properties Version 05 Database Release for NTP Applications

Consistent modeling assumptions across any large project are crucial to minimize errors between different approaches. Use of consistent material and fluid properties across a large project supports consistent interpretation and application within modeling and simulation results as well as their relevancy to operational systems. NASA’s Space Nuclear Propulsion program dedicates extensive resources towards establishing consistent and, to the extent possible, accurate property databases for its internal staff and all external partners. This work highlights the extensive research performed to modernize the fluid property database of hydrogen which is the leading propellant option for in-space nuclear propelled spacecraft. Specifically, the parahydrogen spin state is of interest since the propellant is stored in a near normal boiling point liquid state which results in it consisting almost entirely of the parahydrogen spin isomer. This database tool has taken recent NASA work and modernized it into a python-based package for easy usage across all modeling entities. The package allows users to provide temperature and pressure pairs along with their desired output properties to yield results accounting for both real-gas and equilibrium dissociation effects while also sharing the default thermodynamic reference state provided by the National Institute of Standards and Technology (NIST) Standard Database 23. The suite also includes advanced capabilities to increase usability, such as on-the-fly interpolation and multidimensional plotting.

Nuclear Thermal Propulsion↗

Development Testing and Analysis of the Integrated Gateway-ESPRIT Bipropellant Refuelling System

The Gateway will be humanity’s first space station orbiting the Moon completed by NASA in partnership with ESA and other US and international partners. The Gateway will provide critical support to sustainable human exploration on the moon through the Artemis program. To enable the Lunar Gateway to complete its mission, on orbit refuelling is essential. The ESPRIT Refuelling Module (ERM) will provide the capability to transfer propellants, MMH and MON-3, through the Habitation and Logistics Outpost (HALO) to the Power and Propulsion Element (PPE). The transfer of these propellants carries known risks and hazards. These hazards include overpressure of the propellant lines during priming sequences between modules and during refuelling pause operations. To support the early system development and to mitigate these risks, a collaborative test program between NASA, ESA and Thales Alenia Space was completed at the Thales Alenia Space test facility in Harwell, UK. This test program integrated fluidic breadboards of the ERM, HALO and PPE modules. The objectives of the test program were to demonstrate and characterise critical performance and transient operations, inform refuelling concept of operations and to calibrate and validate numerical models of the refuelling subsystem in EcosimPro. To support the completion of this final objective a detailed model of the integrated breadboard was developed in EcosimPro and key steady-state and transient test cases were simulated. As an industry first, a National Institute of Standards and Technology (NIST) database correlation for Hydrofluoroether (HFE-7000) was used as a mixed oxides of nitrogen (MON-3) simulant with EcosimPro and European Space Propulsion System Simulation (ESPSS) libraries to result in a more accurate analysis for transient phenomenon such as priming. The test and simulation data showed good agreement validating the model for further system analysis as the ERM design progresses.

Refuelling↗

Cryogenic Extension of NASA Species Polynomials Using Hydrogen and Oxygen at Stoichiometry

The Helmholtz free energy for a mixture has been used in many chemistry and combustion studies for mixtures. An approach is described where polynomial fits intended for a thermally perfect ideal gases can be modified and implemented into a Helmholtz free energy model, such as those used by NIST in their REFPROP program. However, the limitation of the polynomial fits must be respected and should only used in a valid temperature interval where the flow field can be treated as a thermally perfect ideal gas when these species are present. This approach can allow a CFD simulation to have cryogenic regions of a flow field where high fidelity cryogenic species models are needed and allows for the use of species in other areas at higher temperatures where combustion species do not have such a model available or is not needed. Presented in the paper are CFD 1D detonation wave and species mass fraction simulation results which have cryogenic upstream conditions of Hydrogen and Oxygen at stoichiometry.

Combustion↗

Harnessing CPF Hyperspectral Radiances to Homogenize Earth Observing Systems

Homogenization across Earth observing systems is essential for ensuring consistency in geophysical retrievals over time and enabling the construction of long-term climate records. As the first SI Traceable Satellite (SITSat) for the reflected solar, the CLARREO Pathfinder (CPF) will provide high-accuracy spectrally resolved benchmark measurements of Earth-reflected solar radiation, serving as a standardized in-orbit reference for other reflected solar (RS) instruments. The CPF intercalibration team has developed a state-of-the-art method to intercalibrate the RS channels of the VIIRS instrument onboard the NOAA-20 satellite using CPF benchmark measurements, aiming for a methodology uncertainty of 0.3-0.6% (1-sigma). To achieve this stringent accuracy, the CPF team has devised strategies to mitigate the effects of spatial, spectral, polarization, and angular disparities between the intercalibration footprints of CPF and VIIRS. Despite nearly identical instrument designs, the three VIIRS instruments currently in operation onboard SNPP, NOAA-20, and NOAA-21 platforms exhibit systematic radiometric biases up to 8%. Although each VIIRS sensor’s calibration is independent and traceable to standards maintained by NIST, there is significant concern within the community about which VIIRS sensor most accurately represents the absolute radiometric scale. The precise intercalibration between CPF and NOAA-20 VIIRS will reveal the absolute radiometric accuracy of VIIRS. This accuracy can then be extended to other RS sensors, including MODIS and other VIIRS sensors, via vicarious methods. The 3-nm spectral sampling of CPF measurements will enable users to quantify scene-dependent spectral biases between sensors, thereby aiding in establishing both spectral and radiometric homogenization across these platforms. The CPF mission overview, along with details of its intercalibration capabilities and homogenization approaches, will be discussed at the meeting.

Raj Bhatt↗

The Genesis Non-flight Implant Sample Archive

Introduction: For the past 20 years the Genesis science community has been analyzing solar wind captured in sample collectors now curated at Johnson Space Center (JSC). Non-flown flight like collector materials (non-flight) considered reference material was always allocated by the JSC Genesis team for testing experimental procedures. However, to expedite Genesis science, distribution of non-flown reference materials were also provided by, D. S. Burnett (Genesis PI, Caltech) and A. J. G. Jurewicz (ASU) who were funded to aid all Genesis PIs by providing engineering test materials archived at Caltech pre-flight as well as ion implants into these materials [1]. Implanted materials (non-flight reference, flight-like semiconductor materials, and NIST SRM glass) received from the Caltech collection during a pilot project are being used to develop an accession procedure for the purpose of making these materials available to researchers in the future. These implant samples are important because they can be utilized as measurement standards [2]. This is a work in progress and this work reports progress in documentation and imaging. The pilot program received 63 implanted reference materials with known implanted ions. Genesis Non-Flight Database: The existing non-flight material database was modified to allow for the description of implant sessions and to allow correlation of the implant information to individual specimens. An implant session has three main components: a known ion, a known dose (ion/cm2), and a known energy (keV). Procedure: Laboratory Procedure. Upon receiving non-flight analytical standards (independently calibrated implants), or implant samples (nominally calibrated implants), they will be imaged in their current containers to capture any information written before being brought into the Genesis Sample Laboratory. Documentation is provided by the donor and used for correlating the data between the implant sessions and implant samples. This information is not verified by Genesis Curation. The microscope used to image samples in the laboratory has an automated stage with a stainless-steel plate to hold samples and a camera that utilizes the software Surveyor to take photomosaic images of the implant samples. The camera attached to the microscope is a QICAM High Performance IEEE 1394 FireWire Digital CCD Camera. This setup, shown in Fig. 1, allows for photomosaics of small-scale samples with a 10x objective or 25x objective. Examples of images taken with this microscope setup are shown in Fig.2 and Fig. 3. After imaging, samples get stored in a clean fluoroware container or polypropylene vial depending on sample size for long term storage. Database Procedure. The Genesis Non-Flight Database currently allows for the addition of implant sessions. The required fields for adding an implant session are the implant session ion, the implant session dose, and the implant session energy. There are also fields for the date and vendor of the sessions as well as a field for if the session was calibrated or not. Once an implant session has been inserted into the database, additional documentation from the session can be attached. The database will automatically assign an Implant Session Number. After inserting an implant session, the implanted samples can be inserted. The fields required for an implant sample are the material of the sample and the size of the sample. The Generic name for the implant sample with be automatically generated by the database once it has been inserted. Implant sample numbers begin with 3X to distinguish from flown Genesis sample numbers. There are also fields for processors to add the location (room, cabinet, tray) and container type (fluoroware, polypropylene vial). Once an implant session and an associated sample(s) have been inserted into the database the sample can be then tied to all associated implant sessions. An implant sample can be tied to multiple implant sessions. Future work: For curation, future work consists of creating an online catalogue for implant samples as well as updating the database with more samples as we receive them. For the scientific community these implant samples have many potential uses. For Genesis research, they are directly applicable for testing and, in some cases, as analytical standards. For non-Genesis research, implants (especially calibrated implants) could be used for calibrating other, unique planetary materials [1].

C D Calva↗

Performance of High-Resolution Mo/Cu Transition Edge Sensors Fabricated Using a Lift-Off Process

The soft X-ray band below ≈0.5 keV is expected to provide rich information on metallicity, temperature, and distribution of hot gas in our galaxy and the intergalactic medium. Resolving these densely spaced emission lines requires energy resolution on the order of 1--2 eV. The low count rates from diffuse astrophysical sources also necessitate large collection areas, particularly for a sounding rocket instrument with short exposure times and limited resources. This translates to large pixel sizes (about 1 mm 2 ) for a reasonable number of read-out channels. To achieve the required energy resolution with 200 nm thin Au absorbers (heat capacity C about 1 pJ/K), we are developing TES microcalorimeters with very high temperature sensitivity (αI), low enough current sensitivity (βI), and minimal excess noise (M). Out of the various fabrication approaches for the TES bilayer we have explored, the lift-off approach (as pioneered for Mo/Au TES by Joel Weber at NIST) so far is the simplest to execute. The simple square TES geometries we have tested to date show promising results for αI and βI. Measured complex impedance and noise for bare devices without absorbers are well described by two-body thermal models and their excess noise is found to be consistent with predictions for mixed-down Johnson noise by Wessels et al. More sensitive measurements with larger heat capacity are planned to accurately determine excess noise. In this paper, we give an overview of the process and summarize results of our detailed characterization measurements for thermal conductance G, αI, βI, and noise for several devices across a range of bias points.

Felix T Jaeckel↗

First N 2 Profile for Venus’ Deep Lower Atmosphere

We present the first N 2 profile for Venus’ deep lower atmosphere (<15 km) and a constrained isotopic composition for cloud N 2 [1]. This work directly addresses unresolved questions for Venus using legacy observations. Prior to this work, there were no reported measurements for N 2 abundances at <15 km and the isotopic composition remained unconstrained [2]. The N 2 parameters are critical to understanding the evolution and thermal properties of the atmosphere [3-7]. Our N 2 results were obtained by re-analysis of data acquired in 1978 by the Pioneer Venus Large Probe Neutral Mass Spectrometer (LNMS) [8]. The archived mass spectra from 64.2 to 0.2 km were treated using the analytical procedures specifically developed for the LNMS [9-11]. Judicious peak fitting permitted disambiguation of (A) N 2 + and CO + at 28 u and (B) 14 N 15 N+, 13 CO + , and C 2 H 5 + at 29 u. Quality controls included comparing the (A) LNMS CO + /CO 2 + ratios to the NIST database and literature and (B) fitted counts for CO + to the expected counts of CO + calculated from C 18 O + and 13 CO + using the LNMS 16 O/ 18 O and 12 C/ 13 C ratios (obtained from CO 2 ). Our results show that N 2 is uniformly mixed across the deep lower atmosphere between ~0.2 and 15 km (2.49 ± 0.10 v%). In contrast, N 2 is non-uniformly mixed across the sub-cloud atmosphere and clouds (~15–59 km), where N 2 abundances increase by ~ 2-fold between ~15 km (2.45 ± 0.32 v%) and ~59-51 km (5.21 ± 0.18 v%). Using the cloud data, we also obtained a constrained 15 N/ 14 N ratio (2.93×10 -3 ± 0.13×10 -3 ) and δ 15 N value (-204 ± 35‰). Thus, the LNMS results [1] suggest that (A) the atmosphere is unstable at <15 km, (B) N 2 is not well-mixed >15 km, and (C) the cloud δ 15 N falls between Earth and the solar wind [12, 13]. Comparisons of the N 2 abundances and isotopic compositions for nitrogen, carbon, and oxygen to other Venus measurements will be discussed.

deep lower atmosphere↗

Satellite Instrument Calibration for Measuring Global Climate Change. Report of a Workshop at the University of Maryland Inn and Conference Center, College Park, MD. , November 12-14, 2002

Measuring the small changes associated with long-term global climate change from space is a daunting task. To address these problems and recommend directions for improvements in satellite instrument calibration some 75 scientists, including researchers who develop and analyze long-term data sets from satellites, experts in the field of satellite instrument calibration, and physicists working on state of the art calibration sources and standards met November 12 - 14, 2002 and discussed the issues. The workshop defined the absolute accuracies and long-term stabilities of global climate data sets that are needed to detect expected trends, translated these data set accuracies and stabilities to required satellite instrument accuracies and stabilities, and evaluated the ability of current observing systems to meet these requirements. The workshop's recommendations include a set of basic axioms or overarching principles that must guide high quality climate observations in general, and a roadmap for improving satellite instrument characterization, calibration, inter-calibration, and associated activities to meet the challenge of measuring global climate change. It is also recommended that a follow-up workshop be conducted to discuss implementation of the roadmap developed at this workshop.

NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY (NI↗

Progress on Updating the 1961-1990 National Solar Radiation Database

The 1961-1990 National Solar Radiation Data Base (NSRDB) provides a 30-year climate summary and solar characterization of 239 locations throughout the United States. Over the past several years, the National Renewable Energy Laboratory (NREL) has received numerous inquiries from a range of constituents as to whether an update of the database to include the 1990s will be developed. However, there are formidable challenges to creating an update of the serially complete station-specific database for the 1971-2000 period. During the 1990s, the National Weather Service changed its observational procedures from a human-based to an automated system, resulting in the loss of important input variables to the model used to complete the 1961-1990 NSRDB. As a result, alternative techniques are required for an update that covers the 1990s. This paper examines several alternative approaches for creating this update and describes preliminary NREL plans for implementing the update.

Data bases↗