Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Use of 4-Dimensional Computed Tomography-Based Ventilation Imaging to Correlate Lung Dose and Function With Clinical Outcomes

Purpose: Four-dimensional computed tomography (4DCT)-based ventilation is an emerging imaging modality that can be used in the thoracic treatment planning process. The clinical benefit of using ventilation images in radiation treatment plans remains to be tested. The purpose of the current work was to test the potential benefit of using ventilation in treatment planning by evaluating whether dose to highly ventilated regions of the lung resulted in increased incidence of clinical toxicity. Methods and Materials: Pretreatment 4DCT data were used to compute pretreatment ventilation images for 96 lung cancer patients. Ventilation images were calculated using 4DCT data, deformable image registration, and a density-change based algorithm. Dose–volume and ventilation-based dose function metrics were computed for each patient. The ability of the dose–volume and ventilation-based dose–function metrics to predict for severe (grade 3+) radiation pneumonitis was assessed using logistic regression analysis, area under the curve (AUC) metrics, and bootstrap methods. Results: A specific patient example is presented that demonstrates how incorporating ventilation-based functional information can help separate patients with and without toxicity. The logistic regression significance values were all lower for the dose–function metrics (range P=.093-.250) than for their dose–volume equivalents (range, P=.331-.580). The AUC values were all greater for the dose–function metrics (range, 0.569-0.620) than for their dose–volume equivalents (range, 0.500-0.544). Bootstrap results revealed an improvement in model fit using dose–function metrics compared to dose–volume metrics that approached significance (range, P=.118-.155). Conclusions: To our knowledge, this is the first study that attempts to correlate lung dose and 4DCT ventilation-based function to thoracic toxicity after radiation therapy. Although the results were not significant at the .05 level, our data suggests that incorporating ventilation-based functional imaging can improve prediction for radiation pneumonitis. We present an important first step toward validating the use of 4DCT-based ventilation imaging in thoracic treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Geometric validation of self-gating k-space-sorted 4D-MRI vs 4D-CT using a respiratory motion phantom

Purpose: MRI is increasingly being used for radiotherapy planning, simulation, and in-treatment-room motion monitoring. To provide more detailed temporal and spatial MR data for these tasks, we have recently developed a novel self-gated (SG) MRI technique with advantage of k-space phase sorting, high isotropic spatial resolution, and high temporal resolution. The current work describes the validation of this 4D-MRI technique using a MRI- and CT-compatible respiratory motion phantom and comparison to 4D-CT. Methods: The 4D-MRI sequence is based on a spoiled gradient echo-based 3D projection reconstruction sequence with self-gating for 4D-MRI at 3 T. Respiratory phase is resolved by using SG k-space lines as the motion surrogate. 4D-MRI images are reconstructed into ten temporal bins with spatial resolution 1.56 × 1.56 × 1.56 mm{sup 3}. A MRI-CT compatible phantom was designed to validate the performance of the 4D-MRI sequence and 4D-CT imaging. A spherical target (diameter 23 mm, volume 6.37 ml) filled with high-concentration gadolinium (Gd) gel is embedded into a plastic box (35 × 40 × 63 mm{sup 3}) and stabilized with low-concentration Gd gel. The phantom, driven by an air pump, is able to produce human-type breathing patterns between 4 and 30 respiratory cycles/min. 4D-CT of the phantom has been acquired in cine mode, and reconstructed into ten phases with slice thickness 1.25 mm. The 4D images sets were imported into a treatment planning software for target contouring. The geometrical accuracy of the 4D MRI and CT images has been quantified using target volume, flattening, and eccentricity. The target motion was measured by tracking the centroids of the spheres in each individual phase. Motion ground-truth was obtained from input signals and real-time video recordings. Results: The dynamic phantom has been operated in four respiratory rate (RR) settings, 6, 10, 15, and 20/min, and was scanned with 4D-MRI and 4D-CT. 4D-CT images have target-stretching, partial-missing, and other motion artifacts in various phases, whereas the 4D-MRI images are visually free of those artifacts. Volume percentage difference for the 6.37 ml target ranged from 5.3% ± 4.3% to 10.3% ± 5.9% for 4D-CT, and 1.47 ± 0.52 to 2.12 ± 1.60 for 4D-MRI. With an increase of respiratory rate, the target volumetric and geometric deviations increase for 4D-CT images while remaining stable for the 4D-MRI images. Target motion amplitude errors at different RRs were measured with a range of 0.66–1.25 mm for 4D-CT and 0.2–0.42 mm for 4D-MRI. The results of Mann–Whitney tests indicated that 4D-MRI significantly outperforms 4D-CT in phase-based target volumetric (p = 0.027) and geometric (p < 0.001) measures. Both modalities achieve equivalent accuracy in measuring motion amplitude (p = 0.828). Conclusions: The k-space self-gated 4D-MRI technique provides a robust method for accurately imaging phase-based target motion and geometry. Compared to 4D-CT, the current 4D-MRI technique demonstrates superior spatiotemporal resolution, and robust resistance to motion artifacts caused by fast target motion and irregular breathing patterns. The technique can be used extensively in abdominal targeting, motion gating, and toward implementing MRI-based adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

WE-E-12A-01: Medical Physics 1.0 to 2.0: MRI, Displays, Informatics

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidence-based medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. MRI 2.0: This presentation will look into the future of clinical MR imaging and what the clinical medical physicist will need to be doing as the technology of MR imaging evolves. Many of the measurement techniques used today will need to be expanded to address the advent of higher field imaging systems and dedicated imagers for specialty applications. Included will be the need to address quality assurance and testing metrics for multi-channel MR imagers and hybrid devices such as MR/PET systems. New pulse sequences and acquisition methods, increasing use of MR spectroscopy, and real-time guidance procedures will place the burden on the medical physicist to define and use new tools to properly evaluate these systems, but the clinical applications must be understood so that these tools are use correctly. Finally, new rules, clinical requirements, and regulations will mean that the medical physicist must actively work to keep her/his sites compliant and must work closely with physicians to ensure best performance of these systems. Informatics Display 1.0 to 2.0: Medical displays are an integral part of medical imaging operation. The DICOM and AAPM (TG18) efforts have led to clear definitions of performance requirements of monochrome medical displays that can be followed by medical physicists to ensure proper performance. However, effective implementation of that oversight has been challenging due to the number and extend of medical displays in use at a facility. The advent of color display and mobile displays has added additional challenges to the task of the medical physicist. This informatics display lecture first addresses the current display guidelines (the 1.0 paradigm) and further outlines the initiatives and prospects for color and mobile displays (the 2.0 paradigm). Informatics Management 1.0 to 2.0: Imaging informatics is part of every radiology practice today. Imaging informatics covers everything from the ordering of a study, through the data acquisition and processing, display and archiving, reporting of findings and the billing for the services performed. The standardization of the processes used to manage the information and methodologies to integrate these standards is being developed and advanced continuously. These developments are done in an open forum and imaging organizations and professionals all have a part in the process. In the Informatics Management presentation, the flow of information and the integration of the standards used in the processes will be reviewed. The role of radiologists and physicists in the process will be discussed. Current methods (the 1.0 paradigm) and evolving methods (the 2.0 paradigm) for validation of informatics systems function will also be discussed. Learning Objectives: Identify requirements for improving quality assurance and compliance tools for advanced and hybrid MRI systems. Identify the need for new quality assurance metrics and testing procedures for advanced systems. Identify new hardware systems and new procedures needed to evaluate MRI systems. Understand the components of current medical physics expectation for medical displays. Understand the role and prospect fo medical physics for color and mobile display devices. Understand different areas of imaging informatics and the methodology for developing informatics standards. Understand the current status of informatics standards and the role of physicists and radiologists in the process, and the current technology for validating the function of these systems.

07 ISOTOPE AND RADIATION SOURCES↗

Microscopy modality transfer of steel microstructures: Inferring scanning electron micrographs from optical microscopy using generative AI

Scanning electron microscopy (SEM) is resource intensive, which limits its throughput in some applications. As an alternative, we propose applying computer vision and machine learning to generate high-quality synthetic SEM micrographs from micrographs obtained using light optical microscopy (LOM). Working with a correlated LOM/SEM dataset of dual-phase steel images, we test generative models of various architectures, including encoder-decoder networks, generative adversarial networks (GANs), and diffusion-based models. We find that the diffusion models significantly outperform other methods on both qualitative and quantitative assessments, while preserving key metallurgical meaning. This work establishes diffusion as the state-of-the-art for microscopy modality transfer and demonstrates the potential of AI-powered microscopy to enhance LOM with micron scale structural recreation.

Computer vision↗

Multi-Modal Characterization of Nuclear Fuels and Materials at the Idaho National Laboratory Materials & Fuels Complex

The Idaho National Laboratory (INL) leads cutting-edge research pertaining to the advancement of nuclear reactor technologies, including nuclear fuels and materials. The INL Irradiated Materials Characterization Laboratory (IMCL), Electron Microscopy Laboratory (EML), and future Sample Preparation Laboratory (SPL) are available to the nuclear research community to assess the behavior of nuclear fuels and materials, efficiently and comprehensively characterizing from the engineering to atomistic scale. The IMCL is a unique, 12,000-square-foot facility located at the INL Materials and Fuels Complex designed for analysis of irradiated materials. The facility operates advanced characterization instruments that are sensitive to vibration, temperature, and electromagnetic interference in modular radiological shielding and confinement systems, granting researchers the ability to assess the microstructural, chemical, mechanical and thermophysical properties of nuclear materials, especially irradiated fuels. The EML is dedicated to advanced characterization of materials with optical and electron microscopy tools, including scanning electron microscopy/focused-ion beam (SEM/FIB) and transmission electron microscopy (TEM). Upon construction, the SPL will be a 3 story, 49,000 sq. ft facility, that is the most modern reactor structural materials testing and analysis facility in the world, designed to investigate reactor structural materials in support of life-extension programs and development of advanced reactor concepts, including mechanical testing and advanced characterization capabilities. This presentation will showcase some of the main capabilities available at both IMCL, EML, and SPL, specifically illustrating how these characterization techniques are incorporated into multi-modal characterization work scopes to elucidate the degradation of nuclear structural materials and irradiated fuels.

36 MATERIALS SCIENCE↗

Proton Radiotherapy for Pediatric Bladder/Prostate Rhabdomyosarcoma: Clinical Outcomes and Dosimetry Compared to Intensity-Modulated Radiation Therapy

Purpose: In this study, we report the clinical outcomes of 7 children with bladder/prostate rhabdomyosarcoma (RMS) treated with proton radiation and compare proton treatment plans with matched intensity-modulated radiation therapy (IMRT) plans, with an emphasis on dose savings to reproductive and skeletal structures. Methods and Materials: Follow-up consisted of scheduled clinic appointments at our institution or direct communication with the treating physicians for referred patients. Each proton radiotherapy plan used for treatment was directly compared to an IMRT plan generated for the study. Clinical target volumes and normal tissue volumes were held constant to facilitate dosimetric comparisons. Each plan was optimized for target coverage and normal tissue sparing. Results: Seven male patients were treated with proton radiotherapy for bladder/prostate RMS at the Massachusetts General Hospital between 2002 and 2008. Median age at treatment was 30 months (11-70 months). Median follow-up was 27 months (10-90 months). Four patients underwent a gross total resection prior to radiation, and all patients received concurrent chemotherapy. Radiation doses ranged from 36 cobalt Gray equivalent (CGE) to 50.4 CGE. Five of 7 patients were without evidence of disease and with intact bladders at study completion. Target volume dosimetry was equivalent between the two modalities for all 7 patients. Proton radiotherapy led to a significant decrease in mean organ dose to the bladder (25.1 CGE vs. 33.2 Gy; p = 0.03), testes (0.0 CGE vs. 0.6 Gy; p = 0.016), femoral heads (1.6 CGE vs. 10.6 Gy; p = 0.016), growth plates (21.7 CGE vs. 32.4 Gy; p = 0.016), and pelvic bones (8.8 CGE vs. 13.5 Gy; p = 0.016) compared to IMRT. Conclusions: This study provides evidence of significant dose savings to normal structures with proton radiotherapy compared to IMRT and is well tolerated in this patient population. The long-term impact of these reduced doses can be tested in future studies incorporating extended follow-up, objective outcome measures, and quality-of-life analyses.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Edge AI-Enhanced Traffic Monitoring and Anomaly Detection Using Multimodal Large Language Models

This paper addresses the challenge of traffic monitoring and incident detection in remote areas, utilizing multimodal large language models (LLMs) deployed on edge AI devices. The key novelty of the LLM is to convert real-time video streams into descriptive texts, enabling low-bandwidth transmissions and reliable detection of anomalies and incidents in environments of intermittent connectivity. The model is developed based on fine-tuning open-source LLMs and extending it with multi-modal capabilities to analyze video frames. Our work also involves deploying this model on edge devices such as Nvidia IGX Orin and is planned to be tested in realistic environments in future work. The methodology includes data set curation, iterative model fine-tuning and compression, and hardware-based optimization. This approach aims to enhance traffic safety and response speed in remote areas, marking a significant advancement in the application of AI for traffic monitoring and safety management.

Peruski, Ryan [University of Tennessee, Knoxville ↗

Development of Tools for High Volume, High Speed Non-Destructive Inspection of Carbon Fiber Reinforced Plastics (Final Technical Report)

Current composite inspection technologies are tailored towards low-volume, high value parts. The needs and priorities for high-volume mainstream automotive production are very different from those of aerospace or similar sectors that have adopted advanced composite materials at scale. Beyond efficacy, the priority for inspection in the automotive sector is a short cycle time, which does not inhibit the rate of production. The target cycle time per part is 3 minutes, with a stretch goal of 1 minute. This report details the evaluation approach, the technologies of interest, and the performance of a number of inspection technologies applied to automotive carbon fiber composites.

, modal impact↗

Model-Agnostic Algorithm for Real-Time Attack Identification in Power Grid using Koopman Modes

Malicious activities on measurements from sensors like Phasor Measurement Units (PMUs) can mislead the control center operator into taking wrong control actions resulting in disruption of operation, financial losses, and equipment damage. In particular, false data attacks initiated during power systems transients caused due to abrupt changes in load and generation can fool the conventional model-based detection methods relying on thresholds comparison to trigger an anomaly. In this paper, we propose a Koopman mode decomposition (KMD) based algorithm to detect and identify false data attacks in real-time. The Koopman modes (KMs) are capable of capturing the nonlinear modes of oscillation in the transient dynamics of the power networks and reveal the spatial embedding of both natural and anomalous modes of oscillations in the sensor measurements. The Koopman-based spatio-temporal nonlinear modal analysis is used to filter out the false data injected by an attacker. The performance of the algorithm is illustrated on the IEEE 68-bus test system using synthetic attack scenarios generated on GridSTAGE, a recently developed multivariate spatio-temporal data generation framework for simulation of adversarial scenarios in cyber-physical power systems.

Nandanoori, Sai Pushpak↗

Characterization of the homogeneous tissue mixture approximation in breast imaging dosimetry

Purpose: To compare the estimate of normalized glandular dose in mammography and breast CT imaging obtained using the actual glandular tissue distribution in the breast to that obtained using the homogeneous tissue mixture approximation. Methods: Twenty volumetric images of patient breasts were acquired with a dedicated breast CT prototype system and the voxels in the breast CT images were automatically classified into skin, adipose, and glandular tissue. The breasts in the classified images underwent simulated mechanical compression to mimic the conditions present during mammographic acquisition. The compressed thickness for each breast was set to that achieved during each patient's last screening cranio-caudal (CC) acquisition. The volumetric glandular density of each breast was computed using both the compressed and uncompressed classified images, and additional images were created in which all voxels representing adipose and glandular tissue were replaced by a homogeneous mixture of these two tissues in a proportion corresponding to each breast's volumetric glandular density. All four breast images (compressed and uncompressed; heterogeneous and homogeneous tissue) were input into Monte Carlo simulations to estimate the normalized glandular dose during mammography (compressed breasts) and dedicated breast CT (uncompressed breasts). For the mammography simulations the x-ray spectra used was that used during each patient's last screening CC acquisition. For the breast CT simulations, two x-ray spectra were used, corresponding to the x-ray spectra with the lowest and highest energies currently being used in dedicated breast CT prototype systems under clinical investigation. The resulting normalized glandular dose for the heterogeneous and homogeneous versions of each breast for each modality was compared. Results: For mammography, the normalized glandular dose based on the homogeneous tissue approximation was, on average, 27% higher than that estimated using the true heterogeneous glandular tissue distribution (Wilcoxon Signed Rank Test p= 0.00046). For dedicated breast CT, the overestimation of normalized glandular dose was, on average, 8% (49 kVp spectrum, p= 0.00045) and 4% (80 kVp spectrum, p= 0.000089). Only two cases in mammography and two cases in dedicated breast CT with a tube voltage of 49 kVp resulted in lower dose estimates for the homogeneous tissue approximation compared to the heterogeneous tissue distribution. Conclusions: The normalized glandular dose based on the homogeneous tissue mixture approximation results in a significant overestimation of dose to the imaged breast. This overestimation impacts the use of dose estimates in absolute terms, such as for risk estimates, and may impact some comparative studies, such as when modalities or techniques with different x-ray energies are used. The error introduced by the homogeneous tissue mixture approximation in higher energy x-ray modalities, such as dedicated breast CT, although statistically significant, may not be of clinical concern. Further work is required to better characterize this overestimation and potentially develop new metrics or correction factors to better estimate the true glandular dose to breasts undergoing imaging with ionizing radiation.

60 APPLIED LIFE SCIENCES↗

NXIS - Well integrity inspection in unconventional gas wells

The objective of this project is to advance the state-of-the-art and to develop an integrity inspection system capable of detecting physical flaws in the wellbore structure of conventional and unconventional hydrocarbon producing wells. Measuring the integrity of multiple wellbore casings and cement annuli for onshore and offshore wells remains a challenging task. We propose a multi-modality inspection system composed of neutron and X(gamma)-ray imaging modalities (nXis) to address the above challenge. The functional principle of this wellbore integrity inspection system is the combination of high-energy modalities, such as X(gamma)-ray and neutron backscatter imaging, with conventional low-energy modalities, such as electromagnetic or ultrasound imaging techniques. By combining multiple sensing modalities into one sensing system and by fusing data between modalities, one can gather more information about the integrity of the wellbore structure compared to simply using multiple sensors individually. Imaging prototypes for gamma, neutron, and electromagnetics were designed, manufactured, and tested at GE Global Research and Starfire Industries. Wellbore phantoms with engineered defects were manufactured and the performance of the developed wellbore integrity inspection tool prototypes was evaluated in a test pit test at an industrial GE Oil & Gas facility. Data analysis and fusion between various inspection techniques show enhanced defect detectability. These exciting results were presented at various technical conferences and discussed with operators in the oil & gas industry. Great interest from oil operators lead to discussions about joint industrial partnerships to move the developed technology from the prototype phase to the product phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Quantify Resonance Inspection with Finite Element-Based Modal Analyses

Resonance inspection uses the natural acoustic resonances of a part to identify anomalous parts. Modern instrumentation can measure the many resonant frequencies rapidly and accurately. Sophisticated sorting algorithms trained on sets of good and anomalous parts can rapidly and reliably inspect and sort parts. This paper aims at using finite-element-based modal analysis to put resonance inspection on a more quantitative basis. A production-level automotive steering knuckle is used as the example part for our study. First, the resonance frequency spectra for the knuckle are measured with two different experimental techniques. Next, scanning laser vibrometry is used to determine the mode shape corresponding to each resonance. The material properties including anisotropy are next measured to high accuracy using resonance spectroscopy on cuboids cut from the part. Then, finite element model (FEM) of the knuckle is generated by meshing the actual part geometry obtained with computed tomography (CT). The resonance frequencies and mode shapes are next predicted with a natural frequency extraction analysis after extensive mesh size sensitivity study. The good comparison between the predicted and the experimentally measured resonance spectra indicate that finite-element-based modal analyses have the potential to be a powerful tool in shortening the training process and improving the accuracy of the resonance inspection process for a complex, production level part. The finite element based analysis can also provide a means to computationally test the sensitivity of the frequencies to various possible defects such as porosity or oxide inclusions especially in the high stress regions that the part will experience in service.

99 GENERAL AND MISCELLANEOUS↗

WE-A-12A-01: Medical Physics 1.0 to 2.0, Session 2: Radiography, Mammography and Fluoroscopy

Medical Physics 2.0 is a bold vision for an existential transition of clinical imaging physics in face of the new realities of value-based and evidencebased medicine, comparative effectiveness, and meaningful use. It speaks to how clinical imaging physics can expand beyond traditional insular models of inspection and acceptance testing, oriented toward compliance, towards team-based models of operational engagement, prospective definition and assurance of effective use, and retrospective evaluation of clinical performance. Organized into four sessions of the AAPM, this particular session focuses on three specific modalities as outlined below. Radiography 2.0: The development of electronic capture in recent years has changed the landscape and spurred reinvestment by healthcare providers. The radiography presentation will explore how the diagnostic medical physicist must adapt to these changes to support radiographic imaging, and how she/he can add value in radiography practice over the next 5-10 years. Topics of discussion include new metrology of evaluation, new models of clinical engagement, and effective integration of new technologies. Mammography 2.0: Mammography has been an interesting testing ground on the effectiveness of close involvement of medical physicists with equipment in the past twenty years. The outcomes have clearly shown major improvements in image quality and significant reduction in the average glandular dose. However, the medical physicist's role in mammography has been largely focused to annual surveys and with limited input on operational issues with image artifacts, optimal mammographic acquisition mode and problems with image quality. This mammography presentation will address why and how medical physicists must be prepared to address the new models of practice that include new metrics of performance and the integration of new technologies (DBT, syncretized mammograms, contrast mammography, breast CT) into clinical practice. Fluoroscopy 2.0: Physics support of fluoroscopy should be operationally as opposed to compliance focused. Testing protocols must address new hardware, acquisition methods, and image processing. Future available tools are discussed. Proper configuration of acquisition parameters (focal spot size, voltage and added filter, tube current, pulse width, pulse rate, scatter removal) as a function of patient size from the neonate to bariatric patient is key to providing diagnostic image quality at properly managed radiation doses. Learning Objectives: Appreciate the limitations of the currently available tools and techniques in clinical medical physics in radiography, mammography, and fluoroscopy, and ways to improve upon current deficiencies. Appreciate the changing environment of imaging practice and the need for the medical physicist to be an expert consultant and educator in a capacity that extends beyond the annual survey of equipment. Understand the status of the rapidly changing environment in breast imaging from planar imaging to tomosynthesis and possibly to breast CT. Identify appropriate configuration of acquisition parameters as a function of patient size to manage radiation dose and ensure diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

MO-AB-BRA-02: A Novel Scatter Imaging Modality for Real-Time Image Guidance During Lung SBRT

Purpose: A novel scatter imaging modality is developed and its feasibility for image-guided radiation therapy (IGRT) during stereotactic body radiation therapy (SBRT) for lung cancer patients is assessed using analytic and Monte Carlo models as well as experimental testing. Methods: During treatment, incident radiation interacts and scatters from within the patient. The presented methodology forms an image of patient anatomy from the scattered radiation for real-time localization of the treatment target. A radiographic flat panel-based pinhole camera provides spatial information regarding the origin of detected scattered radiation. An analytical model is developed, which provides a mathematical formalism for describing the scatter imaging system. Experimental scatter images are acquired by irradiating an object using a Varian TrueBeam accelerator. The differentiation between tissue types is investigated by imaging simple objects of known compositions (water, lung, and cortical bone equivalent). A lung tumor phantom, simulating materials and geometry encountered during lung SBRT treatments, is fabricated and imaged to investigate image quality for various quantities of delivered radiation. Monte Carlo N-Particle (MCNP) code is used for validation and testing by simulating scatter image formation using the experimental pinhole camera setup. Results: Analytical calculations, MCNP simulations, and experimental results when imaging the water, lung, and cortical bone equivalent objects show close agreement, thus validating the proposed models and demonstrating that scatter imaging differentiates these materials well. Lung tumor phantom images have sufficient contrast-to-noise ratio (CNR) to clearly distinguish tumor from surrounding lung tissue. CNR=4.1 and CNR=29.1 for 10MU and 5000MU images (equivalent to 0.5 and 250 second images), respectively. Conclusion: Lung SBRT provides favorable treatment outcomes, but depends on accurate target localization. A comprehensive approach, employing multiple simulation techniques and experiments, is taken to demonstrate the feasibility of a novel scatter imaging modality for the necessary real-time image guidance.

60 APPLIED LIFE SCIENCES↗

Theory-guided design of duplex-phase multi-principal-element alloys

Density-functional theory (DFT) is used to identify phase-equilibria in multi-principal-element and high-entropy alloys (MPEAs/HEAs), including duplex-phase and eutectic microstructures. Here, a combination of composition-dependent formation energy and electronic-structure-based ordering parameters were used to identify a transition from FCC to BCC favoring mixtures, and these predictions experimentally validated in the Al-Co-Cr-Cu-Fe-Ni system. A sharp crossover in lattice structure and dual-phase stability as a function of composition were predicted via DFT and validated experimentally. The impact of solidification kinetics and thermodynamic stability was explored experimentally using a range of techniques, from slow (castings) to rapid (laser remelting), which showed a decoupling of phase fraction from thermal history, i.e., phase fraction was found to be solidification rate-independent, enabling tuning of a multi-modal cell and grain size ranging from nanoscale through macroscale. Strength and ductility tradeoffs for select processing parameters were investigated via uniaxial tension and small-punch testing on specimens manufactured via powder-based additive manufacturing (directed-energy deposition). This work establishes a pathway for design and optimization of next-generation multiphase superalloys via tailoring of structural and chemical ordering in concentrated solid solutions.

36 MATERIALS SCIENCE↗

Novel, dually radiolabeled peptides for simultaneous monitoring of enzymatic activity and protein targets

This application investigated a novel imaging approach to develop methods to incorporate multiple radionuclides into a single peptide at chemoselective sites for simultaneous monitoring of cell-bound protein targets as well as specific enzymatic activity, both of which are associated with enhanced tumor growth and metastasis. This imaging construct was synthesized in such a manner so that the PET radionuclide will remain associated with the tumor cells and the SPECT radionuclide was cleaved from the imaging agent. Measurement of the PET agent only will yield information about the tumor marker density while measurement of the amount of co-localization and mismatch of the two radionuclides will yield information about the enzymatic activity. This coincident measuring technique using both PET and SPECT agents allows us to draw correlations involving the interactions of enzymes (cathepsin, serine-protease urokinase (uPA) and matrix metalloproteases) and other cellular proteins which play a role in cancer growth and metastasis. This technique will allow for studies in xenograft or genetic models of cancer in the same animal at the same time, thus eliminating problems that may occur when trying to invoke comparisons across animals or timepoints. By using radionuclide imaging as opposed to other imaging modalities, this technique has the potential to be translatable and can exploit the high specific activity probes which can be generated with radiotracers. The proof of principle test of this system investigated simultaneous monitoring of matrix metalloprotease (MMP) activity in the extracellular matrix (ECM) as well as density of integrins on the cell surface, both of which can serve as tumor markers. The outcomes/deliverables of this project were as follows: 1. Peptides were synthesized dually labeled at chemospecific sites with PET and SPECT agents. 2. Stability (intrinsic and to radiolysis) and specific activity of these labeled compounds were determined. 3. The feasibility of using these agents for simultaneous monitoring of MMP-2 enzymatic activity and $\alpha v \beta 3$ integrin density was demonstrated in several in vitro assays Radiotracers can be detected at concentrations up to 1000 fold lower than those labeled with non-radioactive markers (e.g. MRI contrast agents), thus using this technique has the advantage of very high sensitivity to measure these processes in vivo. Hence, the development of an efficient approach to the dual labeling of these molecular probes is embodied within this project, with the end result yielding a molecular imaging probe with the highest specific activity possible. An advantage to this dual labeling approach is the ability to measure two different biochemical processes at the same time, a benefit which is not possible in scans involving protocols utilizing two different radiolabeled agents injected sequentially. Another advantage to this technique is the ability to measure enzymatic activity in the form of substrate cleavage. This can only be achieved with a dually labeled compound as has been demonstrated in the case of FRET1. To our knowledge this is the first instance of a measurement of enzymatic substrate cleavage by a dually labeled PET/SPECT radionuclide imaging agent.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Observations of modal coupling due to bolted joints in an experimental benchmark structure

The goal of this paper is to present a set of measurements from a benchmark structure containing two bolted joints to support future efforts to predict the damping due to the joints and to model nonlinear coupling between the first two elastic modes. Bolted joints introduce nonlinearities in structures, typically causing a softening in the natural frequency and an increase in damping because of frictional slip between the contact interfaces within the joint. These nonlinearities pose significant challenges when characterizing the response of the structure under a large range of load amplitudes, especially when the modal responses become coupled, causing the effective damping and natural frequency to not only depend on the excitation amplitude of the targeted mode, but also the relative amplitudes of other modes. In this work, two nominally identical benchmark structures, known in some prior works as the S4 beam, are tested to characterize their nonlinear properties for the first two elastic modes. Detailed surface measurements are presented and validated through finite element analysis and reveal distinct contact interactions between the two sets of beams. The free-free test structures are excited with an impact hammer and the transient response is analyzed to extract the damping and frequency backbone curves. A range of impact amplitudes and drive points are used to isolate a single mode or to excite both modes simultaneously. Differences in the nonlinear response correlate with the relative strength of the modes that are excited, allowing one to characterize mode coupling. Each of the beams shows different nonlinear properties for each mode, which is attributed to the different contact pressure distributions between the parts, although the mode coupling relationship is found to be consistent between the two. Lastly, the test data key finding are presented in this paper and the supporting data is available on a public repository for interested researchers.

42 ENGINEERING↗

Review of rotating wing dynamic stall: Experiments and flow control

Dynamic stall has been a technical challenge and a fluid dynamical subject of interest for more than fifty years; but in the last decade significant advances have been made in the understanding, prediction, modeling, and control of dynamic stall on rotors. This paper provides a summary of the state of the art of dynamic stall experiments and future directions in the understanding of dynamic stall on rotors. Experimental data sets are discussed, as well the direction of future research for control of dynamic stall. Coordinated testing between airfoils and rotating blades, as well as close integration between computational and experimental studies were found to be productive approaches. Advanced analysis methods, including statistical methods, modal representations, and artificial intelligence methods have led to significant advances in the understanding of dynamic stall. Investigations of dynamic stall control devices have allowed many useful targeted investigations of the transition to separated flow, but have not yet resulted in a commercially implemented device.

42 ENGINEERING↗