Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microsphere”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

“Flower-like” Li 4 Ti 5 O 12 -multiwalled carbon nanotube composite structures with performance as highrate anode-materials for li-ion battery applications and methods of synthesis thereof

A method of fabricating nanocomposite anode material embodying a lithium titanate (LTO)-multi-walled carbon nanotube (MWNT) composite intended for use in a lithium-ion battery includes providing multi-walled carbon nanotube (MWNTs), including nanotube surfaces, onto which functional oxygenated carboxylic acid moieties are arranged, generating 3D flower-like, lithium titanate (LTO) microspheres, including thin nanosheets and anchoring the acid-functionalized MWNTs onto surfaces of the 3D LTO microspheres by π-π interaction strategy to realize the nanocomposite anode material.

25 ENERGY STORAGE↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

Method to synthesize graphene-based amphiphilic janus nanosheets

A facile and scalable method to prepare graphene-based amphiphilic Janus nanosheets with high efficiency utilizing the formation of hydrogen bonding to immobilize graphene oxide (GO) on the surfaces of starch microspheres. After selective functionalization of the exposed surface using alkylamine, amphiphilic Janus nanosheets (AJN) were obtained by releasing the nanosheets from the starch microspheres.

Ren, Zhifeng↗

Fluorescent compositions

An article that includes a fluorescent composition having at least one of a fluorescent sensor compound and organic reporter molecules encapsulated in a microsphere structure. When encapsulated, the fluorescent sensor compound and the organic reporter molecules are distributed in a liquid organic matrix. When non-encapsulated, the remaining one of the fluorescent sensor compound and the organic reporter molecules reside in the matrix. In response to a force applied to the composition sufficient to break at least a portion of the microsphere structure, the fluorescent sensor compound and the organic reporter molecules are transformed into a non-reversible fluorescent state exhibiting a quantum yield greater than 0.2. The fluorescent state is objectively visually verifiable without physically contacting the composition.

Smartt, Heidi A.↗

“Flower-like” LI 4 TI 5 O 12 -multiwalled carbon nanotube composite structures with performance as highrate anode-materials for Li-ion battery applications and methods of synthesis thereof

A method of fabricating nanocomposite anode material embodying a lithium titanate (LTO)-multi-walled carbon nanotube (MWNT) composite intended for use in a lithium-ion battery includes providing multi-walled carbon nanotube (MWNTs), including nanotube surfaces, onto which functional oxygenated carboxylic acid moieties are arranged, generating 3D flower-like, lithium titanate (LTO) microspheres, including thin nanosheets and anchoring the acid-functionalized MWNTs onto surfaces of the 3D LTO microspheres by π-π interaction strategy to realize the nanocomposite anode material.

Wong, Stanislaus S.↗

Effects of light polarization in photonic nanojet

Illumination plays a key role in getting high resolution imaging. Photonic nanojet is a new lighting system. Since the transverse beam width of the nanojet can reach λ/3, photonic nanojet is usually considered to be the key point for the explanation of the high-resolution microsphere assisted microscopy. However, the polarization of photonic nanojet are usually out of attention. In this work, we investigate the photonic nanojets formed by illuminating a dielectric microcylinder by two plane waves with different linear polarizations. The influences of wavelength and refractive index contrast between the microcylinder and its surrounding, and the cases illuminated by the Gaussian beam are also studied. Numerical results demonstrate that the TM polarization can generate a wider nanojet waist than the TE polarization, and this is produced by the longitudinal component of the TM-polarization illumination. When the Gaussian beam width becomes larger than diameter of the cylinder, the nanojet waists become smaller than that obtained by the cylinder under a plane wave. At last, the reason why the TE polarization has a thinner nanojet waist is given, it is related to the longitudinal component making light transmission far away from optical axis.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structure of polystyrene latex particles determined by electron microscopy

The structures of individual polystyrene microspheres obtained in the presence of organosilicon surfactants were studied by transmission electron microscopy. The density of the macro-molecule distribution over the cross section of particles was determined. The synthesized latex particles have a core—shell structure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nitrogen-doped hollow carbon nanospheres for highly sensitive electrochemical sensing of nitrobenzene

Highlights: • NHCPs were prepared using MSM as a template and PDA as carbon and nitrogen precursor. • NHCPs-750 with high content of pyrindinic N showed good electrocatalytic performance. • A sensitive electrochemical sensor for NB was developed based on the NHCPs-750–GCE. - Abstract: Following hard template method, nitrogen–doped hollow carbon nanospheres (NHCPs) were successfully prepared by using monodisperse silica microspheres as a template and dopamine as carbon and nitrogen precursor. A series of NHCPs-x samples with different pyrolysis temperatures were reported. The composite material formation was characterized by detailed methods (e.g., X-ray photoelectron spectroscopy, Fourier transform infrared spectroscopy, scanning electron microscopy and transmission electron microscopy). Results indicated that NHCPs treated at 750 °C with highest amounts of pyrindinic N showed improved electro-catalytic activity for nitrobenzene (NB) in neutral solution. NHCPs-750 can be developed as an effective sensing platform for the detection of NB, which showed high activity and superior analytical performance, such as a wide linear range of 5–2610 μM, a high sensitivity of 436 μAmM{sup −1}, and a low limit of detection of 2.29 μM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Evaluation of the synergistic effect between slow photons and electron trapping on the photocatalytic properties of TiO2 photonic crystals

Highlights: • We report the preparation of titanium dioxide photonic crystals (PCs) having two pore sizes. • Electronic band gap (BG) and photonic band gap (PBG) were determined with the use of UV–vis spectroscopy. • The position of PBG was affected by the pore size of PC. • Metallic silver (electron trapping centers) were generated on the surface of both types of PCs by a photoreduction of silver Ag{sup +} ions. • Photocatalytic properties of silver-modified TiO{sub 2} photonic crystals were enhanced by synergistic effect caused by overlapping the edges of PBG and BG combined with electron trapping by AgNPs. - Abstract: Titanium dioxide photonic crystals (PCs) were obtained using the sol-gel method and polystyrene (PS) microspheres as a template with two different diameters: 300 nm and 460 nm. The resulting materials were labeled as PC-300 and PC-460. In the following step, PCs were modified with silver nanoparticles (AgNPs) generated by the photoreduction of silver Ag{sup +} ions. The obtained PCs were denoted as AgNPs/PC-300 and AgNPs/PC-460. The size of the AgNPs were 28 nm ± 2 nm for the AgNPs/PC-300 and 21 nm ± 1 nm for AgNPs/PC-460. The characteristic features of TiO{sub 2} PCs, such as electronic band gap (BG), photonic band gap (PBG) and an occurrence of slow photon effect (SPE), were determined with the use of UV–vis spectroscopy. The photocatalytic performance of the prepared PCs was defined by monitoring the photodegradation rates of Rhodamine B (RhB) measured in the presence of PC-300, PC-460, AgNPs/PC-300, AgNPs/PC-460 and non-porous TiO{sub 2} coating (NPC) as reference material. It was found that the appropriate utilization of SPE by overlapping the edge of PBG with semiconductor BG and electron trapping by the presence of AgNPs exerted a strong synergistic effect on the photocatalytic properties of AgNPs/PCs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Decreases in bone blood flow and bone material properties in aging Fischer-344 rats

The purpose of this study was to quantify precisely aging-induced changes in skeletal perfusion and bone mechanical properties in a small rodent model. Blood flow was measured in conscious juvenile (2 months old), adult (6 months old), and aged (24 months old) male Fischer-344 rats using radiolabeled microspheres. There were no significant differences in bone perfusion rate or vascular resistance between juvenile and adult rats. However, blood flow was lower in aged versus adult rats in the forelimb bones, scapulas, and femurs. To test for functional effects of this decline in blood flow, bone mineral density and mechanical properties were measured in rats from these two age groups. Bone mineral density and cross-sectional moment of inertia in femoral and tibial shafts and the femoral neck were significantly larger in the aged versus adult rats, resulting in increased (+14%-53%) breaking strength and stiffness. However, intrinsic material properties at midshaft of the long bones were 12% to 25% lower in the aged rats. Although these data are consistent with a potential link between decreased perfusion and focal alterations in bone remodeling activity related to clinically relevant bone loss, additional studies are required to establish the mechanisms for this putative relationship.

Non-NASA Center↗

Selected contribution: redistribution of pulmonary perfusion during weightlessness and increased gravity

To compare the relative contributions of gravity and vascular structure to the distribution of pulmonary blood flow, we flew with pigs on the National Aeronautics and Space Administration KC-135 aircraft. A series of parabolas created alternating weightlessness and 1.8-G conditions. Fluorescent microspheres of varying colors were injected into the pulmonary circulation to mark regional blood flow during different postural and gravitational conditions. The lungs were subsequently removed, air dried, and sectioned into approximately 2 cm(3) pieces. Flow to each piece was determined for the different conditions. Perfusion heterogeneity did not change significantly during weightlessness compared with normal and increased gravitational forces. Regional blood flow to each lung piece changed little despite alterations in posture and gravitational forces. With the use of multiple stepwise linear regression, the contributions of gravity and vascular structure to regional perfusion were separated. We conclude that both gravity and the geometry of the pulmonary vascular tree influence regional pulmonary blood flow. However, the structure of the vascular tree is the primary determinant of regional perfusion in these animals.

short duration↗

Regional ventilation-perfusion distribution is more uniform in the prone position

The arterial blood PO(2) is increased in the prone position in animals and humans because of an improvement in ventilation (VA) and perfusion (Q) matching. However, the mechanism of improved VA/Q is unknown. This experiment measured regional VA/Q heterogeneity and the correlation between VA and Q in supine and prone positions in pigs. Eight ketamine-diazepam-anesthetized, mechanically ventilated pigs were studied in supine and prone positions in random order. Regional VA and Q were measured using fluorescent-labeled aerosols and radioactive-labeled microspheres, respectively. The lungs were dried at total lung capacity and cubed into 603-967 small ( approximately 1.7-cm(3)) pieces. In the prone position the homogeneity of the ventilation distribution increased (P = 0.030) and the correlation between VA and Q increased (correlation coefficient = 0.72 +/- 0.08 and 0.82 +/- 0.06 in supine and prone positions, respectively, P = 0.03). The homogeneity of the VA/Q distribution increased in the prone position (P = 0.028). We conclude that the improvement in VA/Q matching in the prone position is secondary to increased homogeneity of the VA distribution and increased correlation of regional VA and Q.

NASA Program Biomedical Research and Countermeasur↗

Spatial distribution of venous gas emboli in the lungs

The distribution of gaseous pulmonary emboli is presumed to be determined by their buoyancy. We hypothesized that regional pulmonary blood flow may also influence their distribution. Therefore, pulmonary blood flow was measured in supine, anesthetized dogs with use of 15-microm fluorescent microspheres at baseline and during N(2) embolism. The animals were killed, and the lungs were excised, air-dried, and diced into approximately 2-cm(3) pieces with weights and spatial coordinates recorded. Embolism was defined as a >10% flow decrease relative to baseline. Vertically, the incidence of embolism increased substantially by 6 +/- 1% per additional centimeter in height compared with baseline (P = 0.0003). Embolism also increased radially by 3 +/- 1%/cm from the hilum (P = 0.002). There was a weaker but statistically significant increase in embolism to pieces with greater baseline flow, 9 +/- 2% for every 1. 0 increase in relative baseline flow (P = 0.008). We conclude that the distribution of gaseous emboli is influenced by buoyancy and flow dynamics within the pulmonary vasculature.

NASA Discipline Cardiopulmonary↗

Contribution of the vertebral artery to cerebral circulation in the rat snake Elaphe obsoleta

Blood supplying the brain in vertebrates is carried primarily by the carotid vasculature. In most mammals, cerebral blood flow is supplemented by the vertebral arteries, which anastomose with the carotids at the base of the brain. In other tetrapods, cerebral blood is generally believed to be supplied exclusively by the carotid vasculature, and the vertebral arteries are usually described as disappearing into the dorsal musculature between the heart and head. There have been several reports of a vertebral artery connection with the cephalic vasculature in snakes. We measured regional blood flows using fluorescently labeled microspheres and demonstrated that the vertebral artery contributes a small but significant fraction of cerebral blood flow (approximately 13% of total) in the rat snake Elaphe obsoleta. Vascular casts of the anterior vessels revealed that the vertebral artery connection is indirect, through multiple anastomoses with the inferior spinal artery, which connects with the carotid vasculature near the base of the skull. Using digital subtraction angiography, fluoroscopy, and direct observations of flow in isolated vessels, we confirmed that blood in the inferior spinal artery flows craniad from a point anterior to the vertebral artery connections. Such collateral blood supply could potentially contribute to the maintenance of cerebral circulation during circumstances when craniad blood flow is compromised, e.g., during the gravitational stress of climbing.

NASA Center ARC↗

Redistribution of pulmonary blood flow during unilateral hypoxia in prone and supine dogs

We used fluorescent-labeled microspheres in pentobarbital-anesthetized dogs to study the effects of unilateral alveolar hypoxia on the pulmonary blood flow distribution. The left lung was ventilated with inspired O2 fraction of 1.0, 0.09, or 0.03 in random order; the right lung was ventilated with inspired O2 fraction of 1.0. The lungs were removed, cleared of blood, dried at total lung capacity, then cubed to obtain approximately 1,500 small pieces of lung ( approximately 1.7 cm3). The coefficient of variation of flow increased (P < 0.001) in the hypoxic lung but was unchanged in the hyperoxic lung. Most (70-80%) variance in flow in the hyperoxic lung was attributable to structure, in contrast to only 30-40% of the variance in flow in the hypoxic lung (P < 0.001). When adjusted for the change in total flow to each lung, 90-95% of the variance in the hyperoxic lung was attributable to structure compared with 70-80% in the hypoxic lung (P < 0.001). The hilar-to-peripheral gradient, adjusted for change in total flow, decreased in the hypoxic lung (P = 0.005) but did not change in the hyperoxic lung. We conclude that hypoxic vasoconstriction alters the regional distribution of flow in the hypoxic, but not in the hyperoxic, lung.

NASA Discipline Cardiopulmonary↗

Pulmonary blood flow redistribution by increased gravitational force

This study was undertaken to assess the influence of gravity on the distribution of pulmonary blood flow (PBF) using increased inertial force as a perturbation. PBF was studied in unanesthetized swine exposed to -Gx (dorsal-to-ventral direction, prone position), where G is the magnitude of the force of gravity at the surface of the Earth, on the Armstrong Laboratory Centrifuge at Brooks Air Force Base. PBF was measured using 15-micron fluorescent microspheres, a method with markedly enhanced spatial resolution. Each animal was exposed randomly to -1, -2, and -3 Gx. Pulmonary vascular pressures, cardiac output, heart rate, arterial blood gases, and PBF distribution were measured at each G level. Heterogeneity of PBF distribution as measured by the coefficient of variation of PBF distribution increased from 0.38 +/- 0.05 to 0.55 +/- 0.11 to 0.72 +/- 0.16 at -1, -2, and -3 Gx, respectively. At -1 Gx, PBF was greatest in the ventral and cranial and lowest in the dorsal and caudal regions of the lung. With increased -Gx, this gradient was augmented in both directions. Extrapolation of these values to 0 G predicts a slight dorsal (nondependent) region dominance of PBF and a coefficient of variation of 0.22 in microgravity. Analysis of variance revealed that a fixed component (vascular structure) accounted for 81% and nonstructure components (including gravity) accounted for the remaining 19% of the PBF variance across the entire experiment (all 3 gravitational levels). The results are inconsistent with the predictions of the zone model.

NASA Discipline Cardiopulmonary↗

Microengineering Pressure Sensor Active Layers for Improved Performance

Abstract Pressure sensors play an integral role in a wide range of applications, such as soft robotics and health monitoring. In order to meet this demand, many groups microengineer the active layer—the layer that deforms under pressure and dictates changes in the output signal—of capacitive, resistive/piezoresistive, piezoelectric, and triboelectric pressure sensors in order to improve sensor performance. Geometric microengineering of the active layer has been shown to improve performance parameters such as sensitivity, dynamic range, limit of detection, and response and relaxation times. There are a wide range of implemented designs, including microdomes, micropyramids, lines or microridges, papillae, microspheres, micropores, and microcylinders, each offering different advantages for a particular application. It is important to compare the techniques by which the microengineered active layers are designed and fabricated as they may provide additional insights on compatibility and sensing range limits. To evaluate each fabrication method, it is critical to take into account the active layer uniformity, ease of fabrication, shape and size versatility and tunability, and scalability of both the device and the fabrication process. By better understanding how microengineering techniques and design compares, pressure sensors can be targetedly designed and implemented.

Ruth, Sara Rachel Arussy↗

Transparent and Conductive Inorganic/Polymer‐Composite Encapsulants for Long‐Term Perovskite Solar Cells Operation

An innovative inorganic/polymer-composite encapsulation scheme comprising a polymer-based transparent conductive composite (TCC) coupled with a transparent conductive oxide is introduced to extend the lifetime of moisture-sensitive devices such as perovskite solar cells (PSC). The TCC comprises conductive silver-coated polymethyl methacrylate (Ag-PMMA) microsphere fillers protruding from a transparent non-conductive polymer matrix. TCC samples (5% Ag-PMMA by area) demonstrate high optical transparencies (%T approx. 85% in the 370–1200 nm region), low out-of-plane electrical resistivities (R < 0.2 Ω cm 2 ), and equilibrium permeabilities of less than 1 g mm/m 2 /day, all of which are well-maintained after 1,000 hours of environmental exposure. In practice, the TCC is employed between two indium zinc oxide (IZO) thin films, with the in-plane conductivity of IZO and the out-of-plane conductivity of TCC working collectively to function as a single encapsulating electrode. This encapsulation scheme is exemplified by benchmarking performances of PSCs subjected to accelerated aging conditions of quasi-maximum power point tracking under light soaking in air at 50 °C, 40% R.H. to 60% R.H. Notable improvements in operational lifetimes are observed, with a champion encapsulated PSC maintaining over 90% of its initial efficiency of 21.65% for up to 1,430 hours, compare to less than 300 hours for an unencapsulated control.

14 SOLAR ENERGY↗