Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Mesoporous Thin Film Architectures: Addressing Material Demands through Molecular Self-Assembly

Mesoporous thin films spark interest across a wide range of disciplines due to their tunable nanostructures, large internal surface areas, and strong compatibility with planar optical, electronic, and microfluidic devices. While attention in the porous materials community has shifted toward macroporous or disordered nanoporous systems, a resurgence in mesoporous thin film research is underway, driven by new molecular self-assembly methods, advanced materials chemistry, and improved characterization techniques. The integration of high-χN block copolymer design, kinetically persistent micelle templating, and postdeposition processing protocols now allows control over structural parameters such as pore size, wall thickness, porosity, and connectivity. These advances have overcome many of the thermodynamic and processing constraints that previously limited widespread adoption. Rather than serving only as high-surface-area supports, mesoporous thin films are engineered as active interfaces where responsive chemistries and nanoscale confinement act in tandem. Embedding switchable ligands, thermoresponsive polymers, redox mediators, or ion-selective groups directly within the pore walls enables real-time control over transport, optical, and electrochemical properties. These capabilities open up new directions in adaptive coatings, gated membranes, and fast-response biosensors. To further expand their functional scope, mesoporous films are integrated into hierarchical and multicomponent architectures. Techniques such as triblock terpolymer templating, crack-directed assembly, and nanoimprint lithography allow for control over spatial organization on the micron and submicron scale and pore system orientation. This enables programmable anisotropy, enhanced molecular diffusion, and wavelength-selective photonic behavior, essential for next-generation sensing, catalysis, and energy applications. Such structural and functional complexity requires equally sophisticated characterization. Multimodal and in situ techniques can track material dynamics under operational conditions. Recent progress includes extended-range ellipsometric porosimetry (EP) for hierarchical architectures, vacuum EP for interface energetics, time-resolved EP for diffusion kinetics, and correlative AFM-SAXS mapping. The introduction of advanced neutron-based spectroscopies, particularly quasielastic neutron scattering (QENS), promises to provide real-time access to ion transport dynamics and segmental motion under nanoscale confinement, offering a path toward deeper mechanistic understanding of structure-performance correlations in mesoporous systems. This Account reflects the technical advances made and the interdisciplinary collaborations that have shaped our collective vision. The particular dimensions of mesopores enable us to subtly tune interactions at the molecular, interfacial, and mesoscopic levels that permit us to harness nanoconfinement. What emerges is a versatile, modular platform capable of chemical gating, energy transduction, and sensing with a level of tunability unmatched by other porous materials. We highlight critical challenges including the need for more robust large-area processing, a deeper understanding of dynamic behavior under cycling, and better integration with device-level architectures. Our strategies support the transition of mesoporous thin films into active high-performance components in next-generation energy, environmental, and biomedical systems.

oxides↗

Sensitive Top-Down Proteomics Analysis of a Low Number of Mammalian Cells Using a Nanodroplet Sample Processing Platform

Top-down proteomics is a powerful tool for characterizing genetic variations and post-translational modifications at intact protein level. That being said, one significant technical gap of top-down proteomics is the inability to analyze low amount of biological samples, which limits its access to isolated rare cells, fine-needle aspiration biopsies, and tissue substructures. Herein, we developed an ultrasensitive top-down platform by incorporating a microfluidic sample preparation system, termed nanoPOTS (Nanodroplet Processing in One pot for Trace Samples), into a top-down proteomics workflow. A unique combination of a nonionic detergent dodecyl-ß-D-maltopyranoside (DDM) with urea as protein extraction buffer significantly improved both protein extraction efficiency and sample recovery. We hypothesize that the DDM detergent improves protein recovery by efficiently reducing non-specific adsorption of intact proteins on container surfaces, while urea serves as a strong denaturant to disrupt noncovalent complexes and release intact proteins for downstream analysis. The nanoPOTS-based top-down platform reproducibly and quantitatively identified ~170 to ~620 proteoforms from ~70 to ~770 HeLa cells containing ~10 to ~115 ng of total protein. A variety of post-translational modifications including acetylation, myristoylation, and iron binding were identified using only less than 800 cells. We anticipate the nanoPOTS top-down proteomics platform will be broadly applicable in biomedical researches, particularly where clinical specimens are not available in amounts amenable to standard workflows.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coupling Microdroplet-Based Sample Preparation, Multiplexed Isobaric Labeling, and Nanoflow Peptide Fractionation for Deep Proteome Profiling of the Tissue Microenvironment

There is increasing interest in developing in-depth proteomic approaches for mapping tissue heterogeneity in a cell-type-specific manner to better understand and predict the function of complex biological systems such as human organs. Existing spatially resolved proteomics technologies cannot provide deep proteome coverage due to limited sensitivity and poor sample recovery. Herein, we seamlessly combined laser capture microdissection with a low-volume sample processing technology that includes a microfluidic device named microPOTS (microdroplet processing in one pot for trace samples), multiplexed isobaric labeling, and a nanoflow peptide fractionation approach. The integrated workflow allowed us to maximize proteome coverage of laser-isolated tissue samples containing nanogram levels of proteins. We demonstrated that the deep spatial proteomics platform can quantify more than 5000 unique proteins from a small-sized human pancreatic tissue pixel (∼60,000 μm2) and differentiate unique protein abundance patterns in pancreas. Furthermore, the use of the microPOTS chip eliminated the requirement for advanced microfabrication capabilities and specialized nanoliter liquid handling equipment, making it more accessible to proteomic laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic Barriers to Crystallization of Calcium Barium Carbonates

Metastable carbonates play important roles in geochemistry, biomineralization and serve as model systems for nonclassical theories of nucleation and growth. Balcite (Ca 0.5 Ba 0.5 CO 3 ) is a remarkable carbonate phase that is isostructural with a high-temperature modification of calcite (CaCO 3 ), yet can be synthesized at ambient conditions. Here, we investigate crystallization pathways in the Ba-Ca-CO 3 -H 2 O system, with a focus on the transformation of amorphous calcium barium carbonate (ACBC) to balcite and subsequent decomposition into the equilibrium calcite (CaCO3) and witherite (BaCO 3 ) phases. Density functional theory calculations show that balcite is an unstable solid solution (Ca 1-x BaxCO 3 , R 3¯ m) in the range 0.17 < x < 0.5, but is accessible through the amorphous ACBC precursor for x ≲ 0.5, and predict its decomposition into calcite and witherite. We confirm this pathway experimentally but found demixing to proceed slowly and remain incomplete even after 9 months. Nucleation kinetics of balcite from ACBC was assessed using a microfluidic assay, where increasing barium content led to a surprising increase in the balcite nucleation rate, despite decreasing thermodynamic driving force. We attribute crystallization rates that dramatically accelerate with time to changes in interfacial structure and composition during coarsening of the amorphous precipitate. By carefully quantifying the thermodynamic and kinetic contributions in the multistep crystallization of a metastable carbonate, we produce insights that allow us to better interpret the formation and persistence of metastable minerals in natural and synthetic environments.

36 MATERIALS SCIENCE↗

Metabolites of Tobacco- and E-Cigarette-Related Nitrosamines Can Drive Cu 2+ -Mediated DNA Oxidation

Nitrosamine metabolites resulting from cigarette smoking and E-cigarette (E-cig) vaping cause DNA damage that can lead to genotoxicity. While DNA adducts of metabolites of nitrosamines 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK) and N-nitrosonornicotine (NNN) are well-known tobacco-related cancer biomarkers, only a few studies implicate NNN and NNK in DNA oxidation in humans. NNK and NNN were found in the urine of E-cigarette users who never smoked cigarettes. This paper proposes the first chemical pathways of DNA oxidation driven by NNK and NNN metabolites in redox reactions with Cu 2+ and NADPH leading to reactive oxygen species (ROS). A microfluidic array with thin films of DNA and metabolic enzymes that make metabolites of NNN and NNK in the presence of Cu 2+ and NADPH was used to estimate relative rates of DNA oxidation. Detection by electrochemiluminescence (ECL) employed a new ECL dye [Os(tpy-benz-COOH) 2 ] 2+ that is selective for and sensitive to the primary DNA oxidation product 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) in DNA. Enzyme–DNA films on magnetic beads were used to produce nitrosamine metabolites that enter ROS-forming redox cycles with Cu 2+ and NADPH, and liquid chromatography–mass spectrometry (LC–MS) was used to quantify 8-oxodG and identify metabolites. ROS were detected by optical sensors. Metabolites of NNK and NNN + Cu 2+ + NADPH generated relatively high rates of DNA oxidation. Lung is the exposure route in smoking and vaping, human lung tissue contains Cu 2+ and NADPH, and lung microsomal enzymes gave the highest rates of DNA oxidation in this study. Furthermore, E-cigarette vapor contains 6-fold more copper than that in cigarette smoke, which could exacerbate DNA oxidation.

59 BASIC BIOLOGICAL SCIENCES↗

A Review and Outlook on Experimental Advances and Innovations in Geological CO 2 Storage: Insights from Depleted Gas Reservoirs and Saline Aquifers

Geological storage of carbon dioxide (CO 2 ) in depleted gas reservoirs and deep saline aquifers is a key part of global decarbonization efforts. As carbon capture and storage advances toward commercial-scale deployment, the credibility and scalability of laboratory experiments are increasingly vital for guiding safe and effective field implementation. This review offers a comprehensive, cross-scale evaluation of experimental methodologies, including core flooding, high-pressure, high-temperature systems, microfluidic visualization, and emerging systems such as multilayer commingled/compartmentalized core flooding, 3D-printed micromodels, and AI-powered digital twins. These innovations are demonstrated to enhance representativeness, reproducibility, and real-time insight, thereby addressing the limitations of conventional workflows. A critical analysis of methodological gaps, such as inconsistent pressure–temperature conditions, oversimplified brine chemistry, and a lack of standardization, reveals experimental sources of scale translation errors and performance uncertainty. By comparing the unique challenges of depleted gas reservoirs (such as low water saturation and legacy well leakage) to those of saline aquifers (including pressure buildup and caprock integrity), this review identifies formation-specific priorities for experimental design. Novel contributions include a synthesis of best practices, integration strategies for model calibration, and recommendations for standardizing core handling, saturation procedures, and reporting protocols. Furthermore, this work serves as a guide for developing robust, field-relevant experimental strategies that can increase the deployment and regulatory acceptance of CO 2 storage technologies at scale.

58 GEOSCIENCES↗

Flow-Assisted Selective Mineral Extraction from Seawater

The sustainable production of critical materials from natural sources requires a paradigm shift away from currently used resource-intensive processes. In this paper, we report a single-step, laminar co-flow method (LCM) that leverages non-equilibrium conditions to selectively extract pure Mg(OH) 2 from natural seawater. Conventional seawater-based Mg extraction involves adding individual or a combination of precipitants to obtain Mg(OH) 2 , but the co-existence of Ca 2+ unavoidably results in CaCO 3 impurities requiring additional purification steps. Here we show that the non-equilibrium conditions in LCM achieved using a microfluidics device and by simply co-injecting a NaOH solution with seawater can result in improved selectivity for Mg(OH) 2 unlike in conventional bulk mixing method. The resulting precipitates are characterized for composition and the process yield and purity are optimized through systematic variations of the reaction time and the concentration of NaOH. This is the first demonstration of LCM for selective separation, and as a one-step process that does not rely on novel sorbents, membranes, or external stimuli, it is easy to scale-up. LCM has the potential to be broadly relevant to selective separations from complex feed streams and diverse chemistries—enabling more sustainable materials extraction and processing.

54 ENVIRONMENTAL SCIENCES↗

Transport Modeling of Kinetically Limited Microscale Extraction Systems: Droplet and Supported Liquid Membrane Separations

Microfluidic droplet extraction devices can be used to efficiently measure solute phase transfer kinetics in liquid–liquid extraction systems. In this work, a droplet extraction apparatus was constructed using off-the-shelf and custom 3D printed parts for less than 110 USD. The interfacial kinetics of the transfer of Pu(IV) between an aqueous nitric acid phase and a 5 v/v% tridodecylamine (TDA) in toluene phase were characterized by determining the extent of Pu(IV) transfer between phases at different flow rates. Forward interfacial rate constants calculated from this data using an analytical model are 5.6 × 10 –3 mm s –1 under extraction (aqueous-to-organic solute transfer) conditions and 3.3 × 10 –3 mm s –1 under stripping (organic-to-aqueous solute transfer) conditions. The analytical model is valid when the rate of solute transfer across the interface between the two liquid phases has pseudo-first-order reversible reaction kinetics and is slow relative to the rate of solute transport to the interface. The change in the outlet concentration with residence time determined using the analytical model was compared with the results of a numerical model accounting for advection/diffusion to the interface in addition to kinetically limited interfacial solute transfer. These calculations revealed that for systems with forward interfacial rate constants greater than approximately 10 –2 mm s –1 , the analytical model must be supplemented with a numerical transport model accounting for an additional advection/diffusion mass transfer resistance. This threshold corresponds to a Damköhler number of one. The measured interfacial kinetic rate constants for Pu(IV)/TDA were used in a supported liquid membrane (SLM) numerical model, which showed that the Pu(IV) phase transfer kinetics are fast enough for use in a practical separation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Microwave Heating-Induced Temperature Gradients in Liquid–Liquid Biphasic Systems

Microwaves (MWs) can enable the electrification and intensification of chemical manufacturing. They have been applied to various unit separations, such as drying, distillation, and extraction, entailing gas–liquid and solid–liquid systems. However, a limited quantitative understanding of MW-heated liquid–liquid biphasic systems related to extraction exists. This work measures the temporal and spatial temperature difference between an aqueous and an organic phase in batch and continuous microfluidic modes. We demonstrate permanent temperature differences between phases over 35 °C and spatiotemporal periodic and quasiperiodic oscillations modulated by the flow patterns. The temperature differences are primarily driven by the faster absorption rate of MW irradiation by the aqueous phase versus the slower heat transfer from the aqueous phase to the organic phase. These are amplified by low specific interfacial area and modifications of the electromagnetic field. We employ a multiphysics model to predict the temperature difference in a batch system. The model is in good agreement with the experiments. We demonstrate a strong effect of input power, dielectric properties of organic solvents, the volume of solvents, and the volume ratio between phases on the temperature difference. A simple analytical model describes the temperature difference and provides design principles. Furthermore, the combined approach offers new insights into the design and optimization of the MW-heated biphasic systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid Quantification of 237 U Specific Activity for Nuclear Forensics

In the event of an unattributed nuclear explosion, rapid assessment of the short-lived uranium isotope activity and mass can provide valuable information for subsequent forensic analysis. Rapid analysis in the field is enabled by using microfluidic chemistry and deployable instrumentation. Here, this work presents a flow chemistry system, controlled in LabVIEW, that integrates three functionalities: (1) selective extraction of uranium from the sample matrix via a 3D-printed supported liquid membrane module; (2) UV–visible absorbance spectrophotometry to measure the total uranium concentration in the strip flow; and (3) a portable CdTe γ-ray spectrometer coupled to a 3D-printed flow cell to measure 237 U activity concentration in the strip solution. The system was calibrated using standard solutions, and its functionality was demonstrated using a solution of depleted uranium spiked with 237 U. Uranium concentrations of 40–5000 μg/mL were directly quantified online using a 100 mm optical flow cell, while concentrations of 0.5–10 μg/mL were quantified online using a colorimetric reagent. The mass concentration measurement takes approximately 60 min while the activity concentration via γ-ray spectrometry varies depending on the activity of 237 U, with 1 kBq/mL requiring about 30 min of acquisition time to obtain <10% uncertainty at 1σ. This platform provides a fieldable approach for quantifying uranium mass and radioactivity relevant to postdetonation nuclear debris.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Kinetics and Mechanism of Ce(IV) Phase Transfer by the Neutral Extractants Tributyl Phosphate and N,N -Di(2-ethylhexyl)isobutyramide

Tributyl phosphate and N,N-di(2-ethylhexyl)isobutyramide (DEHiBA) are uranium-selective extractants that could be used to recover low-enriched uranium from commercial used nuclear fuel. The economic viability of liquid-liquid extraction processes for chemical separations depends on both thermodynamic and kinetic considerations. Here we used microfluidic droplet extraction to measure interfacial phase transfer rate constants for the extraction and stripping of Ce(IV), a non-radioactive actinide surrogate. The Damkohler numbers for each system were calculated and the phase transfer processes were determined to be diffusion-limited under all conditions, contrary to prior studies using constant interface stirred cells and single drop methods. A well-extracted 2:1 DEHiBA/Ce(IV) complex in the organic phase was determined from batch distribution studies, suggesting a different extraction mechanism for Ce(IV) compared with poorly extracted Pu(IV). Finally, phase disengagement rates were found to be rapid in both systems, in agreement with other studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaporation and Molecular Beam Scattering from a Flat Liquid Jet

An experimental setup for molecular beam scattering from flat liquid sheets has been developed, with the goal of studying reactions at gas–liquid interfaces for volatile liquids. Specifically, a crossed molecular beam instrument that can measure angular and translational energy distributions of scattered products has been adapted for liquid jet scattering. A microfluidic chip is used to create a stable flat liquid sheet inside vacuum from which scattering occurs, and both evaporation and scattering from this sheet are characterized using a rotatable mass spectrometer that can measure product time-of-flight distributions. This article describes the instrument and reports on the first measurements of evaporation of dodecane and Ne from a Ne-doped dodecane flat jet, as well as scattering of Ne from a flat jet of pure dodecane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CH 3 Radical Generation in Microplasmas for Up-Conversion of Methane

The conversion of methane, CH 4 , into higher value chemicals using low temperature plasmas is challenged by both improving efficiency and selectivity. One path towards selectivity is capturing plasma produced methyl radicals, CH 3 , in a solvent for aqueous processing. Due to the rapid reactions of methyl radicals in the gas phase, the transport distance from production of the CH 3 to its solvation should be short, which then motivates the use of microplasmas. The generation of CH 3 in Ar/CH 4 /H 2 O plasmas produced in nanosecond pulsed dielectric barrier discharge microplasmas is discussed using results from a computational investigation. The microplasma is sustained in the channel of a microfluidic chip in which the solvent flows along one wall or in droplets. CH 3 is primarily produced by electron-impact of and dissociative excitation transfer to CH 4 , as well as CH 2 reacting with CH 4 . CH 3 is rapidly consumed to form C 2 H 6 which, in spite of being subject to these same dissociative processes, accumulates over time, as do other stable products including C 3 H 8 and CH 3 OH. The gas mixture and electrical properties were varied to assess their effects on CH 3 production. CH 3 production is largest with 5% CH 4 in the Ar/CH 4 /H 2 O mixture due to an optimal balance of electron-impact dissociation, which increases with CH 4 percentage, and dissociative excitation transfer and CH 2 reacting with CH 4 , which decrease with CH 4 percentage. Design parameters of the microchannels were also investigated. Increasing the permittivity of the dielectrics in contact with the plasma increased the ionization wave intensity which increased CH 3 production. Increased energy deposition per pulse generally increased CH 3 production as does lengthening pulse length up to a certain point. The arrangement of the solvent flow in the microchannel can also affect the CH 3 density and fluence to the solvent. The fluence of CH 3 to the liquid solvent is increased if the liquid is immersed in the plasma as a droplet or is a layer on the wall where the ionization wave terminates. The solvation dynamics of CH 3 with varying numbers of droplets was also examined. Here, the maximum density of solvated methyl radicals CH 3aq occurs with a large number of droplets in the plasma. However, the solvated CH 3aq density can rapidly decrease due to desolvation, emphasizing the need to quickly react the solvated species in the solvent.

03 NATURAL GAS↗

Are Contact Angle Measurements Useful for Oxide-Coated Liquid Metals?

This work establishes that static contact angles for gallium-based liquid metals have no utility despite the continued and common use of such angles in the literature. In the presence of oxygen, these metals rapidly form a thin (~1–3 nm) surface oxide “skin” that adheres to many surfaces and mechanically impedes its flow. This property is problematic for contact angle measurements, which presume the ability of liquids to flow freely to adopt shapes that minimize the interfacial energy. We show here that advancing angles for a metal are always high (>140°)—even on substrates to which it adheres—because the solid native oxide must rupture in tension to advance the contact line. The advancing angle for the metal depends subtly on the substrate surface chemistry but does not vary strongly with hydrophobicity of the substrate. During receding measurements, the metal droplet initially sags as the liquid withdraws from the “sac” formed by the skin and thus the contact area with the substrate initially increases despite its volumetric recession. Furthermore, the oxide pins at the perimeter of the deflated “sac” on all the surfaces are tested, except for certain rough surfaces. With additional withdrawal of the liquid metal, the pinned angle gets smaller until eventually the oxide “sac” collapses. Thus, static contact angles can be manipulated mechanically from 0° to >140° due to hysteresis and are therefore uninformative. We also provide recommendations and best practices for wetting experiments, which may find use in applications that use these alloys such as soft electronics, composites, and microfluidics.

36 MATERIALS SCIENCE↗

3D Printed Parahydrophobic Surfaces as Multireaction Platforms

We report Parahydrophobic surfaces (PHSs) composed of arrays of cubic μ-pillars with a double scale of roughness and variable wettability were systematically obtained in one step and a widely accessible stereolithographic Formlabs 3D printer. The wettability control was achieved by combining the geometrical parameters (H = height and P = pitch) and the surface modification with fluoroalkyl silane compounds. Homogeneous distribution of F and Si atoms onto the pillars was observed by XPS and SEM-EDAX. A nano-roughness on the heads of the pillars was achieved without any post-treatment. The smallest P values lead to surfaces with static contact angles (CAs) >150° regardless of the H utilized. Interestingly, the relationship 0.6 ≤ H/P ≤ 2.6 obtained here was in good agreement with the H/P values reported for nano- and submicron pillars. Furthermore, experimental CAs, advancing and receding CAs, were consistent with the theoretical prediction from the Cassie–Baxter model. Structures covered with perfluorodecyltriethoxysilane with high H and short P lead to PHSs. Conversely, structures covered with perfluorodecyltrimethoxysilane exhibited a superhydrophobic behavior. Finally, several aqueous reactions, such as precipitation, coordination complex, and nanoparticle synthesis, were carried out by placing the reactive agents as microdroplets on the parahydrophobic pillars, demonstrating the potential application as chemical multi-reaction array platforms for a large variety of relevant fields in microdroplet manipulation, microfluidics systems, and health monitoring, among others.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence Signatures of Rare Earth Metals during Precipitation in Various Conditions

Fluorescence spectroscopy is a widely used sensor methodology that analyzes light emitted from a compound or element as it decays from an excited state. This technique is very sensitive and selective, which is ideal to characterize analytes at lower limits of detection. Key example targets of significant industry and research interest include rare earth elements (REEs) such as dysprosium (Dy) and europium (Eu). These are widely used in advanced technologies including semiconductors, electric vehicle motors, lasers, and permanent magnets. Identifying new sources and responsible reutilization of REEs is essential, and new approaches to extract and recycle REEs could be notably enhanced through the integration of on-line sensors. The sensors can support faster process design, informed scale-up, and cost-effective deployment. This study covers the initial exploration of applying fluorescence-based on-line monitoring to REEs within a precipitation process. This study demonstrates the successful scale-up of a fluorescence -based sensing approach, from stationary cuvettes and small-volume microfluidic devices to continuous flow systems operating at the bench scale (10-25mL). This work also provides initial insight into the challenges of signal’s effects and utility within a turbid environment. Using a modular design for monitoring flowing solutions in a flow tube, fluorescence can be characterized for a variety of analytical targets. In this study, detection performance parameters between the cuvette and flow tube system were compared. Additionally, the response of Dy during precipitation by sodium bicarbonate in the two measurement designs was explored. This letter represents a starting point to bridge the gap between traditional fluorescence sensor measurements in a cuvette to future developments that explore the ability to integrate fluorescence sensors into extraction and separation processes at industrially relevant scales.

fluorescence↗

Scalable Gas Diffusion Electrode Fabrication for Electrochemical CO 2 Reduction Using Physical Vapor Deposition Methods

Electrochemical CO 2 reduction (ECR) promises the replacement of fossil fuels as the source of feedstock chemicals and seasonal storage of renewable energy. While much progress has been made in catalyst development and electrochemical reactor design, few studies have addressed the effect of catalyst integration on device performance. Using a microfluidic gas diffusion electrolyzer, we systematically studied the effect of thickness and the morphology of electron beam (EB) and magnetron-sputtered (MS) Cu catalyst coatings on ECR performance. We observed that EB-Cu outperforms MS-Cu in current density, selectivity, and energy efficiency, with 400 nm thick catalyst coatings performing the best. Additionally, the superior performance of EB-Cu catalysts is assigned to their faceted surface morphology and sharper Cu/gas diffusion layer interface, which increases their hydrophobicity. Tests in a large-scale zero-gap electrolyzer yielded similar product selectivity distributions with an ethylene Faradaic efficiency of 39% at 200 mA/cm 2 , demonstrating the scalability for industrial ECR applications.

36 MATERIALS SCIENCE↗

Understanding Time Dependence on Zinc Metal-Organic Framework Growth Using In Situ Liquid Secondary Ion Mass Spectrometry

The abundance of novel metal-organic framework (MOF) materials continues to increase as more applications are discovered for these highly porous, well-ordered crystalline adsorbents. The simplicity of its constituents allows for the design of new MOFs with virtue of functionality and pore topology towards target adsorbates. However, the fundamental understanding of how these frameworks age during nucleation and growth is mostly limited to speculation from simulation studies. In this effort, we utilize the microfluidic interface of liquid and vacuum in a unique SALVI device to analyze the formation and aging of the benchmark MOF-74 framework using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Principal component analysis (PCA) of the SIMS mass spectra together with ex situ microscopy and porosimetry, provide new insights into the growth and aging process.

Sabale, Sandip R.↗