Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Explainable multi-fidelity Bayesian neural network for distribution system state estimation

Distribution System State Estimation (DSSE) is frequently constrained by limited real-time measurements, the uncertainties introduced by distributed energy resources, and the presence of bad data. To address them, this paper proposes an enhanced Multi-Fidelity Bayesian Neural Network (MFBNN) DSSE approach. A low-fidelity layer based on a Deep Neural Network (DNN) is first pre-trained on pseudo-measurement data to learn fundamental state features. Subsequently, a high-fidelity Bayesian Neural Network (BNN) layer leverages limited but high-quality real-time measurements to refine these features, thereby achieving accurate DSSE. Additionally, the deep SHapley Additive exPlanation (SHAP) is developed to quantify the influence of measurement data on DSSE through dual perspectives of global feature importance and local nodal contributions, establishing a hierarchical explainability framework for machine learning-based DSSE. Comparative studies conducted on the IEEE 13-bus system and a real-world 2135-node system from Dominion Energy demonstrate that the proposed method excels in estimation accuracy, even under situations of high noise levels, bad data, and missing data. Further comparisons with Weighted Least Squares (WLS) and other machine learning-based DSSE approaches verify that the proposed framework offers higher accuracy, improved interpretability, and enhanced robustness.

Bad data↗

Electron polarimetry at EIC

The Electron-Ion Collider will be the first collider to use both polarized electron beams and polarized protons and light ions . This will offer unique opportunities to study the structure of protons and nuclei and answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of the uncertainties are critical for the success of the spin program at the EIC. The requirements for beam polarimetry are non-destructive with uncertainty less than 1%. At the Electron Storage Ring (ESR) and the Rapid Cycling Synchrotron (RCS), the electron beam polarization will be measured using wellestablished Compton polarimetry techniques. However, the EIC Compton polarimeter will face unique challenges, demanding further developments. A Mott polarimeter will also be employed at the source for initial polarization measurements. Both longitudinal and transverse polarization will be measured, with the capability to monitor polarization on a bunch-by-bunch basis. Achieving these precise measurements will be critical to controlling systematic uncertainties and ensuring the overall success of the EIC’s physics objectives.

Zhang, Zhengqiao (ORCID:0009000742521735)↗

Sample shape and boundary dependence of measured transverse thermal properties

In spite of increased interest in thermal Hall measurements for the analysis of insulating quantum materials, there remains large uncertainty in such measurements due to contact misalignment. In this paper, we propose that sample geometry and uncertain boundary conditions provide an additional source of uncertainty in the measurement of $D_{xy}$ or $κ_{xy}$. By running simple simulations in an open source finite-element solver, we demonstrate that measured $D_{xy}$ can be changed by a non-negligible fraction in samples with similar width and length. This geometric corrective factor depends on the distinction between a uniform heat flow and constant temperature boundary couplings to a bath. Sample geometry and boundary conditions can be accounted for through simulation or by using rectangular samples to make thermal Hall measurements more reliable and reproducible. Finally, we detail a contactless optical method for measuring $D_{xy}$ based on an existing photothermal microscope technique. This method is insensitive to the longitudinal diffusivity pollution caused by contact misalignment.

36 MATERIALS SCIENCE↗

Shock initiation of the HMX-based explosive PBX 9012: Experiments, uncertainty analysis, and unreacted equation-of-state

In this study, shock initiation experiments have been carried out on the polymer-bonded explosive PBX 9012 [nominally 90% octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazine (HMX), 10% vinylidene–hexafluoropropylene copolymer (Viton A) by weight] in order to provide calibration data for the explosive’s unreacted equation-of-state (EOS) and shock-to-detonation transition for reactive burn rate calibration. The input pressures covered the range of 1.86–4.43 GPa. This provided run-to-detonation depths ranging from > 22.3 mm for the lowest pressure shot to 4.91 mm at the highest pressure. The relative shock sensitivity of PBX 9012 is compared to other HMX-explosives in terms of the Pop-plot, showing that the studied explosive is more sensitive than other similar HMX-based counterparts (with notable exceptions). The uncertainty in the shock velocity determinations from the shock tracker measurements are also investigated, yielding new uncertainty measures in the generated Hugoniot data and run-to-detonation coordinates. Finally, the unreacted equation-of-state is determined using a linear U s – u p Mie–Grüneisen relation and the Davis reactants EOS analytical form, the latter being more suited for reactive burn modeling.

36 MATERIALS SCIENCE↗

Studies of the muon momentum calibration and performance of the ATLAS detector with $pp$ collisions at $\sqrt{s}=13$ TeV

This paper presents the muon momentum calibration and performance studies for the ATLAS detector based on the $pp$ collisions data sample produced at $\sqrt{s}$ = 13 TeV at the LHC during Run 2 and corresponding to an integrated luminosity of 139 fb –1 . An innovative approach is used to correct for potential charge-dependent momentum biases related to the knowledge of the detector geometry, using the $Z$ → $μ^+$ $μ^–$ resonance. The muon momentum scale and resolution are measured using samples of $J/ψ$ → $μ^+$ $μ^–$ and $Z$ → $μ^+$ $μ^–$ events. A calibration procedure is defined and applied to simulated data to match the performance measured in real data. The calibration is validated using an independent sample of $Υ$ → $μ^+$ $μ^–$ events. At the Z ($J/ψ$) peak, the momentum scale is measured with an uncertainty at the 0.05% (0.1%) level, and the resolution is measured with an uncertainty at the 1.5% (2%) level. The charge-dependent bias is removed with a dedicated in situ correction for momenta up to 450 GeV with a precision better than 0.03 TeV –1 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Zero Power Reactor Database (ZPRD) Development Plan

Past sodium-cooled fast reactors (SFR) were built with an active experimental program in place to support the design and development work. Most of the experimental facilities in the United States that were important for SFR design were shutdown in the 1980s and 1990s. Reactor licensing and construction requires any reactor design to be verified against existing reactor facilities or experimental measurements. With the absence of those experimental facilities, modern SFR projects must rely on historical measurements to demonstrate that the engineering modeling software and data being used for the new reactor design work are reliable. There has been a considerable push in the last 6 years by both DOE and commercial companies to obtain historical experimental measurements that are relevant for SFRs, in particular those with features that are important for the new reactor designs of interest. The zero power reactor experiments carried out at Argonne National Laboratory’s critical facilities (ZPR-3, ZPR-6, ZPR-9, and ZPPR) from the 1950s to the 1980s are some of the best reactor physics experiments on SFR technology that are available today. Of particular interest today are the ZPPR-15 measurements done at the ZPPR facility for the Integral Fast Reactor project in the 1980s as they are in line with most commercial and DOE interests today. In the past 10 years, the measurements done on ZPPR-15 have been processed into both Monte Carlo (MCNP) and deterministic models (MC2-3 and DIF3D) useable for validating the engineering modeling software for key parts of the SFR design work. To achieve this, a detailed model description must be created for the experiment and the experimental measurement that the engineering modeling software is to reproduce. Then, an assessment of the uncertainty on the measured quantity which considers all of the sources of uncertainty in defining the model must be obtained and documented. The models created for ZPPR-15 provide the best validation basis available today for neutronics modeling software. Reference 2 is a good resource to understand how these models were built and how the uncertainties on the measured quantities were derived. The intention of the Zero Power Reactor Database (ZPRD), hosted at frdb.ne.anl.gov, is to make available the experimental measurements and models that have been constructed to-date. Though ZPPR-15 measurements are the primary data requested for validation needs, other measurements on ZPPR, ZPR-6, and ZPR-9 in support of the Clinch River Breeder Reactor (CRBR) and Fast Test Reactor (FFTF) should also be considered important for future software validation needs. In this manuscript, the details of available measurements on ZPR-3, ZPR-6, ZPR-9, and ZPPR facilities are summarized, and a general organization of the web interface is displayed. Many of the documents associated with the measurements are export controlled information so access to the database will also have to be controlled.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Measurement of 𝐵 + →𝜏 + ⁢𝜈 𝜏 branching fraction with a hadronic tagging method at Belle II

We present a measurement of the branching fraction of 𝐵 + →𝜏 + ⁢𝜈 𝜏 decays using 387±6×10 6 ϒ⁡(4⁢𝑆) collected between 2019 and 2022 with the Belle II detector at the SuperKEKB 𝑒 + ⁢𝑒 − collider. We reconstruct the accompanying 𝐵 − meson using the hadronic tagging method, while 𝐵 + →𝜏 + ⁢𝜈 𝜏 candidates are identified in the recoil. We find evidence for 𝐵 + →𝜏 + ⁢𝜈 𝜏 decays at 3.0 standard deviations, including systematic uncertainties. The measured branching fraction is ℬ⁡(𝐵 + →𝜏 + ⁢𝜈 𝜏 )=[1.24±0.41⁢(stat)±0.19⁢(syst)]×10 −4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Use of a controlled experiment and computational models to measure the impact of sequential peer exposures on decision making

It is widely believed that one’s peers influence product adoption behaviors. This relationship has been linked to the number of signals a decision-maker receives in a social network. But it is unclear if these same principles hold when the “pattern” by which it receives these signals vary and when peer influence is directed towards choices which are not optimal. To investigate that, we manipulate social signal exposure in an online controlled experiment using a game with human participants. Each participant in the game decides among choices with differing utilities. We observe the following: (1) even in the presence of monetary risks and previously acquired knowledge of the choices, decision-makers tend to deviate from the obvious optimal decision when their peers make a similar decision which we call the influence decision, (2) when the quantity of social signals vary over time, the forwarding probability of the influence decision and therefore being responsive to social influence does not necessarily correlate proportionally to the absolute quantity of signals. To better understand how these rules of peer influence could be used in modeling applications of real world diffusion and in networked environments, we use our behavioral findings to simulate spreading dynamics in real world case studies. We specifically try to see how cumulative influence plays out in the presence of user uncertainty and measure its outcome on rumor diffusion, which we model as an example of sub-optimal choice diffusion. Together, our simulation results indicate that sequential peer effects from the influence decision overcomes individual uncertainty to guide faster rumor diffusion over time. However, when the rate of diffusion is slow in the beginning, user uncertainty can have a substantial role compared to peer influence in deciding the adoption trajectory of a piece of questionable information.

97 MATHEMATICS AND COMPUTING↗

The DESI One-Percent Survey: exploring a generalized SHAM for multiple tracers with the UNIT simulation

We perform SubHalo Abundance Matching (SHAM) studies on UNIT simulations with {σ, V ceil , v smear }-SHAM and {σ, V ceil , $f$ sat }-SHAM. They are designed to reproduce the clustering on 5–30 h -1 Mpc of luminous red galaxies (LRGs), emission-line galaxies (ELGs), and quasi-stellar objects (QSOs) at 0.4 < z < 3.5 from DESI (Dark Energy Spectroscopic Instrument) One Percent Survey. V ceil is the incompleteness of the massive host (sub)haloes and is the key to the generalized SHAM. v smear models the clustering effect of redshift uncertainties, providing measurements consistent with those from repeat observations. A free satellite fraction $f$ sat is necessary to reproduce the clustering of ELGs. We find ELGs present a more complex galaxy–halo mass relation than LRGs reflected in their weak constraints on σ. LRGs, QSOs, and ELGs show increasing V ceil values, corresponding to the massive galaxy incompleteness of LRGs, the quenched star formation of ELGs and the quenched black hole accretion of QSOs. For LRGs, a Gaussian v smear presents a better profile for subsamples at redshift bins than a Lorentzian profile used for other tracers. The impact of the statistical redshift uncertainty on ELG clustering is negligible. The best-fitting satellite fraction for DESI ELGs is around 4 per cent, lower than previous estimations for ELGs. The mean halo mass log 10 ($\langle$M vir $\rangle$) in h -1 M ⊙ for LRGs, ELGs, and QSOs are 13.16 ± 0.01, 11.90 ± 0.06, and 12.66 ± 0.45, respectively. Our generalized SHAM algorithms facilitate the production of multitracer galaxy mocks for cosmological tests.

79 ASTRONOMY AND ASTROPHYSICS↗

Vertical profiles of light absorption and scattering associated with black carbon particle fractions in the springtime Arctic above 79° N

Despite the potential importance of black carbon (BC) for radiative forcing of the Arctic atmosphere, vertically resolved measurements of the particle light scattering coefficient (σ sp ) and light absorption coefficient (σ ap ) in the springtime Arctic atmosphere are infrequent, especially measurements at latitudes at or above 80° N. Here, relationships among vertically distributed aerosol optical properties (σap, σsp and single scattering albedo or SSA), particle microphysics and particle chemistry are examined for a region of the Canadian archipelago between 79.9 and 83.4° N from near the surface to 50 hPa. Airborne data collected during April 2015 are combined with ground-based observations from the observatory at Alert, Nunavut and simulations from the Goddard Earth Observing System (GEOS) model, GEOS-Chem, coupled with the TwO-Moment Aerosol Sectional (TOMAS) model (collectively GEOS-Chem–TOMAS; Kodros et al., 2018) to further our knowledge of the effects of BC on light absorption in the Arctic troposphere. The results are constrained for σsp less than 15 Mm -1 , which represent 98% of the observed σsp, because the single scattering albedo (SSA) has a tendency to be lower at lower σsp, resulting in a larger relative contribution to Arctic warming. At 18.4 m 2 g -1 , the average BC mass absorption coefficient (MAC) from the combined airborne and Alert observations is substantially higher than the two averaged modelled MAC values (13.6 and 9.1 m2 g -1 ) for two different internal mixing assumptions, the latter of which is based on previous observations. The higher observed MAC value may be explained by an underestimation of BC, the presence of small amounts of dust and/or possible differences in BC microphysics and morphologies between the observations and model. In comparing the observations and simulations, we present σap and SSA, as measured, and σ ap 2 and the corresponding SSA to encompass the lower modelled MAC that is more consistent with accepted MAC values. Median values of the measured σap, rBC and the organic component of particles all increase by a factor of 1.8±0.1, going from near-surface to 750 hPa, and values higher than the surface persist to 600 hPa. Modelled BC, organics and σap agree with the near-surface measurements but do not reproduce the higher values observed between 900 and 600 hPa. The differences between modelled and observed optical properties follow the same trend as the differences between the modelled and observed concentrations of the carbonaceous components (black and organic). Model-observation discrepancies may be mostly due to the modelled ejection of biomass burning particles only into the boundary layer at the sources. For the assumption of the observed MAC value, the SSA range between 0.88 and 0.94, which is significantly lower than other recent estimates for the Arctic, in part reflecting the constraint of σsp<15 Mm -1 . The large uncertainties in measuring optical properties and BC, and the large differences between measured and modelled values here and in the literature, argue for improved measurements of BC and light absorption by BC and more vertical profiles of aerosol chemistry, microphysics and other optical properties in the Arctic.

54 ENVIRONMENTAL SCIENCES↗

Toward an improved nonlocal thermodynamic equilibrium model for more predictive simulations of ignition scale hohlraums

Recently, nonlocal thermodynamic equilibrium (NLTE) modeling has been identified as the primary reason for discrepant predictions of the peak neutron production time in indirectly driven inertial confinement fusion (ICF) platforms. It has also been observed that predictions of collisional excitation rates differ by as much as 50% from measurements. Theoretical uncertainties in dielectronic recombination rates have also been posited as possibly contributing to errors in NLTE predictions. This work examines the impact of multipliers on collisional excitation and dielectronic recombination rates on simulations of a directly driven gold sphere and an indirect drive ICF implosion. It is found that multipliers on the collisional excitation rates have a strong impact on radiant intensity and electron temperature and a weaker impact on ionization state, whereas multipliers on dielectronic recombinations rates strongly impact ionization state with a smaller impact on radiant intensity and electron temperature. A self-consistent NLTE model which places multipliers on differing transitions, as motivated by experimental measurements and more detailed atomic physics predictions, improves agreement but does not completely eliminate discrepancies with measurements of the radiant intensity within the 2–4 keV spectral range.

Farmer, W. A. [Lawrence Livermore National Laborat↗

Unbalanced Nested Random Effects Estimation of Variance Components

To investigate the contributing factors of variance in the measurement of an iodine 127 (127I) sample, we implement a nested random effects analysis of variance (ANOVA). Historically, the reported uncertainty on a measurement of 127I has been obtained by methods of forward uncertainty propagation because there is typically only one replicate of a given sample for which to estimate the uncertainty. When samples are processed there are several types of quality control (QC) standards analyzed along-side the unknown samples with two to five replicates for each. Assuming the variance observed in these replicate QC standards is representative of that of the unknown samples, we use these data in a nested random effects ANOVA to estimate the total uncertainty of a measurement. We demonstrate this approach with two sets of measurements from Idaho National Laboratory and compare the results with the forward uncertainty propagation approach. Variance component estimates for the coarsest level of the nesting structure were most imprecise because replicates were most limited at these levels. We find that the results largely agree between forward propagation and ANOVA, and the greatest contributors of variance are due to instrument variation and chemical processing, with human processing being among the smallest contributors. This analysis provides reassurance that the reported uncertainties using forward propagation are reasonable and the process is well controlled. We propose a future designed experiment to increase replicates at the coarsest level of the hierarchy to improve estimates of these variance components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Update on the High Precision Titration Method for Uranium Assay Supported by NBL Program Office

The NBL Program Office (NBL PO) has coordinated with Oak Ridge National Laboratory (ORNL) to implement the High Precision Titration (HPT) method for uranium assay measurements. The measurement method has been successfully developed and qualified, therefore ORNL has progressed to performing analyzes critical to the mission of the NBL PO. The HPT method is vital to producing the next generation of certified reference materials for uranium assay and isotopic abundance. The work described here focused on establishing traceability of the method to the NIST SRM 136 potassium dichromate series, and focused on investigating small differences between SRM 136e and 136f. The NBL PO evaluated the history of all of its primary uranium reference materials, including CRM 112A natural uranium metal, and worked with NIST in investigating the small differences in the dichromate SRM’s. ORNL performed comparative experiments on SRM 136e and 136f using CRM 112A. The results of the experiment will be presented here, along with NBL PO’s plans to re-evaluate the CRM 112A certified uncertainty to comply with JCGM 100, “Guide to the expression of uncertainty in measurement.”

Rogers, Kayron↗

Probing Systematic Bias in Low-redshift Type Ia Supernova Measurements by Cross Analyzing Surface Brightness and Hubble Residuals

For low-redshift (z < 0.1) SN Ia samples used in several cosmological analyses over the past decade, we probe for systematic bias by looking for correlations between surface brightness (SB) measurements and Hubble residuals (HR). For 292 SNe Ia, we measure SB at the location of the SN Ia from publicly available Pan-STARRS (PS1) images. The Hubble residuals are from two recent measurements with low-z SNe Ia that overlap the PS1 footprint: (1) the DES 3 yr cosmology analysis, with 120 overlapping low-z SNe Ia from the Harvard-Smithsonian Center for Astrophysics surveys and Carnegie Supernova Project, and (2) the PS1 single-telescope analysis, with 172 overlapping low-z SNe Ia from the Foundation Supernova Survey. This study is motivated by previous reports of anomalous inefficiencies and flux scatter for transients on bright galaxies. Here, we compare HR distributions of the bright and faint halves of the SB distribution: the mean HR values differ by ${\rm{\Delta }}\overline{\mathrm{HR}}$ = 0.031 ± 0.018, consistent with no difference at the 2σ level. We also perform a Kolmogorov–Smirnov (KS) test for the bright and faint half HR distributions, and conclude that the two distributions are statistically consistent with a KS p-value of 0.07. However, if future studies with larger data sets find ${\rm{\Delta }}\overline{\mathrm{HR}}\sim 0.03$ with high significance, this difference would be a leading systematic uncertainty in measurements of the dark energy equation of state, w.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of modeling and experimental data inconsistencies from burst testing for high-burnup commercial fuel rod applications

Fuel fragmentation, relocation, and dispersal are some of the largest issues remaining in the nuclear industry before rod-average burnup can be increased beyond 62 GWd/tU. The issue is primarily related to the potential for fuel to be dispersed into the reactor primary system, which may increase public risk. One way to prevent dispersal is to avoid cladding burst. The objective of this work is to support the high burnup safety case by evaluating cladding burst under high-burnup, full-length fuel rods and to identify uncertainties that could improve model predictions. The results of this analysis will evaluate realistic, prototypic loss-of-coolant accident (LOCA) conditions; support future cladding burst test designs; and inform the development of mechanistic material models. Realistic high-burnup operating conditions were implemented in the BISON fuel performance code to simulate steady-state and LOCA transient fuel rod evolution to the point at which cladding burst occurred. Parametric studies are performed to assess code response to changes in rod internal pressures and heating rates. Results were compared with simulated LOCA experiments to identify inconsistencies between commercial fuel rod analysis and experimental validation. The representative full-length fuel rod LOCA simulation results did not agree with cladding burst tests. Cladding burst tests indicated burst occurring well below (100–150 °C) those calculated in the full-length fuel rod LOCA analysis. Further investigation indicated that the cladding burst tests do not appear to be representative for full-length fuel rods. The inconsistency investigated in this work showed that the differences between the BISON simulation and the experiment's cladding burst conditions arise from an incomplete characterization of the cladding surface temperature, detailed rodlet characterization, lack of cladding strain measurements, and uncertainty in the cladding creep and failure models.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A new generation of uranium coincidence fast neutron collars for assay of LWR fresh fuel assemblies

The active uranium neutron coincidence collar provides a means of non-destructively assaying the fissile linear density of Light Water Reactor fresh fuel assemblies containing low enriched uranium. These neutron collars can operate in two modes: a thermal and a fast mode. In fast mode, a neutron collar has an added cadmium (Cd) liner in the sample cavity of the detector to reduce the impact of the burnable poison (thermal neutron absorber) on the detector signal (doubles). The main advantage for operating in fast mode is a detected signal that is less dependent of the burnable neutron poison content and thus less dependent on facility operator declarations. The drawback is that operating in fast mode requires a longer measurement time (~hour vs tens of minutes for thermal mode) to achieve the statistically needed precision in the measurements. The trend in the modern reactor fuel assemblies is moving to higher burnup by using higher initial enrichment and, consequently, a higher number of burnable poison rods to compensate the initial neutron reactivity. The increase of the burnable poison loading has motivated the development of a new generation of high efficiency fast neutron collars to allow practical measurements in-field by nuclear inspectors. This paper describes the development and performance evaluation of a new generation of neutron collars, for both boiling water reactor (BWR) and pressurized water reactor (PWR) fuels, jointly developed between the US Department of Energy, through Los Alamos National Laboratory, and the Euratom Safeguards Directorate of the European Commission. In this work, we present here calibrations with reference fuel assemblies at Los Alamos National Laboratory as well as the results of in-field measurement campaigns in fuel fabrication plants with modern commercial fuel assemblies. The experimental results show that a typical PWR verification can be made in a total time of 30 min with an uncertainty in the measured mass of 2% at one standard deviation (1σ). A BWR verification can be made in 47 min with an uncertainty in the measured mass of 1.9% at 1σ, or a total time of 20 min with 1σ uncertainty in the measured mass of 2.5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Hadron Polarimetry for the Electron-Ion Collider

The Electron-Ion Collider (EIC) will be the first collider to use both polarized electron beams and polarized proton and light ion beams. It will therefore offer unique opportunities to study the structure of nucleons and to answer fundamental questions in QCD. The uncertainties on the polarization measurement translate directly into the uncertainties of final physics observables. Hence, a precise measurement of the hadron beam polarization and a good control of systematic uncertainties are critical for the success of the spin program at the EIC. Contrary to the case of electron beam polarimetry, which uses physical processes derived from first principles that allow a high precision extraction of the electron beam polarization, for hadron beams no such process is available. The currently best used methods rely on the process of elastic scattering in the Coulomb-Nuclear Interference (CNI) region, for which there are only effective models available. The experience from RHIC, the only existing polarized proton collider, will be detailed and the challenges of the measurements at the EIC will be addressed. In particular, measurements of the present RHIC polarimeters and simulations of the future EIC polarimeters will be presented.

Nunes, Ana Sofia↗