Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Mass Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Designing Porous Ion Emitters for Thermal Ionization Mass Spectrometry: Evaluating Metal-Organic Frameworks

In this work we describe the first exploration of metal-organic frameworks (MOFs) as ‘next generation’ ion emitters for thermal ionization mass spectrometry (TIMS). MOFs were identified as promising candidates for this application given the synthetic control over their desired structural properties. This tunability results in well-ordered, high surface area, high porosity frameworks with targeted sorption affinities. Here we explored an aluminum-based, bipyridine-containing MOF (MOF-253) with and without incorporating the high work function metal, rhenium (Re). After analysis of a Nd-bearing MOF, we hypothesized that the well-dispersed, sponge-like interconnected network of the degraded structure would enhance Nd ionization more than traditional TIMS loading activators (i.e., phosphoric acid). Compared to filaments loaded with phosphoric acid that require an additional benzene carburization step, the Nd ionization efficiencies (atoms detected relative to atoms loaded) for heated filaments loaded with MOF-253 were similar (~1%). Electron microscopy after TIMS analysis demonstrated that the MOF was retained on the filament and, as hypothesized, preserved sub-micron porosity post analysis. While these results are preliminary, they demonstrate that MOFs have potential to enhance ionization and exceed the performance of traditional loading techniques by forming nano-porous ion emitters (nano-PIEs). Thus, further experimentation is likely to exceed this performance through more specific selection of the base MOF structure and modifications to porosity and composition. This work represents a novel application of MOFs and a next step in the pursuit of advanced thermal ionization with potential to expand across the periodic table.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Practical benzylation of N,N -substituted ethanolamines related to chemical warfare agents for analysis and detection by Electron Ionization Gas Chromatography-Mass Spectrometry

The benzylation of three, low-molecular weight N,N-disubstituted ethanolamines related to chemical warfare agents (CWAs) to furnish derivatives with improved Gas Chromatography-Mass Spectrometry (GC-MS) profiles is described. Due to their low molecular weight and polar nature, N,N-disubstituted ethanolamines are notoriously difficult to detect by routine GC-MS analyses during Organisation for the Prohibition of Chemical Weapons (OPCW) proficiency tests (PTs), particularly in scenarios when they are present at low levels (~1-10 ppm) amidst more abundant interferences. Our studies revealed that the optimal derivatization conditions involved the treatment of the ethanolamine with benzyl bromide in the presence of an inorganic base (e.g., Na 2 CO 3 ) in dichloromethane at 55 °C for 2 hours. This optimized set of conditions were then successfully applied to the derivatization of N,N-dimethylethanolamine, N,N-diethylethanolamine and N,N-diisopropylethanolamine present separately at 1 and 10 μg/mL concentrations in a glycerol-rich matrix sample featured in the 48 th OPCW PT. The benzylated derivatives of the three ethanolamines possessed retention times long enough to clear the massive glycerol-containing matrix interferences. In conclusion, the protocol herein is introduced as an alternative method for derivatization of these CWA and pharmaceutically important species and should find broad applicability in laboratories where their routine forensic analysis is carried out.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

R “SHINY” GUI DEVELOPMENT FOR URANIUM ISOTOPIC ANALYSIS WITH MATRIX-ASSISTED IONIZATION MASS SPECTROMETRY

The international nuclear safeguards community continues to seek rapid, accurate, and precise characterization capabilities for the in-field measurement of uranium isotopic compositions in nuclear facilities. Mass spectrometry (MS) is considered the “gold standard” for analysis of relatively long-lived actinides such as uranium (U) and plutonium; however, conventional MS analysis often requires time consuming sample preparation and complex analytical methodologies that are difficult to perform in-field or in-facility. Matrix assisted ionization (MAI) is a novel ambient ionization MS technique (i.e., MAI-MS) that potentially addresses these challenges due to the relative simplicity of the ionization phenomenon and ruggedness of ambient MS instrumentation. Savannah River National Laboratory (SRNL, USA) has demonstrated this technique for nanogram-level 235U/238U isotope ratio measurements within seconds, with percent-level analytical uncertainties capable of discriminating depleted, natural, and low-enriched uranium. Current experimental work on developing MAI methods for uranium isotopic analysis has been enabled by parallel development of a comprehensive MAI-MS data analysis suite at SRNL. Development of this bespoke data analysis software was necessary because commercially available ambient MS software is poorly suited for uranium isotope ratio measurement. The effort leverages the power of R, a popular open-source programming language, and Shiny, an R package providing tools for graphical user interface (GUI) and web interface coding. This software allows researchers without any programming experience to harness and utilize R’s considerable data analysis/visualization power.

LaBone, Elizabeth D.↗

Resource for the Development of Biomedical Accelerator Mass Spectrometry (AMS) Final Report

The NIH Research Resource for Biomedical AMS was originally funded at Lawrence Livermore National Laboratory in 1999 to develop and apply the technology of accelerator mass spectrometry (AMS) in broad- based biomedical research. The Resource’s niche is to fill needs for ultra high sensitivity quantitation when isotope-labeled agents are used. The Research Resource’s Technology Research and Development (TR&D) efforts will focus on the needs of the biomedical research community in the context of seven Driving Biomedical Projects (DBPs) that will drive the Center’s technical capabilities through three core TR&Ds. We will expand our present capabilities by developing a fully integrated HPLC AMS to increase our capabilities for metabolic measurements, we will develop methods to understand cellular processes and we will develop and validate methods for the application of AMS in human studies, which is a growing area of demand by collaborators and service users. In addition, we will continue to support new and ongoing collaborative and service projects that require the capabilities of the Resource. The Center will continue to train researchers in the use of the AMS capabilities being developed, and the results of all efforts will be widely disseminated to advance progress in biomedical research. Towards these goals, our specific aims are to:1.) Increase the value and information content of AMS measurements by combining molecular speciation with quantitation of defined macromolecular isolates. Specifically, develop and validate methods for macromolecule labeling, characterization and quantitation.2.) Develop and validate methods and strategies to enable AMS to become more broadly used in human studies. Specifically, demonstrate robust methods for conducting pharmacokinetic/pharmacodynamics studies in humans and model systems.3.) Increase the accessibility of AMS to the Biomedical research community and the throughput of AMS through direct coupling to separatory instruments.4.) Provide high throughput 14C BioAMS analysis for collaborative and service clients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Applications of Alternate Actinide Calibration on Inductively Coupled Plasma Mass Spectrometry (ICPMS) Analysis of H-Canyon Highly Enriched Uranium Legacy Material at the Savannah River Site (SRS)

The Savannah River National Laboratory (SRNL) uses Inductively Coupled Plasma Mass Spectrometry (ICPMS) to support numerous programs at the Savannah River Site (SRS). As part of an objective to prepare high assay low enriched uranium (HALEU), the SRS H-Canyon needed analysis of legacy uranyl nitrate that is stored at its Outside Facilities (HOF). With the application of a standard practice for alternate actinide calibration on ICP-MS, SRNL has successfully demonstrated its capability to characterize the uranium/actinide composition of the HOF tanks that are intended for consolidation prior to preparation of the HALEU. A comparison of the uranium analytical results between recently upgraded SRNL ICP-MS and Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) instrumentation shows the alternate actinide calibration is a valid complementary method when used in conjunction with other analytical techniques (Davies-Gray Potentiometric Titration). The methods, instrumentation, and ongoing developments on ICP-MS at SRNL will be discussed.

Jones, Mark A.↗

Reactions of U + with H 2 , D 2 , and HD Studied by Guided Ion Beam Tandem Mass Spectrometry and Theory

The kinetic energy-dependent reactions of the atomic actinide uranium cation (U + ) with H 2 , D 2 , and HD were examined by guided ion beam tandem mass spectrometry. An average 0 K bond dissociation energy of D 0 (U + – H) = 2.48 ± 0.06 eV is obtained by analysis of the endothermic product ion cross sections. Quantum chemistry calculations were performed for comparison with experimental thermochemistry, including high-level CASSCF–CASPT2–RASSI calculations of the spin–orbit corrections. CCSD(T) and the CASSCF levels show excellent agreement with experiment, whereas B3LYP and PBE0 slightly overestimate and the M06 approach badly underestimates the bond energy for UH + . Theory was also used to investigate the electronic structures of the reaction intermediates and potential energy surfaces. The experimental product branching ratio for the reaction of U + with HD indicates that these reactions occur primarily via a direct reaction mechanism, despite the presence of a deep-well for UH 2 + formation according to theory. The reactivity and hydride bond energy for U + are compared with those for transition metal, lanthanide, and actinide cations, and periodic trends are discussed. Furthermore, these comparisons suggest that the 5f electrons on uranium are largely core and uninvolved in the reactive chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Strong-field induced fragmentation and isomerization of toluene probed by ultrafast femtosecond electron diffraction and mass spectrometry

We investigate the fragmentation and isomerization of toluene molecules induced by strong-field ionization with a femtosecond near-infrared laser pulse. Momentum-resolved coincidence time-of-flight ion mass spectrometry is used to determine the relative yield of different ionic products and fragmentation channels as a function of laser intensity. Ultrafast electron diffraction is used to capture the structure of the ions formed on a picosecond time scale by comparing the diffraction signal with theoretical predictions. Through the combination of the two measurements and theory, we are able to determine the main fragmentation channels and to distinguish between ions with identical mass but different structures. In addition, our diffraction measurements show that the independent atom model, which is widely used to analyze electron diffraction patterns, is not a good approximation for diffraction from ions. Here, we show that the diffraction data is in very good agreement with ab initio scattering calculations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Detection of Br and I as atomic anions using liquid sampling – atmospheric pressure glow discharge/Orbitrap mass spectrometry

The quantification and determination of halogen isotope composition is essential in many fields including geochemistry and nuclear forensics. Detection of the halogen elements is commonly attempted with inductively coupled plasma mass spectrometry (ICP-MS) however, there are multiple challenges faced. Most significantly this includes very poor ionization efficiency and the potential for isobaric interferences from either matrix or plasma species. Thus, sensitivity and accuracy are often limiting issues. Here a liquid sampling-atmospheric pressure glow discharge (LS-APGD) ionization source is coupled with an ultrahigh resolution Orbitrap MS to perform halogen detection of bromine and iodine as initial analytes. This facilitates simple and sensitive detection of these elements as atomic anions from simple aqueous salt solutions. Collision-induced dissociation (CID) and higher-energy collisional dissociation (HCD) energies were optimized to produce the maximum response of Br − and I − . The LS-APGD conditions were optimized using a design of experiments (DOE) approach for Br − and I − concurrently. Response curves for Br − and I − solutions determined limit of detection (LOD) values of 50 pg and 5 pg, respectively, in 20 μL aliquots. The curves indicated response factors of 0.67 for 79 Br − and 0.90 for 127 I − . Br isotope ratios were determined with precision between 0.7 and 7.3% RSD, with the isotope ratios determined with precision 0.8% RSD at concentrations above the limit of quantification. Preliminary tests were conducted to evaluate the effect of different cations (Na + , K + , and Mg 2+ ) on Br − responses, with no discernible impacts observed on the halogen signal responses. This study demonstrates the potential use of the LS-APGD-Orbitrap-MS for the detection of multiple halogens while avoiding interferences, minimizing sample preparation, and overcoming ionization barriers.

Lang, Dehlia A. [Clemson University, SC (United St↗

Activation of methane by U + studied by guided ion beam tandem mass spectrometry and quantum chemistry

Reaction pathways of all products formed in the U + + CH 4 (CD 4 ) reaction were explored as a function of kinetic energy using guided ion beam tandem mass spectrometry and quantum chemical calculations. UH + , UC + , UCH + , UCH 2 + , and UCH 3 + (and their perdeuterated analogues) are formed in endothermic reactions. In both systems, the UCH 2 + (UCD 2 + ) dehydrogenated product was the dominant product in the low-energy region, whereas the UH + (UD + ) hydride product became predominant at high energies. The kinetic energy behavior of the various products is consistent with a common intermediate of H–U + –CH 3 (D–U + –CD 3 ). Here, the kinetic energy dependence of all product cross sections was modeled to obtain experimental bond dissociation energies at 0 K (in eV): D 0 (U + –H) = 2.42 ± 0.10, D 0 (U + –C) = 3.95 ± 0.12, D 0 (U + –CH) = 4.91 ± 0.09, D 0 (U + –CH 2 ) = 4.11 ± 0.04, and D 0 (U + –CH 3 ) = 2.41 ± 0.09. Quantum chemical calculations using the UCCSD(T) and UB3LYP approaches with the cc-pwCVXZ-PP basis set with MDF-60 pseudopotential for U + and the aug-cc-pCVXZ and aug-cc-pVXZ (X = T, Q) basis set for carbon and hydrogen, respectively, validate the experimental bond dissociation energies and outline the potential energy surface for all reactions observed. In addition, spin–orbit corrections of the bond energies for all products were calculated at a CASSCF-CASPT2-RASSI level.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultra High Performance Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry and Fisher Ratio Analysis for Discovery-Based Analysis

The ability to discover minute differences between samples or sample classes for ultrahigh performance liquid chromatography coupled to quadrupole time-of-flight mass spectrometry (UHPLC-QTOF) can be a challenging endeavor especially when these differences are not known a priori. Indeed a typical UHPLC-QTOF analysis time of ~15 minutes can generate over 4 gigabytes of information for a single sample. Implementation of chemometrics such as Fisher ratio (F-ratio) analysis will allow the analyst to quickly and precise probe the chemical differences between different samples or sample classes. F-ratio analysis can be used to find sample or sample class distinguishing compounds reducing the 5 gigabytes of information into a simple, yet informative hit list. Moreover through combinatorial rearrangement, it is possible to determine a F-ratio threshold to separate the real and non-real hits. The F-ratio software presented herein is a semi-automated algorithm that processes the raw, exported .csv files from the SCIEX 500R QTOF in as little as 30 seconds. While further research is needed to modify and perfect the software to deal with high resolution mass spectra precise to 0.0001 Daltons, the current software, precise to 0.1 Da, is able to find significant chemical differences despite some of them being at extremely low concentrations nearing the limit of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trimethyloxonium-mediated methylation strategies for the rapid and simultaneous analysis of chlorinated phenols in various soils by electron impact gas chromatography–mass spectrometry

Abstract The efficient methylation of a panel of five industrial and environmentally-relevant chlorophenols (CPs) employing trimethyloxonium tetrafluoroborate (TMO) for their qualitative detection and identification by electron impact gas chromatography–mass spectrometry (EI-GC–MS) is presented. The protocol’s execution is simple and smoothly converts the phenols into their O-methylated counterparts conveniently at ambient temperature. The efficiency of two versions of the protocol was successfully tested in their ability to simultaneously derivatize five CPs (2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol and triclosan) in six distinct, separate soil matrices (Nebraska EPA standard soil, Virginia Type A soil, Ottawa sand, Baker sand, Silt and Georgia EPA standard soil) when present at low levels (~ 10 μgg −1 ). The first version involves the direct derivatization of the spiked soils with the methylating salt while the second one involves an initial soil extraction step of the CPs followed by methylation. The MDL values for each methylated CP were determined and lower values were found (4.1–13.2 ng . mL −1 ) for both sand matrices (Ottawa and Baker) as well as for the Georgia EPA standard soil, while larger values (8.2–21.8 ng . mL −1 ) were found for the Virginia Type soil, Nebraska EPA standard soil and Silt. The presented protocol offers a safer and more practical alternative to the universally employed diazomethane method and can be readily applicable to matrices other than soils. Furthermore, the protocols described herein may find applicability to the methylation of other analytes bearing acidic protons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TOFHunter—unlocking rapid untargeted screening of inductively coupled plasma–time-of-flight–mass spectrometry data

This study provides an overview of a newly developed open source program written in Python, TOFHunter, which permits the rapid and untargeted screening of inductively coupled plasma (ICP)-time-of-flight (TOF)-mass spectrometry (MS) datasets. ICP-TOF-MS is an analytical tool capable of providing quasi simultaneous detection of all nuclides from Li to Pu. This capability has triggered an increase in studies investigating single-particle analysis in which the TOF-MS provides correlated elemental/isotopic signatures on a particle basis in time. Similarly, laser ablation mapping has seen rapid growth owing to ICP-TOF-MS's capacity to handle fast washout times (<10 ms) while providing a broad nuclide coverage. The caveat to this broad mass coverage and high time resolution comes in the form of large, overwhelming datasets. With datasets typically on the scale of gigabytes, it is easy for a user to only focus on very targeted analytes; however, this focus diminishes the opportunity offered by the TOF-MS detector. TOFHunter applies chemometric methods, principal component analysis (PCA), and interesting features finder (IFF) on ICP-TOF-MS data, allowing for investigation of correlations, major and minor variance sources, and sample screening. The unique spectra identified by the (IFF) are used to generate a list of mass peaks, which are then matched with both nuclides and potential interferences before being exported for the user to investigate. Several case studies are discussed herein, demonstrating TOFHunter's ability to screen aqueous injections, single-particle/single-cell analysis, and probe laser ablation mapping files for unique regions of interest.

47 OTHER INSTRUMENTATION↗

Evaluation of the accuracy of stopping and range of ions in matter simulations through secondary ion mass spectrometry and Rutherford backscattering spectrometry for low energy heavy ion implantation

The freely available “Stopping and Range of Ions in Matter” (SRIM) code is used for evaluating ion beam ranges and depth profiles. We present secondary ion mass spectrometry and Rutherford backscattering experimental results of Si samples implanted with low energy Sb ions to evaluate the accuracy of SRIM simulations. We show that the SRIM simulation systematically overestimates the range by 2–6 nm and this overestimation increases for larger ion implantation energy. For the lowest energy implantation investigated, here we find up to a 25% error between the SRIM simulation and the measured range. Finally, the ion straggle shows excellent agreement between simulation and experimental results.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Discrimination between individual dust and bioparticles using aerosol time-of-flight mass spectrometry

Ice nucleating particles (INPs) impact cloud properties and precipitation processes through their ability to trigger cloud glaciation. Dust and bioparticles are two important sources of INPs that have markedly different atmospheric loadings and ice nucleating efficiencies. In situ identification of the sources of INPs in clouds has been accomplished using single particle mass spectrometry (SPMS). However, external mixtures of dust and bioparticles present a unique challenge as they have overlapping mass spectral ion signatures, complicating their unambiguous identification. This study presents a detailed discussion of dust and bioparticle SPMS signatures, uniting data from a broad array of studies. As emphasized, the ion signals from both dust and bioparticles are highly sensitive to ionization conditions. To understand the observed variations, we characterize the mass spectral dependence of distinct dust and bioparticle samples using total positive ion intensity (TPII) as an indicator of the laser pulse energy each particle encountered. Through this analysis, a broad range of characteristic biogenic low intensity ion peaks that may be useful to distinguish bioparticles from dust became apparent and are highlighted. Insights informed by this analysis were utilized to identify bioparticles in ambient SPMS data. Ambient particles exhibiting both dust and characteristic biogenic spectral fingerprints were excluded from the bioparticle classification. Although bioparticles only made up 0.2% of all sampled particles, their abundance was moderately correlated with INP concentrations measured at 15 °C.

54 ENVIRONMENTAL SCIENCES↗

Calcium fluoride as a dominating matrix for quantitative analysis by laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS): A feasibility study

Here, calcium fluoride formed by the reaction between ammonium bifluoride and calcium chloride was investigated as a dominating matrix for quantitative analysis by laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). Transformation from a solid sample to the calcium fluoride-based matrix permitted quantitative analysis based on calibration standards made from elemental standards. A low abundance stable calcium isotope, i.e. 44 Ca + , was monitored as the internal standard for quantitative analysis by LA-ICP-MS. Correlation coefficient factors for multiple elements were obtained with values over 0.999. The results for multiple elements in a certified reference material of soil (NIST SRM 2710a) agreed with the certified values in the range of expanded uncertainty, indicating the present method was valid for quantitation of elements in solid samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Uranium Single Particle Analysis for Simultaneous Fluorine and Uranium Isotopic Determinations via Laser-Induced Breakdown Spectroscopy/Laser Ablation–Multicollector–Inductively Coupled Plasma–Mass Spectrometry

Uranyl fluoride (UO 2 F 2 ) particles (<20 μm) were subjected to first-of-its-kind analysis via simultaneous laser-induced breakdown spectroscopy (LIBS) and laser ablation multi-collector inductively coupled plasma–mass spectrometry (LA–MC–ICP–MS). Briefly, a nanosecond pulsed high-energy laser was focused onto the sample (particle) surface. In a single laser pulse, the UO 2 F 2 particle was excited/ionized within the microplasma volume, and the emission of light was collected via fiber optics such that emission spectroscopy could be employed for the detection of uranium (U) and fluorine (F). The ablated particle was simultaneously transported into the MC–ICP–MS for high precision isotopic (i.e., 234 U, 235 U, and 238 U) analysis. This method, LIBS/LA–MC–ICP–MS was optimized and employed to rapidly measure 80+ UO 2 F 2 particles, which were subjected to different calcination processes, which results in varying degrees of F loss from the individual particles. In measuring the particles, the average F/U ratios for the populations treated at 100 and 500 °C were 2.78 ± 1.28 and 1.01 ± 0.50, respectively, confirming loss of F through the calcination process. The average 235 U/ 238 U on the particle populations for the 100 and 500 °C were 0.007262 (22) and 0.007231 (23), which was determined to be <0.2% from the expected value. The 234 U/ 238 U ratios on the same particles were 0.000053 (11) and 0.000050 (10) for the 100 and 500 °C, respectively, <10% from the expected value. Notably, each population was analyzed in under 5 min, demonstrating the truly rapid analysis technique presented here in this paper.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗