Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Magnetic Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Large, high resolution integrating TV sensor for astronomical appliations

A magnetically focused SEC tube developed for photometric applications is described. Efforts to design a 70 mm version of the tube which meets the ST f/24 camera requirements of the space telescope are discussed. The photometric accuracy of the 70 mm tube is executed to equal that of the previously developed 35 mm tube. The tube meets the criterion of 50 percent response at 20 cycles/mm in the central region of the format, and, with the removal of the remaining magnetic parts, this spatial frequency is expected over almost all of the format. Since the ST f/24 camera requires sensitivity in the red as well as the ultraviolet and visible spectra, attempts were made to develop tubes with this ability. It was found that it may be necessary to choose between red and u.v. sensitivity and tradeoff red sensitivity for low background. Results of environmental tests indicate no substantive problems in utilizing it in a flight camera system that will meet the space shuttle launch requirements.

Spitzer, L. J.↗

Characterization of Losses in Superconducting Radio-Frequency Cavities by Combined Temperature and Magnetic Field Mapping

Superconducting radio-frequency (SRF) cavities are one of the fundamental building blocks of modern particle accelerators. To achieve the highest quality factors (10 10 -10 11 ), SRF cavities are operated at liquid helium temperatures. Magnetic flux trapped on the surface of SRF cavities during cool-down below the critical temperature is one of the leading sources of residual RF losses. Instruments capable of detecting the distribution of trapped flux on the cavity surface are in high demand in order to better understand its relation to the cavity material, surface treatments and environmental conditions. We have designed, developed, and commissioned two novel diagnostic tools to measure the distribution of trapped flux at the surface of SRF cavities. One is a magnetic field scanning system (MFSS) which uses cryogenic Hall probes and anisotropic magnetoresistance sensors that fit the contour of a 1.3 GHz cavity. The second setup is a stationary, combined magnetic and temperature mapping system which uses AMR sensors and carbon resistor temperature sensors, covering the surface of a 3 GHz SRF cavity. The MFSS system revealed a non-uniform distribution of trapped flux on the cavities' surface, dependent on the magnitude of the applied magnetic field during field-cooling below the critical temperature. The MFSS shows that magnetic field scanning as a function of the RF field indicates redistribution of trapped flux at some locations. About ~ 33% of hot-spots observed by temperature mapping during high power RF tests overlapped with the high B-field spots. Almost all high B-field spots observed after field-cool were found to be overlapped on grain boundaries. A clear correlation between the hot- spot formed after quench and local trapped flux was found, providing insight on the RF dissipation of trap vortices. The combined B&T map system showed that the T-map system is capable of detecting hot-spots and quench location on the surface of the 3 GHz SRF cavity. Different distribution of trapped flux was measured after different cool-down and residual B-field, but, no variation in magnetic field distribution was observed during quench, possibly due to magnetic sensors being far from the quench location.

Parajuli, Ishwari↗

Magnetostrictive materials for enhanced sensors and electronic components

Magnetostriction is a property of magnetic materials that causes them to change their shape or dimensions when their magnetization changes. Low-cost, mechanically robust magnetostrictive sensors would be valuable for a wide range of applications addressing DOE's energy, environmental, and national security missions. Several examples include monitoring internal conditions of pipelines, enhancing implantable systems for the human body, and improving the electrical grid by providing real time sensors for detecting high impedance faults that may act as ignition sources for forest fires. Historically, magnetostrictive materials tended to be expensive and mechanically brittle, but recent developments in iron-based alloys, especially those that include dilute solutions of rare earth elements, have demonstrated useful magnetostriction values, mechanical robustness, and low costs. This project investigated addition of dilute cerium doping on the magnetostrictive properties of Fe-Ga and Fe-Al alloys. Advanced manufacturing techniques were applied to these materials to take advantage of rapid cooling of the alloy to stabilize desired phases and to make near net shape coupons. These coupons develop significant texturing, offering a route to target microstructures with exceptional performance.

36 MATERIALS SCIENCE↗

Preliminary GN&C Design for the On-Orbit Autonomous Assembly of Nanosatellite Demonstration Mission

Small spacecraft autonomous rendezvous and docking (ARD) is an essential technology for future space structure assembly missions. The On-orbit Autonomous Assembly of Nanosatellites (OAAN) team at NASA Langley Research Center (LaRC) intends to demonstrate the technology to autonomously dock two nanosatellites to form an integrated system. The team has developed a novel magnetic capture and latching mechanism that allows for docking of two CubeSats without precise sensors and actuators. The proposed magnetic docking hardware not only provides the means to latch the CubeSats, but it also significantly increases the likelihood of successful docking in the presence of relative attitude and position errors. The simplicity of the design allows it to be implemented on many CubeSat rendezvous missions. Prior to demonstrating the docking subsystem capabilities on orbit, the GN&C subsystem should have a robust design such that it is capable of bringing the CubeSats from an arbitrary initial separation distance of as many as a few thousand kilometers down to a few meters. The main OAAN Mission can be separated into the following phases: 1) Launch, checkout, and drift, 2) Far-Field Rendezvous or Drift Recovery, 3) Proximity Operations, 4) Docking. This paper discusses the preliminary GN&C design and simulation results for each phase of the mission.

Pei, Jing↗

Relativistic Electron Response to the Combined Magnetospheric Impact of a Coronal Mass Ejection Overlapping with a High-Speed Stream: Van Allen Probes Observations

During early November 2013, the magnetosphere experienced concurrent driving by a coronal mass ejection (CME) during an ongoing high-speed stream (HSS) event. The relativistic electron response to these two kinds of drivers, i.e., HSS and CME, is typically different, with the former often leading to a slower buildup of electrons at larger radial distances, while the latter energizing electrons rapidly with flux enhancements occurring closer to the Earth. We present a detailed analysis of the relativistic electron response including radial profiles of phase space density as observed by both Magnetic Electron and Ion Sensor (MagEIS) and Relativistic Electron Proton Telescope instruments on the Van Allen Probes mission. Data from the MagEIS instrument establish the behavior of lower energy (<1 MeV) electrons which span both intermediary and seed populations during electron energization. Measurements characterizing the plasma waves and magnetospheric electric and magnetic fields during this period are obtained by the Electric and Magnetic Field Instrument Suite and Integrated Science instrument on board Van Allen Probes, Search Coil Magnetometer and Flux Gate Magnetometer instruments on board Time History of Events and Macroscale Interactions during Substorms, and the low-altitude Polar-orbiting Operational Environmental Satellites. These observations suggest that during this time period, both radial transport and local in situ processes are involved in the energization of electrons. The energization attributable to radial diffusion is most clearly evident for the lower energy (<1 MeV) electrons, while the effects of in situ energization by interaction of chorus waves are prominent in the higher-energy electrons.

Magnetosphere↗

IDENTIFICATION OF POTENTIAL SUPERCONDUCTOR QUENCH PRECURSORS USING FREQUENCY DOMAIN FEATURE ANALYSIS

Superconducting magnets are important pieces of technology in the world of particle accelerators, allowing researchers to study atomic and subatomic phenomena, among other things. In some instances, superconductors can lose this non-resistive property in a phenomenon known as quenching, which can cause damage to the magnets. This potential danger prompts the introduction of systems to predict when a quench is imminent; one such implementation is through the use of acoustic sensors that detect vibrations within the magnet. Within these acoustic sensor signals, significantly above-noise disturbances (referred to as ”events”) can be identified. Our research applies the statistical framework of a permutation test to features calculated from the power spectral density (PSD) to distinguish between events far from the quench at the end of the signal to events at the start of the signal. We found that dividing the PSD into frequency bands produced a feature capable of distinguishing between events early in the signal and late in the signal leading up the quench, providing a promising starting place for future quench prediction systems.

Roehrig, Benjamin [Northern Illinois U.]↗

Surface structures of magnetostrictive D0 3 -Fe 3 Ga(0 0 1)

First-principles total energy calculations and scanning tunneling microscopy experiments were performed to study the surface reconstruction of the magnetostrictive Fe 3 Ga alloy. The inverse magnetostrictive behavior was evaluated in the bulk by compressing and stretching its lattice parameter, showing an increase in magnetic moments as strain increases. Surface analysis demonstrates two thermodynamically stable surfaces, the (1 × 1) and (3 × 1). The (1 × 1) is an ideal FeGa terminated surface, whereas the (3 × 1) is also FeGa terminated but it has a first-layer Fe atom substituted by a Ga atom every three unit-cells, forming a row-like surface structure. Tersoff–Hamann scanning tunneling microscopy simulations were obtained and compared with experimental results. We found good agreement between theory and experiment, in which the distance between rows is ~12.3 Å. Theoretical findings suggest that the substrate-induced strain may increase the stability of the (3 × 1) reconstruction. Analysis of the magnetic moments in the reconstructions showed that their behavior is affected by a surface effect, as well as by the inverse magnetostriction of the structure. A good understanding of the FeGa surface reconstructions is an important step towards further improvements in magnetic storage devices and sensors.

36 MATERIALS SCIENCE↗

Attitude measurement: Principles and sensors

Tools used in the measurement of satellite attitude are described. Attention is given to the elements that characterize an attitude sensor, the references employed (stars, moon, Sun, Earth, magnetic fields, etc.), and the detectors (optical, magnetic, and inertial). Several examples of attitude sensors are described, including sun sensors, star sensors, earth sensors, triaxial magnetometers, and gyrometers. Finally, sensor combinations that make it possible to determine a complete attitude are considered; the SPOT attitude measurement system and a combined CCD star sensor-gyrometer system are discussed.

Duchon, P.↗

Design, development, and field demonstration of a remotely deployable water quality monitoring system

A prototype water quality monitoring system is described which offers almost continuous in situ monitoring. The two-man portable system features: (1) a microprocessor controlled central processing unit which allows preprogrammed sampling schedules and reprogramming in situ; (2) a subsurface unit for multiple depth capability and security from vandalism; (3) an acoustic data link for communications between the subsurface unit and the surface control unit; (4) eight water quality parameter sensors; (5) a nonvolatile magnetic bubble memory which prevents data loss in the event of power interruption; (6) a rechargeable power supply sufficient for 2 weeks of unattended operation; (7) a water sampler which can collect samples for laboratory analysis; (8) data output in direct engineering units on printed tape or through a computer compatible link; (9) internal electronic calibration eliminating external sensor adjustment; and (10) acoustic location and recovery systems. Data obtained in Saginaw Bay, Lake Huron are tabulated.

Wallace, J. W.↗

Ground Demonstration on the Autonomous Docking of Two 3U CubeSats Using a Novel Permanent-Magnet Docking Mechanism

Small spacecraft autonomous rendezvous and docking is an essential technology for future space structure assembly missions. A novel magnetic capture and latching mechanism is analyzed that allows for docking of two CubeSats without precise sensors and actuators. The proposed magnetic docking hardware not only provides the means to latch the CubeSats but it also significantly increases the likelihood of successful docking in the presence of relative attitude and position errors. The simplicity of the design allows it to be implemented on many CubeSat rendezvous missions. A CubeSat 3-DOF ground demonstration effort is on-going at NASA Langley Research Center that enables hardware-in-the loop testing of the autonomous approach and docking of a follower CubeSat to an identical leader CubeSat. The test setup consists of a 3 meter by 4 meter granite table and two nearly frictionless air bearing systems that support the two CubeSats. Four cold-gas on-off thrusters are used to translate the follower towards the leader, while a single reaction wheel is used to control the attitude of each CubeSat. An innovative modified pseudo inverse control allocation scheme was developed to address interactions between control effectors. The docking procedure requires relatively high actuator precision, a novel minimal impulse bit mitigation algorithm was developed to minimize the undesirable deadzone effects of the thrusters. Simulation of the ground demonstration shows that the Guidance, Navigation, and Control system along with the docking subsystem leads to successful docking under 3-sigma dispersions for all key system parameters. Extensive simulation and ground testing will provide sufficient confidence that the proposed docking mechanism along with the choosen suite of sensors and actuators will perform successful docking in the space environment.

Pei, Jing↗

Flex-PCB Quench Antenna Developments at FNAL

We report flexible printed-circuit-board-based quench antenna arrays have been developed at FNAL since 2017. They proved to be low-noise, low-cost, sensitive, and non-invasive sensors for quench characterization in superconducting magnets, having the potential to extend even to quench detection. Starting with applications of small area sensors of this type, we have explored feasibility for operations at high pressure, and have invested in multi-channel quench antenna arrays covering the complete area of the innermost magnet layer of the conductor. We've also tested and optimized sensor geometry and relative orientations to increase sensitivity and spatial resolution. Beyond developments of warm and cold bore antennas, we've progressed to concepts which attach quench antennas to the conductor surfaces of accelerator magnets. Multiple programs and projects at FNAL and collaborating institutions benefited from this work already and our plans target further extensions of capabilities and applicability of these devices. In this paper we present the logic behind the development steps taken so far, status of our work and direction of near-term research on quench antennas at Fermilab.

43 PARTICLE ACCELERATORS↗

An Overview of Magnetic Bearing Technology for Gas Turbine Engines

The idea of the magnetic bearing and its use in exotic applications has been conceptualized for many years, over a century, in fact. Patented, passive systems using permanent magnets date back over 150 years. More recently, scientists of the 1930s began investigating active systems using electromagnets for high-speed ultracentrifuges. However, passive magnetic bearings are physically unstable and active systems only provide proper stiffness and damping through sophisticated controllers and algorithms. This is precisely why, until the last decade, magnetic bearings did not become a practical alternative to rolling element bearings. Today, magnetic bearing technology has become viable because of advances in micro-processing controllers that allow for confident and robust active control. Further advances in the following areas: rotor and stator materials and designs which maximize flux, minimize energy losses, and minimize stress limitations; wire materials and coatings for high temperature operation; high-speed micro processing for advanced controller designs and extremely robust capabilities; back-up bearing technology for providing a viable touchdown surface; and precision sensor technology; have put magnetic bearings on the forefront of advanced, lubrication free support systems. This paper will discuss a specific joint program for the advancement of gas turbine engines and how it implies the vitality of magnetic bearings, a brief comparison between magnetic bearings and other bearing technologies in both their advantages and limitations, and an examination of foreseeable solutions to historically perceived limitations to magnetic bearing.

Clark, Daniel J.↗

Novel 3D Force Sensors for a Cost-Effective 3D Force Plate for Biomechanical Analysis

Three-dimensional force plates are important tools for biomechanics discovery and sports performance practice. However, currently, available 3D force plates lack portability and are often cost-prohibitive. To address this, a recently discovered 3D force sensor technology was used in the fabrication of a prototype force plate. Thirteen participants performed bodyweight and weighted lunges and squats on the prototype force plate and a standard 3D force plate positioned in series to compare forces measured by both force plates and validate the technology. For the lunges, there was excellent agreement between the experimental force plate and the standard force plate in the X-, Y-, and Z-axes (r = 0.950–0.999, p < 0.001). For the squats, there was excellent agreement between the force plates in the Z-axis (r = 0.996, p < 0.001). Across axes and movements, root mean square error (RMSE) ranged from 1.17% to 5.36% between force plates. Although the current prototype force plate is limited in sampling rate, the low RMSEs and extremely high agreement in peak forces provide confidence the novel force sensors have utility in constructing cost-effective and versatile use-case 3D force plates.

42 ENGINEERING↗

Non-volatile magnetic random access memory

Improvements are made in a non-volatile magnetic random access memory. Such a memory is comprised of an array of unit cells, each having a Hall-effect sensor and a thin-film magnetic element made of material having an in-plane, uniaxial anisotropy and in-plane, bipolar remanent magnetization states. The Hall-effect sensor is made more sensitive by using a 1 m thick molecular beam epitaxy grown InAs layer on a silicon substrate by employing a GaAs/AlGaAs/InAlAs superlattice buffering layer. One improvement avoids current shunting problems of matrix architecture. Another improvement reduces the required magnetizing current for the micromagnets. Another improvement relates to the use of GaAs technology wherein high electron-mobility GaAs MESFETs provide faster switching times. Still another improvement relates to a method for configuring the invention as a three-dimensional random access memory.

Katti, Romney R.↗

Performance Evaluation Modeling of Network Sensors

Substantial benefits are promised by operating many spatially separated sensors collectively. Such systems are envisioned to consist of sensor nodes that are connected by a communications network. A simulation tool is being developed to evaluate the performance of networked sensor systems, incorporating such metrics as target detection probabilities, false alarms rates, and classification confusion probabilities. The tool will be used to determine configuration impacts associated with such aspects as spatial laydown, and mixture of different types of sensors (acoustic, seismic, imaging, magnetic, RF, etc.), and fusion architecture. The QualNet discrete-event simulation environment serves as the underlying basis for model development and execution. This platform is recognized for its capabilities in efficiently simulating networking among mobile entities that communicate via wireless media. We are extending QualNet's communications modeling constructs to capture the sensing aspects of multi-target sensing (analogous to multiple access communications), unimodal multi-sensing (broadcast), and multi-modal sensing (multiple channels and correlated transmissions). Methods are also being developed for modeling the sensor signal sources (transmitters), signal propagation through the media, and sensors (receivers) that are consistent with the discrete event paradigm needed for performance determination of sensor network systems. This work is supported under the Microsensors Technical Area of the Army Research Laboratory (ARL) Advanced Sensors Collaborative Technology Alliance.

probability of detection↗

Galfenol Tactile Sensor Array and Visual Mapping System

The smart material, Galfenol, is being explored for its uses as a magnetostrictive material. This project seeks to determine if Galfenol can be used as a tactile sensor in a 2-D grid array, magnetic circuit system. When used within a magnetic circuit, Galfenol indicates induced stress and force as a change in flux, due to a change in permeability of the material. The change in flux is detected by Giant MagnetoResistive (GMR) Sensors, which produce a voltage change proportional to the field change. By using Galfenol in an array, this research attempts to create a sensory area. Galfenol is an alloy made of Iron and Gallium. FexGax, where 15 less than or equal to x less than or equal to 28, creates a material with useful mechanical and transduction attributes (Clark et al and Kell). Galfenol is also distinguished by the crystalline structure of the material. Two types currently exist: single crystal and polycrystalline. Single crystal has higher transduction coefficients than polycrystalline, but is more costly. Polycrystalline Galfenol is currently available as either production or research grade. The designations are related to the sample growth rate with the slower rate being the research grade. The slower growth rate more closely resembles the single crystal Galfenol properties. Galfenol 17.5- 18% research grade is used for this experiment, provided by Etrema Products Inc. The magnetic circuit and sensor array is first built at the macro scale so that the design can be verified. After the macro scale is proven, further development will move the system to the nano-level. Recent advances in nanofabrication have enabled Galfenol to be grown as nanowires. Using the nanowires, research will seek to create high resolution tactile sensors with spatial resolutions similar to human finger tips, but with greater force ranges and sensitivity capabilities (Flatau & Stadler). Possible uses of such systems include robotics and prosthetics.

Hale, Kathleen↗

Low Current Magnet

Because Goddard Space Flight Center needed a way to cool sensors aboard the AXAF, a low current superconducting magnet was developed under contract by Cryomagnetics, Inc. The magnet, now commercially available, reduced the rate of helium consumption, extending the lifetime of the AXAF's x-ray spectrometer. On Earth, it offers a way to reduce operating costs through smaller, less expensive power supplies and reduced use of coolant. The magnet has particular advantages for MRI systems, as it is safer and has lower maintenance requirements.

Source record↗