At least 289 records · Page 16

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SEM/EBSD Characterization of Baffle-Former Bolts Designated for High Energy X-ray Microscopy Studies at the Advanced Photon Source

This report documents the microstructural and surface characterization of two high-fluence baffle-former bolts (BFBs) harvested from a commercial pressurized water reactor (PWR) after nearly four decades of service. These bolts experienced extreme conditions including high neutron fluence, elevated temperatures, corrosive primary water, and sustained mechanical loads, all of which contribute to degradation mechanisms such as irradiation-assisted stress corrosion cracking (IASCC). Using scanning electron microscopy (SEM) and electron backscatter diffraction (EBSD), the study assessed bulk and near-surface microstructures, grain boundary characteristics, and in-service oxide layers. The results revealed significant differences between bolts exposed to 41 dpa and 29 dpa, including differences in recrystallization extent, deformation structures, and oxidation morphology. These findings establish critical baseline data for integration with advanced synchrotron-based high-energy X-ray microscopy (HEXM) and computational crystal plasticity models. Ultimately, the work supports improved mechanistic understanding and predictive capability regarding the long-term performance of reactor core internal components.

Lach, Tim [Oak Ridge National Laboratory (ORNL), O↗

High-Resolution Transmission Electron Microscopy Study of a Powder River Basin Coal-Derived Fly Ash

Examination of a fly ash derived from the combustion of a low-S, subbituminous Powder River Basin coal by Scanning Electron Microscopy (SEM) and High-resolution Transmission Electron Microscopy (HRTEM), both supplemented by Energy-dispersive X-ray spectroscopy (EDS), showed that the fly ashes were dominated by amorphous phases, Ca-rich plagioclase feldspars, Mg-rich phases, complex Ca-Mg-Al-Si-Ti-Fe grains, and trace amounts of REE-rich particles. Many of the particles were rimmed by a Ca-S, possibly a sulfate. HRTEM-EDS examination of a REE-rich particle proved it to be a mix of light- and heavy-rare earth minerals mixed with amorphous phases.

58 GEOSCIENCES↗

Optimizing Magnetic Force Microscopy Resolution and Sensitivity to Visualize Nanoscale Magnetic Domains

Magnetic force microscopy (MFM) enables mapping local magnetic fields across a sample surface with nanoscale resolution. To perform MFM, an atomic force microscopy (AFM) probe whose tip has been magnetized vertically (i.e., perpendicular to the probe cantilever) is oscillated at a fixed height above the sample surface. The resultant shifts in the oscillation phase or frequency, which are proportional to the magnitude and sign of the vertical magnetic force gradient at each pixel location, are then tracked and mapped. Although the spatial resolution and sensitivity of the technique increases with decreasing lift height above the surface, this seemingly straightforward path to improved MFM images is complicated by considerations such as minimizing topographical artifacts due to shorter range van der Waals forces, increasing the oscillation amplitude to further improve sensitivity, and the presence of surface contaminants (in particular water due to humidity under ambient conditions). In addition, due to the orientation of the probe's magnetic dipole moment, MFM is intrinsically more sensitive to samples with an out-of-plane magnetization vector. Here, high-resolution topographical and magnetic phase images of single and bicomponent nanomagnet artificial spin-ice (ASI) arrays obtained in an inert (argon) atmosphere glovebox with <0.1 ppm O 2 and H 2 O are reported. Further, optimization of lift height and drive amplitude for high resolution and sensitivity while simultaneously avoiding the introduction of topographical artifacts is discussed, and detection of the stray magnetic fields emanating from either end of the nanoscale bar magnets (~250 nm long and <100 nm wide) aligned in the plane of the ASI sample surface is shown. Likewise, using the example of a Ni-Mn-Ga magnetic shape memory alloy (MSMA), MFM is demonstrated in an inert atmosphere with magnetic phase sensitivity capable of resolving a series of adjacent magnetic domains each ~200 nm wide.

47 OTHER INSTRUMENTATION↗

State-of-the-Art Electron Microscopy For Physical Sciences Research

The ability to provide high-resolution information about a variety of materials has made electron microscopy a valuable tool for the physical sciences research community. In recent years, many advanced electron microscopy techniques have been developed to provide access to new classes of materials or provide new types of information about materials. This Methods Collection focuses on a selection of these state-of-the-art techniques, including those that provide access to information about materials in liquids and gases and those that provide new or enhanced information about more conventional solid materials.

47 OTHER INSTRUMENTATION↗

Helium Ion Microscopy

Nanotechnology research led to the development of various instruments to be used for imaging or fabrication. The helium ion microscope (HIM) became available in 2006 but quickly gained popularity. Its unique gas field ion source enables high-resolution imaging, nanofabrication, direct write, and the recent combination with a secondary ion mass spectrometer offers chemical imaging with ~15 nm resolution. Particularly attractive are the small interaction volume of He and Ne (the two gases offered), small beam spot size, and a moderate sputtering rate. Additionally, the HIM is an excellent imaging tool for insulating samples in soft, polymeric, and biological materials. It can be expected that helium ion microscopy will continue to have a strong influence on broad range of scientific disciplines, including chemistry, materials science, and biology.This chapter aims at providing an overview of the current status of HIM for imaging, analysis, and nanofabrication. It introduces the reader to key components of the instrument, theoretical background, and latest results in the areas of imaging, material fabrication, and chemical analysis capabilities of helium ion microscopy.

Belianinov, Alex↗

A three-dimensional reconstruction algorithm for scanning transmission electron microscopy data from thick samples

Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data and transcends the prevalent structure retrieval algorithm assumption of a very thin specimen homogenous along the optic axis. We demonstrate this approach by reconstructing the different layers of a lead iridate (Pb$_2$Ir$_2$O$_7$) and yttrium-stabilized zirconia (Y$_{0.095}$Zr$_{0.905}$O$_2$) heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction.

Brown, Hamish G↗

Recent advances in nano-scale spatial resolution x-ray microscopy instrumentation at NSLS-II

X-ray microscopy is an invaluable and powerful characterization tool applied in many scientific fields, such as materials science, biology, environmental science, and energy research. In recent years it has been driven by rapid developments of novel technologies and systems resulting in imaging experiments elucidating structural inhomogeneities and chemical reactions at the nanometer scale. To obtain high spatial resolution comprehensive chemical and structural information, an X-ray microscope must be equipped with adequate capabilities and allow for simultaneous acquisition of multiple datasets. In recent years, a number of X-ray microscopes have been designed, constructed, and commissioned at NSLS-II. Here we provide an overview of the microscopy instrumentation development program at NSLS-II and specifically focus on the multilayer Laue lens-based hard X-ray nanoprobe optimized for ~10 nm spatial resolution imaging, its current status, and future upgrades along with recently constructed Kirkpatrick-Baez based scanning microscope designed for ~100 nm spatial resolution experiments.

36 MATERIALS SCIENCE↗

Dark field X-ray microscopy below liquid-helium temperature: The case of NaMnO 2

Dark field X-ray microscopy (DFXM) is an experimental technique employed to investigate material properties by probing their ‘mesoscale,’ or microscale structures, in a bulk-sensitive manner using hard X-rays at synchrotron radiation sources. However, challenges remain when it comes to applications of this technique to examine low-temperature phenomena in quantum materials, which exhibit complex phase transitions at cryogenic temperatures. One such material is NaMnO 2 , which hosts an antiferromagnetic transition at 45 K that is suspected to coincide with local structural transitions from its majority monoclinic phase to nanoscale triclinic domains. Direct observation of local heterogeneities and this effect at low temperatures in NaMnO 2 is an important step in understanding this material and serves as an ideal candidate study for expanding the DFXM experimental design space. This paper details a foundational high-resolution DFXM study, down to liquid-helium temperature and below, conducted to explore phase transitions in NaMnO 2 . In conclusion, the outlined experiment ushers in the evaluation of other functional materials at low temperatures using this technique.

36 MATERIALS SCIENCE↗

Advancing conventional High-Resolution Electron Microscopy

Due to the exceptional performance of most modern commercial transmission electron microscopes, the achievement of phase-contrast imaging resolution in the sub-2Å range is today a routine exercise, provided the samples are compliant. Nonetheless, there remains room for improvement, and the purpose of this manuscript is to highlight procedures that might be employed by the practicing microscopist for advancing conventional high resolution electron microscopy.

440800* -- Miscellaneous Instrumentation-- (1990-)↗

High-Resolution Full-Field Structural Microscopy of the Voltage-Induced Filament Formation in VO 2 -Based Neuromorphic Devices

In order to make neuromorphic functions in memristive devices more efficient, information about the structural properties of filament formation at the micro- and mesoscopic scales is necessary. Despite extensive research on VO 2 , a key material due to its filament formation, local operando structural measurements remain challenging and often involve destructive specimen preparation and long rastering times, greatly limiting the scope of experimental studies. Utilizing dark-field X-ray microscopy (DFXM), a fullfield imaging modality, structural signatures of the filament formation process operando are revealed in VO 2 devices. DFXM experiments illustrate that rutile filaments contain isolated monoclinic clusters, indicating structural nonuniformity interior to the filament. The formation of the rutile phase beneath device electrodes was shown to precede filament development, followed by the formation of filament paths guided by nucleation sites within the device. Finally, a medium-term (<30 min) memory mechanism is observed in VO 2 , mediated by sites within the device gap that tend to switch at significantly lower voltages after electrical cycling, a tendency that persists through a brief thermal reset. High spatial resolution, large field-of-view, structure selectivity, and fast signal acquisition of DFXM provided insight into structural features of the filamentary channel and surrounding regions during voltage cycling.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Advancing Cross-Sectional Scanning Electron Microscopy of Perovskite Solar Cells

Organic–inorganic perovskites are an emerging class of photovoltaic materials. Despite achieving power conversion efficiencies surpassing 26%, the challenge of perovskite stability including degradation during exposure to operational conditions such as light, heat, humidity, water, oxygen, and electric fields is well known. Related, perovskite instability has limited high-resolution electron imaging and characterization techniques that can be used for understanding degradation mechanisms. Furthermore, we demonstrate perovskite device cross-section preparation using mechanical polishing in a water-free environment with cryogenic Ar ion milling. Scanning electron microscopy was then used in both backscattered electron and secondary electron imaging modes to obtain information about layer structure, grain aggregate structure, and compositional heterogeneity. Monte Carlo CASINO simulations inform optimum beam conditions and image acquisition parameters and the effects of accelerating voltage, dwell times, and frame averaging for practical image acquisition are reported.

14 SOLAR ENERGY↗

Contribution of advanced fluorescence nano microscopy towards revealing mitotic chromosome structure

The organization of chromatin into higherorder structures and its condensation process represent one of the key challenges in structural biology. This is important for elucidating several disease states. To address this long-standing problem, development of advanced imaging methods has played an essential role in providing understanding into mitotic chromosome structure and compaction. Amongst these are two fast evolving fluorescence imaging technologies, specifically fluorescence lifetime imaging (FLIM) and superresolution microscopy (SRM). FLIM in particular has been lacking in the application of chromosome research while SRM has been successfully applied although not widely. Furthermore, both these techniques are capable of providing fluorescence imaging with nanometer information. SRM or "nanoscopy" is capable of generating images of DNA with less than 50 nm resolution while FLIM when coupled with energy transfer may provide less than 20 nm information. Here, we discuss the advantages and limitations of both methods followed by their contribution to mitotic chromosome studies. Furthermore, we highlight the future prospects of how advancements in new technologies can contribute in the field of chromosome science.

59 BASIC BIOLOGICAL SCIENCES↗

Denoising atomic resolution 4D scanning transmission electron microscopy data with tensor singular value decomposition

Tensor singular value decomposition (SVD) is a method to find a low-dimensional representation of data with meaningful structure in three or more dimensions. Here, tensor SVD has been applied to denoise atomic-resolution 4D scanning transmission electron microscopy (4D STEM) data. On data simulated from a SrTiO 3 [100] perfect crystal and a Si [110] edge dislocation, tensor SVD achieved an average peak signal-to-noise ratio (PSNR) of ~40 dB, which matches or exceeds the performance of other denoising methods, with processing times at least 100 times shorter. On experimental data from SrTiO 3 [100] and LiZnSb [11 2 ¯ 0]/GaSb [110] samples, tensor SVD denoises multiple GB 4D STEM data sets in ten minutes on a typical personal computer. Denoising with tensor SVD improves both convergent beam electron diffraction patterns and virtual-aperture annular dark field images.

36 MATERIALS SCIENCE↗

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

Probing Activities of Individual Catalytic Nanoflakes by Tunneling Mode of Scanning Electrochemical Microscopy

The tunneling mode of scanning electrochemical microscopy (SECM) was developed recently and applied to studies of charge-transfer reactions at single metal nanoparticles (NPs). When an SECM tip is brought within the tunneling distance from a conductive NP, the particle begins to act as a part of the nanoelectrode. Herein, we demonstrate the possibility of using carbon nanoelectrodes with a very thin insulating sheath for electrochemical tunneling experiments at flat samples. In this way, electrocatalytic activity, conductivity, and charging properties of and faradaic processes in layered nanomaterials can be characterized by single-nanoflake voltammetry without making direct ohmic contact with them. A broad applicability of tunneling SECM experiments is demonstrated by probing nanomaterials with different size, geometry, and electrocatalytic properties, including metallic/pseudo-metallic (1T/1T') and semiconducting (2H) MoS 2 nanoflakes, N-doped porous carbon catalyst, and MXene nanosheets. Further, the Tafel plots for the hydrogen evolution reaction (HER) and oxygen evolution reaction (OER) at individual nanoflakes are compared to analogous measurements for an ensemble of flakes attached to the surface of a macroscopic electrode. Moreover, we observed variations in catalytic activities of individual MXene flakes toward HER and OER caused by non-uniform doping.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualization of Plasmonic Couplings Using Ultrafast Electron Microscopy

Hybrids of graphene and metal plasmonic nanostructures are promising building blocks for applications in optoelectronics, surface-enhanced scattering, biosensing, and quantum information. An understanding of the coupling mechanism in these hybrid systems is of vital importance to its applications. Previous efforts in this field mainly focused on spectroscopic studies of strong coupling within the hybrids with no spatial resolution. In this study, we report direct imaging of the local plasmonic coupling between single Au nanocapsules and graphene step edges at the nanometer scale by photon-induced near-field electron microscopy in an ultrafast electron microscope for the first time. The proximity of a step in the graphene to the nanocapsule causes asymmetric surface charge density at the ends of the nanocapsules. Computational electromagnetic simulations confirm the experimental observations. The results reported here indicate that this hybrid system could be used to manipulate the localized electromagnetic field on the nanoscale, enabling promising future plasmonic devices.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Probing Surface Plasmon Dynamics in Periodic Nanostructures through Ultrafast Electron Microscopy

Surface plasmon polaritons (SPPs) can be manipulated to localize and guide light in subwavelength distances, enabling them to find applications in a wide range of areas, from sensing to quantum computing. Among several methods of SPP excitation, periodic arrays of nano- and microstructures are of particular interest, as they enable engineering SPP properties through structural parameters. Here, in this study, using the photon-induced near-field electron microscopy (PINEM) technique, we investigated the mode formation, coupling, interference, and decay of SPPs in square and hexagonal arrays of circular nanoholes under both visible and near-infrared excitation. Polarization-resolved analysis revealed the key factors governing SPP localization and interference patterns, showing that the periodicity and symmetry of the array primarily determine the SPP interference patterns and their orientation, while pump polarization mainly modulates their intensity. Time-resolved PINEM measurements demonstrated the spatial dependence of the SPP temporal characteristics. In addition, cathodoluminescence (CL) spectroscopy was employed to examine the intrinsic plasmonic characteristics of the structure. Finite difference time domain (FDTD) simulations showed strong agreement with both PINEM and CL measurements on the spatial and spectral behavior of SPPs. Understanding the spatiotemporal dynamics of SPPs on nanostructures beyond the diffraction limit is crucial for optimizing plasmonic structures for advanced photonic and quantum technologies.

Plasmonics↗