Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “METROLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Metrology and Alignment of Light Weight Grazing Incidence X-Ray Mirrors

Metrology and alignment of light weight X-ray optics have been a challenge for two reasons: (1) that the intrinsic mirror quality and distortions caused by handling can not be easily separated, and (2) the diffraction limits of the visible light become a severe problem at the order of one arc-minute. Traditional methods of using a normal incident pencil or small parallel beam which monitors a tiny fraction of the mirror in question at a given time can not adequately monitor those distortions. We are developing a normal incidence setup that monitors a large fraction, if not the whole, of the mirror at any given time. It will allow us to align thin X-ray mirrors to-an accuracy of a few arc seconds or to a limit dominated by the mirror intrinsic quality.

Zhang, William↗

Radius of Curvature Measurements: An Independent Look at Accuracy Using Novel Optical Metrology

The AMSD (Advanced Mirror System Demonstrator) program mirror specifications include the ability to manufacture the mirror to a radius of curvature of 10 m +/- 1 mm and to control its radius at 30K to the same specification. Therefore, it is necessary for the Government Team to be able to measure mirror radius of curvature to an accuracy of better than 0.5 mm. This presentation discusses a novel optical metrology system for measuring radius of curvature.

Taylor, Bryon↗

Fabrication and Metrology of High-Precision Foil Mirror Mounting Elements

During the period of this Cooperative Agreement, MIT (Massachusetts Institute of Technology) developed advanced methods for applying silicon microstructures for the precision assembly of foil x-ray optics in support of the Constellation-X Spectroscopy X-ray Telescope (SXT) development effort at Goddard Space Flight Center (GSFC). MIT developed improved methods for fabricating and characterizing the precision silicon micro-combs. MIT also developed and characterized assembly tools and several types of metrology tools in order to characterize and reduce the errors associated with precision assembly of foil optics. Results of this effort were published and presented to the scientific community and the GSFC SXT team. A bibliography of papers and presentations is offered.

Schattenburg, Mark L.↗

A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the performance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques.

Toland, Ronald W.↗

A Precision Metrology System for the Hubble Space Telescope Wide Field Camera 3 Instrument

The Wide Field Camera 3 (WFC3) instrument for the Hubble Space Telescope (HST) will replace the current Wide Field and Planetary Camera 2 (WFPC2). By providing higher throughput and sensitivity than WFPC2, and operating from the near-IR to the near-UV, WFC3 will once again bring the pefiormance of HST above that from ground-based observatories. Crucial to the integration of the WFC3 optical bench is a pair of 2-axis cathetometers used to view targets which cannot be seen by other means when the bench is loaded into its enclosure. The setup and calibration of these cathetometers is described, along with results from a comparison of the cathetometer system with other metrology techniques. Finally, the use of the cathetometers on the flight optical bench and measurement results are given.

Toland, Ronald W.↗

Metrology Evaluation of Superfinished Gears Completed

Gears, bearings, and similar mechanical elements transmit loads through the surfaces that are in contact with one another. Thus, the fatigue lives of gears can be improved by providing smoother tooth surfaces. At the NASA Lewis Research Center, we completed a metrology evaluation of one method for making gears with a highly polished, mirrorlike surface. The polished gears were measured carefully. The measurement data showed that the polishing process did, indeed, reduce the surface roughness but did not change the overall tooth shape in any harmful way. This work was done as a partnership of NASA, the U.S. Army, and the University of Wales. NASA provided conventionally ground gear specimens and has begun testing to determine the fatigue lives of the superfinished gears. Under contract, the University of Wales superfinished the gears and inspected them before and after the superfinishing operation. The U.S. Army European Research Office provided the funds and procured the contract with the University of Wales.

Krantz, Timothy L.↗

Metrology for the Development of High Energy X-Ray Optics

We are developing grazing incidence x-ray optics for a balloon-borne hard-x-ray telescope (HERO). The instrument will have 200 sq cm effective collecting area at 40 keV and an angular resolution goal of 15 arcsec. The HERO mirror shells are fabricated using electroform-nickel replication off super-polished cylindrical mandrels. The angular resolution goal puts stringent requirements on the quality of x-ray mirrors and, hence, on mandrel quality. We used metrology in an iterative approach to monitor and refine the x- ray mirror fabrication process. Comparison of surface figure and microroughness measurements of the mandrel and the shells will be presented together with results from x-ray tests.

Gubarev, Mikhail↗

Formation metrology and control for large separated optics space telescopes

In this paper we present formation flying performance analysis initial results for a representative large space telescope composed of separated optical elements [Mett 02]. A virtual-structure construct (an equivalent rigid body) is created by unique metrology and control that combines both centralized and decentralized methods. The formation may be in orbit at GEO for super-resolution Earth observation, as in the case of Figure 1, or it may be in an Earth-trailing orbit for astrophysics, Figure 2. Extended applications are envisioned for exo-solar planet interferometric imaging by a formation of very large separated optics telescopes, Figure 3. Space telescopes, with such large apertures and f/10 to f/100 optics, are not feasible if connected by massive metering structures. Instead, the new virtual-structure paradigm of information and control connectivity between the formation elements provides the necessary spatial rigidity and alignment precision for the telescope.

formation flying virtual-structure telescopes↗

OSI Metrology Gauges

OSI requires a metrology system to measure the three dimensional baseline vector between any two of its siderostats and the distance from the beam combiner to the baseline end points.

Gursel, Y.↗

L2 Earth atmosphere observatory : formation guidance, metrology, and control synthesis

This paper discusses the results of research sponsored by the NASA Revolutionary Aerospace Systems Concepts (RASC) program, and includes the synthesis and analysis of the guidance, metrology and control for a two-spacecraft formation in a unique continuously powered orbit near the Sun-Earth L2 Lagrange point observing the illuminated atmosphere of the Earth while it is continuously occulting the Sun.

observatory↗

Metrology system for the Terrestrial Planet Finder Coronagraph

The Terrestrial Planet Finder (TPF) employs an aggressive coronagraph designed to obtain better than 1e-10 contrast inside the third Airy ring. Minute changes in low-order aberration content scatter significant light at this position. One implication is the requirement to control low-order aberrations induced by motion of the secondary mirror relative to the primary mirror; sub-nanometer relative positional stability is required. We propose a 6-beam laser truss to monitor the relative positions of the two mirrors. The truss is based on laser metrology developed for the Space Interferometry Mission.

Terrestrial Planet Finder (TPF)↗

The Fourier-Kelvin Stellar Interferometer (FKSI) Nulling Testbed II: Closed-loop Path Length Metrology And Control Subsystem

The Fourier-Kelvin Stellar Interferometer (FKSI) is a mission concept for an imaging and nulling interferometer in the near to mid-infrared spectral region (3-8 microns), and will be a scientific and technological pathfinder for upcoming missions including TPF-I/DARWIN, SPECS, and SPIRIT. At NASA's Goddard Space Flight Center, we have constructed a symmetric Mach-Zehnder nulling testbed to demonstrate techniques and algorithms that can be used to establish and maintain the 10(exp 4) null depth that will be required for such a mission. Among the challenges inherent in such a system is the ability to acquire and track the null fringe to the desired depth for timescales on the order of hours in a laboratory environment. In addition, it is desirable to achieve this stability without using conventional dithering techniques. We describe recent testbed metrology and control system developments necessary to achieve these goals and present our preliminary results.

Frey, B. J.↗

The Least-Squares Calibration on the Micro-Arcsecond Metrology Test Bed

The Space Interferometry Mission (S1M) will measure optical path differences (OPDs) with an accuracy of tens of picometers, requiring precise calibration of the instrument. In this article, we present a calibration approach based on fitting star light interference fringes in the interferometer using a least-squares algorithm. The algorithm is first analyzed for the case of a monochromatic light source with a monochromatic fringe model. Using fringe data measured on the Micro-Arcsecond Metrology (MAM) testbed with a laser source, the error in the determination of the wavelength is shown to be less than 10pm. By using a quasi-monochromatic fringe model, the algorithm can be extended to the case of a white light source with a narrow detection bandwidth. In SIM, because of the finite bandwidth of each CCD pixel, the effect of the fringe envelope can not be neglected, especially for the larger optical path difference range favored for the wavelength calibration.

interferometer calibrations↗

Some Considerations for Precision Metrology of Thin X-Ray Mirrors

Determination of the shape of very thin x-ray mirrors employed in spaced-based telescopes continues to be challenging. The mirrors shapes are not readily deduced to the required accuracy because the mount induced distortions are often larger than the uncertainty tolerable for the mission metrology. In addition to static deformations, dynamic and thermal considerations are exacerbated for this class of mirrors. We report on the performance of one temporary mounting scheme for the thin glass mirrors for the Constellation-X mission and prospects for deducing their undistorted shapes.

Lehan, J. P.↗

Swept Frequency Laser Metrology System

A swept frequency laser ranging system having sub-micron accuracy that employs multiple common-path heterodyne interferometers, one coupled to a calibrated delay-line for use as an absolute reference for the ranging system. An exemplary embodiment uses two laser heterodyne interferometers to create two laser beams at two different frequencies to measure distance and motions of target(s). Heterodyne fringes generated from reflections off a reference fiducial X(sub R) and measurement (or target) fiducial X(sub M) are reflected back and are then detected by photodiodes. The measured phase changes Delta phi(sub R) and Delta phi (sub m) resulting from the laser frequency swept gives target position. The reference delay-line is the only absolute reference needed in the metrology system and this provides an ultra-stable reference and simple/economical system.

Zhao, Feng↗

Heterodyne Interferometer Angle Metrology

A compact, high-resolution angle measurement instrument has been developed that is based on a heterodyne interferometer. The common-path heterodyne interferometer metrology is used to measure displacements of a reflective target surface. In the interferometer setup, an optical mask is used to sample the measurement laser beam reflecting back from a target surface. Angular rotations, around two orthogonal axes in a plane perpendicular to the measurement- beam propagation direction, are determined simultaneously from the relative displacement measurement of the target surface. The device is used in a tracking telescope system where pitch and yaw measurements of a flat mirror were simultaneously performed with a sensitivity of 0.1 nrad, per second, and a measuring range of 0.15 mrad at a working distance of an order of a meter. The nonlinearity of the device is also measured less than one percent over the measurement range.

Hahn, Inseob↗