Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MASS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Mu2e Solenoid Cold Mass Position Monitor System

The Mu2e experiment at Fermilab is designed to search for charged-lepton flavor violation by looking for muon to electron conversions in the field of the nucleus. The concept of the experiment is to generate a low momentum muon beam, stopping the muons in a target and measuring the momentum of the outgoing electrons. The implementation of this approach utilizes a complex magnetic field composed of graded solenoidal and toroidal fields. The location of the solenoid cold mass relative to external fiducials is needed for alignment as well as monitoring coil movements during cool down and magnet excitation. This study describes a novel design of a Cold Mass Position Monitor System (CMPS) that will be implemented for the Mu2e experiment.

43 PARTICLE ACCELERATORS↗

A Method to Estimate the Atomic Number and Mass Thickness of Intervening Materials in Uranium and Plutonium Gamma-Ray Spectroscopy Measurements

To accurately characterize shielded special nuclear materials (SNM) using passive gamma-ray spectroscopy measurement techniques, the effective atomic number and the thickness of shielding materials must be measured. Intervening materials between the source and detector may affect the estimated source isotopics (uranium enrichment and plutonium grade) for techniques which rely on raw count rates or photopeak ratios of gamma-ray lines separated in energy. Furthermore, knowledge of the surrounding materials can provide insight regarding the configuration of a device containing SNM. The described method was developed using spectra recorded using high energy resolution CdZnTe detectors, but can be expanded to any gamma-ray spectrometers with energy resolution of better than 1% FWHM at 662 keV. The effective atomic number, Z, and mass thickness of the intervening shielding material are identified by comparing the relative attenuation of different gamma-ray lines and estimating the proportion of Compton scattering interactions to photoelectric absorptions within the shield. While characteristic Kα x-rays can be used to identify shielding materials made of high Z elements, this method can be applied to all shielding materials. This algorithm has adequately estimated the effective atomic number for shields made of iron, aluminum, and polyethylene surrounding uranium samples using experimental data. The mass thicknesses of shielding materials have been estimated with a standard error of less than 1.3 g/cm2 for iron shields up to 2.5 cm thick. The effective atomic number was accurately estimated to 26 ± 5 for all iron thicknesses.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Measurement of the top quark mass in the $t\bar{t}\rightarrow $ lepton+jets channel from $\sqrt{s}=8$ TeV ATLAS data and combination with previous results

The top quark mass is measured using a template method in the $t\bar{t}$→ lepton+jets channel (lepton is e or μ) using ATLAS data recorded in 2012 at the LHC. The data were taken at a proton–proton centre-of-mass energy of √s = 8 TeV and correspond to an integrated luminosity of 20.2 fb –1 . The $t\bar{t}$ → lepton+jets channel is characterized by the presence of a charged lepton, a neutrino and four jets, two of which originate from bottom quarks (b). Exploiting a three-dimensional template technique, the top quark mass is determined together with a global jet energy scale factor and a relative b-to-light-jet energy scale factor. The mass of the top quark is measured to be m top = 172.08 ± 0.39(stat) ± 0.82(syst) GeV. A combination with previous ATLAS m top measurements gives m top = 172.69 ± 0.25(stat) ± 0.41(syst) GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

In situ mass analysis of particles by surface ionization mass spectrometry

A qualitative study of the application of surface ionization and mass spectrometry to the in situ detection and constituent analysis of atmospheric particles was conducted. The technique consists of mass analysis of ions formed as a result of impingement of a stream of particles on a hot filament where, it is presumed, surface ionization takes place. Laboratory air particles containing K, Ca, and possibly hydrocarbons were detected. Other known particles such as Al2O3, Pb(NO3)2, and Cr2O3 were analyzed by detecting the respective metal atoms making up the particles. In some cases, mass numbers indicative of compounds making up the particles were detected showing surface ionization of particles sometimes leads to chemical analysis as well as to elemental analysis. Individual particles were detected, and it was shown that the technique is sensitive to Al2O3 particles with a mass of a few nanograms.

Lassiter, W. S.↗

A highly accurate method for the determination of mass and center of mass of a spacecraft

An extremely accurate method for the measurement of mass and the lateral center of mass of a spacecraft has been developed. The method was needed for the Voyager spacecraft mission requirement which limited the uncertainty in the knowledge of lateral center of mass of the spacecraft system weighing 750 kg to be less than 1.0 mm (0.04 in.). The method consists of using three load cells symmetrically located at 120 deg apart on a turntable with respect to the vertical axis of the spacecraft and making six measurements for each load cell. These six measurements are taken by cyclic rotations of the load cell turntable and of the spacecraft, about the vertical axis of the measurement fixture. This method eliminates all alignment, leveling, and load cell calibration errors for the lateral center of mass determination, and permits a statistical best fit of the measurement data. An associated data reduction computer program called MASCM has been written to implement this method and has been used for the Voyager spacecraft.

Chow, E. Y.↗

The close multiple system mu Orionis - Masses and the mass-luminosity relation

The observations made of the secondary component B of the close visual binary mu Ori are described. The Reticon observations made at red wavelengths showed the secondary to be a double-lined spectroscopic binary with a period of 4.78 days and nearly identical components having minimum masses of 1.1 solar mass each. Previous estimates are corroborated by the large spectroscopic mass ratio of B to A and B. The discovery that B is a pair of late-F dwarfs solves the apparent mass-luminosity relation discrepancy noted in previous studies.

Fekel, F. C., Jr.↗

Interpretation of the ion mass spectra in the mass per charge range 25-35 amu/e obtained in the inner coma of Halley's comet by the HIS-sensor of the Giotto IMS experiment

The IMS-HIS double-focusing mass spectrometer that flew on the Giotto spacecraft covered the mass per charge range from 12 to 56 (amu/e). By comparing flight data, calibration data and results of model calculations of the ion population in the inner coma, the absolute mass scale is established, and ions in the mass range 25 to 35 are identified. Ions resulting from protonation of molecules with high proton affinity are relatively abundant, enabling us to estimate relative source strengths for H2CO, CH3OH, HCN, and H2S, providing for the first time a positive in situ measurement of methanol. Also, upper limits for NO and some hydrocarbons are derived.

Geiss, J.↗

Interpretation of the ion mass spectra in the mass range 25-35 obtained in the inner coma of Halley's comet by the HIS-sensor of the Giotto IMS Experiment

The IMS-HIS double-focussing mass spectrometer that flew on the Giotto spacecraft covered the mass per charge range from 12 to 56 (AMU/e). By comparing flight data, calibration data, and results of model calculations of the ion population in the inner coma, the absolute mass scale is established, and ions in the mass range 25 to 35 are identified. Ions resulting from protonation of molecules with high proton affinity are relatively abundant, enabling us to estimate relative source strengths for H2CO, CH3OH, HCN, and H2S, providing for the first time a positive in situ measurement of methanol. Also, upper limits for NO and some hydrocarbons are derived.

Geiss, J.↗

The Miller Range Nakhlites: A Summary of the Curatorial Subdivision of the Main Mass in Light of Newly Found Paired Masses

The 2003-2004 ANSMET team re-covered a 715.2 g nakhlite from the Miller Range (MIL) region of the Transantarctic Mountains (MIL 03346). This was the first nakhlite for the US Antarctic meteorite program, and after the announcement in 2004 [1], JSC received over 50 requests for this sample for the Fall 2004 Meteorite Working Group meeting. Since then it has been subdivided into >200 splits, and distributed to approx.70 scientists around the world for study. The 2009-2010 ANSMET team recovered three additional masses of this nakhlite [2], making the total amount of mass 1.871 kg (Table 1). Given that the original find (MIL 03346) has been heavily studied and these new masses are available, we will present a comprehensive overview of the subdivision of the original mass as well as the scientific findings to date.

Righter, Kevin↗

On Dark Peaks and Missing Mass: A Weak-Lensing Mass Reconstruction of the Merging Cluster System A520

Merging clusters of galaxies are unique in their power to directly probe and place limits on the self-interaction cross-section of dark matter. Detailed observations of several merging clusters have shown the intracluster gas to be displaced from the centroids of dark matter and galaxy density by ram pressure, while the latter components are spatially coincident, consistent with collisionless dark matter. This has been used to place upper limits on the dark matter particle self-interaction cross-section of order 1 sq cm/g. The cluster A520 has been seen as a possible exception. We revisit A520 presenting new Hubble Space Telescope Advanced Camera for Surveys mosaic images and a Magellan image set. We perform a detailed weak-lensing analysis and show that the weak-lensing mass measurements and morphologies of the core galaxy-filled structures are mostly in good agreement with previous works. There is, however, one significant difference: We do not detect the previously claimed "dark core" that contains excess mass with no significant galaxy overdensity at the location of the X-ray plasma. This peak has been suggested to be indicative of a large self-interaction cross-section for dark matter (at least approx 5alpha larger than the upper limit of 0.7 sq cm/g determined by observations of the Bullet Cluster). We find no such indication and instead find that the mass distribution of A520, after subtraction of the X-ray plasma mass, is in good agreement with the luminosity distribution of the cluster galaxies.We conclude that A520 shows no evidence to contradict the collisionless dark matter scenario.

Clowe, Douglas↗

Iodine-Containing Mass-Defect-Tuned Dendrimers for Use as Internal Mass Spectrometry Calibrants

Calibrants based on synthetic dendrimers have been recently proposed as a versatile alternative to peptides and proteins for both MALDI and ESI mass spectrometry calibration. Because of their modular synthetic platform, dendrimer calibrants are particularly amenable to tailoring for specific applications. Utilizing this versatility, a set of dendrimers has been designed as an internal calibrant with a tailored mass defect to differentiate them from the majority of natural peptide analytes. This was achieved by incorporating a tris-iodinated aromatic core as an initiator for the dendrimer synthesis, thereby affording multiple calibration points (m/z range 600–2300) with an optimized mass-defect offset relative to all peptides composed of the 20 most common proteinogenic amino acids. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computational Removal of Undesired Mass Spectral Features Possessing Repeat Units via a Kendrick Mass Filter

Polymers are a common component of chemical background which complicates data analysis and can impair interpretation. Undesired chemical background cannot always be addressed via pre-analytical methods, chromatography, or existing data processing methods. The Kendrick mass filter (KMF) is presented for the computational removal of undesired signals present in MS{sup 1} spectra. The KMF is analogous to mass defect filtering but utilizes homology information via Kendrick mass scaling in combination with chromatographic retention time and the number of observed signals. The KMF is intended to assist in situations in which current data processing methods to remove background, e.g., blank subtraction, are either not possible or effective. The major parameters affecting KMF were investigated using PEG 400 and NIST standard reference material 1950 (metabolites in human plasma). Further exploration of the KMF performance was tested using an extract of a swab known to contain polymers. An illustrative real-world example of skin analysis with polymeric signal is discussed. The KMF is also able to provide a high-level view of the compositionality of data regarding the presence of signals with repeat units and indicate the presence of different polymers. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Studies on Poly(2-oxazoline) Side Chain Isomers Using Tandem Mass Spectrometry and Ion Mobility-Mass Spectrometry

When polymer mixtures become increasingly complex, the conventional analysis techniques become insufficient for complete characterization. Mass spectrometric techniques can satisfy this increasing demand for detailed sample characterization. Even though isobaric polymers are indistinguishable using simple mass spectrometry (MS) analyses, more advanced techniques such as tandem MS (MS/MS) or ion mobility (IM) can be used. Here, we report proof of concept for characterizing isomeric polymers, namely poly(2-n-propyl-2-oxazoline) (Pn-PrOx) and poly(2-isopropyl-2-oxazoline) (Pi-PrOx), using MS/MS and IM-MS. Pi-PrOx ions lose in intensity at higher accelerating voltages than Pn-PrOx ions during collision-induced dissociation (CID) MS/MS experiments. A Pn/i-PrOx mixture could also be titrated using survival yield calculations of either precursor ions or cation ejection species. IM-MS yielded shape differences in the degree of polymerization (DP) regions showing the structural rearrangements. Combined MS techniques are thus able to identify and deconvolute the molar mass distributions of the two isomers in a mixture. Finally, the MS/MS and IM-MS behaviors are compared for interpretation. .

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tannic Acid: a Novel Calibrator for Facile and Accurate Mass Measurement of Electrospray Ionization Mass Spectrometry

Accurate mass calibration is beneficial to the identification of the unknown compounds quickly and accurately. The ESI mass spectrum of tannic acid (TA) tends to a normal distribution of the cluster ion peaks in m/z range from 371.0368 to 1739.1169. Based on the interesting result, we reported the use of TA, a natural plant polyphenol, as a novel calibrator for electrospray ionization mass spectrometry (ESI MS), which has the following three advantages, including (1) easy preparation, (2) the calibration range of m/z 200~2000, and (3) the calibration error is around 3.00 ppm in positive ion mode, which is less than the use of sodium formate (SF) and Prod #88323 calibrators. This TA calibrator has great potential for the wide applications in biological, chemical, and pharmacal analysis. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Purification of Lithium-Ion Battery Black Mass through Tailored Alkaline Corrosion

Obtaining high-purity material outputs is crucial to the viability of novel process aimed at direct recycling of lithium-ion batteries. Metallic impurities in recycled cathodes have been shown to inhibit performance, thereby threatening mainstream acceptance of recycled battery products. Thus, shredded black mass (BM) must be purified to remove metallic contaminants, and specifically Al and Cu originating from the electrode current collectors. We herein explore a process to ionize solid copper and aluminum to ionic form based on tailored alkaline chemistry, without incurring damage to the target cathode material (Li(NixMnyCo1-x-y)O2; NMC). Al and Cu corrosion may be enhanced through the addition of chloride salt, elevated temperatures, and the use of ultrasonication - all of which disrupt the formation of passivating films on the metallic surface, and thereby increase corrosion rate. We demonstrate optimized parameters for Al and Cu corrosion both from a kinetic and overall process cost perspective. Further, we analyze the impact of these conditions on the structural (XRD, SEM), chemical (EDS, ICP), and electrochemical (impedance, cycling, dQ/dV) properties of NMC, and suggest that the present purification method does not significantly disrupt NMC performance. Finally, we present preliminary results from a promising bench-scale demonstration of this purification process applied to a simulated black mass.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Submicron mass spectrometry imaging of single cells by combined use of mega electron volt time-of-flight secondary ion mass spectrometry and scanning transmission ion microscopy

In order to better understand biochemical processes inside an individual cell, it is important to measure the molecular composition at the submicron level. One of the promising mass spectrometry imaging techniques that may be used to accomplish this is Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS), using MeV energy heavy ions for excitation. MeV ions have the ability to desorb large intact molecules with a yield that is several orders of magnitude higher than conventional SIMS using keV ions. In order to increase the spatial resolution of the MeV TOF-SIMS system, we propose an independent TOF trigger using a STIM (scanning transmission ion microscopy) detector that is placed just behind the thin transmission target. This arrangement is suitable for biological samples in which the STIM detector simultaneously measures the mass distribution in scanned samples. The capability of the MeV TOF-SIMS setup was demonstrated by imaging the chemical composition of CaCo-2 cells.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mass selective separation applied to radioisotopes of cesium: Mass selective applied to radioisotopes

A developed technique that uses the intrinsic mass-based separation capability of a quadrupole mass spectrometer has been used to resolve spectral radiometric interference of two isotopes of the same element. In this work the starting sample was a combination of 137Cs and 134Cs and was (activity) dominated by 137Cs and this methodology separated and “implanted” 134Cs that was later quantified for spectral features and ac- tivity with traditional radiometric techniques. This work demonstrated a 134Cs/137Cs activity ratio enhancement of >4 orders of magnitude and complete removal of 137Cs spectral features from the implanted target mass (i.e., 134).

Cesium↗