Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The ratio R{sub dp} of the quasielastic nd {yields} p(nn) to the elastic np {yields} pn charge-exchange-process yields at the proton emitting angle {theta}{sub p,lab} = 0 deg. over 0.55-2.0 GeV neutron beam energy region. Experimental results

New experimental results on ratio R{sub dp} of the quasielastic charge-exchange yield at the outgoing proton angle {theta}{sub p,lab} = 0 deg. for the nd {yields} p(nn) reaction to the elastic np {yields} pn charge-exchange yield, are presented. The measurements were carried out at the Nuclotron of the Veksler and Baldin Laboratory of High Energies of the JINR (Dubna) at the neutron-beam kinetic energies of 0.55, 0.8, 1.0, 1.2, 1.4, 1.8, and 2.0 GeV. The intense neutron beam with small momentum spread was produced by breakup of deuterons which were accelerated and extracted to the experimental hall. In both reactions mentioned above the outgoing protons with the momenta p{sub p} approximately equal to the neutron-beam momentum p{sub n,beam} were detected in the directions close to the direction of incident neutrons, i.e., in the vicinity of the scattering angle {theta}{sub p,lab} = 0 deg. Measured in the same data-taking runs, the angular distributions of the charge-exchange-reaction products were corrected for the well-known instrumental effects and averaged in the vicinity of the incident-neutron-beam direction. These corrected angular distributions for every of nd {yields} p(nn) and np {yields} pn charge-exchange processes were proportional to the differential cross sections of the corresponding reactions. The data were accumulated by Delta-Sigma setup magnetic spectrometer with two sets of multiwire proportional chambers located upstream and downstream of the momentum analyzing magnet. Inelastic processes were considerably reduced by the additional detectors surrounding the hydrogen and deuterium targets. The time-of-flight system was applied to identify the detected particles. The accumulated data treatment and analysis, as well as possible sources of the systematic errors are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Construction of an alternating gradient magnetometer

A magnetometer is described which was constructed to facilitate the study and characterization of the magnetic properties of high transition temperature superconductors. This instrument was used to measure the dc magnetic susceptibility of several superconducting compounds as a function of temperature. The construction of the magnetometer and the operating parameters are discussed in detail.

Garland, Michael M.↗

DSIF FR-900 video recorders

Deep Space Instrumentation Facility FR-900 ROTARY head magnetic tape recorders for acquiring video data from lunar orbiter

MAGNETIC TAPE RECORDER↗

Global Geospace Science (GGS) Program and the Polar Satellite

The Global Geospace Science (GGS) program's Polar satellite is reported on. The satellite aims to measure: the plasma flux in the polar magnetosphere and the geomagnetic tail; the plasma flux to and from the ionosphere, and the deposition of particle energy in the upper atmosphere. To accomplish these objectives, the satellite was placed on a 86 deg inclination, elliptical orbit whose apogee is located over the northern polar region. The spacecraft carries instruments for observing and measuring the magnetic field and charged particles as well as the imaging instruments.

Hoffman, R. A.↗

Magnetic back-to-back locator

A back-to-back locator instrument includes a first portion with an array of two or more magnetic sensors, and an indicator arrangement. A second portion of the instrument includes an array of correspondingly located magnets. Each of the first and second portions includes a marking arrangement, which either allows marking of the underlying surface, or viewing of a mark on the surface for properly locating the instrument portion thereon. When the two portions are congruent or registered, the indicator arrangement gives a maximum indication of corresponding locations. In a particular use, corresponding locations on the inside and outside of a tank are identified. The indicator arrangement may include a separate indicator for each magnetic sensor. A flux concentrator may be associated with each magnetic sensor.

Phillips, Scott G.↗

Overview of the Solar Ultraviolet Magnetograph Investigation

Traditional magnetographs measure the solar magnetic field at the visible "surface" of the Sun, the photosphere. The Solar Ultraviolet Magnetograph Investigation (SUMI) is a design study for an instrument to measure the solar magnetic field higher in the atmosphere, in the upper chromosphere and in the transition region at the base of the corona. The magnetic pressure at these levels is much stronger than the gas pressure (in contrast to the situation at the photosphere), and so the field is much more dynamic. Observations in this region will significantly improve our understanding of the physical processes driving flares and heating in the Sun's upper atmosphere. The instrument will incorporate new technologies to achieve the polarization efficiencies required to isolate the magnetic lines (Civ at 155nm and MgII at 280nm) to be observed in the UV. We describe the scientific goals, the SUMI baseline design and the optical components that are being developed for a sounding rocket program.

West, Edward A.↗

Miniature Magnetic Resonance Spectrometers

For the purpose of in-situ planeatry exploration, such as chemical characterization of Martian surface materials by miniature instruments, we have developed miniature Magnetic Resonance Spectrometers (MRS) namely, Nuclear Magnetic Resonance (NMR) and Electron Paramagnetic Resonance (EPR) spectrometers at JPL.

Proton-NMR↗

Study of HTS Wires at High Magnetic Fields

Fermilab is working on the development of high field magnet systems for ionization cooling of muon beams. The use of high temperature superconducting (HTS) materials is being considered for these magnets using Helium refrigeration. Critical current (I{sub c}) measurements of HTS conductors were performed at FNAL and at NIMS up to 28 T under magnetic fields at zero to 90 degree with respect to the sample face. A description of the test setups and results on a BSCCO-2223 tape and second generation (2G) coated conductors are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Stable Solar Analyzer

Progress in the development of an instrument with very high (1:10 billion) wavelength stability designed to measure solar surface velocities and magnetic fields is reported. The instrument determines Doppler and Zeeman shifts in solar spectral lines by a 6-point weighted average. It is built around an electrically tunable solid lithium-niobate Fabry-Perot etalon that is stabilized against a diode laser which itself is locked to a resonance line of cesium 133. Key features are the etalon, which acts as a wide-angle 0.017-nm solar filter, the camera with a specially stabilized shutter, and the instrument control and data collection system. Use of the instrument in helioseismological research is emphasized.

Rust, D. M.↗

Exterior and Interior Polar Cusps: Observations from Hawkeye

Hawkeye plasma, magnetic field, and plasma wave instruments directly sampled the throat of the northern polar cusp as the orientation of the Interplanetary Magnetic Field (IMF) changed from southward to northward on July 3, 1974. Two distinct regions in the polar cusp were identified based on magnetic field, plasma flow and magnetic and electric noise: the interior and exterior cusps. The observations show highly variable flows in the exterior portion of the cusp and constantly strong dawn-dusk flows in the interior portion during periods of strong IMF By component. Results of a minimum variance analysis of the magnetic field at each cusp interface crossing provides evidence that the magnetopause surface normal deviated highly from empirical models. During intervals of relatively steady solar wind dynamic pressure, the motion of the cusp relative to the slow moving spacecraft was modulated by the varying IMF clock angle as observed by IMP 8 in the upstream solar wind. The motion did not show a correlation with internal processes monitored by the A E index. We propose that observed plasma flow patterns and cusp motion are results of reconnection between the IMF and the magnetospheric magnetic field. Flow velocity observed in the interior cusp is consistent with stress balance for a reconnection process. This unique interval provides an opportunity for detailed studies of the plasma, magnetic field, and plasma wave properties in both the exterior and interior cusp.

Chen, S.-H.↗

Solar Physics

The areas of emphasis are: (1) develop theoretical models of the transient release of magnetic energy in the solar atmosphere, e.g., in solar flares, eruptive prominences, coronal mass ejections, etc.; (2) investigate the role of the Sun's magnetic field in the structuring of solar corona by the development of three-dimensional numerical models that describe the field configuration at various heights in the solar atmosphere by extrapolating the field at the photospheric level; (3) develop numerical models to investigate the physical parameters obtained by the ULYSSES mission; (4) develop numerical and theoretical models to investigate solar activity effects on the solar wind characteristics for the establishment of the solar-interplanetary transmission line; and (5) develop new instruments to measure solar magnetic fields and other features in the photosphere, chromosphere transition region and corona. We focused our investigation on the fundamental physical processes in solar atmosphere which directly effect our Planet Earth. The overall goal is to establish the physical process for the Sun-Earth connections.

Wu, S. T.↗

Characterization of Bypass Fluid Flow in an Active Magnetic Regenerative Liqueer

Active magnetic regenerators (AMR) with second order magnetocaloric materials operating below the Curie temperature have a unique property where the magnetized specific heat is lower than the demagnetized specific heat. The associated thermal mass unbalance allows a fraction of heat transfer fluid in the cold heat exchanger to bypass the magnetized regenerator. This cold bypassed fluid can precool a process stream as it returns to the hot side, thereby increasing the efficiency of liquefaction and reducing the cost of liquid cryogens. While researchers have been aware of this phenomenon for decades, experimental performance improvements from bypass fluid flow have yet to be reported in open literature. In the present work, the net cooling power of an active magnetic regenerative liquefier is investigated as a function of the bypass ow fraction. Experiments are performed at a fixed temperature span that yield a 25% improvement in net cooling power, affirming the potential of bypass cooling power.

active magnetic regenerator, hydrogen, liquefacati↗

Status of RHIC head-on beam-beam compensation project

Two electron lenses are under construction for RHIC to partially compensate the head-on beam-beam effect in order to increase both the peak and average luminosities. The final design of the overall system is reported as well as the status of the component design, acquisition, and manufacturing. An overview of the RHIC head-on beam-beam compensation project is given in [1], and more details in [2]. With 2 head-on beam-beam interactions in IP6 and IP8, a third interaction with a low-energy electron beam is added near IP10 to partially compensate the the head-on beam-beam effect. Two electron lenses are under construction, one for each ring. Both will be located in a region common to both beams, but each lens will act only on one beam. With head-on beam-beam compensation up to a factor of two improvement in luminosity is expected together with a polarized source upgrade. The current RHIC polarized proton performance is documented in Ref. [4]. An electron lens (Fig. 1) consists of an DC electron gun, warm solenoids to focus the electron beam during transport, a superconducting main solenoid in which the interaction with the proton beam occurs, steering magnets, a collector, and instrumentation. The main developments in the last year are given below. The experimental program for polarized program at 100 GeV was expected to be finished by the time the electron lenses are commissioned. However, decadal plans by the RHIC experiments STAR and PHENIX show a continuing interest at both 100 GeV and 250 GeV, and a larger proton beam size has been accommodated in the design (Tab. 1). Over the last year beam and lattice parameters were optimized, and RHIC proton lattices are under development for optimized electron lens performance. The effect of the electron lens magnetic structure on the proton beam was evaluated, and found to be correctable. Experiments were done in RHIC and the Tevatron.

43 PARTICLE ACCELERATORS↗

Qualification of the US made conductors for ITER TF magnet system

The US Domestic Agency (USDA) is one of the six suppliers of the TF conductor for ITER. In order to qualify conductors according to ITER requirements we prepared several lengths of the CICC and short samples for testing in the SULTAN facility in CRPP, Switzerland. We also fully characterized the strands that were used in these SULTAN samples. Fabrication experience and test results are presented and discussed.

42 ENGINEERING↗

AC electrical transport detection of magnetic properties of small, granular, and heterogeneous samples

Experimental constraints and sample limitations can preclude ideal measurements of electrical transport properties of materials. In such situations, AC electrical transport methods are often employed due to a significant increase in signal-to-noise ratio they can provide. However, dynamic effects that are not often accounted for may be present that may modify the signals in these measurements. In particular, dynamic filtering effects are prominent in small, granular, and heterogeneous materials. We demonstrate that a lock-in amplifier based circuit can distinguish between these DC transport and AC filtering effects. Here, we further demonstrate that this filtering can reveal distinct signatures of magnetic transitions while providing a measure of sample quality.

47 OTHER INSTRUMENTATION↗

Itinerancy enhanced quantum fluctuation of magnetic moments in iron-based superconductors

We investigate the influence of itinerant carriers on dynamics and fluctuation of local moments in Fe-based superconductors, via linear spin-wave analysis of a spin-fermion model containing both itinerant and local degrees of freedom. Surprisingly against the common lore, instead of enhancing the (π,0) order, itinerant carriers with well nested Fermi surfaces is found to induce significant amount of spatial and temporal quantum fluctuation that leads to the observed small ordered moment. Interestingly, the underlying mechanism is shown to be intra-pocket nesting-associated long-range coupling, rather than the previously believed ferromagnetic double-exchange effect. This challenges the validity of ferromagnetically compensated first-neighbor coupling reported from short-range fitting to the experimental dispersion, which turns out to result instead from the ferro-orbital order that is also found instrumental in stabilizing the magnetic order.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Calibration of two compact permanent magnet spectrometers for high current electron linear induction accelerators

In this work, two compact, permanent magnet, electron spectrometers have been built to measure the electron beam energy at the Dual Axis Radiographic Hydrodynamic Test facility. Using H - and OH - anions, the spectrometers were calibrated at the Special Technologies Laboratory in Santa Barbara, California (USA). The spectrometers were mounted on a custom drift tube that allows the magnet assemblies to be translated, which increases the path length of the electrons traveling through the magnetic field and therefore increases the upper bound of the measurable electron kinetic energy. The measurable range of electron kinetic energies is between 2.8 MeV–4.1 MeV for the first spectrometer and 14.1 MeV–21.1 MeV for the second spectrometer, with an overall measurement uncertainty of 0.32%.

47 OTHER INSTRUMENTATION↗