The Q weak experimental apparatus

The Jefferson Lab Q weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was created for this experiment to meet the technical challenges presented by the smallest and most precise e → p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 μA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Møller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8° and 11.6° were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cherenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q 2 =0.025 GeV 2 was observed using dedicated low-current ( ~ 100 pA ) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX

We describe the upgrade of the neutron resonance spin-echo setup at the cold neutron triple-axis spectrometer FLEXX at the BER II neutron source at the Helmholtz-Zentrum Berlin. The parameters of redesigned key components are discussed, including the radio frequency (RF) spin-flip coils, the magnetic shield, and the zero field coupling coils. The RF-flippers with larger beam windows allow for an improved neutron flux transfer from the source to the sample and further to the analyzer. The larger beam cross sections permit higher coil inclination angles and enable measurements on dispersive excitations with a larger slope of the dispersion. Due to the compact design of the spin-echo units in combination with the increased coil tilt angles, the accessible momentum-range in the Larmor diffraction mode is substantially enlarged. In combination with the redesigned components of the FLEXX spectrometer, including the guide, the S-bender polarizer, the double focusing monochromator, and a Heusler crystal analyzer, the count rate increased by a factor of 15.5, and the neutron beam polarization is enhanced. The improved performance extends the range of feasible experiments, both for inelastic scattering on excitation lifetimes in single crystals, and for high-resolution Larmor diffraction. The experimental characterization of the instrument components demonstrates the reliable performance of the new neutron resonance spin-echo option, now available for the scientific community at FLEXX.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Circuit Modeling, Simulation, and Experimental Validation of a 100-kW Polyphase Wireless Power Transfer System for EV Applications

Polyphase wireless power transfer (WPT) systems can achieve much higher surface power densities (kW/m2) and specific power levels (kW/kg) compared to the conventional circular single phase WPT systems. Therefore, polyphase WPT systems can reduce the size, weight, volume, and cost of the WPT systems and can simplify the electric vehicle integration with less demand for space. This study presents the high-performance and compact 100-kW WPT development using polyphase electromagnetic coupling coils with rotating magnetic fields.

Onar, Omer [ORNL] (ORCID:0000000292028857)↗

Thermal Analysis of Wireless Power Transfer Coils for Dynamic Wireless Electric Vehicle Charging

In this paper, safe operating conditions of a wireless power transfer coil were identified and road infrastructure for a dynamic wireless electric vehicle charging system was studied. Magneto-thermal simulations were used to map the power loss directly into the computed fluid dynamics solver. This method allowed the authors to analyze the heating pattern of the enclosed wireless power transfer coil in the road structure, as well as for the vehicle coil. Thermal heating patterns for three types of rectangular coil structures were analyzed. Heating patterns were analyzed for 200 kW coils and different magnetic field densities in the magnetic core.

Wojda, Rafal↗

12th IAEA Technical Meeting on Energetic Particles in Magnetic Confinement Systems (7–11 September 2011) and 5th IAEA Technical Meeting on Theory of Plasma Instabilities (5–7 September 2011)

The 12th IAEA Technical Meeting on Energetic Particles in Magnetic Confinement Systems took place in Austin, Texas (7–11 September 2011). This meeting was organized jointly with the 5th IAEA Technical Meeting on Theory of Plasma Instabilities (5–7 September 2011). The two meetings shared one day (7 September 2011) with presentations relevant to both groups. Some of the work reported at these meetings was then published in a special issue of Nuclear Fusion [Nucl. Fusion 52 (2012)]. Summaries of the Energetic Particle Conference presentations were given by Kazuo Toi and Boris Breizman. They respectively discussed the experimental and theoretical progress presented at the meeting. Highlights of this meeting include the tremendous progress that has been achieved in the development of diagnostics that enables the ‘viewing’ of internal fluctuations and allows comparison with theoretical predictions, as demonstrated, for example, in the talks of P. Lauber and M. Osakabe. The need and development of hardened diagnostics in the severe radiation environment, such as those that will exist in ITER, was discussed in the talks of V. Kiptily and V.A. Kazakhov. In theoretical studies, much of the effort is focused on nonlinear phenomena. For example, detailed comparison of theory and experiment on D-III-D on the n = 0 geodesic mode was reported in separate papers by R. Nazikian and G. Fu. A large number of theoretical papers were presented on wave chirping including a paper by B.N. Breizman, which notes that wave chirping from a single frequency may emanate continuously once marginal stability conditions have been established. Another area of wide interest was the detailed study of alpha orbits in a burning plasma, where losses can come from symmetry breaking due to finite coil number or magnetic field imperfections introduced by diagnostic or test modules. An important area of development, covered by M.A. Hole and D.A. Spong, is concerned with the self-consistent treatment of the induced fields that accounts for toroidally asymmetric MHD response. In addition, a significant number of studies focused on understanding nonlinear behavior by means of computer simulation of energetic particle driven instability. An under-represented area of investigation was the study of electron runaway formation during major tokamak disruptions. It was noted in an overview by S. Putvinski that electron energies in the 10–20 MeV range is to be expected during projected major disruptions in ITER and that reliable methods for mitigation of the runaway process needs to be developed. Significant recent work in the field of the disruption induced electron runaway, which was reported by J. Riemann, had been submitted to Physics of Plasmas. Overall it is clear that reliable mitigation of electron runaway is an extremely important topic that is in need of better understanding and solutions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of system integration methods for bubble domain flight recorders

System integration methods for bubble domain flight records are investigated. Bubble memory module packaging and assembly, the control electronics design and construction, field coils, and permanent magnet bias structure design are studied. A small 60-k bit engineering model was built and tested to demonstrate the feasibility of the bubble recorder. Based on the various studies performed, a projection is made on a 50,000,000-bit prototype recorder. It is estimated that the recorder will occupy 190 cubic in., weigh 12 lb, and consume 12 w power when all of its four tracks are operated in parallel at 150 kHz data rate.

Chen, T. T.↗

Method of fabricating composite structures

A method of fabricating structures formed from composite materials by positioning the structure about a high coefficient of thermal expansion material, wrapping a graphite fiber overwrap about the structure, and thereafter heating the assembly to expand the high coefficient of thermal expansion material to forcibly compress the composite structure against the restraint provided by the graphite overwrap. The high coefficient of thermal expansion material is disposed about a mandrel with a release system therebetween, and with a release system between the material having the high coefficient of thermal expansion and the composite material, and between the graphite fibers and the composite structure. The heating may occur by inducing heat into the assembly by a magnetic field created by coils disposed about the assembly through which alternating current flows. The method permits structures to be formed without the use of an autoclave.

Sigur, W. A.↗

Method of fabricating composite structures

A method of fabricating structures formed from composite materials by positioning the structure about a high coefficient of thermal expansion material, wrapping a graphite fiber overwrap about the structure, and thereafter heating the assembly to expand the high coefficient of thermal expansion material to forcibly compress the composite structure against the restraint provided by the graphite overwrap. The high coefficient of thermal expansion material is disposed about a mandrel with a release system therebetween, and with a release system between the material having the high coefficient of thermal expansion and the composite material, and between the graphite fibers and the composite structure. The heating may occur by inducing heat into the assembly by a magnetic field created by coils disposed about the assembly through which alternating current flows. The method permits structures to be formed without the use of an autoclave.

Sigur, Wanda A.↗

Open-Access, Low-Magnetic-Field MRI System for Lung Research

An open-access magnetic resonance imaging (MRI) system is being developed for use in research on orientational/gravitational effects on lung physiology and function. The open-access geometry enables study of human subjects in diverse orientations. This system operates at a magnetic flux density, considerably smaller than the flux densities of typical other MRI systems, that can be generated by resistive electromagnet coils (instead of the more-expensive superconducting coils of the other systems). The human subject inhales air containing He-3 or Xe-129 atoms, the nuclear spins of which have been polarized by use of a laser beam to obtain a magnetic resonance that enables high-resolution gas space imaging at the low applied magnetic field. The system includes a bi-planar, constant-current, four-coil electromagnet assembly and associated electronic circuitry to apply a static magnetic field of 6.5 mT throughout the lung volume; planar coils and associated circuitry to apply a pulsed magnetic-field-gradient for each spatial dimension; a single, detachable radio-frequency coil and associated circuitry for inducing and detecting MRI signals; a table for supporting a horizontal subject; and electromagnetic shielding surrounding the electromagnet coils.

Mair, Ross W.↗

Field Measurement Results of the 15 T Nb 3 Sn Dipole Demonstrator MDPCT1b

A 15 T Nb 3 Sn dipole with cos-theta-type coils was developed to demonstrate a possible magnet design for a post-LHC proton-proton Collider. The magnet has 4-layer coils with 60-mm aperture, and has graded current density between the inner and outer layers to maximize performance. The coils are constrained by vertically-split, thick iron laminations, connected by aluminum Iclamps, and a thick stainless-steel skin. The magnet was previously tested at the Vertical Magnet Test Facility (VMTF) at Fermilab with reduced pre-load, and achieved record 14.1 T fields at maximum current. Now the magnet has been reassembled with full pre-load and has been cryogenically retested at VMTF. We report here on the magnetic measurements results of these tests, including field strength, geometrical harmonics, coil magnetization, and iron saturation characteristics of the demonstrator.

43 PARTICLE ACCELERATORS↗

Characterization of a linear device developed for research on advanced plasma imaging and dynamics

Within the scope of long term research on imaging diagnostics for steady-state plasmas and understanding of edge plasma physics through diagnostics with conventional spectroscopic methods, we have constructed a linear electron cyclotron resonance (ECR) plasma device named Research on Advanced Plasma Imaging and Dynamics (RAPID). It has a variety of axial magnetic field profiles provided by eight water-cooled magnetic coils and two dc power supplies. The positions of the magnetic coils are freely adjustable along the axial direction and the power supplies can be operated with many combinations of electrical wiring to the coils. Here, a 6 kW 2.45 GHz magnetron is used to produce steady-state hydrogen, helium, and argon plasmas with central magnetic fields of 875 and/or 437.5 G (second harmonic). In order to achieve the highest possible plasma performance within the limited input parameters, wall conditioning experiments were carried out. Chamber bake-out was achieved with heating coils that were wound covering the vessel, and long-pulse electron cyclotron heating discharge cleaning was also followed after 4 days of bake-out. A uniform bake-out temperature (150 deg. C) was achieved by wrapping the vessel in high temperature thermal insulation textile and by controlling the heating coil current using a digital control system. The partial pressure changes were observed using a residual gas analyzer, and a total system pressure of 5x10{sup -8} Torr was finally reached. Diagnostic systems including a millimeter-wave interferometer, a high resolution survey spectrometer, a Langmuir probe, and an ultrasoft x-ray detector were used to provide the evidence that the plasma performance was improved as we desired. In this work, we present characterization of the RAPID device for various system conditions and configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic Interaction between the Component Coils of Multi-Plex Magnets

Ultra-high field pulsed magnets are usually designed as a group of nested, concentric coils driven by separated power sources to reduce the required driving voltages and to distribute the mechanical load and to reduce the driving voltages. Since the magnet operates in a fast transient mode, there will be strong and complicated electromagnetic couplings between the component coils. The high eddy currents generated in the reinforcement shells of the component coils during the pulses also strongly affect these couplings. Therefore, understanding the electromagnetic interaction between the component coils will allow safer, more optimized design and operation of our magnets. As a result, this paper will focus on our finite element modeling and experimental results for the electromagnetic interactions between the component coils of the 100-T nondestructive magnet and 80-T duplex magnet at our facility.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Heat Treatment Optimization of Rutherford Cables for a 15 T Nb 3 Sn Dipole Demonstrator

FNAL has been developing a 15 T Nb 3 Sn dipole demonstrator for a future Very High Energy pp Collider based on an optimized 60-mm aperture 4-layer “cos-theta” coil. In order to increase magnet efficiency, we graded the coil by using two cables with same 15 mm width and different thicknesses made of two different Restacked Rod Process (RRP®) wires. Due to the non-uniform field distribution in dipole coils the maximum field in the inner coil will reach 15-16 T, whereas the maximum field in the outer coil is 12-13 T. In preparation for the 15 T dipole coil reaction, heat treatment studies were performed on strands extracted from these cables with the goal of achieving the best coil performance in the corresponding magnetic fields. Particularly, the effect of maximum temperature and time on the cable critical current was studied to take into account actual variations of these parameters during coil reaction. In parallel and in collaboration with OST, development was performed on optimizing Nb 3 Sn RRP® wire design and layout. Index Terms— Accelerator magnet, critical current density, Nb 3 Sn strand, Rutherford cable.

43 PARTICLE ACCELERATORS↗

Optical measurements for turbulence characterization in RFX-mod edge

The edge of the reversed field pinch experiment RFX-mod (R=2 m, a=0.46 m) is characterized by a complex magnetic topology and strong pressure gradients. A set of fast spectroscopic diagnostics has been designed to characterize both main plasma edge parameters and turbulence, including coherent structures (blobs) and radial profiles of the thermodynamic variables. Measurements of the edge radial profiles of electron density (n{sub e}), temperature (T{sub e}), and pressure (P{sub e}) are obtained by a thermal helium beam diagnostic, which locally measures the ratios of the spectral lines emitted by a neutral He cloud puffed into hydrogen plasma discharges. A gas puff imaging system allows the high frequency (1 MHz bandwidth) measurement of the fluctuations of He I emissivity in the same positions. The system measures both the intermittent behavior of the edge turbulence and n{sub e}, T{sub e}, and P{sub e} profiles of the corresponding coherent structures, with a resolution down to 6 {mu}s. The optical diagnostics are complemented by a set of triaxial magnetic coils to simultaneously characterize the edge magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Progress with high-field superconducting magnets for high-energy colliders

One of the possible next steps for high-energy physics research relies on a high-energy hadron or muon collider. The energy of a circular collider is limited by the strength of bending dipoles, and its maximum luminosity is determined by the strength of final focus quadrupoles. For this reason, the high-energy physics and accelerator communities have shown much interest in higher-field and higher-gradient superconducting accelerator magnets. The maximum field of NbTi magnets used in all present high-energy machines, including the LHC, is limited to ~10 T at 1.9 K. Fields above 10 T became possible with the use of Nb$_3$Sn superconductors. Nb$_3$Sn accelerator magnets can provide operating fields up to ~15 T and can significantly increase the coil temperature margin. Accelerator magnets with operating fields above 15 T require high-temperature superconductors. Furthermore, this review discusses the status and main results of Nb$_3$Sn accelerator magnet research and development and work toward 20-T magnets.

43 PARTICLE ACCELERATORS↗

Plasma Jet Formation Disruption From a Critical Applied Uniform Axial Magnetic Field

We examine the effects of varying the magnitude of an applied, uniform, axial magnetic field (Bz) on the formation of laboratory plasma jets produced by a 1-MA 100-ns rise time pulsed power generator in a radial foil configuration. A Helmholtz coil applies the external magnetic field (0 to 2 T). With a small-enough applied field, the foil surface ablation is relatively azimuthally uniform, and J×B forces drive the ablated plasma inward and upward to form a well-defined azimuthally symmetric jet. Using applied field strengths larger than a critical Bz = 1.1±0.1 T with aluminum foils, the plasma ablation is not azimuthally uniform, discrete bursts of plasma initiate from the foil surface, and the formation of a well-defined jet is disrupted. The critical Bz for this plasma jet formation disruption correlates with the foil material’s electrical resistivity and equation of state (EOS). To better understand the material-dependent phenomenon, we compare the experimental results with 3-D extended magnetohydrodynamics simulations of ablation of a 2 mm × 2 mm by 25-μm slab that represents a section of the radial foil. The simulations initialize the slab in the solid state and include the material resistivity and EOS from the solid to plasma phases. As is observed in the experimental disruption, these simulations show enhanced nonuniform plasma ablation with an applied Bz, which can inhibit the azimuthal uniformity necessary to produce a well-defined plasma jet. Furthermore, the simulations also show a material and resistivity dependence on the ablation process similar to the trend shown by the experiments. These results demonstrate the necessity of accurate, detailed modeling of material properties during the transition from solid to plasma phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗