Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Load Modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The mechanism for acetate formation in electrochemical CO (2) reduction on Cu: selectivity with potential, pH, and nanostructuring

Nanostructured Cu catalysts have increased the selectivities and geometric activities for high value C–C coupled (C 2 ) products (ethylene, ethanol, and acetate) in the electrochemical CO (2) reduction reaction (CO (2) RR). The selectivity among the high-value C 2 products is also altered, where for instance the yield of acetate increases with alkalinity and is dependent on the catalyst morphology. The reaction mechanisms behind the selectivity towards acetate vs. other C 2 products remain controversial. In this work, we elucidate the reaction mechanism for acetate formation by using ab initio simulations, a coupled kinetic-transport model, and loading dependent experiments. We find that trends in acetate selectivity can be rationalized from variations in electrolyte pH and the local mass transport properties of the catalyst and not from changes in Cu's intrinsic activity. The selectivity mechanism originates from the transport of ketene, a stable (closed shell) intermediate, away from the catalyst surface into solution where it reacts to form acetate. While this type of mechanism has not yet been discussed in the CO (2) RR, variants of it may explain similar selectivity fluctuations observed for other stable intermediates like CO and acetaldehyde. Our proposed mechanism suggests that acetate selectivity increases with increasing pH, decreasing catalyst roughness and significantly varies with the applied potential.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Factorization Machine Learning for Disaggregation of Transmission Load Profiles with High Penetration of Behind-the-Meter Solar

The ever-growing high penetration of ubiquitously distributed energy resources, especially behind-the-meter solar (BTM) generations, has significant impacts on nodal load (i.e., net injection) profiles and consequently caused imperative operational challenges to system operators such as regional transmission organizations (RTOs). Illustrated by real-world nodal data and examples at PJM Interconnection, this paper first discusses the application and necessity of effectively extracting daily nodal load profiles in a non-intrusive manner. More importantly, a novel bi-level architecture, including Factorization Machines (FM) learning procedure has been proposed to effectively disaggregate not only one node but every node in an RTO service territory. Specifically, FM leaning is adopted to capture the interconnections between related features to better utilize the correlation between buses in the same region and between a single bus and the zonal load. The proposed bi-level technique is numerically validated using real-world, minute-level, normalized, and anonymized nodal data at PJM service territory.

behind the meter solar, load disaggregation, load ↗

Uniform Mechanical Loading Can Test for Nonuniform Loading Durability

In this work, we present a method to evaluate the equivalency between any module mechanical loading conditions. The method is developed to address the specific failure mode of glass fracture and is based on Weibull analysis and weakest link theory. It considers the varying stress profile across the module to calculate the probability of glass fracture, which is used as the metric of equivalency. An idealized nonuniform loading scheme is employed to demonstrate the method and introduce the concept of the equivalent uniform load factor: a factor applied to the maximum pressure of the nonuniform load to obtain the equivalent uniform load value. It is demonstrated that this factor is less than unity for all nonuniform load cases considered, including snow and various characters of wind loading. These significant results suggest that uniform loading may be reliably, and practically, employed to evaluate photovoltaic module glass for nonuniform loading durability.

14 SOLAR ENERGY↗

A Generalized Framework for Service Restoration in a Resilient Power Distribution System

An electric power grid is one of the complex infrastructures, and because of its complex nature, there is simply no way that outages can be completely avoided. Thus, a modern society that depends on reliable electric supply requires a resilient electric system that can recover from disruptions while integrating emerging smart grid technologies. Here, this article presents a novel approach for service restoration in a modern power distribution system with controllable switches and distributed generation (DG) resources for any kind of outage. The proposed framework supports both the traditional service restoration using feeder reconfiguration and the grid-forming DG-assisted intentional islands that are dynamically sized using algorithms based on the fault scenario, available resources, and priority of loads. The problem is formulated as a mixed-integer linear program that incorporates critical system connectivity and operating constraints. Simulations are performed to demonstrate the effectiveness of the proposed approach using a large-scale four-feeder 1069-bus three-phase unbalanced distribution test system. It is demonstrated that the framework is effective in utilizing all available resources in quickly restoring the power supply to improve resiliency during extreme events and is scalable for a large-scale unbalanced power distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Postdisaster Routing of Movable Energy Resources for Enhanced Distribution System Resilience: A Deep Reinforcement Learning-Based Approach

The deployment of movable energy resources (MERs) can be an effective strategy to restore critical loads to enhance power system resilience when no other energy sources are available after the occurrence of an extreme event. Since the optimal locations of MERs following an extreme event are dependent on system operating states (e.g., the loads at each node, on/off status of system branches, and so on), existing analytical and population-based approaches must repeat the entire analysis and calculation when the system operating states change. On the contrary, if deep reinforcement learning (DRL)-based algorithms are sufficiently trained with a wide range of scenarios, they can quickly find optimal or near-optimal locations irrespective of changes in system states. A deep Q-learning-based approach is proposed for optimal MER deployment to enhance power system resilience. MERs can be also utilized to complement other types of resources, if available. The proposed approach operates in two stages after the occurrence of extreme events. In the first stage, the distribution network is represented as a graph, and the network is then reconfigured using tie switches by using Kruskal’s spanning forest search algorithm (KSFSA). To maximize critical load recovery, the optimal or near-optimal locations of MERs are chosen in the second stage. Further, case studies on a 33-node distribution system and a modified IEEE 123-node system demonstrate the effectiveness of the proposed approach for postdisaster routing of MERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Efficient Region of Attraction Characterization for Control and Stabilization of Load Tap Changer Dynamics

In this article, we study the monitoring and control of long-term voltage stability considering load tap changer (LTC) dynamics. We show that under generic conditions, the LTC dynamics admit a unique stable equilibrium. For the stable equilibrium, we characterize an explicit inner approximation of its largest region of attraction (ROA). Compared to existing results, the computational complexity of the ROA characterization is drastically reduced. We propose a quadratically constrained linear program formulation for the ROA characterization problem. In addition, we formulate a second-order cone program for online voltage stability monitoring and control exploiting the proposed ROA characterization. Finally, we demonstrate the efficacy of the proposed formulations on the ROA characterization and stability monitoring and control using a standard IEEE test system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient computational and experimental thermal analysis of graphite foam monoblock

A densified graphite foam is being explored for its applicability as plasma-facing material in fusion devices. Three different graphite foam monoblocks are constructed and tested in the Garching Large Divertor Sample Testing Facility. The monoblock samples consist of graphite foam press-fit to a single tube, graphite foam cubes brazed to a single, and graphite foam cubes press-fit to a single tube. The tube is composed of CuCrZr with a steel twisted tape. The monoblocks are exposed to the heat fluxes of 5, 6, and 8 MW/m 2 for 30 s to determine the maximum surface and body temperatures measured with thermocouple for each monoblock design. The press-fit monoblocks are exposed to 8 MW/m 2 for 15 s for 100 cycles to determine the effect of thermal cycling on the contact between the graphite foam and the tube. STAR-CCM+ is used to predict how much the contact between the foam and tubes varies as a result of thermal cycling. In addition, the 6 MW/m 2 loading is modeled in STAR-CCM+ to compare the transient cooldown curves of the computational results to the recorded temperatures at the surface and two different thermocouple locations. This comparison is used to validate the temperature-dependent thermal conductivity and specific heat capacity used in the models of the graphite foam. The computational modeling of the experiment has been used to hypothesize ways to use and improve upon the graphite foam as a suitable material for fusion applications.

Gehrig, Monica↗

Semi-Supervised, Non-Intrusive Disaggregation of Nodal Load Profiles With Significant Behind-the-Meter Solar Generation

It is of imperative interests for regional transmission organizations (RTOs) to effectively extract actual load profiles at transmission nodes with significant behind-the-meter solar generation, which remains a gap in the existing technology paradigm. This paper proposes an explicit yet efficient linear estimator to disaggregate actual load profiles at transmission buses with significant behind-the-meter (BTM) solar generations. The proposed estimator is based on disaggregating (i.e., extracting) at locations close to transmission buses under consideration. Further, to overcome the lack of “ground truth” and validate the performance of the proposed algorithms, we first propose semi-supervised mechanisms with parameter tuning as well as unsupervised clustering and leverage the unique characteristics of zero-crossing points in BTM solar peaking behaviors, which we refer to as “Zone-to-Node (Z2N)” methods. Next, we further propose a bi-level Node-to-Node (N2N) framework that improves the overall disaggregation performances compared to Z2N. Numerical results are presented using real-world data at PJM Interconnection.

14 SOLAR ENERGY↗

Decentralized Low-Rank State Estimation for Power Distribution Systems

This article considers the low-observability state estimation problem in power distribution networks and develops a decentralized state estimation algorithm leveraging the matrix completion methodology. Matrix completion has been shown to be an effective technique in state estimation that exploits the low dimensionality of the power system measurements to recover missing information. This technique can utilize an approximate (linear) load flow model, or it can be used with no physical models in a network where no information about the topology or line admittance is available. The direct application of matrix completion algorithms requires solving a semi-definite programming (SDP) problem, which becomes computationally challenging for large networks. We therefore develop a decentralized algorithm that capitalizes on the popular proximal alternating direction method of multipliers (proximal ADMM). The method allows us to distribute the computation among different areas of the network, leading to a scalable algorithm. By doing all computations at individual control areas and only communicating with neighboring areas, the algorithm eliminates the need for data to be sent to a central processing unit and thus increases efficiency and contributes to the goal of autonomous control of distribution networks. We illustrate the advantages of the proposed algorithm numerically using standard IEEE test cases.

41 EE - Solar Energy Technologies Office (EE-4S)↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

EnergyPlus Model Context Protocol Server (EnergyPlus-MCP) v0.1

EnergyPlus-MCP is the first open-source Model Context Protocol server specifically designed for EnergyPlus building energy simulation. This innovative software enables AI assistants and other applications to interact programmatically with EnergyPlus through a standardized, secure interface, eliminating traditional technical barriers in building energy modeling. The software provides specialized tools across five functional domains: server management, model configuration and loading, comprehensive building component inspection, systematic model modification, and simulation execution with results visualization. Key features include automated HVAC system discovery and topology mapping, advanced schedule analysis, intelligent model validation, and interactive visualization capabilities. EnergyPlus-MCP's layered architecture ensures robust separation between protocol communication and domain expertise, enabling scalable deployment across organizations, educational institutions, and research teams. Unlike direct LLM approaches that suffer from inconsistent results and security gaps, EnergyPlus-MCP provides validated, reliable interactions while maintaining scientific rigor. This democratizes sophisticated building energy analysis, making EnergyPlus accessible to broader audiences through conversational interfaces and streamlined workflows.

Li, Han [Lawrence Berkeley National Laboratory (LB↗