TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗

Kinetic effect of toroidal rotation on the geodesic acoustic mode

Kinetic effects of the toroidal rotation on the geodesic acoustic mode are theoretically investigated. It is found that when the toroidal rotation increases, the damping rate increases in the weak rotation regime due to the rotation enhancement of wave-particle interaction, and it decreases in the strong rotation regime due to the reduction of the number of resonant particles. Theoretical results are consistent with the behaviors of the geodesic acoustic mode recently observed in DIII-D and ASDEX-Upgrade. The kinetic damping effect of the rotation on the geodesic acoustic mode may shed light on the regulation of turbulence through the controlling the toroidal rotation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermodynamic Analyses of the LCLS-II Cryogenic Distribution System

The Linac Coherent Light Source (LCLS) at Stanford Linear Accelerator Center (SLAC) is in the process of being upgraded to a superconducting radio frequency (SRF) accelerator and renamed LCLS-II. This upgrade requires thirty-five 1.3 GHz SRF cryomodules (CM) and two 3.9 GHz CM. A cryogenic distribution system (CDS) is in development by Fermi National Accelerator Laboratory to interconnect the CM Linac with the cryogenic plant (CP). The CDS design utilizes cryogenic helium to support the CM operations with a high temperature thermal shield around 55 K, a low temperature thermal intercepts around 5 K, and a SRF cavity liquid helium supply and sub-atmospheric vapor return both around 2 K. Additionally the design must accommodate a Linac consisting of two parallel cryogenic strings, supported by two independent CP utilizing CDS components such as distribution boxes, transfer lines, feed caps and endcaps. In this paper, we describe the overall layout of the cryogenic distribution system and the major thermodynamic factors which influence the CDS design including heat loads, pressure drops, temperature profiles, and pressure relieving requirements. In addition the paper describes how the models are created to perform the analyses.

43 PARTICLE ACCELERATORS↗

Demonstration and Evaluation of the Human-Technology Integration Function Allocation Methodology

There is an imminent need for the existing nuclear power plants to reduce their operating and maintenance (O&M) costs to remain economically viable. Digital technology, including automation, provides a significant opportunity for the existing nuclear power plant fleet to transform the way in which work is accomplished, reducing O&M costs, and allowing the fleet to remain economically competitive. One notable opportunity to significantly reduce O&M costs pertains to modifications to the plant equipment and main control room (MCR). Existing instrumentation and control (I&C) technologies in the MCR are highly analog, costly to operate and maintain, and demand a high cognitive and physical workload from plant staff (i.e., operators). Digitalizing the MCR has a range of broad economic benefits, including improved plant performance and reduced manual work. Further, digital I&C systems can fundamentally change the way in which plant staff operate the plant; this is the concept of operation. Human-technology integration is important to ensure that impacts to the concept of operation are done in a way that account for capabilities of people and technology. Human-technology integration employs human factors engineering (HFE) methods and principles to maximize the benefits of digital technology, reducing human error, improving overall decision-making and usability. The U.S. Department of Energy Light Water Reactor Sustainability Program is applying human-technology integration research to ensure digital technologies are safe, reliable, and efficient. This paper documents the demonstration of the human-technology guidance developed by the Light Water Reactor Sustainability Program from a first-of-a-kind digital I&C upgrade, specifically addressing function analysis and allocation for a new digital I&C system that included changes in automation levels. The program’s specific approach is included in this work, following lessons learned. This document serves as a resource for industry to follow in applying human-technology integration and HFE to digital modifications, specific to function analysis and allocation. The lessons learned should be considered in the planning and execution of HFE activities that support such digital modifications.

99 GENERAL AND MISCELLANEOUS↗

A Decade of NSTX Operations Using Collaborative Software

Since the beginning of the National Spherical Torus Experiment's (NSTX) research activities in 1999, open-source and collaborative software have been used extensively for experimental operations. The software included Experimental Physics and Industrial Control System (EPICS) and the Model Data System plus (MDSplus). This paper will begin with a retrospective of ten years of integrated computing, control, and data analysis on NSTX. A variety of practical issues will be reviewed such as: system reliability, availability, and maintainability; using open source software with commercialoff- the-shelf (COTS) hardware; obsolescence and remaining current. Recent improvements, current status, and emerging issues will be presented. Numerous proposals for NSTX upgrades have been made that will extend the performance and operating lifetime of NSTX. In light of this, a collective strategy for improving NSTX's collaborative software model for a new decade of operations will be examined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Research Framework for Demonstrating Benefits of Advanced Control Room Technologies

Control Room modernization is an important part of life extension for the existing light water reactor fleet. None of the 99 currently operating commercial nuclear power plants in the U.S. has completed a full-scale control room modernization to date. A full-scale modernization might, for example, entail replacement of all analog panels with digital workstations. Such modernizations have been undertaken successfully in upgrades in Europe and Asia, but the U.S. has yet to undertake a control room upgrade of this magnitude. Instead, nuclear power plant main control rooms for the existing commercial reactor fleet remain significantly analog, with only limited digital modernizations. Previous research under the U.S. Department of Energy’s Light Water Reactor Sustainability Program has helped establish a systematic process for control room upgrades that support the transition to a hybrid control. While the guidance developed to date helps streamline the process of modernization and reduce costs and uncertainty associated with introducing digital control technologies into an existing control room, these upgrades do not achieve the full potential of newer technologies that might otherwise enhance plant and operator performance. The aim of the control room benefits research presented here is to identify previously overlooked benefits of modernization, identify candidate technologies that may facilitate such benefits, and demonstrate these technologies through human factors research. This report serves as an outline for planned research on the benefits of greater modernization in the main control rooms of nuclear power plants.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A dual wavelength imaging system for plasma-surface interaction studies on the National Spherical Torus Experiment Upgrade

A two-channel spectral imaging system based on a charge injection device radiation-hardened intensified camera was built for studies of plasma-surface interactions on divertor plasma facing components in the National Spherical Torus Experiment Upgrade (NSTX-U) tokamak. By means of commercially available mechanically referenced optical components, the two-wavelength setup images the light from the plasma, relayed by a fiber optic bundle, at two different wavelengths side-by-side on the same detector. Remotely controlled filter wheels are used for narrow bandpass and neutral density filters on each optical path allowing for simultaneous imaging of emission at wavelengths differing in brightness up to 3 orders of magnitude. Applications on NSTX-U will include the measurement of impurity influxes in the lower divertor strike point region and the imaging of plasma-material interaction on the head of the surface analysis probe MAPP (Material Analysis and Particle Probe). The diagnostic setup and initial results from its application on the lithium tokamak experiment are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Guidelines for lighting of plants in controlled environments

These guidelines for lighting of plants, established by the organizing committee, provided a focus for the discussions at the workshop. The guidelines served as a basis for discussion amongst the workshop attendees and led to a number of recommendations that were recorded by the session chairpersons. The organizing committee indicated they would incorporate the recommendations and suggestions into a revised set of guidelines for additional discussion. It was understood that these guidelines will not be standards and will require upgrading and modifications as lamps and equipment become available and as new insights are obtained on plants' response to light. Revised draft guidelines are included as Tables 1 and 2 that have been developed by the organizing committee following the suggestions obtained at the workshop. The guidelines for growth chambers are in Table 1 and guideines for greenhouses are given in Table 2. These have been distributed to the participants who indicated a willingness to review proposals that were developed. It is hoped that these proposals will lead to the development of guidelines that will have general acceptance by plant scientists.

Dietzer, Gerald↗

In-Situ Gamma Radiation Mapping Device - 19353

The SRNL developed GrayQb{sup TM} is a passive, low cost gamma radiation mapping device which uses a tungsten pinhole and a phosphor storage plate (PSP) to generate images. Presently, the device requires retrieval to extract images off the PSP using an external scanner. In partnership with Los Alamos National Lab (LANL), SRNL has developed an in-situ GrayQb{sup TM} radiation mapping device eliminating the need to remove the radiation sensitive phosphor storage plate (PSP) from the device for scanning between exposures. By incorporating a customized version of the LANL patented MiniMax camera-based PSP reader system into the GrayQb{sup TM} housing, the exposed PSP can now be read in-situ and digitally transmitted to a remote computer for viewing. In-situ imaging is a valuable addition to GrayQb{sup TM} because of the reduced need of personnel interaction which mitigates risk as well as the option for multiple images being acquired during one deployment. Upgrades implemented which allow for in-situ imaging to be performed include using the tungsten pinhole, a PSP, red LEDs, a blue light filter, and a commercial off the shelf (COTS) color camera. The images are transmitted wirelessly to an external computer. This presentation will discuss the selection, characteristics, and testing of the camera-based PSP reading system, improved PSP materials, and the results/performance of the upgraded GrayQb{sup TM} device. Testing has been performed with simulated radiation exposures as well as A-241 and Cs-137 button sources. These upgrades and tests have been performed over a 12-month period and this presentation will be a summary and conclusion to this year long project. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

APART/PADE analytical evaluation of the diffuse infrared background experiment for NASA's cosmic background explorer

The stray light performance of NASA's Diffuse Infrared Background Experiment (DIRBE) has been calculated using the APART/PADE code. That code has been upgraded to handle off-axis optical systems such as DIRBE. Under observing conditions, sunlight is attenuated by 21 to 29 orders-of-magnitude; uniform diffuse illumination, by 6 to 9 orders of magnitude. The sunlight is attenuated by multiple diffraction at an external sun shield and by a forebaffle at the entrance to the DIRBE. Stray light is nearly a linear function of the Bidirectional Reflectance Distribution Function (BRDF) of the primary mirror at all wavelengths - or it can be made to be so by reducing the size of the field defining stop from 0.866 to 0.7 degrees square. For uniform diffuse illumination, half of the stray radiation comes from within 5 degrees of the center of the field-of-view. Particulate contamination of the primary mirror is expected to be a problem and special polishing and cleaning procedures are recommended - before mirror overcoating and again before flight.

Evans, D. C.↗

Recent Beam Measurements and New Instrumentation at the Advanced Light Source

The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

43 PARTICLE ACCELERATORS↗

RECENT BEAM MEASUREMENTS AND NEW INSTRUMENTATION AT THE ADVANCED LIGHT SOURCE

The Advanced Light Source (ALS) in Berkeley was the first of the soft x-ray third generation light source ever built, and since 1993 has been in continuous and successful operation serving a large community of users in the VUV and soft x-ray community. During these years the storage ring underwent through several important upgrades that allowed maintaining the performance of this veteran facility at the forefront. The ALS beam diagnostics and instrumentation have followed a similar path of innovation and upgrade and nowadays include most of the modem and last generation devices and technologies that are commercially available and used in the recently constructed third generation light sources. In this paper we will not focus on such already widely known systems, but we will concentrate our effort in the description of some measurements techniques, instrumentation and diagnostic systems specifically developed at the ALS and used during the last few years.

43 PARTICLE ACCELERATORS↗

On the scattering correction of fast-ion D-alpha signals on NSTX-U

Analysis of fast-ion D-alpha (FIDA) data on National Spherical Torus Experiment-Upgrade (NSTX-U) shows that the cold Dα line contaminates the FIDA baseline. The scattered light is comparable to the FIDA emission. A scattering correction is required to extract the FIDA signal. Two methods that relate the scattered light contamination to the intensity of the cold Dα line are employed. Here, one method uses laboratory measurements with a calibration lamp; the other method uses data acquired during plasma operation and singular value decomposition analysis. Finally, after correction, both the FIDA spectra and spatial profile are in better agreement with theoretical predictions.

47 OTHER INSTRUMENTATION↗

Characterizing the plasma-induced thermal loads on a 200 kW light-ion helicon plasma source via infra-red thermography

The light-ion helicon plasma source of the Proto-MPEX linear plasma device has been recently upgraded to enable pulsed (0.5–1 s) operation up to 200 kW. The main objective of this work is to report on the plasma-induced surface heat fluxes incident on the helicon window during high power operation (60–150 kW net power) for the purpose of the design of the upcoming material plasma exposure eXperiment (MPEX). The IR imaging system and associated physics models for the extraction of surface heat fluxes are presented. Furthermore, experimental results demonstrate that the control of the plasma strike point via magnetic flux mapping and the use of dedicated limiters is effective at reducing the heat loads on the dielectric window. Moreover, it is found that the flux mapping must create a gap between the plasma and the dielectric window of at least the plasma radial decay length. Extrapolated to 200 kW net RF power, this mode of operation can reduce the power lost to the dielectric window by 33%. The results presented have direct application to the design of high-powered helicon plasma sources that operate in a steady state. Examples include linear divertor simulators such as MPEX, electric thrusters, negative ion sources for NBI and linear plasma–material interaction test stands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comprehensive comparison of two tracking codes for single-particle dynamics evaluation of a next-generation storage ring light source

Next-generation light sources based on the multibend achromat concept place great reliance on the accuracy of beam dynamics modeling. To ensure the success of such light sources, confirmation of design performance with at least two independent codes is prudent. The APS Upgrade (APS-U) lattice has been designed using the code ELEGANT, which has existing and new features that are needed by the design. Corresponding, independent improvements have recently been made to the accelerator toolbox (AT), in order to permit an independent check of nonlinear dynamics predictions. The new developments include the modeling of combined-function bending magnets with straight geometry and improved fringe field effects of quadrupole magnets. Calculations of linear and nonlinear lattice parameters and particle tracking results were compared, showing remarkable agreement was found between the two independently developed codes. This provides significant confirmation of the feasibility of the APS-U design.

storage ring↗

On the scattering correction of fast-ion D-alpha signal on NSTX-U

Analysis of fast-ion D-alpha (FIDA) data on National Spherical Torus Experiment-Upgrade (NSTX-U) shows that the cold Dα line contaminates the FIDA baseline. The scattered light is comparable to the FIDA emission. A scattering correction is required to extract the FIDA signal. Two methods that relate the scattered light contamination to the intensity of the cold Dα line are employed. One method uses laboratory measurements with a calibration lamp; the other method uses data acquired during plasma operation and singular value decomposition analysis. After correction, both the FIDA spectra and spatial profile are in better agreement with theoretical predictions.

Single value decomposition (SVD)↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot Humid Climate

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30%-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗