Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Artificial intelligence time series forecasting for feed-forward laser stabilization

Laser plasma accelerators, typically operating at 1–10 Hz repetition rates, have the ability to produce high-quality electron beams in compact, all-optical-driven configurations, with the electron beams uniquely suited for a wide variety of accelerator-based applications. However, fluctuations and drifts in the laser delivery to the meter-scaled and below plasma target (the electron beam source) will translate into electron beam source variations that can limit their utility for demanding applications like light sources or linear colliders. Commercially available active feedback laser stabilization systems are intrinsically bandwidth limited due to their integration with multi-inch corrective mirror mounts which minimizes their effectiveness. In this manuscript, we present a Neural Network time series forecaster that can predict laser position fluctuations of the laser delivery to the final target well ahead of a future laser shot. The Root-Mean-Square-Error (RMSE) of the prediction accuracy was < 2 μ m for a 1 / e 2 beam radius of 34 μ m . Our feed-forward approach serves as a first-step in circumventing the bandwidth limitations imposed by the currently available stabilization systems since it allows for mirrors to be moved into position ahead of time to offset the predicted future position drift. This will help advance laser plasma accelerator research by providing greater robustness and stability needed for its applications.

Berger, Curtis↗

Exploration of the polarization angle variability of the Crab Nebula with POLARBEAR and its application to the search for axionlike particles

The Crab Nebula, also known as Tau A, is a polarized astronomical source at millimeter wavelengths. It has been used as a stable light source for polarization angle calibration in millimeter-wave astronomy. However, it is known that its intensity and polarization vary as a function of time at a variety of wavelengths. Thus, it is of interest to verify the stability of the millimeter-wave polarization. If detected, polarization variability may be used to better understand the dynamics of Tau A, and for understanding the validity of Tau A as a calibrator. One intriguing application of such observation is to use it for the search of axionlike particles (ALPs). Ultralight ALPs couple to photons through a Chern-Simons term, and induce a temporal oscillation in the polarization angle of linearly polarized sources. After assessing a number of systematic errors and testing for internal consistency, we evaluate the variability of the polarization angle of the Crab Nebula using 2015 and 2016 observations with the 150 GHz P instrument. We place a median 95% upper bound of polarization oscillation amplitude A < 0.06 5 ° over the oscillation frequencies from 0.75 year − 1 to 0.66 hour − 1 . Assuming that no sources other than ALP are causing Tau A’s polarization angle variation, that the ALP constitutes all the dark matter, and that the ALP field is a stochastic Gaussian field, this bound translates into a median 95% upper bound of ALP-photon coupling g a γ γ < 2.16 × 10 − 12 GeV − 1 × ( m a / 10 − 21 eV ) in the mass range from 9.9 × 10 − 23 eV to 7.7 × 10 − 19 eV . This demonstrates that this type of analysis using bright polarized sources is as competitive as those using the polarization of cosmic microwave background in constraining ALPs. Published by the American Physical Society 2024

Adachi, Shunsuke (ORCID:0000000204007555)↗

In-situ synchrotron X-ray study on microstructure and stress evolutions of electroplated copper upon self-annealing

Background: The self-annealing behavior of electroplated copper (Cu) at room temperature is gaining attention in the microelectronics industry due to its significant impact on reliability issues such as substrate warpage and electrical resistivity. Methods: In this study, in-situ analysis of the microstructure transition and stress relaxation of the electroplated copper upon self-annealing was conducted via synchrotron white X-ray nanodiffraction (beamline 21A, Taiwan Photon Source) and grazing-incidence X-ray diffraction (beamline 17B1, Taiwan Light Source). Significant Findings: Remarkable relaxations of deviatoric stress and absolute strain component along the [002] direction were closely related to the Cu grain growth and crystallographic reorientation at the early stage of selfannealing, and a complete stress/strain relaxation can be achieved with the cessation of microstructure transition. In conclusion, the in-situ synchrotron X-ray studies provided an insight into Cu self-annealing mechanism, offering valuable information for improving Cu interconnect reliability.

Cu Self-annealing↗

Deep learning based x-ray spectrometer for high repetition rate characterization of betatron radiation

Betatron radiation produced from a laser-wakefield accelerator is a broadband, hard x-ray (>1 keV) source that has been used in a variety of applications in medicine, engineering, and fundamental science. Further development and optimization of stable, high repetition rate (HRR) (>1 Hz) betatron sources will provide a means to extend their application base to include single-shot dynamical measurements of ultrafast processes or dense materials. Recent advances in laser technology used in such experiments have enabled increases in shot-rate and system stability, providing improved statistical analysis and detailed parameter scans. However, unique challenges exist at high repetition rate, where data throughput and source optimization are now limited by diagnostic acquisition rates and analysis. Here, we present the development of a machine-learning algorithm for the real-time analysis of betatron radiation. We report on the fielding of this deep learning algorithm for online source characterization at the Institut National de la Recherche Scientifique's Advanced Laser Light Source. By fine-tuning an algorithm originally trained on a fully synthetic dataset using a subset of experimental data, the algorithm can predict the betatron critical energy with a percent error of 7.2 % with a reconstruction time of 1.5 ms, providing a valuable tool for real-time, multi-objective optimization at HRR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray-based technologies in emerging fuel cell research

The workshop titled `X-ray-based technologies in emerging fuel cell research', organized by Vivian Stojanoff from Brookhaven National Laboratory (BNL) and Narayanasami Sukumar from Cornell University/Advanced Photon Source-Northeastern Collaborative Access Team, was a notable segment of the National Synchrotron Light Source II and Center for Functional Nanomaterials Users' Meeting held 13–17 May 2024. This one-day event, on 13 May 2024, at BNL in New York, aimed to bring together researchers, beamline scientists, management and developers to propel fuel cell technology forward using model systems inspired by natural photosynthesis and redox enzymes. Furthermore, this summary encapsulates the key discussions, advancements and future implications of the workshop.

Xray↗

Femtosecond multimodal imaging with a laser-driven X-ray source

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

43 PARTICLE ACCELERATORS↗

Towards quantum telescopes: demonstration of a two-photon interferometer for precision astrometry

Classical optical interferometry requires maintaining live, phase-stable links between telescope stations. This requirement greatly adds to the cost of extending to long baseline separations and limits on baselines will in turn limit the achievable angular resolution. Here we describe a novel type of two-photon interferometer for astrometry, which uses photons from two separate sky sources and does not require an optical link between stations. Such techniques may make large increases in interferometric baselines practical, even by orders of magnitude, with a corresponding improvement in astrometric precision benefiting numerous fields in astrophysics. We tested a benchtop analogue version of the two-source interferometer and unambiguously observe correlated behavior in detections of photon pairs from two thermal light sources, in agreement with theoretical predictions. This work opens new possibilities in future astronomical measurements.

47 OTHER INSTRUMENTATION↗

Adiabatic light guide with S-shaped strips

A light guide is an essential part of many scintillator counters and light collection systems. Our main interest is a light guide for a thin, wide scintillator that has high light transmission while converting the area of the light source to the shape of a photo-detector. Here, we propose a variation of the light guide that avoids a 90° twist of the strips, reduces the length of the light pipe, and reduces the complexity of production. Detailed Monte Carlo simulation studies have been performed for a three-strip S-shaped light-guide system.

47 OTHER INSTRUMENTATION↗

Prospects and applications of on-chip lasers

Abstract Integrated silicon photonics has sparked a significant ramp-up of investment in both academia and industry as a scalable, power-efficient, and eco-friendly solution. At the heart of this platform is the light source, which in itself, has been the focus of research and development extensively. This paper sheds light and conveys our perspective on the current state-of-the-art in different aspects of application-driven on-chip silicon lasers. We tackle this from two perspectives: device-level and system-wide points of view. In the former, the different routes taken in integrating on-chip lasers are explored from different material systems to the chosen integration methodologies. Then, the discussion focus is shifted towards system-wide applications that show great prospects in incorporating photonic integrated circuits (PIC) with on-chip lasers and active devices, namely, optical communications and interconnects, optical phased array-based LiDAR, sensors for chemical and biological analysis, integrated quantum technologies, and finally, optical computing. By leveraging the myriad inherent attractive features of integrated silicon photonics, this paper aims to inspire further development in incorporating PICs with on-chip lasers in, but not limited to, these applications for substantial performance gains, green solutions, and mass production.

Zhou, Zhican↗

Development of Lighting Application Efficacy Measurement Framework

Lighting significantly contributes to electricity consumption in buildings. The most widely used measure of lighting energy efficiency, luminous efficacy, quantifies only the intensity of light generated by light sources, weighted by the spectral sensitivity of the human visual system (i.e., the energy efficiency of individual lighting devices). However, luminous efficacy does not fully address the use of lighting in architectural spaces. To address these limitations, we developed a framework to framework to calculate lighting application efficacy (LAE), the relationship between the electrical power consumed by lighting hardware, and the amount of light that contributes to the visual perception of building occupants. The proposed LAE framework is based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into the eyes of occupants, and the process of visual perception. The project’s primary outputs are a method for measuring lighting application efficacy and a framework for facilitating future research to improve the metric.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Imaging system and method for enhanced visualization of near surface vascular structures

A sub-dermal structure visualization system and method is disclosed. The system may use an illumination module including: a near-infrared (NIR) light source adapted to substantially uniformly illuminate an imaged area including sub-dermal regions thereof with NIR light; and a first optical system including at least one optical element for controlling at least one of spectral and polarization properties of the NIR light prior to illuminating the imaged area. An imaging module rejects unwanted signals from an imaged area while passing desired optical signals that are to be received by an image acquisition module. The desired optical signals can comprise a vein visualization signal to assist in visualizing a vascular structure below a skin layer of a patient.

Demos, Stavros G.↗

X-ray beam monitoring and wavelength calibration using four-beam diffraction

Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All-optical single-shot complete electric field measurement of extreme ultraviolet free electron laser pulses

Recent advances in ultrafast extreme ultraviolet (EUV) and x-ray light sources provide direct access to fundamental time and length scales for biology, chemistry, and materials physics. However, such light pulses are challenging to measure due to the need for femtosecond time resolution at difficult-to-detect wavelengths. Also, single-shot measurements are needed because severe pulse-to-pulse fluctuations are common. Here we demonstrate single-shot, complete field measurements by applying a novel version of frequency resolved optical gating. An EUV free electron laser beam creates a transient grating containing the pulse’s electric field information, which is read out with a 400 nm probe pulse. By varying the time delay between two copies of the EUV pump, rather than between the pump and the probe, we separate the needed coherent wave mixing from the slow incoherent response. Because this approach uses photoionization, it should be applicable from the vacuum ultraviolet to hard x rays.

36 MATERIALS SCIENCE↗

Low voltage AC electroluminescence in silicon MOS capacitors

Low power silicon based light source and detector are attractive for on-chip photonic circuits given their ease of process integration. However, conventional silicon light emitting diodes emit photons with energies near the band edge where the corresponding silicon photodetectors lack responsivity. On the other hand, previously reported hot carrier electroluminescent silicon devices utilizing a reverse biased diode require high operating voltages. Here, we investigate hot carrier electroluminescence in silicon metal–oxide–semiconductor capacitors operating under transient voltage conditions. Further, during each voltage transient, large energy band bending is created at the edge of the source contact, much larger than what is achievable at a steady state. As a result, electrons and holes are injected efficiently from a single source contact into the silicon channel at the corresponding voltage transient, where they subsequently undergo impact ionization and phonon-assisted interband recombination. Notably, we show low voltage operation down to 2.8 V by using a 20 nm thick high-κ gate dielectric. We show further voltage scaling is possible by reducing the gate dielectric thickness, thus presenting a low voltage platform for silicon optoelectronic integrated circuits.

42 ENGINEERING↗

Detector Interface for Streaming, Control, and Open-source integration (DISCO) v1.0.0

This suite consists of a multi-package ecosystem featuring detector emulators, EPICS areaDetector drivers, and remote server frameworks designed for the Advanced Light Source (ALS). Engineered for high-bandwidth devices—including VFCCD, Timepix3, Timepix4, and related pixel detectors—the software simulates hardware, wraps vendor SDKs into remote-callable servers, and integrates with open-source control systems. Key Capabilities: Distributed SDK Architecture: Server packages wrap hardware-specific SDKs, allowing areaDetector drivers to execute remote framework calls. This isolates proprietary libraries from the EPICS IOC, enhancing stability and enabling distributed computing across beamline networks. Device Support: Custom drivers for VFCCD, the Timepix family, and similar sensors optimize the data path from hardware control to high-speed transport. Full-Stack Emulation: Sophisticated emulator packages allow end-to-end pipeline testing and software development without requiring physical hardware or beam time. Integrated Workflows: Supports high-bandwidth streaming for real-time analysis and robust, metadata-rich file-based workflows (e.g., HDF5/NeXus). By standardizing interfaces across heterogeneous hardware, this suite reduces technical debt. It provides the ALS with a scalable, open-source solution to manage massive data rates within a unified control environment.

Mahl, Johannes [Lawrence Berkeley National Laborat↗

Catalytic resonance theory for the kinetic signatures of multiple wavelength photocatalysis

Multi-step surface chemistry promoted with one or two wavelengths of light exhibited distinct kinetic signatures indicative of the light-adsorbate interactions and the number of photon-sensitive elementary steps. In this work, kinetic Monte Carlo simulations identified the kinetic response of general surface mechanisms to variation in the per-site photon flux of one or two wavelengths of incident light. Photocatalytic rates were described via a non-dimensional photon flux, identifying multiple kinetic regimes with unique degrees of rate control. Under photon-controlled kinetic conditions, maximum quantum yield and turnover frequency were obtained under constant illumination, while pulsing of one or more light sources was shown to exhibit slower rates and less efficient photocatalytic promotion due to the inherent dynamic nature of light, which comprises a stream of photons. Simulations provided distinct kinetic signatures in catalytic rates and Arrhenius kinetics for specific light-surface-adsorbate interactions corresponding to photocatalytic promotion of specific steps in surface chemistry.

catalytic resonance↗

Lighting application efficacy: A framework for holistically measuring lighting use in buildings

Lighting consumes significant energy in buildings, but current measurements of lighting efficiency are inadequate in capturing the spatial and temporal effectiveness of light. The most widely used lighting energy efficiency measure, luminous efficacy, quantifies the amount of light generated by individual light sources. While luminous efficacy provides manufacturers and designers with a useful metric for quantifying the energy efficiency of individual lighting devices, it does not fully address the use of lighting in architectural spaces. Instead, application efficacy, the relationship between the electrical power consumed by lighting hardware and the amount of light that contributes to the visual perception of building occupants, must be measured. Here, we propose a framework for calculating lighting application efficacy (LAE) based on the primary pathway of light in architectural settings: the generation and emission of light from a luminaire, the travel of the light throughout the space and into occupants’ eyes, and the process of visual perception. The LAE framework will include the development of computational methods for estimating the proportion of emitted light that is directed to task areas and areas corresponding to occupants’ visual fields using ray-tracing lighting design software. Future modeling and validation work will quantify energy efficiency of buildings.

Durmus, Dorukalp↗