Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Light sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Scaling device for photographic images

A scaling device projects a known optical pattern into the field of view of a camera, which can be employed as a reference scale in a resulting photograph of a remote object, for example. The device comprises an optical beam projector that projects two or more spaced, parallel optical beams onto a surface of a remotely located object to be photographed. The resulting beam spots or lines on the object are spaced from one another by a known, predetermined distance. As a result, the size of other objects or features in the photograph can be determined through comparison of their size to the known distance between the beam spots. Preferably, the device is a small, battery-powered device that can be attached to a camera and employs one or more laser light sources and associated optics to generate the parallel light beams. In a first embodiment of the invention, a single laser light source is employed, but multiple parallel beams are generated thereby through use of beam splitting optics. In another embodiment, multiple individual laser light sources are employed that are mounted in the device parallel to one another to generate the multiple parallel beams.

Rivera, Jorge E.↗

HPE ultralit project (ARPA-E open program 2018) final report 15

The goal of the program was to build a fully integrated optical transceiver with >1 Tb/s and <1.5 pJ/bit operating at 50 ◦ C. Optical transceivers are critical components in high-performance-computers (HPC) and data centers, and the details of their implementation has a big impact on the total power consumption (energy efficiency) of an HPC system. Our proposed transceiver used three key enabling technologies. Firstly, SiGe avalanche photodetectors have record-low sensitivities, meaning that they can reach low bit error rates with very little light input. As a result, we can drive our lasers at a lower drive current, thus saving electrical power. Secondly, we use MOS-based capacitive tuning in our deinterleaver, modulator, and demultiplexer. Capacitive tuning allows for the tuning of photonic elements with zero static power consumption. Thirdly, we use quantum dots as the gain material in our light source. This allows us to efficiently use our light source at temperatures that are typically encountered in an HPCsystem. Our proposed optical transceiver consisted of a quantum dot comb laser as a light source, a booster SOA, MOS-based deinterleavers, MOS based ring modulators, MOS-based ring demultiplexers, and SiGe APDs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Illumination control apparatus for compensating solar light

An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.

Owens, L. J.↗

Light Extinction Tomography for Measurement of Ice Crystals and Other Small Particles

A tomography duct for wind tunnels includes a plurality of light sources and sensors displaced around a support structure. The light sources are cycled and sensor measurements are made from sensors opposite the light sources. Tomographic algorithms are used to determine an extinction map from the sensor measurements. The extinction map provides details about particles in a cross-section of the air flow through the tomography duct.

Bencic, Timothy J.↗

Attitude sensor

A device for controlling the attitude of a spacecraft is described. The device consists of two light sensors on a spacecraft that are mounted beneath a baffle which divides the light from a light source such as the sun or a star. The divided light reflects off of two reflective surfaces onto the two light sensors. When the spacecraft assumes its normal attitude, the baffle divides the light source into two equal parts, causing the two light sensors to produce equal outputs. When the light is equally detected, the stabilizing system is disconnected. Deviations from the normal attitude cause unequal distribution of the light source and energize the stabilizing system.

Newcomb, A. L., Jr.↗

Biosensors for EVA: Improved Instrumentation for Ground-based Studies

During lunar excursions in the EVA suit, real-time measurement of metabolic rate is required to manage consumables and guide activities to ensure safe return to the base. Metabolic rate, or oxygen consumption (VO2), is normally measured from pulmonary parameters but cannot be determined with standard techniques in the oxygen-rich environment of a spacesuit. Our group has developed novel near infrared spectroscopic (NIRS) methods to calculate muscle oxygen saturation (SmO 2), hematocrit, and pH, and we recently demonstrated that we can use our NIRS sensor to measure VO 2 on the leg during cycling. Our NSBRI project has 4 objectives: (1) increase the accuracy of the metabolic rate calculation through improved prediction of stroke volume; (2) investigate the relative contributions of calf and thigh oxygen consumption to metabolic rate calculation for walking and running; (3) demonstrate that the NIRS-based noninvasive metabolic rate methodology is sensitive enough to detect decrement in VO 2 in a space analog; and (4) improve instrumentation to allow testing within a spacesuit. Over the past year we have made progress on all four objectives, but the most significant progress was made in improving the instrumentation. The NIRS system currently in use at JSC is based on fiber optics technology. Optical fiber bundles are used to deliver light from a light source in the monitor to the patient, and light reflected back from the patient s muscle to the monitor for spectroscopic analysis. The fiber optic cables are large and fragile, and there is no way to get them in and out of the test spacesuit used for ground-based studies. With complimentary funding from the US Army, we undertook a complete redesign of the sensor and control electronics to build a novel system small enough to be used within the spacesuit and portable enough to be used by a combat medic. In the new system the filament lamp used in the fiber optic system was replaced with a novel broadband near infrared LED light source. The compact grating spectrometer was replaced with a chip-scale spectrometer. With this new design, the sensor is 4 in 2 in 0.5 in, weighs 60 g, and no fiber optic cables are needed. The sensor, which contains the light source and the spectrometer, is adhered directly to the skin with medical grade adhesive. The sensor can be powered via the USB port of the laptop computer that controls the sensor operation. Alternatively, for studies in the spacesuit, the sensor can be powered by a small battery pack and operated by an ultra-portable hand-held computer. Both the handheld computer and battery pack will easily fit within the PLSS of the test spacesuit. System automation was significantly improved, to add features suggested by our colleagues in the Cardiovascular Laboratory and the NASA JSC Exercise Physiology and Countermeasures Project. The functionality and portability of this system were demonstrated in our UMass laboratory.

Soller, B.↗

Out-of-Focus Alinement of Solar Concentrators

In new alinement technique, no attempt made to simulate infinitely distant light source, and all mirrors left uncovered throughout procedure. Light source placed at distance of 1,650 feet (503 m); other distances used. Alinement of approximately 250 mirror facets of paraboloidal solar concentrator simplified by precalculated images reflected from all facets. Developed for large solar concentrators, technique used with other multiplemirror or multiple-light-source systems for producing specified illuminance patterns.

Argoud, M. J.↗

Spectral quality affects disease development of three pathogens on hydroponically grown plants

Plants were grown under light-emitting diode (LED) arrays with various spectra to determine the effects of light quality on the development of diseases caused by tomato mosaic virus (ToMV) on pepper (Capsicum annuum L.), powdery mildew [Sphaerotheca fuliginea (Schlectend:Fr.) Pollaci] on cucumber (Cucumis sativus L.), and bacterial wilt (Pseudomonas solanacearum Smith) on tomato (Lycopersicon esculentum Mill.). One LED (660) array supplied 99% red light at 660 nm (25 nm bandwidth at half-peak height) and 1% far-red light between 700 to 800 nm. A second LED (660/735) array supplied 83% red light at 660 nm and 17% far-red light at 735 nm (25 nm bandwidth at half-peak height). A third LED (660/BF) array supplied 98% red light at 660 nm, 1% blue light (BF) between 350 to 550 nm, and 1% far-red light between 700 to 800 nm. Control plants were grown under broad-spectrum metal halide (MH) lamps. Plants were grown at a mean photon flux (300 to 800 nm) of 330 micromoles m-2 s-1 under a 12-h day/night photoperiod. Spectral quality affected each pathosystem differently. In the ToMV/pepper pathosystem, disease symptoms developed slower and were less severe in plants grown under light sources that contained blue and UV-A wavelengths (MH and 660/BF treatments) compared to plants grown under light sources that lacked blue and UV-A wavelengths (660 and 660/735 LED arrays). In contrast, the number of colonies per leaf was highest and the mean colony diameters of S. fuliginea on cucumber plants were largest on leaves grown under the MH lamp (highest amount of blue and UV-A light) and least on leaves grown under the 660 LED array (no blue or UV-A light). The addition of far-red irradiation to the primary light source in the 660/735 LED array increased the colony counts per leaf in the S. fuliginea/cucumber pathosystem compared to the red-only (660) LED array. In the P. solanacearum/tomato pathosystem, disease symptoms were less severe in plants grown under the 660 LED array, but the effects of spectral quality on disease development when other wavelengths were included in the light source (MH-, 660/BF-, and 660/735-grown plants) were equivocal. These results demonstrate that spectral quality may be useful as a component of an integrated pest management program for future space-based controlled ecological life support systems.

NASA Center KSC↗

Glancing incidence telescopes for space astronomy

A technique for determining the state of polarization of a light source by evaluating its image at the focus of a glancing telescope is reported. An analysis of the central disc of the diffraction image reveals if the light source is polarized, the plane of polarization, and the degree of polarization. When polarized light is incident at the aperture of a diffraction limited glancing telescope, the central disc of the diffraction pattern takes on an elliptical configuration. This ellipticity is caused by the tendency of the electric vector component in the plane of incidence to be absorbed by the reflecting material. As the state of polarization goes from plane polarized to decreasing degrees of elliptically polarized light, the ellipticity of the central disc goes from a maximum at plane polarization to zero at circular polarization. These curves give a direct relationship between the degree of polarization of a light source and the ellipticity of the central disc for this particular telescope, independent of the light source wavelength.

Alonso, J., Jr.↗

Recent activities of National Synchrotron Light Source-II Insertion Device Group

Insertion Device (ID) Group at the National Synchrotron Light Source-II (NSLS-II) has been involved in the following activities: Installation and maintenance of the HEX-Superconducting Wiggler (SCW), Laboratory Directed Research and Development (LDRD) for SC adaptive gap undulator (AGU), NSLS-II Experimental Tools II & III (NEXT-II & III) project IDs. Improvement of in-vacuum flip coil bench, development of in-vacuum pulsed wire bench and upgrade of a regular flip coil bench. Development of rotating coil bench for the lattice magnets for future upgrade. This paper describes the specifics of each activity.

47 OTHER INSTRUMENTATION↗

Compact imaging system using a co-linear, high-intensity LED illumination unit to minimize window reflections for background-oriented schlieren, shadowgraph, photogrammetry and machine vision measurements

One aspect of the present disclosure is an imaging system including an optical sensor defining an optical axis. The system further includes a light source. The system may include an optical beam splitter, and may also include an optional diffusing lens that may be configured to diffuse and/or collimate light from the light source and direct light exiting the diffusing lens to the optical beam splitter. The optical beam splitter is configured to direct light from the light source along the optical axis of the optical sensor.

Bathel, Brett F.↗

Thumb-actuated two-axis controller

A two axis joystick controller is described. It produces at least one output signal in relation to pivotal displacement of a member with respect to an intersection of the two axes. The member is pivotally movable on a support with respect to the two axes. The support has a centrally disposed aperture. A light source is mounted on the pivotally movable member above the aperture to direct light through the aperture. A light sensor is mounted below the aperture in the support at the intersection of the two axes to receive the light from the light source directed through the aperture. The light sensor produces at least one output signal related to a location on the sensor at which the light from the light source strikes the sensor.

Hollow, R. H.↗

The resolution of point sources of light as analyzed by quantum detection theory

The resolvability of point sources of incoherent light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

Helstrom, C. W.↗

An interferometer having fused optical fibers, and apparatus and method using the interferometer

An interferometer includes a first optical fiber coupled to a second optical fiber by fusing. At a fused portion, the first and second optical fibers are cut to expose respective cores. The cut or fused end of the first and second optical fibers is arranged to oppose a diaphragm or surface against which a physical phenomenon such as pressure or stress, is applied. In a first embodiment, a source light which is generally single-mode monochromatic, coherent light, is input to the first optical fiber and by evanescence, effectively crosses to the second optical fiber at the fused portion. Source light from the second optical fiber is reflected by the diaphragm or surface, and received at the second optical fiber to generate an output light which has an intensity which depends upon interference of reference light based on the source light, and the reflected light reflected from the diaphragm or surface. The intensity of the output light represents a positional relationship or displacement between the interferometer and the diaphragm or surface.

Hellbaum, Richard F.↗

NSUF FY 2024 Annual Report: Microscopy and Characterization Suite (MaCS) and National Synchrotron Light Source-II (NSLS-II)

The Microscopy and Characterization Suite (MaCS) laboratory at the Center for Advanced Energy Studies (CAES) and the National Synchrotron Light Source-II (NSLS-II) at Brookhaven National Laboratory (BNL) partner with the Nuclear Science User Facilities (NSUF). This partnership provides funding that allows researchers to access these facilities at no cost for studying irradiation effects on nuclear fuels and materials. Through NSUF, both MaCS and NSLS-II support post-irradiation examination (PIE) and irradiation activities for NSUF Rapid Turnaround Experiments (RTE) and NSUF Consolidated Innovative Nuclear Research (CINR) awards. This report details the work completed at these facilities for NSUF competitively selected awards during fiscal year 2024.

99 GENERAL AND MISCELLANEOUS↗

Diffuse-Illumination Systems for Growing Plants

Agriculture in both terrestrial and space-controlled environments relies heavily on artificial illumination for efficient photosynthesis. Plant-growth illumination systems require high photon flux in the spectral range corresponding with plant photosynthetic active radiation (PAR) (400 700 nm), high spatial uniformity to promote uniform growth, and high energy efficiency to minimize electricity usage. The proposed plant-growth system takes advantage of the highly diffuse reflective surfaces on the interior of a sphere, hemisphere, or other nearly enclosed structure that is coated with highly reflective materials. This type of surface and structure uniformly mixes discrete light sources to produce highly uniform illumination. Multiple reflections from within the domelike structures are exploited to obtain diffuse illumination, which promotes the efficient reuse of photons that have not yet been absorbed by plants. The highly reflective surfaces encourage only the plant tissue (placed inside the sphere or enclosure) to absorb the light. Discrete light sources, such as light emitting diodes (LEDs), are typically used because of their high efficiency, wavelength selection, and electronically dimmable properties. The light sources are arranged to minimize shadowing and to improve uniformity. Different wavelengths of LEDs (typically blue, green, and red) are used for photosynthesis. Wavelengths outside the PAR range can be added for plant diagnostics or for growth regulation

May, George↗

Synchronization of video recording and laser pulses including background light suppression

An apparatus for and a method of triggering a pulsed light source, in particular a laser light source, for predictable capture of the source by video equipment. A frame synchronization signal is derived from the video signal of a camera to trigger the laser and position the resulting laser light pulse in the appropriate field of the video frame and during the opening of the electronic shutter, if such shutter is included in the camera. Positioning of the laser pulse in the proper video field allows, after recording, for the viewing of the laser light image with a video monitor using the pause mode on a standard cassette-type VCR. This invention also allows for fine positioning of the laser pulse to fall within the electronic shutter opening. For cameras with externally controllable electronic shutters, the invention provides for background light suppression by increasing shutter speed during the frame in which the laser light image is captured. This results in the laser light appearing in one frame in which the background scene is suppressed with the laser light being uneffected, while in all other frames, the shutter speed is slower, allowing for the normal recording of the background scene. This invention also allows for arbitrary (manual or external) triggering of the laser with full video synchronization and background light suppression.

Kalshoven, Jr., James E.↗

Resolution of point sources of light as analyzed by quantum detection theory.

The resolvability of point sources of incoherent thermal light is analyzed by quantum detection theory in terms of two hypothesis-testing problems. In the first, the observer must decide whether there are two sources of equal radiant power at given locations, or whether there is only one source of twice the power located midway between them. In the second problem, either one, but not both, of two point sources is radiating, and the observer must decide which it is. The decisions are based on optimum processing of the electromagnetic field at the aperture of an optical instrument. In both problems the density operators of the field under the two hypotheses do not commute. The error probabilities, determined as functions of the separation of the points and the mean number of received photons, characterize the ultimate resolvability of the sources.

Helstrom, C. W.↗