At least 289 records · Page 16

Amplified spontaneous emission from europium-based molecular complexes coupled to photonic crystal cavities

Rare-earth ion-based materials bear many remarkable optical properties that render them highly appealing for lighting and quantum-related applications. However, their small oscillator strength and weak emission often pose limitations. Here, in this work, we synthesize and couple Eu(III)-based molecular complexes to nanobeam photonic crystals supporting air modes. A reasonable spatial overlap between the molecular complexes and cavity modes leads to an average spontaneous emission coupling efficiency of 0.19. Our pump power-dependent photoluminescence measurements evidence amplified spontaneous emission from the molecular complexes with an amplification threshold as low as 4.4 W/cm 2 , likely benefiting from the efficient coupling. These findings suggest that integrating rare-earth ion-based molecular complexes with photonic structures could be a viable approach for regulating their emission characteristics for particular applications.

36 MATERIALS SCIENCE↗

High-sensitivity, high-speed continuous imaging system

A continuous imaging system for recording low levels of light typically extending over small distances with high-frame rates and with a large number of frames is described. Photodiode pixels disposed in an array having a chosen geometry, each pixel having a dedicated amplifier, analog-to-digital convertor, and memory, provide parallel operation of the system. When combined with a plurality of scintillators responsive to a selected source of radiation, in a scintillator array, the light from each scintillator being directed to a single corresponding photodiode in close proximity or lens-coupled thereto, embodiments of the present imaging system may provide images of x-ray, gamma ray, proton, and neutron sources with high efficiency.

36 MATERIALS SCIENCE↗

Compact, portable, laser induced fluorescence diagnostic for laboratory plasma sources

As diagnostic groups are increasingly called upon to participate in experimental campaigns at remote facilities, there is a need to develop portable versions of plasma diagnostic systems. One such diagnostic is laser induced fluorescence (LIF). Here, we describe a portable LIF apparatus that eliminates the need for an optical table, beam splitters, and an optical chopper. All of the light exiting the laser system is coupled through optical fibers to the experiment and housekeeping diagnostics. Here, the collected light is coupled through an optical fiber as well. A key feature is modulation of the tapered amplifier current instead of physical modulation of the laser output. Using this portable LIF system, measurements of ion temperature, ion flow, and relative metastable ion density are reported for two different remote experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-rays put molecules into a spin

The past decade has witnessed the emergence of a new X-ray light source technology that has been under development for some decades: the so-called self-amplified spontaneous emission-based free-electron laser (FEL). Furthermore, such lasers provide pulses with durations from just below 1 fs (10 –15 s) to over 100 fs and with energies from a few microjoules to a few millijoules, permitting the study of, for example, nonlinear optical effects (1), ultrafast processes (2), coherent diffractive imaging of biological systems such as protein crystals (3, 4), and mimivirus (5). After the opening of the first extreme-UV to soft X-ray user facility, namely FLASH in the Deutsches Elektronen-Synchrotron at Hamburg, Germany (6), a number of other machines covering the extreme-UV (FERMI FEL-1, DALIAN), soft X-ray (FERMI FEL-2, FLASH1/FLASH2), and hard X-ray spectral ranges (LCLS, PAL-XFEL, SACLA, and XFEL) have been opened to users from a wide range of scientific and engineering disciplines.

74 ATOMIC AND MOLECULAR PHYSICS↗

Discovery of extreme, roughly daily superflares on the recurrent nova V2487 Oph

ABSTRACT V2487 Oph is a recurrent nova with detected eruptions in 1900 and 1998. Startlingly, V2487 Oph shows flares, called ‘Superflares’, with up to 1.10 mag amplitude, fast rises of under one-minute, always with an initial impulsive spike followed by a roughly exponential tail, typically one-hour durations, and with random event times averaging once-per-day. The typical flare energy E is over 1038 erg, while the yearly energy budget is 1041 erg. V2487 Oph Superflares obey three relations; the number distribution of flare energies scales as E−2.34 ± 0.35, the waiting time from one flare to the next is proportional to E of the first event, and flare durations scale as E0.44 ± 0.03. Scenarios involving gravitational energy and nuclear energy fail to satisfy the three relations. The magnetic energy scenario, however, can explain all three relations. This scenario has magnetic field lines above the disc being twisted and amplified by the motions of their footprints, with magnetic reconnection releasing energy that comes out as Superflare light. This exact mechanism is already well known to occur in white light solar flares, in ordinary M-type flare stars, and in the many Superflare stars observed all across the H-R diagram. Superflares on Superflare stars have rise times, light-curve shapes, and durations that are very similar to those on V2487 Oph. So we conclude that the V2487 Oph Superflares are caused by large-scale magnetic reconnection. V2487 Oph is now the most extreme Superflare star, exhibiting the largest known flare energy (1.6 × 1039 erg) and the fastest occurrence rate.

Schaefer, Bradley E.↗

Depolarization self-compensation in high-power lasers enabled by a mid-cavity quartz rotator

Depolarization from thermal stress remains a major limitation in high-average-power laser amplifiers, often addressed by complex, costly active methods or by using magneto-optical effects to restore the polarization. We demonstrate a passive polarization self-compensation technique using a quartz rotator in a relay-imaged, multi-pass amplifier geometry. A detailed theoretical framework is presented and validated experimentally, showing a 47 × reduction in depolarized light in a relay-imaged 4-pass cavity. This approach employs a high-damage-threshold, reciprocal material and avoids the use of polarizers or active controls, thereby simplifying system design and reducing costs. Scalability is discussed for realistic inertial fusion energy driver designs, including effectiveness for broadband lasers and thick gain media.

Batysta, František [Lawrence Livermore National La↗

Ionization-Based Optical Structures for the Control of Short-Pulse Lasers (Abbreviated LDRD Report)

The intensity of light from the highest-power lasers is limited by the size of the optics required to amplify, compress, transport, and focus a laser beam. Indeed, optics damage puts strict constraints on the laser energy density that solid optics can sustain; this leads to enormous optics sizes and limits the maximum intensity that these lasers can achieve. In this project we investigated new types of diffractive optics based on mixtures of neutral gas and plasmas. The basic idea is to interfere laser beams in a gas near the ionization threshold, so that plasma is created in the constructive interference regions (i.e., the “bright” fringes of the interference pattern) while the destructive interference regions remain a neutral gas. The resulting refractive index modulation, due to the different indices in gas vs. plasma, effectively turns such structures into diffractive optics elements. We proposed several new types of optics based on this general concept: i) reflection gratings, which can act as mirrors of “pulse cleaners” to eliminate laser pre-pulse; ii) transmission gratings, as part of a new type of pulse compression scheme with the potential to achieve laser intensities orders of magnitude above what is currently feasible using solid-state optics; and iii) holographic lenses, to focus high-power lasers. We conducted laboratory experiments which demonstrated high efficiency reflection gratings, paving the way for practical applications of our new concepts.

47 OTHER INSTRUMENTATION↗

Solar cell angular position transducer

An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object.

Sandford, M. C.↗

Nd:YLF laser for airborne/spaceborne laser ranging

In order to meet the need for light weight, long lifetime, efficient, short pulse lasers, a diode-pumped, Nd:YLF oscillator and regenerative amplifier is being developed. The anticipated output is 20 mJ per 10 picosecond pulse, running at a repetition rate of 40 Hz. The fundamental wavelength is at 1047 nm. The oscillator is pumped by a single laser diode bar and mode locked using an electro-optic, intra-cavity phase modulator. The output from the oscillator is injected as a seed into the regenerative amplifier. The regenerative amplifier laser crystal is optically pumped by two 60W quasi-cw laser diode bars. Each diode is collimated using a custom designed micro-lens bar. The injected 10 ps pulse from the oscillator is kept circulating within the regenerative amplifier until this nanojoule level seed pulse is amplified to 2-3 millijoules. At this point the pulse is ejected and sent on to a more standard single pass amplifier where the energy is boosted to 20 mJ. The footprint of the entire laser (oscillator-regenerative amplifier-amplifier) will fit on a 3 by 4 ft. optical pallet.

Dallas, Joseph L.↗

New Gear Transmission Error Measurement System Designed

The prime source of vibration and noise in a gear system is the transmission error between the meshing gears. Transmission error is caused by manufacturing inaccuracy, mounting errors, and elastic deflections under load. Gear designers often attempt to compensate for transmission error by modifying gear teeth. This is done traditionally by a rough "rule of thumb" or more recently under the guidance of an analytical code. In order for a designer to have confidence in a code, the code must be validated through experiment. NASA Glenn Research Center contracted with the Design Unit of the University of Newcastle in England for a system to measure the transmission error of spur and helical test gears in the NASA Gear Noise Rig. The new system measures transmission error optically by means of light beams directed by lenses and prisms through gratings mounted on the gear shafts. The amount of light that passes through both gratings is directly proportional to the transmission error of the gears. A photodetector circuit converts the light to an analog electrical signal. To increase accuracy and reduce "noise" due to transverse vibration, there are parallel light paths at the top and bottom of the gears. The two signals are subtracted via differential amplifiers in the electronics package. The output of the system is 40 mV/mm, giving a resolution in the time domain of better than 0.1 mm, and discrimination in the frequency domain of better than 0.01 mm. The new system will be used to validate gear analytical codes and to investigate mechanisms that produce vibration and noise in parallel axis gears.

Oswald, Fred B.↗

Eliminating Crystals in Non-Oxide Optical Fiber Preforms and Optical Fibers

Non ]oxide fiber optics such as heavy metal fluoride and chalcogenide glasses are extensively used in infrared transmitting applications such as communication systems, chemical sensors, and laser fiber guides for cutting, welding and medical surgery. The addition of rare earths such as erbium, enable these materials to be used as fiber laser and amplifiers. Some of these glasses however are very susceptible to crystallization. Even small crystals can lead to light scatter and a high attenuation coefficient, limiting their usefulness. Previously two research teams found that microgravity suppressed crystallization in heavy metal fluoride glasses. Looking for a less expensive method to suppress crystallization, ground based research was performed utilizing an axial magnetic field. The experiments revealed identical results to those obtained via microgravity processing. This research then led to a patented process for eliminating crystals in optical fiber preforms and the resulting optical fibers. In this paper, the microgravity results will be reviewed as well as patents and papers relating to the use of magnetic fields in various material and glass processing applications. Finally our patent to eliminate crystals in non ]oxide glasses utilizing a magnetic field will be detailed.

Tucker, Dennis S.↗

Generation and homodyne detection of continuous-variable entangled optical beams with a large wavelength difference

We present a scheme for generating and homodyne detecting of continuous-variable entanglement of bright optical beams with a large wavelength difference by utilizing an optical parametric oscillator (OPO) and an optical parametric amplifier (OPA) simultaneously. Entangled optical beams at 0.8 and 1.5 {mu}m are generated from the OPA; the seed beams injected in the OPA as well as the local oscillators at the two wavelengths needed for homodyne detection are provided by the OPO. The entangler is a ring resonator involving a second-order nonlinear crystal that is pumped from two opposite directions. In one direction the pump power is above the oscillation threshold and the optical nonlinear resonator operates as an OPO. In the other direction the pump power is below the threshold and it operates as a phase-sensitive frequency nondegenerate optical parametric amplifier. Our scheme combines the advantages of both OPO and OPA quantum optical devices and opens another avenue for preparation and homodyne detection of high quality bright entangled light with a large wavelength difference.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimal gas cooling with minimal aero-opticaldistortion for next generation high-average-power lasers (Progress report, Year 2)

Next-generation lasers that combine high-peak-power ultrashort pulses with high repetition rates have the potential to efficiently deliver the high-average-power outputs required for inertial fusion energy generation, laser-based particle acceleration, and to generate compact secondary x- and 𝛾-ray radiation sources, among others. The combination of long gain length with high surface-to-volume ratio to remove residual heat makes gas-cooled multi-slab amplifier heads an inherently aperture- and average power scalable technology that enables this new class of solid-state lasers, and their thermal management becomes the most pressing technical challenge. As the index-of refraction depends on the gas density, heat removal from the slab surfaces unavoidably entails scattering of propagated light from regions of high temperature fluctuations. The requirement to maximize convective heat extraction from the gain medium under the constraint of minimum optical aberration of the beam renders amplifier slab cooling a technological challenge at the intersection of aero-optics, fluid-mechanics and heat transfer. The goal of this research is to leverage computational fluid dynamics and aero optics simulations of different levels of fidelity to devise a numerical modeling and optimization framework for gas-cooled multi-slab amplifiers. The project will be conducted in close collaboration with the Advanced Photon Technologies Group at Lawrence Livermore National Laboratory, where a gas-cooled test stand for laser materials and thermal management structures will be developed and installed. The final goal of the collaborative effort is to manufacture and benchmark a physical prototype of an numerically optimized amplifier head design. Measurement data on solid-state and thermo-optical distortions will be used for the validation of the numerical models. The key technical challenge in this multi-objective design problem is that of balancing optimal heat removal with minimal optical distortion. To facilitate computationally efficient design optimization and, at the same time, deepen our basic understanding of the interaction of light with turbulence, a complementary study that combines high and low-fidelity flow simulations and aero-optical models is proposed. Along the lines of these two objectives and solution strategies, the project is organized into two thrusts.

42 ENGINEERING↗

CITIUS: An infrared-extreme ultraviolet light source for fundamental and applied ultrafast science

We present the main features of CITIUS, a new light source for ultrafast science, generating tunable, intense, femtosecond pulses in the spectral range from infrared to extreme ultraviolet (XUV). The XUV pulses (about 10{sup 5}-10{sup 8} photons/pulse in the range 14-80 eV) are produced by laser-induced high-order harmonic generation in gas. This radiation is monochromatized by a time-preserving monochromator, also allowing one to work with high-resolution bandwidth selection. The tunable IR-UV pulses (10{sup 12}-10{sup 15} photons/pulse in the range 0.4-5.6 eV) are generated by an optical parametric amplifier, which is driven by a fraction of the same laser pulse that generates high order harmonics. The IR-UV and XUV pulses follow different optical paths and are eventually recombined on the sample for pump-probe experiments. We also present the results of two pump-probe experiments: with the first one, we fully characterized the temporal duration of harmonic pulses in the time-preserving configuration; with the second one, we demonstrated the possibility of using CITIUS for selective investigation of the ultra-fast dynamics of different elements in a magnetic compound.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectroscopic measurement of ion temperature and ion velocity distributions in the flux-coil generated FRC

One aim of the flux-coil generated field reversed configuration at Tri Alpha Energy (TAE) is to establish the plasma where the ion rotational energy is greater than the ion thermal energy. To verify this, an optical diagnostic was developed to simultaneously measure the Doppler velocity-shift and line-broadening using a 0.75 m, 1800 groves/mm, spectrometer. The output spectrum is magnified and imaged onto a 16-channel photomultiplier tube (PMT) array. The individual PMT outputs are coupled to high-gain, high-frequency, transimpedance amplifiers, providing fast-time response. The Doppler spectroscopy measurements, along with a survey spectrometer and photodiode-light detector, form a suite of diagnostics that provide insights into the time evolution of the plasma-ion distribution and current when accelerated by an azimuthal-electric field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LOCAL TWO-DIMENSIONAL PARTICLE-IN-CELL SIMULATIONS OF THE COLLISIONLESS MAGNETOROTATIONAL INSTABILITY

The magnetorotational instability (MRI) is a crucial mechanism of angular momentum transport in a variety of astrophysical accretion disks. In systems accreting at well below the Eddington rate, such as the central black hole in the Milky Way (Sgr A*), the plasma in the disk is essentially collisionless. We present a nonlinear study of the collisionless MRI using first-principles particle-in-cell plasma simulations. We focus on local two-dimensional (axisymmetric) simulations, deferring more realistic three-dimensional simulations to future work. For simulations with net vertical magnetic flux, the MRI continuously amplifies the magnetic field, B, until the Alfven velocity, v{sub A} , is comparable to the speed of light, c (independent of the initial value of v{sub A} /c). This is consistent with the lack of saturation of MRI channel modes in analogous axisymmetric MHD simulations. The amplification of the magnetic field by the MRI generates a significant pressure anisotropy in the plasma (with the pressure perpendicular to B being larger than the parallel pressure). We find that this pressure anisotropy in turn excites mirror modes and that the volume-averaged pressure anisotropy remains near the threshold for mirror mode excitation. Particle energization is due to both reconnection and viscous heating associated with the pressure anisotropy. Reconnection produces a distinctive power-law component in the energy distribution function of the particles, indicating the likelihood of non-thermal ion and electron acceleration in collisionless accretion disks. This has important implications for interpreting the observed emission-from the radio to the gamma-rays-of systems such as Sgr A*.

79 ASTRONOMY AND ASTROPHYSICS↗

Design and performance of SiPM-based readout of PbF 2 crystals for high-rate, precision timing applications

Here, we have developed a custom amplifier board coupled to a large-format 16-channel Hamamatsu silicon photomultiplier device for use as the light sensor for the electromagnetic calorimeters in the Muon g-2 experiment at Fermilab. The calorimeter absorber is an array of lead-fluoride crystals, which produces short-duration Cherenkov light. The detector sits in the high magnetic field of the muon storage ring. The SiPMs selected, and their accompanying custom electronics, must preserve the short pulse shape, have high quantum efficiency, be non-magnetic, exhibit gain stability under varying rate conditions, and cover a fairly large fraction of the crystal exit surface area. We describe an optimized design that employs the new-generation of thru-silicon via devices. As a result, the performance is documented in a series of bench and beam tests.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗