Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFETIME”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Neutron lifetime from a new evaluation of ultracold neutron storage experiments

An analysis of data on measurements of neutron lifetime is presented. The new most accurate result of the measurement of neutron lifetime [Phys. Lett. B 605, 72 (2005)]878.5{+-}0.8 s, differs from the world average value [Phys. Lett. B 667, 1 (2008)]885.7{+-}0.8 s, by 6.5 standard deviations. In this connection an analysis and Monte Carlo simulation of experiments [Phys. Lett. B 483, 15 (2000)] and [Phys. Rev. Lett. 63, 593 (1989)] is carried out. Systematic errors of about -6 s are found in each of the experiments. A summary table of neutron lifetime measurements after corrections and additions is given. A new world average value for neutron lifetime, 879.9{+-}0.9 s, is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetimes of low-lying excited states in Kr 50 36 86

Background: The evolution of nuclear magic numbers at extremes of isospin is a topic at the forefront of contemporary nuclear physics. N = 50 is a prime example, with increasing experimental data coming to light on potentially doubly magic Sn 100 and Ni 78 at the proton-rich and proton-deficient extremes, respectively; however, experimental discrepancies exist in the data for less exotic systems. Purpose: In Kr 86 the B ( E 2 ; 2 1 + → 0 1 + ) value—a key indicator of shell evolution—has been experimentally determined by two different methodologies, with the results deviating by 3 σ . Here, we report on a new high-precision measurement of this value, as well as the first measured lifetimes and hence transition strengths for the 2 2 + and 3 ( 2 ) - states in the nucleus. Methods: The Doppler-shift attenuation method was implemented using the TRIUMF-ISAC γ -ray escape-suppressed spectrometer (TIGRESS) γ -ray spectrometer and the TIGRESS integrated plunger device. High-statistics Monte Carlo simulations were utilized to extract lifetimes in accordance with state-of-the-art methodologies. Results: Lifetimes of τ ( 2 1 + ) = 336 ± 4 (stat.) ± 20 (sys.) fs, τ ( 2 2 + ) = 263 ± 9 (stat.) ± 19 (sys.) fs, and τ ( 3 ( 2 ) - ) = 73 ± 6 (stat.) ± 32 (sys.) fs were extracted. This yields a transition strength for the first-excited state of B ( E 2 ; 2 1 + → 0 1 + ) = 259 ± 3 (stat.) ± 16 (sys.) e 2 fm 4 . Conclusions: Finally, the measured lifetime disagrees with the previous Doppler-shift attenuation method measurement by more than 3 σ , while agreeing well with a previous value extracted from Coulomb excitation. The newly extracted B ( E 2 ; 2 1 + → 0 1 + ) value indicates a more significant reduction in the N = 50 isotones approaching Z = 40 .

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Colloquium: The neutron lifetime

The decay of the free neutron into a proton, electron, and antineutrino is the prototype semileptonic weak decay and is the simplest example of nuclear beta decay. It played a key role in the early Universe as it determined the ratio of neutrons to protons during the era of primordial light element nucleosynthesis. Neutron decay is physically related to important processes in solar physics and neutrino detection. The mean neutron lifetime has been the subject of more than 20 major experiments done, using a variety of methods, between 1950 and the present. The most precise recent measurements have stated accuracies approaching 0.1%, but are not in good agreement as they differ by as much as 5{sigma} using quoted uncertainties. The history of neutron lifetime measurements is reviewed and the different methods used are described, giving important examples of each. The discrepancies and some systematic issues in the experiments that may be responsible are discussed, and it is shown by means of global averages that the neutron lifetime is likely to lie in the range of 880-884 s. Plans and prospects for future experiments are considered that will address these systematic issues and improve our knowledge of the neutron lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

AYUSH: A Technique for Extending Lifetime of SRAM-NVM Hybrid Caches

Recently, researchers have explored way-based hybrid SRAM-NVM (non-volatile memory) last level caches (LLCs) to bring the best of SRAM and NVM together. However, the limited write endurance of NVMs restricts the lifetime of these hybrid caches. We present AYUSH, a technique to enhance the lifetime of hybrid caches, which works by using data-migration to preferentially use SRAM for storing frequently-reused data. Microarchitectural simulations confirm that AYUSH achieves larger improvement in lifetime than a previous technique and also maintains performance and energy efficiency. For single, dual and quad-core workloads, the average increase in cache lifetime with AYUSH is 6.90X, 24.06X and 47.62X, respectively.

device lifetime↗

New analysis of neutron-lifetime experiments

The experiments on measuring the neutron lifetime have been analyzed. The newest and most exactly measured neutron lifetime [Phys. Lett. B 605, 72 (2005)] (878.5 {+-} 0.8 s) differs from the world average value [Phys. Lett. B 667, 1 (2008)] (885.7 {+-} 0.8 s) by 6.5 standard deviations. In this context, an analysis and Monte Carlo simulation of the experiments [Phys. Lett. B 483, 15 (2000)] and [Phys. Rev. Lett. 63, 593 (1989)] have been performed. Systematic errors of about -6 s are found in both experiments. A table with the results of measuring the neutron lifetime is presented with corrections and additions. The new world average value for the neutron lifetime is found to be 880.0 {+-} 0.9 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of annealing on the nonequilibrium carrier lifetime in GaAs grown at low temperatures

GaAs samples grown by molecular-beam epitaxy at low (230 Degree-Sign C) temperatures are investigated. One of the samples is subjected to aftergrowth annealing at 600 Degree-Sign C. Using an unconventional pump-probe scheme for measuring the dynamic variation in the light refractive index, the nonequilibrium charge-carrier lifetime (275 {+-} 30 fs before annealing) is determined. Such a short carrier lifetime in the unannealed material is due to the high concentration of point defects, mainly As{sub Ga} antisite defects. According to X-ray diffraction and steady-state optical absorption data, the As{sub Ga} concentration in the samples is 3 Multiplication-Sign 10{sup 19} cm{sup -3}, which corresponds to an arsenic excess of 0.26 at %. Upon annealing at 600 Degree-Sign C, the superstoichiometric As defects self-organize and form As nanoinclusions in the GaAs crystal matrix. It is shown that in this case the nonequilibrium charge-carrier lifetime increases to 452 {+-} 5 fs. This lifetime is apparently ensured by the capture of non-equilibrium charge carriers at metal As nanoinclusions.

36 MATERIALS SCIENCE↗

Extension of the radiative lifetime of Wannier-Mott excitons in semiconductor nanoclusters

The purpose of the study is to calculate the radiative lifetime of Wannier-Mott excitons in three-dimensional potential wells formed of direct-gap narrow-gap semiconductor nanoclusters in wide-gap semiconductors and assumed to be large compared to the exciton radius. Calculations are carried out for the InAs/GaAs heterosystem. It is shown that, as the nanocluster dimensions are reduced to values on the order of the exciton radius, the exciton radiative lifetime becomes several times longer compared to that in a homogeneous semiconductor. The increase in the radiative lifetime is more pronounced at low temperatures. Thus, it is established that the placement of Wannier-Mott excitons into direct-gap semiconductor nanoclusters, whose dimensions are of the order of the exciton radius, can be used for considerable extension of the exciton radiative lifetime.

36 MATERIALS SCIENCE↗

Two-component molecular tagging velocimetry utilizing NO fluorescence lifetime and NO2 photodissociation techniques in an underexpanded jet flowfield

We report the application of molecular tagging velocimetry (MTV) toward two-component velocimetry as demonstrated in an underexpanded free jet flowfield. Two variants of the MTV technique are presented: 1) electronic excitation of seeded nitric oxide (NO) with gated fluorescence imaging (fluorescence lifetime) and 2) photodissociation of seeded NO2 followed by NO fluorescence imaging (NO2 photodissociation). The seeded NO fluorescence lifetime technique is advantageous in low-quenching, high-velocity flowfields, while the photodissociation technique is useful in high-quenching environments, and either high- or low-velocity flowfields due to long lifetime of the NO photoproduct. Both techniques are viable for single-shot measurements, with determined root mean squared results for streamwise and radial velocities of {approx}5%. This study represents the first known application of MTV utilizing either the fluorescence lifetime or the photodissociation technique toward two-component velocity mapping in a gaseous flowfield. Methods for increasing the spatial resolution to be comparable to particle-based tracking techniques are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CONSTRAINING THE LIFETIME AND OPENING ANGLE OF QUASARS USING FLUORESCENT Ly α EMISSION: THE CASE OF Q0420–388

A toy model is developed to understand how the spatial distribution of fluorescent emitters in the vicinity of bright quasars could be affected by the geometry of the quasar bi-conical radiation field and by its lifetime. The model is then applied to the distribution of high-equivalent-width Ly α emitters (with rest-frame equivalent widths above 100 Å, threshold used in, e.g., Trainor and Steidel) identified in a deep narrow-band 36 × 36 arcmin{sup 2} image centered on the luminous quasar Q0420–388. These emitters are found near the edge of the field and show some evidence of an azimuthal asymmetry on the sky of the type expected if the quasar is radiating in a bipolar cone. If these sources are being fluorescently illuminated by the quasar, the two most distant objects require a lifetime of at least 15 Myr for an opening angle of 60° or more, increasing to more than 40 Myr if the opening angle is reduced to a minimum of 30°. However, some other expected signatures of boosted fluorescence are not seen at the current survey limits, e.g., a fall off in Ly α brightness, or equivalent width, with distance. Furthermore, to have most of the Ly α emission of the two distant sources to be fluorescently boosted would require the quasar to have been significantly brighter in the past. This suggests that these particular sources may not be fluorescent, invalidating the above lifetime constraints. This would cast doubt on the use of this relatively low equivalent width threshold and thus also on the lifetime analysis in Trainor and Steidel.

79 ASTRONOMY AND ASTROPHYSICS↗

Effect of Increased Water Vapor Levels on TBC Lifetime

To investigate the effect of increased water vapor levels on thermal barrier coating (TBC) lifetime, furnace cycle tests were performed at 1150 C in air with 10 vol.% water vapor (similar to natural gas combustion) and 90 vol.%. Either Pt diffusion or Pt-modified aluminide bond coatings were applied to specimens from the same batch of a commercial second-generation single-crystal superalloy and commercial vapor-deposited yttria-stabilized zirconia (YSZ) top coats were applied. Three coatings of each type were furnace cycled to failure to compare the average lifetimes obtained in dry O{sub 2}, using the same superalloy batch and coating types. Average lifetimes with Pt diffusion coatings were unaffected by the addition of water vapor. In contrast, the average lifetime of Pt-modified aluminide coatings was reduced by more than 50% with 10% water vapor but only slightly reduced by 90% water vapor. Based on roughness measurements from similar specimens without a YSZ coating, the addition of 10% water vapor increased the rate of coating roughening more than 90% water vapor. Qualitatively, the amount of {beta}-phase depletion in the coatings exposed in 10% water vapor did not appear to be accelerated.

03 NATURAL GAS↗

Lifetime studies of 130nm nMOS transistors intended for long-duration, cryogenic high-energy physics experiments.

Future neutrino physics experiments intend to use unprecedented volumes of liquid argon to fill a time projection chamber in an underground facility. To increase performance, integrated readout electronics should work inside the cryostat. Due to the scale and cost associated with evacuating and filling the cryostat, the electronics will be unserviceable for the duration of the experiment. Therefore, the lifetimes of these circuits must be well in excess of 20 years. The principle mechanism for lifetime degradation of MOSFET devices and circuits operating at cryogenic temperatures is via hot carrier degradation. Choosing a process technology that is, as much as possible, immune to such degradation and developing design techniques to avoid exposure to such damage are the goals. This requires careful investigation and a basic understanding of the mechanisms that underlie hot carrier degradation and the secondary effects they cause in circuits. In this work, commercially available 130nm nMOS transistors operating at cryogenic temperatures are investigated. The results show that the difference in lifetime for room temperature operation and cryogenic operation for this process are not great and the lifetimes at both 300K and at 77K can be projected to more than 20 years at the nominal voltage (1.5V) for this technology.

43 PARTICLE ACCELERATORS↗

Prospects for a new cold neutron beam measurement of theneutron lifetime

In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for a new cold neutron beam measurement of the neutron lifetime

In the most accurate cold neutron beam determination of the neutron lifetime based on the absolute counting of decay protons, the largest uncertainty was attributed to the absolute determination of the capture flux of the cold neutron beam. Currently an experimental effort is underway at the National Institute of Standards and Technology (NIST) that will significantly reduce this contribution to the uncertainty in the lifetime determination. The next largest source of uncertainty is the determination of the absolute count rate of decay protons, which contributes to the experimental uncertainty approximately at the 1 s level. Experience with the recent neutron radiative decay experiment, which used the neutron lifetime apparatus, has provided valuable insights into ways to reduce other uncertainties. In addition, the cold neutron fluence rate at NIST is presently 1.5 times greater than in the 2003 measurement, and there is the prospect for a significantly higher rate with the new guide hall expansion. This paper discusses an approach for achieving a determination of the neutron lifetime with an accuracy of approximately 1 s.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Colloquium: The neutron lifetime

The decay of the free neutron into a proton, electron, and antineutrino is the prototype semileptonic weak decay and is the simplest example of nuclear beta decay. It played a key role in the early Universe as it determined the ratio of neutrons to protons during the era of primordial light element nucleosynthesis. Neutron decay is physically related to important processes in solar physics and neutrino detection. The mean neutron lifetime has been the subject of more than 20 major experiments done, using a variety of methods, between 1950 and the present. The most precise recent measurements have stated accuracies approaching 0.1%, but are not in good agreement as they differ by as much as 5 sigma using quoted uncertainties. The history of neutron lifetime measurements is reviewed and the different methods used are described, giving important examples of each. The discrepancies and some systematic issues in the experiments that may be responsible are discussed, and it is shown by means of global averages that the neutron lifetime is likely to lie in the range of 880 884 s. Plans and prospects for future experiments are considered that will address these systematic issues and improve our knowledge of the neutron lifetime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetime of the Highly Efficient H- Ion Sources

Factors limiting the operating lifetime of Compact Surface Plasma Sources (CSPS) are analyzed and possible treatments for lifetime enhancement are considered. Noiseless discharges with lower gas and cesium densities are produced in experiments with modified discharge cells. With these discharge cells it is possible to increase the emission aperture and extract the same beam with a lower discharge current and with correspondingly increased source lifetime. A design of an advanced CSPS is presented. Optimization of the discharge cells in a Penning H{sup -} ion source is a viable method for increasing the phase space of the stable region for noiseless discharge production. With this method, cesium usage would be decreased, potentially resulting in longer source lifetimes.

43 PARTICLE ACCELERATORS↗

Effects of Reactive Power on Photovoltaic Inverter Reliability and Lifetime

For predicting the reliability and lifetime of Photovoltaic (PV) inverters, thermal cycling is considered the most important stressors in the inverter system. To realize this, a detailed electrothermal model of the PV inverter was developed along with the controllers. The model was verified by developing an in-house inverter, which was placed inside a thermal chamber to verify the losses and temperature rise within the system at various temperatures. After the verification of the model, a reduced order model of the inverter was implemented which can translate the mission profile of ambient temperature and solar irradiance into load profile of junction temperatures of the switches. The estimated junction temperature data was used to identify the reliability indices and predict the useful lifetime of the inverter system. After developing the models to predict useful lifetime of the system, the impact of reactive power on the overall reliability of the system was studied. Experiments show that lifetime and reliability of the inverter decreases as the operating power factor decreases from unity. The results are presented and discussed here.

14 SOLAR ENERGY↗

Dominance of Exciton Lifetime in the Stability of Phosphorescent Dyes

Organic light-emitting devices (OLEDs) are widely used for mobile displays, but the relatively short lifetime of blue OLEDs remains a challenge in many applications. Typically, instability is viewed as a material-specific chemical degradation problem. It is known to be alleviated by reducing the operating current or otherwise decreasing the exciton density. Here we have shown that this view is incomplete. For archetypical phosphorescent materials, it is observed that the dependence of photostability on the triplet exciton lifetime follows a cubic power law, steeper than its dependence on exciton density. It is demonstrated that the triplet exciton lifetime not only determines the energy stored within an OLED, it also determines the loss in luminescence by controlling the yield of quenching by defects. The dominant role of the triplet exciton lifetime suggests that the stability of the best OLED materials can be significantly improved via rapid extraction of the energy stored in triplet excitons.

36 MATERIALS SCIENCE↗

Exceeding 200 ns Lifetimes in Polycrystalline CdTe Solar Cells

CdTe photovoltaics has achieved one of the lowest levelized costs of electricity among all energy sources. However, for decades, carrier lifetimes have been inferior to those of other prevalent solar cell materials. This quality has inhibited common methods to improve solar cell efficiency such as back-surface fields, electron reflectors, or bifacial solar cells. In this work, a significant increase in carrier lifetime to values exceeding 200 ns in fully functional CdTe solar cells is demonstrated. The increased lifetime is achieved by large CdSeTe grains at the absorber/emitter interface, intragrain passivation in the absorber layer, and chemical passivation by forming nanoscale oxidized tellurium species at the transparent conducting oxide interface. The carrier lifetime is correlated to the open-circuit voltage and enables paths for back-surface manipulation and novel cell architectures to further improve CdTe photovoltaic performance.

14 SOLAR ENERGY↗