Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LIFE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A method to estimate the fractional fat volume within a ROI of a breast biopsy for WAXS applications: Animal tissue evaluation

Purpose: To develop a method to estimate the mean fractional volume of fat (ν{sup ¯}{sub fat}) within a region of interest (ROI) of a tissue sample for wide-angle x-ray scatter (WAXS) applications. A scatter signal from the ROI was obtained and use of ν{sup ¯}{sub fat} in a WAXS fat subtraction model provided a way to estimate the differential linear scattering coefficient μ{sub s} of the remaining fatless tissue. Methods: The efficacy of the method was tested using animal tissue from a local butcher shop. Formalin fixed samples, 5 mm in diameter 4 mm thick, were prepared. The two main tissue types were fat and meat (fibrous). Pure as well as composite samples consisting of a mixture of the two tissue types were analyzed. For the latter samples, ν{sub fat} for the tissue columns of interest were extracted from corresponding pixels in CCD digital x-ray images using a calibration curve. The means ν{sup ¯}{sub fat} were then calculated for use in a WAXS fat subtraction model. For the WAXS measurements, the samples were interrogated with a 2.7 mm diameter 50 kV beam and the 6° scattered photons were detected with a CdTe detector subtending a solid angle of 7.75 × 10{sup −5} sr. Using the scatter spectrum, an estimate of the incident spectrum, and a scatter model, μ{sub s} was determined for the tissue in the ROI. For the composite samples, a WAXS fat subtraction model was used to estimate the μ{sub s} of the fibrous tissue in the ROI. This signal was compared to μ{sub s} of fibrous tissue obtained using a pure fibrous sample. Results: For chicken and beef composites, ν{sup ¯}{sub fat}=0.33±0.05 and 0.32 ± 0.05, respectively. The subtractions of these fat components from the WAXS composite signals provided estimates of μ{sub s} for chicken and beef fibrous tissue. The differences between the estimates and μ{sub s} of fibrous obtained with a pure sample were calculated as a function of the momentum transfer x. A t-test showed that the mean of the differences did not vary from zero in a statistically significant way thereby validating the methods. Conclusions: The methodology to estimate ν{sup ¯}{sub fat} in a ROI of a tissue sample via CCD x-ray imaging was quantitatively accurate. The WAXS fat subtraction model allowed μ{sub s} of fibrous tissue to be obtained from a ROI which had some fat. The fat estimation method coupled with the WAXS models can be used to compare μ{sub s} coefficients of fibroglandular and cancerous breast tissue.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New levels and a lifetime measurement in {sup 204}Tl

The {sup 205}Tl(n,2n{gamma}) reaction was used to populate excited states in {sup 204}Tl. The {gamma}-ray detection was accomplished with the GEANIE spectrometer, a Compton suppressed array of 26 Ge detectors. An energetic beam of neutrons was provided by the pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility. The time-of-flight technique was used to determine the incident neutron energies. {gamma}-ray excitation functions were determined from incident neutron energy of 1 MeV up to E{sub n}=25 MeV. The level scheme of {sup 204}Tl was enriched and the partial level scheme and nuclear structure above the previously known 7{sup +} isomer at 1104-keV excitation energy were established for the first time up to E{sub x}{approx}2.3 MeV. The high-spin part of the level scheme exhibits striking similarities to that of the neighboring {sup 202}Tl isotope, suggesting similarities in the underlying nuclear structure. The half-life of the 7{sup +} isomer was measured with a more precise result (T{sub 1/2}=60.7{+-}1.2 {mu}s), in agreement with literature values. A lower limit for the excitation energy of the {pi}h{sub 11/2}{nu}i{sub 13/2} structure with J{sup {pi}}=12{sup -} is proposed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Background Suppression Using Pulse Shape Analysis with a BEGe Detector for Neutrinoless Double Beta Decay Search with GERDA

A pulse shape analysis for distinguishing between double beta decay-like interactions and multiple-scattered photons was performed for the first time using a BEGe-type detector. This discrimination method is included in the research and development for the second phase of the GERDA experiment, since active background suppression techniques are necessary to reach sensitivity for the {sup 76}Ge neutrinoless double beta decay half life of >10{sup 26} years. A suppression of backgrounds in the energy region of interest around the {sup 76}Ge Q{sub {beta}}{sub {beta}} = 2039 keV is demonstrated, with (0.93{+-}0.08)% survival probability for events from {sup 60}Co, (21{+-}3)% for {sup 226}Ra, and (40{+-}2)% for {sup 228}Th. This performance is achieved with (89{+-}1)% acceptance of {sup 228}Th double escape events, which are analogous to double beta decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measurement of the 136 Xe two-neutrino double-β-decay half-life via direct background subtraction in NEXT

Here, we report a measurement of the half-life of the 136 Xe two-neutrino double-β decay performed with a novel direct-background-subtraction technique. The analysis relies on the data collected with the NEXT-White detector operated with 136 Xe-enriched and 136 Xe-depleted xenon, as well as on the topology of double-electron tracks. With a fiducial mass of only 3.5 kg of Xe, a half-life of 2.34$_{-0.46}^{+0.80}$(stat)$_{-0.17}^{+0.30}$(sys)×10 21 yr is derived from the background-subtracted energy spectrum. The presented technique demonstrates the feasibility of unique background-model-independent neutrinoless double-β-decay searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results on nucleon life-time from the Kolar gold field experiment

The KGF nucleon decay experiment has been in operation since October 1980 with a 140 ton calorimetric detector at a depth of 2.3 Km underground. The detector comprises 34 layers of proportional counters arranged in an orthogonal geometry with 12 mm thick iron plates in between successive layers. The proportional counters are made up of square (10 x 10 square centimeters) iron plates of wall thickness 2.3 mm. Each of the 1600 counters is instrumented to provide data on ionization, DE/dx and arrival time. The visible energy of a particle is determined to an accuracy of approximately 20% from the ionization and range of its track. The end point ionization of a stopping track provides the direction of motion as well as the nature of the particle (mu/pi,k,p). Decay of mu is recorded with an overall efficiency of only 20% in view of the thickness of 13 g/square centimeters between successive layers.

Krishnaswamy, M. R.↗

Identification of Leakage Spectra from Neutron Activation in Glass/Cherenkov Detectors - Paper 96

Oak Ridge National Laboratory has developed a new detector system concept that can be deployed in major US cities to identify the leakage spectrum of a nuclear weapon detonation. The detector is based on a small piece of glass that has been doped with an element that has a high activation cross section and creates a radioactive activation product with a reasonable length half-life. The decay of the activation product(s) after exposure creates Cherenkov light which can propagate to a photomultiplier and can be turned into a count-rate signal. The signal from each glass in each detector in a city can be individually analyzed to determine the amount of activation products produced in the initial exposure. Several activation products can be determined in a single glass if the half-lives are not the same. With a known source location and a detailed 3D model of a city, neutron transport simulations can be made by using a library of known sources to predict the activation amounts each source would have made in the glass detectors. A simple comparison of the measured activation amounts and the predicted activation amounts can identify the source spectrum contained in the library that is the best match. Choosing dopants with a large range in the threshold energy for the activation reactions can help to differentiate the spectra in the library. The method of matching the measured activation amounts to the predicted activation amounts to identify the source spectrum is similar to the analysis used for the passive Activation Foil Integrated Detector System (AFIDS), also developed at Oak Ridge National Laboratory. In AFIDS, wires or foils of known mass and isotopic composition are deployed before and then collected after exposure. Counting gammas in a nearby laboratory determines the activation amounts. The glass/Cherenkov system is active - it uses a battery-powered detector to count flashes of Cherenkov light and to communicate its count rates to a remote location for further analysis. Work has been performed in several areas, including glass making, automated detection and communication systems and software tools for analysis of the signal and source spectrum identification. Bell and Boatner have developed phosphate glasses that incorporate elements with high capture cross sections, and Hayward has simulated the response with Geant4 and measured the response with isotopic gamma sources. This paper will focus on the software tools for determining the activation amounts from the Cherenkov count-rate signal and finding the best matching source spectrum. A test problem in an urban environment is used to demonstrate the potential of a spectrum identification system using neutron activation. The analysis methods developed to identify the neutron leakage spectra from Cherenkov light given off by neutron activation in doped glasses work well. The calculation used to unfold the count-rate information into the number of actual activation products uses robust algorithms that can also compute associated uncertainties. These uncertainties and the known uncertainties of the glass tube material compositions are incorporated into the matching analysis to determine which of the source spectra in the library best matches the measured activation data. Any measurement method used to identify a neutron source spectrum relies at some point on a comparison against known sources; no identification method is definitive. Detection systems measure some physical aspect of the source, not its serial number. Many systems measure the physical aspect to determine that the source has some property, and then leave it to experts to determine which potential sources share that property. The analysis system presented here incorporates the comparison into the analysis itself. The statistical tests show which of the known library sources match the measured data the best and whether that match is a good match. If the best match still does not fit the measured data well (a very high χ{sup 2} value), that indicates the true source is not one of the sources in the library. This is still valuable information for decision makers. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Millisecond Isomer Lifetime Measurements at LANSCE

New half-life measurements have been made of the millisecond isomers {sup 71m}Ge, {sup 114m2}I, {sup 208m}Bi, {sup 88m1}Y, {sup 88m2}Y, and {sup 75m}As populated in neutron-induced reactions. These measurements were made using the unique time structure of the LANSCE/WNR neutron source, by observing the γ-ray decays of the isomers during the time between the LANSCE proton macropulses. Two different LANSCE proton beam time structures were used. The GEANIE array of HPGe detectors was used to detect the γ-ray decays.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Active Activation Diagnostics for High Energy X-ray and Neutron Measurements

Nuclear activation is a vital tool for diagnosing the properties of high-energy particles and photons. We investigate several potential reactions and suitable activation materials that could be used to simultaneously measure both neutrons and high-energy bremsstrahlung x-rays using one detector. Such a diagnostic would be valuable and practical for several facilities capable of creating such high-energy neutrons and x-rays. Laser-generated sources, such as NIF(-ARC) or Omega(-EP), have been shown to be capable of creating high-energy x-rays via high-intensity laser interactions and neutrons via DT fusion reactions. Furthermore, current laser technology is driving the demand for higher repetition rate diagnostics, hence we further constrain reaction/activation selections to accommodate high-repletion rate experiments. Our investigation will concentrate on identifying potential short half-life activation materials associated with high-energy x-ray reactions that could be incorporated into the existing realtime neutron activation detectors (RTNADs), an array of 48 activation detectors positioned around the NIF target chamber used to measure the DT neutron yield isotropy. We have identified two materials, gold and neodymium, that appear to be the best candidates to complement the RTNADs, by adding a new high-energy x-ray measurement capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first bolometric experiment searching for neutrinoless double beta decay that has been able to reach the 1-ton scale. In this talk we present the neutrinoless doube beta decay results of CUORE from examining a total TeO 2 exposure of 86.3 kg yr, characterized by an effective energy resolution of 7.7 keV FWHM and a background in the region of interest of 0.014 counts/(keV kg yr). In this physics run, CUORE placed a lower limit on the decay half-life of 130 Te > 1.3 × 10 25 yr (90% C.L.). We then discuss the additional improvements in the detector performance achieved in 2018 and the latest update on the evaluation of the background budget.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prenatal dichlorodiphenyldichloroethylene (DDE) exposure and child growth during the first year of life

Background: Due to its long-term persistence in the environment and its ability to cross the placental barrier, prenatal p,p Prime -dichlorodiphenyldichloroethene (DDE) exposure continues to be a public health concern. This study aimed to evaluate the association between prenatal DDE exposure and child growth, at birth and during the first year of life. Methods: 253 pregnant women were recruited between January 2001 and June 2005 in a prospective cohort in Morelos, Mexico. Serum levels of DDE were measured during each trimester of pregnancy by gas chromatography with an electron capture detector. Using the generalized mixed-effects models, the association between DDE and child growth parameters (weight-for-age, length-for-age, weight-for-length, BMI-for-age and head circumference-for-age Z-scores) from birth to 1 year of age was assessed. Maternal dietary intake was considered as covariable among others. Results: DDE levels were 6.3{+-}2.8 ng/mL (first trimester), 6.6{+-}2.9 ng/mL (second trimester), and 7.6{+-}2.9 ng/mL (third trimester). After adjusting for potential confounder variables, no significant associations were observed with prenatal DDE exposure and each of the selected parameters. Conclusions: Our results show no evidence of an association between prenatal DDE exposure and child growth during the first year of life.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Decay Spectroscopy of {sup 45}Fe

In an experiment performed at the NSCL/MSU A1900 separator the decay of {sup 45}Fe was investigated in detail. Two-proton radioactivity channel was clearly identified and for the first time the correlations between two protons emitted from the nuclear ground state were determined. The comparison with a theoretical model indicates the genuine three-body character of this decay and sheds light on the shell structure of this exotic nucleus. The {beta} decay channels of {sup 45}Fe, followed by one-, two-, and three-proton emission, were also identified. The {beta}3p decay channel was observed for the first time. The half-life of {sup 45}Fe was found to be 2.6{+-}0.2 ms and the 2p decay branching ratio is 70{+-}4%. In the experiment a new type of gaseous detector has been applied in which a technique of digital imaging was used to record tracks of charged particles.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-E-T-200: IBA ProteusOne Compact Proton Therapy System Radiation Survey Results

Purpose: This study summarizes the results of an initial radiation survey of the Willis-Knighton Cancer Center in Shreveport, Louisiana. The facility houses an IBA ProteusOne compact single room proton therapy unit coupled with a C230 cyclotron that operates at a maximum energy of 230 MeV. Methods: A calibrated survey meter was used for the photon measurements to obtain reliable results. A neutron detector was used as the measuring instrument for neutrons. The locations of the survey and measurements were planned carefully in order to get a proper evaluation of the facility shielding configuration. The walls, ceiling, vault entrance, and the adjacent environment were each surveyed with suitable measurement instruments. A total of 22 locations were chosen for radiation survey. Dose equivalent values were calculated for both the photon and the neutron radiation using measured data. Results: All measured dose values are presented in millisievert per year. The highest dose measured at the vault entrance is 0.34 mSv/year. A dedicated shielding door was not present at the time of the measurement. The vault entrance area is considered as a controlled area. The shielding design goals are not to exceed 5 mSv/year for the controlled area and 1 mSv/year the uncontrolled area. The total combined neutron and photon dose equivalent values were found to be compliant with the Louisiana Department of Environmental Quality radiation protection regulatory codes. Conclusion: In our efforts to evaluate the radiation levels at the Willis-Knighton Cancer Center proton treatment facility, we have found that all the measured values of the radiation shielding are below the critical radiation limits per year. Since the total dose measured at the vault entrance is below the shielding design goal, a shielding door is not required at this proton treatment vault.

60 APPLIED LIFE SCIENCES↗

Measurements of Short-Lived Isomers from Photofission as a Method of Active Interrogation for Special Nuclear Materials

Isomeric fission products, such as 134m Te (T 1/2 = 164 ns) and 136m Xe (T 1/2 = 2.95 μs), are proposed as a signature of special nuclear materials in active interrogation applications. To test this conjecture, monoenergetic 9, 11, and 13 MeV photons from the HIγS facility are used to induce fission of 235 U, 238 U, and 239 Pu targets. The de-excitation γ rays of the isomers are measured using time-gated spectroscopy with high-purity germanium detectors. The 134m Te and 136m Xe isomers are detected and identified by the energy and decay half-life of their characteristic γ-ray transitions. The ratio of yields for these two signature γ rays, corresponding to 134m Te/( 136m Xe + 136 I), is found to be strongly correlated with the identity of the fissioning nuclei. These results show that fission-product isomers may be used in active interrogation to detect and identify special nuclear materials, even providing information on the isotopic enrichment. In conclusion, the feasibility of an active interrogation scenario using a bremsstrahlung beam is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

OAST Space Theme Workshop. Volume 3: Working group summary. 3: Sensors (E-3). A. Statement. B. Technology needs (form 1). C. Priority assessment (form 2). D. Additional assessment

Developments required to support the space power, SETI, solar system exploration and global services programs are identified. Instrumentation and calibration sensors (rather than scientific) are needed for the space power system. Highly sophisticated receivers for narrowband detection of microwave sensors and sensors for automated stellar cataloging to provide a mapping data base for SETI are needed. Various phases of solar system exploration require large area solid state imaging arrays from UV to IR; a long focal plane telescope; high energy particle detectors; advanced spectrometers; a gravitometer; and atmospheric distanalyzer; sensors for penetrometers; in-situ sensors for surface chemical analysis, life detection, spectroscopic and microscopic analyses of surface soils, and for meteorological measurements. Active and passive multiapplication sensors, advanced multispectral scanners with improved resolution in the UV and IR ranges, and laser techniques for advanced probing and oceanographic characterization will enhance for global services.

Source record↗

The Influence of Smoke Particle Properties and Cabin Characteristics on Smoke Detection in Lunar Gravity

Spacecraft fires pose a threat to the success of future Lunar, Martian, and deep space exploration missions. As NASA plans to return humans to the Moon in the next decade, novel mission requirements will present new fire safety challenges. For example, materials that are fire resistant on Earth are expected to burn under planned habitat conditions (elevated oxygen concentrations and reduced cabin pressure) and partial gravity (0.16g). Optimal smoke detector placement will depend on a combination of buoyant plume velocities, induced by partial gravity, and Environmental Control and Life Support Systems (ECLSS) parameters, including particle filtration rates, supply and return placement within the cabin, and forced air velocities. These ECLSS parameters must also address the need for rapid Lunar dust removal, as Lunar dust exposure poses a risk to crew health and hardware functionality. Here, we present progress toward a computational fluid dynamics model to evaluate smoke transport in a Lunar habitat. Recent work has demonstrated that if air supplies are placed on ceilings and returns on the floor, a buoyant smoke layer at the ceiling may disperse over the order of minutes even under low forced flow conditions. We expand upon these results to examine the influence of different supply and return configurations on smoke plume development. Additionally, we also address differences in the transport of smoke particles and Lunar dust by varying particle parameters like size, density, and shape factor. Finally, we discuss ongoing and future experimental efforts to measure smoke particle properties and transport under partial gravity, elevated oxygen, and reduced pressure conditions.

Claire Fortenberry↗

SU-E-T-202: Comparison of 4D-Measurement-Guided Dose Reconstructions (MGDR) with COMPASS and OCTAVIUS 4D System

Purpose: To cross-validate the MGDR of COMPASS (IBA dosimetry, GmbH, Germany) and OCTAVIUS 4D system (PTW, Freiburg, Germany). Methods: Volumetric-modulated arc plans (5 head-and-neck and 3 prostate) collapsed to 40° gantry on the OCTAVIUS 4D phantom in QA mode on Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on a Elekta Agility linac. This study was divided into two parts: (1) error-free measurements by gantry-mounted EvolutionXX 2D array were reconstructed in COMPASS (IBA dosimetry, GmbH, Germany), and by OCTAVIUS 1500 array in Versoft v6.1 (PTW, Freiburg, Germany) to obtain the 3D doses (COM4D and OCTA4D). COM4D and OCTA4D were compared to the raw measurement (OCTA3D) at the same detector plane for which OCTAVIUS 1500 was perpendicular to 0° gantry axis while the plans were delivered at gantry 40°; (2) beam steering errors of energy (Hump=-2%) and symmetry (2T=+2%) were introduced during the delivery of 5 plans to compare the MGDR doses COM4D-Hump (COM4D-2T), OCTA4D-Hump (OCTA4D-2T), with raw doses OCTA3D-Hump (OCTA3D-2T) and with OCTA3D to assess the error reconstruction and detection ability of MGDR tools. All comparisons used Υ-criteria of 2%(local dose)/2mm and 3%/3mm. Results: Averaged Υ passing rates were 85% and 96% for COM4D,and 94% and 99% for OCTA4D at 2%/2mm and 3%/3mm criteria respectively. For error reconstruction, COM4D-Hump (COM4D-2T) showed 81% (93%) at 2%/2mm and 94% (98%) at 3%/3mm, while OCTA4D-Hump (OCTA4D-2T) showed 96% (96%) at 2%/2mm and 99% (99%) at 3%/3mm. For error detection, OCTA3D doses were compared to COM4D-Hump (COM4D-2T) showing Υ passing rates of 93% (93%) at 2%/2mm and 98% (98%), and to OCTA4D-Hump (OCTA4D -2T) showing 94% (99%) at 2%/2mm and 81% (96%) at 3%/3mm, respectively. Conclusion: OCTAVIUS MGDR showed better agreement to raw measurements in both error- and error-free comparisons. COMPASS MGDR deviated from the raw measurements possibly owing to beam modeling uncertainty.

60 APPLIED LIFE SCIENCES↗

SuperNEMO status

The SuperNEMO experiment aims to reach a sensitivity up to 10{sup 26} years on the half-life of neutrinoless double beta decay. The SuperNEMO project strongly inherits from the previous Nemo3 experiment. It will consist of a ''tracko-calo'' modular detector with at least 100 kg of betabeta isotope. The current status of the main R and D tasks will be presented: enrichment and production of source foils, radiopurity control, tracker and calorimeter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling backgrounds for the majorana demonstrator

The MAJORANA DEMONSTRATOR is a neutrinoless double-beta decay (0?ß ß ) experiment containing ~30 kg of p-type point contact germanium detectors enriched to 88% in 76Ge and ~14 kg of natural germanium detectors. The detectors are housed in two electroformed copper cryostats and surrounded by a graded passive shield with active muon veto. An extensive radioassay campaign was performed prior to installation to insure the use of ultra-clean materials. The DEMONSTRATOR achieved one of the lowest background rates in the region of the 0?ß ß Q-value, 15.7 ± 1.4 cts/(FWHM t y) from the low-background configuration spanning most of the 64.5 kg-yr active exposure. Nevertheless this background rate is a factor of five higher than the projected background rate. This discrepancy arises from an excess of events from the 232Th decay chain. Background model fits aim to understand this deviation from assay-based projections, potentially determine the source(s) of observed backgrounds, and allow a precision measurement of the two-neutrino double-beta decay half-life. The fits agree with earlier simulation studies, which indicate the origin of the 232Th excess is not from a near-detector component and have informed design decisions for the next-generation LEGEND experiment. Recent findings have narrowed the suspected locations for the excess activity, motivating a final simulation and assay campaign to complete the background model.

Haufe, Christopher R.↗