Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LEDs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

LED Lighting in a Performing Arts Center

GATEWAY demonstration report of LED wall washer retrofit lighting at the University of Maryland Clarice Smith Performing Arts Center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LED Lighting in a Performing Arts Building

At the University of Florida in Gainesville, the DOE Solid-State Lighting GATEWAY program evaluated LED architectural and theatrical lighting in four academic/performance-related spaces within the Nadine McGuire Theatre + Dance Pavilion. Due to a wise choice of products and luminaire light distributions, the change brought significant quality improvements including improved controllability and color.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

University of Maryland Wall Washer Retrofit - LED Modules Replace Halogen Lamps in a Performing Arts Center

The University of Maryland (UMD) began retrofitting halogen wall washers in the Clarice Smith Performing Arts Center (CSPAC) in April 2014. The U.S. Department of Energy (DOE) Solid-State Lighting (SSL) GATEWAY program documented this process through the final installation in March 2015, summarized in this report. The wall washers illuminate hallways lining the atrium, providing task illuminance for transitioning between spaces and visual interest to the atrium boundaries. The main goals of the retrofit were to maintain the visual appearance of the space while reducing maintenance costs – energy savings was considered an additional benefit by UMD Facilities Management. UMD Facilities Management is pleased with the results of this retrofit, and continues to initiate LED retrofit projects across the UMD campus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investing in Their Future: Portland’s Purchase and Conversion of an LED Street Lighting System

During the ongoing process of converting its streetlights from high-pressure sodium to LED, the city of Portland, Oregon, purchased a large portion of its street lighting system and encountered a range of issues among the stakeholders. This report identifies some of the challenges involved and discusses how they were addressed, in order to help inform and facilitate future lighting transitions elsewhere.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Tuning the Light in Senior Care: Evaluating a Trial LED Lighting System at the ACC Care Center in Sacramento, CA

The GATEWAY program documented the performance of tunable-white LED lighting systems installed in several spaces within the ACC Care Center, a senior-care facility in Sacramento, CA. The project results included energy savings and improved lighting quality, as well as other possible health-related benefits that may have been attributable, at least in part, to the lighting changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Demonstrations: Tuning Hospital Lighting: Evaluating Tunable LED Lighting at the Swedish Hospital Behavioral Health Unit in Seattle

The GATEWAY program evaluated a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CALiPER Application Summary Report 22: LED MR16 Lamps

An initial sample of 27 LED MR16 lamps and 8 halogen benchmarks underwent photometric testing according to IES LM-79-08. CALiPER Application Summary Report 22 focuses on the initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to the benchmarks and ENERGY STAR qualification thresholds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report Brief: Evaluating Tunable LED Lighting in the Swedish Medical Behavioral Health Unit

Summary of a GATEWAY report evaluation of a tunable LED lighting system installed in the new Swedish Medical Behavioral Health Unit in Seattle that incorporates color-tunable luminaires in common areas, and uses advanced controls for dimming and color tuning, with the goal of providing a better environment for staff and patients. The report reviews the design of the tunable lighting system, summarizes two sets of measurements, and discusses the circadian, energy, and commissioning implications as well as lessons learned from the project.

59 BASIC BIOLOGICAL SCIENCES↗

CALiPER Report 23: Photometric Testing of White Tunable LED Luminaires

This report documents an initial investigation of photometric testing procedures for white-tunable LED luminaires and summarizes the key features of those products. Goals of the study include understanding the amount of testing required to characterize a white-tunable product, and documenting the performance of available color-tunable luminaires that are intended for architectural lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GATEWAY Report: Tuning the Light in Classrooms: Evaluating Trial LED Lighting Systems in Three Classrooms at the Carrollton-Farmers Branch Independent School District in Carrollton, TX

The GATEWAY program evaluated a trial installation of tunable-white LED lighting systems in three classrooms in the Carrollton-Farmers Branch Independent School District in Carrollton, TX. The report provides valuable insights into the use of this technology in a real-world setting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Identification and Mitigation of Droop Mechanism in Gallium Nitride (GaN)-Based Light Emitting Diodes (LEDs) (Final Report)

Many indirect methods are currently used to understand and quantify the efficiency loss mechanisms. Typically, measurement of the amount of optical power emitted vs the electrical power consumed is recorded and analyzed. This type of method relies on the use of fitting a mathematical model to this data and attempt to determine the causes of the various efficiency deficiencies. Our project moves away from this indirect method of analysis and focuses on measuring the electrons which pass through the LED directly. By analyzing the energy distribution of these electrons, it is possible to unambiguously identify certain loss mechanisms which are occurring.

36 MATERIALS SCIENCE↗

An Investigation of LED Street Lighting’s Impact on Sky Glow

A study of the expected contributions to sky glow from converting high-pressure sodium (HPS) street lighting to broader-spectrum (i.e., white light) sources, with specific focus on LEDs, which presents the contributions in a manner relative to HPS baseline conditions. These conditions represent typical conversions in the U.S. and include changes in spectral power distribution, percent uplight, and lumen output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Highly Integrated Modular LED Luminaire

The objective of the program is to build an integrated luminaire that is capable of modular assembly, with improvements in efficiency in the driver and light engine. Best in class LEDs are assumed. The team will include GE Global Research, in partnership with Stanford University. The goal is to build a highly integrated lighting solution that meets the DOE goals in 2020 for luminaire efficacy and enables low cost manufacturing in the United States.

30 DIRECT ENERGY CONVERSION↗

Lighting in Senior Care Centers: Comparing Tunable LED Systems to Conventional Lighting Systems in Four Senior Care Centers

This study was initiated to contribute to evidence-based practices for tunable light-emitting diode (LED) lighting upgrades in the future. The report summarizes Pacific Northwest National Laboratory (PNNL) evaluations of lighting conditions in four senior care centers in Wisconsin including energy savings analysis and non-image forming (NIF) response metric calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Upgrade Package Documentation: LED Lighting, HP-RTU and ASHP-Boiler

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) upgrade measures, or upgrades. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility upgrade applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on an upgrade package of three end-use savings shapes upgrades - Light Emitting Diode (LED) Lighting, Heat Pump Rooftop Unit (RTU) (HP-RTU), and Air-Source Heat Pump (ASHP) Boiler, which we will refer to collectively as the "Interior Lighting and Heat Pump" package. More details on the individual upgrades can be found on the ComStock Measures Documentation page. An upgrade package applies two or more EUSS upgrades to a single building model simulation. Since ComStock is a bottom-up physics-based model, an upgrade package will go beyond aggregating or summing the individual upgrade results and produce novel results by simulating interactions between the upgrades. For example, pairing an envelope upgrade with an electrification upgrade would likely result in higher savings results than the sum of these upgrades individually, and the size of the heating, ventilating, and air conditioning (HVAC) equipment may be reduced if the envelope upgrade reduces the loads significantly.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗