Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Deep Exclusive p 0 Electroproduction Measured in Hall A at Jefferson Lab with the Upgraded CEBAF

Our understanding of the proton's structure in terms of its fundamental degrees of freedom, quarks and gluons, is incomplete. Generalized Parton Distributions (GPDs) can enhance our understanding of the partonic structure of the proton as it includes the correlation between the momentum and transverse position of partons. Exclusive electroproduction of the pion (ep→e'p'π 0 ) is one of the potential channels to access the GPDs. GPDs are defined at the Bjorken limit where the total amplitude can be factorized in a hard scattering of the photon off the quark and a soft part described by the GPDs. At sufficiently high Q 2 , a factorization scheme for exclusive meson production processes exists but only for longitudinally polarized virtual photons. As long as the longitudinally polarized virtual photons dominate the cross-section, we can have factorization and extract the GPDs. But the existing data for π 0 production at low Q 2 and low x B show the dominance of transverse part of the cross-section over the longitudinal one. Some transversity GPD models have found that an effective way to factorize the contribution from transversely polarized virtual photons to explain the dominance of σ T over σ L , shown by existing data. The experiment E12-06-114 ran in experimental Hall A during 2014-2016. The primary goal of this experiment was to measure the DVCS cross-section but the experimental configuration also allows the measurement of deep exclusive π 0 production. Taking advantage of the upgraded CEBAF at Jefferson Lab, we explored the high Bjorken-x (0.60) and high Q 2 regime for the first time. The extracted cross-section terms for π 0 production helps us to test the validity of QCD factorization in our kinematic regime. Our π 0 production results can be used to test and improve the existing models of proton structure. Cross-section results will be presented at two different Q 2 values for fixed x B of 0.60.

Karki, Bishnu↗

Jefferson Lab Virtual Tour

Take a virtual tour of the campus of Thomas Jefferson National Accelerator Facility. You can see inside our two accelerators, three experimental areas, accelerator component fabrication and testing areas, high-performance computing areas and laser labs.

43 PARTICLE ACCELERATORS↗

APEX: A Prime EXperiment at Jefferson Lab

APEX is an experiment at Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, that searches for a new gauge boson (A') with sub-GeV mass and coupling to ordinary matter of g' ~ (10 -6 - 10 -2 )e. Electrons impinge upon a fixed target of high-Z material. An A' is produced via a process analogous to photon bremsstrahlung, decaying to an e + e - pair. A test run was held in July of 2010, covering m A' = 175 to 250 MeV and couplings g'/e > 10{sup -3}. A full run is approved and will cover m A ' ~65 to 525 MeV and g'/e > 2.3 × 10 -4 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Assembly of the MOLLER Toroidal Magnets at Jefferson Lab

The MOLLER experiment at the Thomas Jefferson National Accelerator Facility (JLab) aims to precisely measure the weak interaction between electrons. This experiment leverages the 12 GeV electron beam and will run for three years. A crucial component of MOLLER is a system of five uniquely shaped water-cooled toroidal magnets. These magnets, possessing seven-fold symmetry, are designed to focus particles by separating electrons scattered off hydrogen in a liquid hydrogen target. The five magnets separate electrons scattered off electrons (Møller scattering) and protons (elastic e-p scattering) within target into approximately circular rings at the detector. Here, this paper presents the assembly process for these five toroidal magnets, detailing critical steps including epoxy application, pin insertion, soldering and brazing, coil assembly, and alignment, all performed to meet stringent magnet specifications. Additionally, it discusses challenges encountered during construction and highlights lessons learned, offering insights for future magnet development projects.

Lamont, Joseph [Thomas Jefferson National Accelera↗

APEX: A Prime EXperiment at Jefferson Lab

APEX is an experiment at Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, that searches for a new gauge boson ($A^\prime$) with sub-GeV mass and coupling to ordinary matter of $g^\prime \sim (10^{-6} - 10^{-2}) e$. Electrons impinge upon a fixed target of high-Z material. An $A^\prime$ is produced via a process analogous to photon bremsstrahlung, decaying to an $e^+ e^-$ pair. A test run was held in July of 2010, covering $m_{A^\prime}$ = 175 to 250 MeV and couplings $g^\prime/e \; \textgreater \; 10^{-3}$. A full run is approved and will cover $m_{A^\prime} \sim$ 65 to 525 MeV and $g^\prime/e \; \textgreater \; 2.3 \times10^{-4}$.

Beacham, James↗

APEX: A Prime EXperiment at Jefferson Lab

APEX is an experiment at Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, that searches for a new gauge boson (A' ) with sub-GeV mass and coupling to ordinary matter of g'~ (10{sup -6} - 10{sup -2} )e. Electrons impinge upon a fixed target of high-Z material. An A' is produced via a process analogous to photon bremsstrahlung, decaying to an e +e pair. A test run was held in July of 2010, covering m{sub A'} = 175 to 250 MeV and couplings g'/e > 10{sup -3} . A full run is approved and will cover m{sub A'} 65 to 525 MeV and g'/e > 2.3 x 10{sup -4} .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Design and Manufacture of the Conduction Cooled Torus Coils for the Jefferson Lab 12GeV Upgrade

The design of the 12-GeV torus required the construction of six superconducting coils with a unique geometry required for the experimental needs of Jefferson Laboratory Hall B. Each of these coils consists of 234 turns of copper-stabilized superconducting cable conduction cooled by 4.6 K helium gas. The finished coils are each roughly 2 × 4 × 0.05 m and supported in an aluminum coil case. Because of its geometry, new tooling and manufacturing methods had to be developed for each stage of construction. The tooling was designed and developed while producing a practice coil at Fermi National Laboratory. This paper describes the tooling and manufacturing techniques required to produce the six production coils and two spare coils required by the project. Project status and future plans are also presented.

43 PARTICLE ACCELERATORS↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Electroweak Physics at Jefferson Lab

The Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility provides CW electron beams with high intensity, remarkable stability, and a high degree of polarization. These capabilities offer new and unique opportunities to search for novel particles and forces that would require extension of the standard model. CEBAF is presently undergoing an upgrade that includes doubling the energy of the electron beam to 12 GeV and enhancements to the experimental equipment. This upgraded facility will provide increased capability to address new physics beyond the standard model.

43 PARTICLE ACCELERATORS↗

Nucleon Structure Studies at Jefferson Lab and the Electron Ion Collider

The research programs of Thomas Jefferson Laboratory (JLab) and the future Electron- Ion Collider (EIC) focus on one of the main goals of strong interaction studies : understanding the structure of nucleons in terms of the quarks and gluons composing them. Their structure is encoded in functions such as Generalized Parton Distributions (GPDs), which describe how quarks and gluons’ transverse position and longitudinal momentum are distributed inside nucleons. GPDs allow to obtain three-dimensional pictures of nucleons and to understand some of their fundamental properties, such as their internal pressure or the emergence of their spin from the dynamics of the partons composing them. At JLab and the EIC, electron beams are used to probe nucleons. Measurement of reactions such as Deeply Virtual Compton Scattering (DVCS) allows access to GPDs. The first longitudinally polarized-target experiment of the CLAS12 program at Jlab took place in 2022-2023. Combining polarized electron beams and nucleon targets, this experiment offers unique access to observables that allow the measurement of different types of GPDs. In particular, the DVCS beam- and target-spin asymmetries for protons and neutrons in deuterium will be measured for the first time. They give access to kinds of GPDs that are still poorly known, and the comparison between proton and neutron data will allow the extraction of the flavor dependence of the structure of nucleons. Specific analysis methods have been implemented to work with a polarized nuclear target and are presented in this thesis. These methods allow to obtain preliminary results for the asymmetries, waiting for the complete statistics to be available. In the long term, the experimental program for the EIC has been established with a strong emphasis on the measurement of the structure of nucleons at high energy. Measurements of reactions such as DVCS impose strict requirements on the electromagnetic calorimeter that will allow to measure the energy of the scattered electrons and photons. This calorimeter, which is under development, will be based on scintillating crystals read by Silicon Photomultipliers (SiPMs). A new type of glass-based scintillating material was tested, evaluating the possibilities to meet the technical requirements concerning their light yield and resistance to radiation damage in particular. Several models of SiPMs have been characterized, demonstrating they can operate over the vast energy range necessary to address the physics case at the EIC and providing guidelines for developing their readout electronics.

Pilleux, Noemie↗

Large-Scale Production of Carbon Nanotubes Using the Jefferson Lab Free Electron Laser

We report on our interdisciplinary program to use the Free Electron Laser (FEL) at the Thomas Jefferson National Accelerator Facility (J-Lab) for high-volume pulsed laser vaporization synthesis of carbon nanotubes. Based in part on the funding of from this project, a novel nanotube production system was designed, tested, and patented. Using this new system nanotube production rates over 100 times faster than conventional laser systems were achieved. Analysis of the material produced shows that it is of as high a quality as the standard laser-based materials.

Holloway, Brian C.↗

The Jefferson Lab program: From 6 GeV operations to the 12 GeV upgrade

The Thomas Jefferson National Laboratory and the CEBAF accelerator operated for more than a decade, running a comprehensive scientific program that improved our understanding of the strong interaction. The facility is now moving toward an upgrade of the machine, from 6 to 12 GeV; a new experimental hall will be added and the equipment of the three existing halls will be enhanced. In this contribution some selected results from the rich physics program run at JLab, as well as the prospects for the near future, will be presented.

43 PARTICLE ACCELERATORS↗

An optimized prototype of electromagnetic calorimeter for the SoLID project at Jefferson Lab

A shashlik-type electromagnetic calorimeter will be produced in Hall A of Jefferson Laboratory for the Solenoidal Large Intensity Device (SoLID). Wavelength-shifting (WLS) fibers and clear fibers will be used as the light guide part of the calorimeter. The blue light from scintillators is converted into green light by WLS fibers and is carried out to the back of the calorimeters for readout. Since the magnetic field of SoLID reaches about 1.5 T behind the calorimeters, the design is to use clear fibers to further guide the light out of the solenoid for readout by PMTs. Therefore, it is important to study the perfomance of WLS and clear fibers. This paper describes a comparative test of two different WLS fibers and a light attenuation test for a clear fiber. The results show that the performance of the two WLS fibers is the same under large curvature bending, and that the bending has no effect on the light transmission through the clear fiber. In addition, a comparison test for two fiber end-face reflective materials is also reported. It reveals that the use of silver ink as a reflective material can increase the light yield by 30%. Thereby, an optimized prototype based on the above experimental results was built and the basic performance was tested.

Shen, C.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

High-Gradient Wien Spin Rotators at Jefferson Lab

Nuclear physics experiments performed in the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory (JLab) require spin manipulation of electron beams. Two Wien spin rotators in the injector keV region are essential at CEBAF to establish longitudinal polarization at the end station target, and to flip the polarization direction by ? rad to rule out false asymmetries. In a Wien filter, the homogeneous and independent electric and magnetic fields, along with the velocity vectors of the electrons that traverse it, form a mutually orthogonal system. The magnitude of the electrostatic field, established by biasing two highly-polished electrodes, defines the desired spin angle at the target yet deviates the beam trajectory due to the Lorentz force. The beam trajectory in the Wien is then re-established by adjusting the magnetic field, induced by an electromagnet encasing the device vacuum chamber. This contribution describes the evolution design and high voltage testing of Wien filters for spin manipulation at increased beam energies in the keV injector region, required by high precision parity violation experiments like MOLLER.

Palacios Serrano, G. G.↗

APEX: A Prime EXperiment at Jefferson Lab - Test Run Results and Full Run Plans; Update

APEX is an experiment at Thomas Jefferson National Accelerator Facility (JLab) in Virginia, USA, that searches for a new gauge boson (A') with sub-GeV mass and coupling to ordinary matter of g' ~ (10 -6 - 10⁻²)e. Electrons impinge upon a fixed target of high-Z material. An A' is produced via a process analogous to photon bremsstrahlung, decaying to an e⁺+e⁻ pair. A test run was held in July of 2010, covering m A' = 175 to 250 MeV and couplings g'/e > 10⁻³. A full run is approved and will cover m A' ~ 65 to 525 MeV and g'/e > 2.3 x 10⁻⁴, and is expected to occur sometime in 2016 or 2017.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗