Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverted potentials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Intelligently Partitioned Phasor-EMT Hybrid Simulations of Large-Scale, High-IBR Power Systems

As the penetration level of power electronics-interfaced renewables such as photovoltaics (PV) and wind has surged in modern electric grids, new operational risks caused by the dynamics of those inverter-based resources (IBRs) are emerging in parallel. Lessons learned from various grid events include that the impact of IBRs on system-level grid stability will become prominent along with the increase of renewables and that the short-timescale dynamic impacts of IBRs on grid stability are not fully captured by current commercial dynamic simulation tools [1] [2]. For example, IBRs can be controlled to mitigate those destabilizing interactions, but conventional phasor-domain tools (e.g. PSS/E, PSLF) often cannot capture that; likewise, the existing electromagnetic transient (EMT) simulation tools (e.g. PSCAD, EMTP) can simulate detailed IBR controls, but for large power systems with many IBRs, slow simulation speeds severely impede the ability to study dynamic events [3] [4]. Massively paralleling simulations using high-performance computing (HPC) can help address this, especially now that cloud-based HPC capability is widely available, but today s EMT tools are not HPC-compatible, and parallelization of dynamic simulation solvers is not trivial because each region can dynamically affect the others. Thus, dynamic simulation of grids with very large numbers of IBRs potentially poses a barrier to the ongoing energy transition.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Representing DC-Coupled PV+Battery Hybrids in a Capacity Expansion Model

Recent technology cost and performance improvements and the federal investment tax credit (ITC) have driven growing interest in coupling solar photovoltaic (PV) and battery systems. Combining these technologies into co-located or hybridized PV+battery systems has the potential to lower costs and increase energy output relative to multiple independent systems. In this work, we provide an overview of PV+battery systems and demonstrate methods for incorporating them into NREL’s Regional Energy Deployment System (ReEDS) capacity expansion model. Although the methods are applied to a specific model, we anticipate that the approaches used here can be useful for informing PV+battery method development for other capacity expansion models. The implemented method relies heavily on the native representations of PV and battery technologies; therefore, the focus of this work is on capturing and parameterizing the interactions between them for a configuration in which the PV and battery technologies share a single bi-directional inverter. This work also demonstrates the impacts of including PV+battery systems in the ReEDS optimization for the conterminous United States through 2050. In particular, we perform parametric sensitivities for input assumptions that are uncertain and expected to influence PV+battery deployment levels, including (a) the cost of PV+battery systems relative to independent PV and battery systems, (b) the battery component’s qualification for the ITC, and (c) future cost trajectories for PV and battery systems. We find that PV+battery deployment could occur throughout the conterminous United States if there are cost savings associated with DC coupling PV and battery technologies. If even modest (5%) cost savings can be achieved (through a shared inverter and balance-of-system costs), then approximately one-third of utility-scale PV deployment through 2050 adopts the DC-coupled hybrid configuration, resulting in total PV+battery deployment that exceeds the magnitude of PV+battery projects in U.S. interconnection queues in 2020. If greater cost savings can be achieved through DC coupling (e.g., due to a growing amount of shared balance-of-system costs, reduced financial risk, or modularity) or more rapid cost and performance improvements are realized for PV and battery technologies, then total PV+battery deployment and the share of PV and battery deployment that adopts the hybrid configuration grows (to >50%). In all cases, growing PV+battery deployment primarily displaces independent PV and battery technologies, indicating the strong competition between the hybrid and independent configurations comprising technologies with similar performance characteristics.

14 SOLAR ENERGY↗

Securing Distributed Energy Resource Integration

The penetration of distributed energy resources (DER) is growing at much higher rates than predicted 20 years ago. Far from being used only in residential settings, DER are now installed on distribution and transmission circuits. In this position, they do not have the same properties as traditional generators and are more flexible in many cases. The growing penetration and range of uses for DER motivate the need to reliably and safely integrate them into the grid. Operators must be able to rely on them not only for normal operation, but also during abnormal conditions like black starts or adverse cyber scenarios. To that end, we study the communications, device interfaces, and potential consequences of DER operation under abnormal and adversarial conditions. The weaknesses of communications networks are studied based on the industrial protocols used, and the benefits of security features are examined. The device interfaces are found to be vulnerable to attack based on the requirements in the IEEE-1547 standard for DER interconnection and interoperability, which is expected to be adopted in the next ten years. In addition to exploring the requirements of the standard, we show that these vulnerabilities and others do exist and can be used maliciously in a modern storage system DER. Consequences of these vulnerabilities range from exacerbated grid instability, to simultaneous loss of large portions of DER penetration, to physical damage to inverters or DER themselves and other sensitive equipment. We tie these outcomes to specific attacker actions in an effort to give operators a better threat intelligence view that allows them to prioritize mitigations. Finally, we discuss mitigations that could prevent many of the adversarial scenarios described. Some solutions can be added to existing infrastructure, while others may require longer term planning for grid modernization with consideration for security.

25 ENERGY STORAGE↗

Hybrid Hydraulic-Electric Architecture (HHEA) for Mobile Machines (Final Report)

Traditionally, off-road mobile machines such as excavators and wheel loaders are primarily powered by hydraulics, and throttling valves are used to control their work circuits. In recent years, two general trends are towards more energy efficient systems and electrification. With electrification, both efficiency and control performance can be improved by the elimination of throttling losses and the use of high-bandwidth inverter control. Electrification is generally accomplished with Electro-hydraulic actuators (EHA) but they are limited to lower powered systems due to the high cost of electric machines capable of high power or high torque. This project proposes a new system architecture for off-road vehicles - Hybrid Hydraulic Electric Architecture (HHEA) to improve efficiency and control performance without requiring large electric machines. The widely applicable architecture combines hydraulic power and electric power in such a way that the majority of power is provided hydraulically while electric drives are used to modulate this power. In particular, HHEA utilizes multiple common pressure rails to transmit the majority of power and small electric machines to modulate the power. The energy-saving potential of the the HHEA has been validated for the work circuits of a variety of mobile machines, from small 5-ton excavators to medium sized 20-ton excavators and wheel loaders, and representative duty cycles to reduce energy input by 50-80% compared to the commercial state-of-art load-sensing systems. In addition, the corner power requirements of the electrical machines can be downsized by 85% compared to the EHA approach. Various tradeoff studies have also been conducted, including sensitivities to individual components performances, controllers, accumulator sizes, and variations of the system architecture etc. A control strategy has been developed to maintain or exceed the motion control precision compared to current systems. The motion control strategy consists of a nominal controller, based on a passivity-based backstepping design, and a transition controller, based on least-norn feedforward design. The nominal controller is used in between common pressure rail switches whereas the transition controller compensates for any disturbance that common pressure rail switchings inflict on the system. The control strategy has been experimentally validated on both a medium pressure (200bar) hardware-in-the-loop (HIL) testbed and a high pressure (300+bar) HIL testbed. An efficient and power-dense integrated electric-hydraulic machine consisting of an axial flux electric machine and a radial hydrostatic piston hydraulic machine has been designed, constructed and tested. The machine has an active material power density of 6.1kW/kg, a rated speed of 12500 RPM, and a design efficiency of 85%. This is among the highest power density electric machines using conventional materials. While the integrated machine was designed for modulating the hydraulic power within the HHEA, it can also be used in other applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Real-Time PV Spinning Reserve Estimator

Curtailed photovoltaic (PV) generation is a zero-marginal-cost spinning reserve that can be used for a number of active power control services. Unlike traditional spinning reserve providers, however, i.e., fossil-fueled generators, which have well-defined operating characteristics, e.g., available headroom or potential high limit (PHL), PV plants have by nature variable and uncertain operating characteristics. To ensure the effective coordination between PV plants and the system operator during an active power control event, accurate knowledge of the PV PHL is essential. It ensures that enough headroom is reserved by the PV plants to deliver the award services in real time and informs feasible dispatch decisions made by the market operator. To tackle this challenge, a novel reference-control grouping-based PV plant reserve estimation method has been proposed by the National Renewable Energy Laboratory under past projects funded by the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Solar Energy Technologies Office. The estimation method separates inverters within a plant into two groups: a control group and a reference group. While the reference group is reserved to operate at its PHL, the control group can be curtailed to provide the grid services. Real-time outputs from the reference inverters are used to estimate the PHL for the whole plant based on the ratio between capacities of the reference group and of the plant. This work further enhances the methodology by (1) improving the model accuracy through machine learning; (2) automating the reference inverter selection through correlation analysis; (3) considering estimation look-ahead windows; and (4) applying to regional spinning reserve estimation. Significant performance improvement has been observed based on real-world data collected by CAISO, Southern Company, and Terabase Energy. Compared with the original scaling method, the newly proposed machine learning-based approach reduces the estimation errors by 30% and 13% at the plant level and region level, respectively. Results obtained from this project are intended to be used by grid operators, market operators, balancing authorities, and PV plant owners and operators to facilitate PV participation in ancillary service markets. Regulators, policymakers, and system planners can also consider the results of this work in their decision-making processes. In addition to the performance improvement on the existing reference-control based grouping method, we also investigated how the variability of PV generation from a single PV inverter can be used to represent the variability of PV generation at the plant level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Luminescence relaxation dynamics for planar and rolled-up CdSe nanocrystals in a photonic-crystal matrix

Samples of inverted photonic-crystal films, containing planar and rolled-up (in the form of scrolls) CdSe nanocrystals, are studied. The transmission spectra of these structures are recorded. These spectra (along with the change in colour) confirm the incorporation of nanocrystals into the films. The photoluminescence decay dynamics is investigated. It is shown that the photonic-crystal matrix affects significantly the luminescence kinetics of nanostructures. The differences in the decay curves measured for nanocrystals in a photonic-crystal matrix and for their ensemble on a glass substrate are explained by the influence of the photonic-crystal stop band and the orientational effect of crystalline matrix, which orients anisotropic nanocrystals and prevents them from aggregation. The results obtained may be important for potential applications in optoelectronic devices. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of glide symmetry protected helical edge states in a WTe 2 monolayer

Helical edge states in quantum spin Hall (QSH) materials are central building blocks of topological matter design and engineering. Despite their principal topological protection against elastic backscattering, the level of operational stability depends on manifold parameters such as the band gap of the given semiconductor system in the “inverted” regime, temperature, disorder, and crystal orientation. Here, we theoretically investigate electronic and transport properties of QSH edge states in large gap 1-T' WTe 2 monolayers. We explore the impact of edge termination, disorder, temperature, and interactions on experimentally addressable edge state observables, such as local density of states and conductance. We show that conductance quantization can remain surprisingly robust even for heavily disordered samples because of an anomalously small edge state decay length and additional protection related to the large direct gap allowed by glide symmetry. From the simulation of temperature-dependent resistance, we find that moderate disorder enhances the stability of conductance by localizing bulk states. We evaluate the edge state velocity and Luttinger liquid parameter as functions of the chemical potential, finding prospects for physics beyond linear helical Luttinger liquids in samples with ultraclean and well-defined edges.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Assessing the impact of Byzantine attacks on coupled phase oscillators

Abstract For many coupled dynamical systems, the interaction is the outcome of the measurement that each unit has of the others as e.g. in modern inverter-based power grids, autonomous vehicular platoons or swarms of drones, or it is the result of physical flows. Synchronization among all the components of these systems is of primal importance to avoid failures. The overall operational state of these systems therefore crucially depends on the correct and reliable functioning of the individual elements as well as the information they transmit through the network. Here, we investigate the effect of Byzantine attacks where one unit does not behave as expected, but is controlled by an external attacker. For such attacks, we assess the impact on the global collective behavior of nonlinearly coupled phase oscillators. We relate the synchronization error induced by the input signal to the properties of the attacked node. This allows to anticipate the potential of an attacker and identify which network components to secure.

Tyloo, Melvyn (ORCID:0000000317614095)↗

Optical readout of singlet fission biexcitons in a heteroacene with photoluminescence detected magnetic resonance

Molecular spin systems based on photoexcited triplet pairs formed via singlet fission (SF) are attractive as carriers of quantum information because of their potentially pure and controllable spin polarization, but developing systems that offer optical routes to readout as well as initialization is challenging. Herein, we characterize the electron spin magnetic resonance change in the photoluminescence intensity for a tailored organic molecular crystal while sweeping a microwave drive up to 10 GHz in a broadband loop structure. We observe resonant transitions for both triplet and quintet spin sublevel populations showing their optical sensitivity and revealing the zero-field parameters for each. We map the evolution of these spectra in both microwave frequency and magnetic field, producing a pattern of optically detected magnetic resonance (ODMR) peaks. Fits to these data using a suitable model suggest significant spin polarization in this system with orientation selectivity. Unusual excitation intensity dependence is also observed, which inverts the sign of the ODMR signal for the triplet features, but not for the quintet. These observations demonstrate optical detection of the spin sublevel population dictated by SF and intermolecular geometry, and highlight anisotropic and multi-scale dynamics of triplet pairs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enabling Technology for Energy Sustainability: Power Electronic Converter Control for Renewables

To ensure high penetration of renewable energy sources into power grids, their interfacing inverters need to be designed to provide grid support functions. Important grid support functions include frequency and voltage support. To this end, the research community has recently invested heavily on grid-forming control pilot projects. Grid forming control aims to replace traditional grid following control, which is based on phase-locked loop and can achieve decoupled real and reactive power control. Here, in this article, we review the state-of-the-art grid following and forming technology and point out some deficiencies in dynamic performance in the widely adopted grid-forming control design. We also examine how to ensure that the vector control capable of decoupled real and reactive power regulation can also be achieved in the grid forming design. This type of design has been prototyped and shown great potential to enable retrofitting of large amounts of grid-following controllers through purely software algorithm update. The technology ensures reliable operation of power grids with high penetration of IBRs, thereby further reducing fossil fueled energy sources and cut down carbon emission.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

Single-Objective Airy Light-Sheet Imaging

Despite its massive potential, standard light-sheet imaging (LSI) faces key challenges, such as the incompatibility with common sample mounting techniques and low-resolution imaging. Single-objective LSI attempts to address these issues but often suffers from limited fields-of-view and throughput rates, or requires multiple optics that increase costs, alignment complexity, and losses. To overcome these challenges of standard single-objective LSI, we introduce single-objective Airy light-sheet imaging (SoALSI). SoALSI leverages the extraordinary self-acceleration properties of the Airy beam, achieving 5× higher imaging rates and enhanced imaging efficiency than standard single-objective LSI. Here, we demonstrate SoALSI’s versatility through rigorous contrast and resolution characterizations and by high-resolution imaging of diverse biological specimens, including malaria parasite-infected red blood cells and plant root tissue. SoALSI seamlessly integrates with any standard inverted microscope frame, enabling broader accessibility for the bioimaging community to explore biological processes in a wide range of specimens with enhanced resolution and imaging contrast.

airy beam↗

Feasibility Analyses for the Microgrid of the Mountain in the Cordillera Central Region of Puerto Rico

Distributed energy resource (DER) development can benefit communities through improvement of access to reliable electricity and a resilient energy system. Many place-specific considerations must be accounted for when designing electrical systems with co-located generation and loads. This paper presents an overview of four studies focusing on different aspects for regional DER development in the Cordillera Central region of Puerto Rico, including a grid and load stability study with the introduction of solar energy generation, microgrid design based on the solar resource in the area, resilience considerations during power outage scenarios, and qualitative risk aspects for components in the microgrid. Additionally, a conceptual substation microgrid analysis is conducted using the Microgrid Design Toolkit (MDT) to evaluate trade-offs between cost and energy availability, providing insights into optimal design strategies. A microgrid resilience assessment is performed using the Resilient Nodal Cluster Analysis Tool (ReNCAT) to identify critical loads and evaluates their accessibility during outages, emphasizing the importance of community needs. Finally, a qualitative risk assessment utilizing Hazard and Operability Analysis (HAZOP) methods highlights potential hazards and mitigations for microgrid components, ensuring robust system design and operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar PV Curtailment in Changing Grid and Technological Contexts: Preprint

Solar photovoltaic (PV) systems generate electricity with no marginal costs or emissions. As a result, PV output is almost always prioritized over other fuel sources and delivered to the electric grid. At increasing levels of PV penetration situations arise where PV is curtailed, either because of local supply/demand imbalances or to maintain system flexibility. In 2018, we estimate that about 6.5 million MWh of PV output was curtailed in four key countries: Chile, China, Germany, and the United States. We find that PV curtailment peaks in the spring and fall, when PV output is relatively high but electricity demand is relatively low. Similar to the case of wind, some PV curtailment is attributable to limited transmission capacity connecting sparsely populated solar-heavy regions to load centers.Grid policies generally seek to minimize curtailment because it is viewed as an economic and environmental loss. However, we argue that changing grid and technological contexts warrant new thinking on PV curtailment. In the grid context, as grids integrate more PV and other renewable energy generation, seeking an optimal level of accepted curtailment becomes more efficient than preventing it. In the technological context, emerging technologies such as advanced inverters and low-cost battery storage are making PV systems more flexible. With flexible PV, grid operators can use withheld PV output to provide various non-generation grid services. This withheld PV output is a form of curtailment under prevailing definitions of the term. Hence, policies that aim to minimize curtailment may undercut the ability of grid operators to fully use the emerging capabilities of flexible PV systems. We argue that the changing grid and technological contexts require a re-examination of the curtailment paradigm. We argue that PV output that is withheld to provide grid services is fundamentally different from output that goes unused in response to system constraints. As a result, we propose a more exclusive definition of curtailment as unused PV output rather than the more expansive conventional definition as any reduction in system output from its technical potential. The terminological distinction is more than a question of semantics. Facilitating grid services by withholding PV output may increase the potential value of flexible PV systems to the grid. This shift in thinking may allow grid operators and policymakers to think in terms of PV curtailment management rather than minimization. Effective curtailment management may include policies that increase PV system dispatchability, alternative PV compensation schemes that decouple generator revenue from system output, and policies to increase grid flexibility.

Chile↗

Strictly Enforcing Invertibility and Conservation in CNN-Based Super Resolution for Scientific Datasets

Abstract Recently, deep convolutional neural networks (CNNs) have revolutionized image “super resolution” (SR), dramatically outperforming past methods for enhancing image resolution. They could be a boon for the many scientific fields that involve imaging or any regularly gridded datasets: satellite remote sensing, radar meteorology, medical imaging, numerical modeling, and so on. Unfortunately, while SR-CNNs produce visually compelling results, they do not necessarily conserve physical quantities between their low-resolution inputs and high-resolution outputs when applied to scientific datasets. Here, a method for “downsampling enforcement” in SR-CNNs is proposed. A differentiable operator is derived that, when applied as the final transfer function of a CNN, ensures the high-resolution outputs exactly reproduce the low-resolution inputs under 2D-average downsampling while improving performance of the SR schemes. The method is demonstrated across seven modern CNN-based SR schemes on several benchmark image datasets, and applications to weather radar, satellite imager, and climate model data are shown. The approach improves training time and performance while ensuring physical consistency between the super-resolved and low-resolution data. Significance Statement Recent advancements in using deep learning to increase the resolution of images have substantial potential across the many scientific fields that use images and image-like data. Most image super-resolution research has focused on the visual quality of outputs, however, and is not necessarily well suited for use with scientific data where known physics constraints may need to be enforced. Here, we introduce a method to modify existing deep neural network architectures so that they strictly conserve physical quantities in the input field when “super resolving” scientific data and find that the method can improve performance across a wide range of datasets and neural networks. Integration of known physics and adherence to established physical constraints into deep neural networks will be a critical step before their potential can be fully realized in the physical sciences.

54 ENVIRONMENTAL SCIENCES↗

Surface reaction for efficient and stable inverted perovskite solar cells

We report perovskite solar cells (PSCs) with an inverted structure (often referred to as the p-i-n architecture) are attractive for future commercialization due to their easily scalable fabrication, reliable operation, and compatibility with a wide range of perovskite-based tandem device architectures. However, the power conversion efficiency (PCE) of p-i-n PSCs falls behind n-i-p (or normal) structure counterparts. This large performance gap could undermine efforts to adopt p-i-n architectures, despite their other advantages. Given the remarkable advances in perovskite bulk materials optimization over the past decade, interface engineering has become the most important strategy to push PSC performance to its limit. Here, we report a reactive surface engineering approach based on a simple post-growth treatment of 3-(Aminomethyl)pyridine (3-APy) on top of a perovskite thin film. First, the 3-APy molecule selectively reacts with surface FA+, reducing perovskite surface roughness and surface potential fluctuations associated with surface steps/terraces. Second, the reaction product on the perovskite surface decreases the formation energy of charged iodine-vacancies, leading to effective n-type doping with a reduced work function in the surface region. With this reactive surface engineering, the resulting p-i-n PSCs obtained a PCE over 25%, along with retaining 87% of the initial PCE after over 2400 h of one-sun operation at about 55 degrees C in air.

14 SOLAR ENERGY↗

Applying Bayesian inference and deterministic anisotropy to retrieve the molecular structure ∣Ψ(R)∣2 distribution from gas-phase diffraction experiments

Abstract Currently, our general approach to retrieving molecular structures from ultrafast gas-phase diffraction heavily relies on complex ab initio electronic or vibrational excited state simulations to make conclusive interpretations. Without such simulations, inverting this measurement for the structural probability distribution is typically intractable. This creates a so-called inverse problem. Here we address this inverse problem by developing a broadly applicable method that approximates the molecular frame structure ∣Ψ( R , t )∣ 2 distribution independent of these complex simulations. We retrieve the vibronic ground state ∣Ψ( R )∣ 2 for both simulated stretched NO 2 and measured N 2 O. From measured N 2 O, we observe 40 mÅ coordinate-space resolution from 3.75 Å −1 reciprocal space range and poor signal-to-noise, a 50X improvement over traditional Fourier transform methods. In simulated NO 2 diffraction experiments, typical to high signal-to-noise levels predict 100–1000X resolution improvements, down to 0.1 mÅ. By directly measuring the width of ∣Ψ( R )∣ 2 , we open ultrafast gas-phase diffraction capabilities to measurements beyond current analysis approaches. This method has the potential to effectively turn gas-phase ultrafast diffraction into a discovery-oriented technique to probe systems that are prohibitively difficult to simulate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Making Invisible Visible: Data-Driven Seismic Inversion With Spatio-Temporally Constrained Data Augmentation

Deep learning and data-driven approaches have shown great potential in scientific domains. The promise of data-driven techniques relies on the availability of a large volume of high-quality training datasets. Due to the high cost of obtaining data through expensive physical experiments, instruments, and simulations, data augmentation techniques for scientific applications have emerged as a new direction for obtaining scientific data recently. However, existing data augmentation techniques originating from computer vision yield physically unacceptable data samples that are not helpful for the domain problems that we are interested in. In this article, we develop new data augmentation techniques based on convolutional neural networks. Specifically, our generative models leverage different physics knowledge (such as governing equations, observable perception, and physics phenomena) to improve the quality of the synthetic data. To validate the effectiveness of our data augmentation techniques, we apply them to solve a subsurface seismic full-waveform inversion using simulated CO 2 leakage data. Our interest is to invert for subsurface velocity models associated with very small CO 2 leakage. We validate the performance of our methods using comprehensive numerical tests. Here via comparison and analysis, we show that data-driven seismic imaging can be significantly enhanced by using our data augmentation techniques. Particularly, the imaging quality has been improved by 15% in test scenarios of general-sized leakage and 17% in small-sized leakage when using an augmented training set obtained with our techniques.

58 GEOSCIENCES↗