Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Infrared techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The 55Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

A technique involving Fe-55 X-rays provides a straightforward method to measure the response of a detector. The detector's response can lead directly to a calculation of the conversion gain (e(-) ADU(-1) ), as well as aid detector design and performance studies. We calibrate the Fe-15 X-ray energy response and pair production energy of HgCdTe using 8 HST WFC3 1.7 micron flight grade detectors. The results show that each Ka X-ray generates 2273 +/- 137 electrons, which corresponds to a pair-production energy of 2.61 +/- 0.16 eV. The uncertainties are dominated by our knowledge of the conversion gain. In future studies, we plan to eliminate this uncertainty by directly measuring conversion gain at very low light levels.

Fox, Ori↗

Automatic detection of microlensing events in the galactic bulge using machine learning techniques

The Wide Field Infrared Survey Telescope (WFIRST) is a NASA flagship mission scheduled to launch in mid-2020, with more than one year of its lifetime dedicated to microlensing survey. The survey is to discover thousands of exoplanets near or beyond the snowline via their microlensing light curve signatures, enabling a Kepler-like statistical analysis of planets at ~1-10 AU from their host stars and potentially revolutionizing our understanding of planet formation. The goal of our work is to create an automated system that has the ability to efficiently process and classify large-scale astronomical datasets that missions such as WFIRST will produce. In this paper, we discuss our framework that utilizes features election and parameter optimization for classification models to automatically differentiate the different types of stellar variability and detect microlensing events.

Shvartzvald, Yossi↗

In-flight off-surface flow visualization using infrared imaging

A light test investigation was conducted to evaluate an infrared (IR) imaging technique to visualize off-surface flow phenomena. A single-engine, general-aviation airplane was equipped with an IR imaging system that viewed the region around the left wingtip. Vortical flow at the wingtip was seeded with surfur hexafluoride, a gas with strong infrared absorbing and emitting characteristics. Different terrain and sky backgrounds were evaluated for their effect on IR images of vortical flow. The best IR images were obtained with a clear background. The results of the investigation indicate that IR flow visualization compliments existing smoke generator methods for off-surface flow visualization.

Manuel, Gregory S.↗

Finite Volume Numerical Methods for Aeroheating Rate Calculations from Infrared Thermographic Data

The use of multi-dimensional finite volume numerical techniques with finite thickness models for calculating aeroheating rates from measured global surface temperatures on hypersonic wind tunnel models was investigated. Both direct and inverse finite volume techniques were investigated and compared with the one-dimensional semi -infinite technique. Global transient surface temperatures were measured using an infrared thermographic technique on a 0.333-scale model of the Hyper-X forebody in the Langley Research Center 20-Inch Mach 6 Air tunnel. In these tests the effectiveness of vortices generated via gas injection for initiating hypersonic transition on the Hyper-X forebody were investigated. An array of streamwise orientated heating striations were generated and visualized downstream of the gas injection sites. In regions without significant spatial temperature gradients, one-dimensional techniques provided accurate aeroheating rates. In regions with sharp temperature gradients due to the striation patterns two-dimensional heat transfer techniques were necessary to obtain accurate heating rates. The use of the one-dimensional technique resulted in differences of 20% in the calculated heating rates because it did not account for lateral heat conduction in the model.

Daryabeigi, Kamran↗

Near-infrared spectroscopy for monitoring of tissue oxygenation of exercising skeletal muscle in a chronic compartment syndrome model

Variations in the levels of muscle hemoglobin and of myoglobin oxygen saturation can be detected non-invasively with near-infrared spectroscopy. This technique could be applied to the diagnosis of chronic compartment syndrome, in which invasive testing has shown increased intramuscular pressure associated with ischemia and pain during exercise. We simulated chronic compartment syndrome in ten healthy subjects (seven men and three women) by applying external compression, through a wide inflatable cuff, to increase the intramuscular pressure in the anterior compartment of the leg. The tissue oxygenation of the tibialis anterior muscle was measured with near-infrared spectroscopy during gradual inflation of the cuff to a pressure of forty millimeters of mercury (5.33 kilopascals) during fourteen minutes of cyclic isokinetic dorsiflexion and plantar flexion of the ankle. The subjects exercised with and without external compression. The data on tissue oxygenation for each subject then were normalized to a scale of 100 per cent (the baseline value, or the value at rest) to 0 per cent (the physiological minimum, or the level of oxygenation achieved by exercise to exhaustion during arterial occlusion of the lower extremity). With external compression, tissue oxygenation declined at a rate of 1.4 +/- 0.3 per cent per minute (mean and standard error) during exercise. After an initial decrease at the onset, tissue oxygenation did not decline during exercise without compression. The recovery of tissue oxygenation after exercise was twice as slow with compression (2.5 +/- 0.6 minutes) than it was without the use of compression (1.3 +/- 0.2 minutes).

NASA Discipline Musculoskeletal↗

Finite Volume Numerical Methods for Aeroheating Rate Calculations from Infrared Thermographic Data

The use of multi-dimensional finite volume heat conduction techniques for calculating aeroheating rates from measured global surface temperatures on hypersonic wind tunnel models was investigated. Both direct and inverse finite volume techniques were investigated and compared with the standard one-dimensional semi-infinite technique. Global transient surface temperatures were measured using an infrared thermographic technique on a 0.333-scale model of the Hyper-X forebody in the NASA Langley Research Center 20-Inch Mach 6 Air tunnel. In these tests the effectiveness of vortices generated via gas injection for initiating hypersonic transition on the Hyper-X forebody was investigated. An array of streamwise-orientated heating striations was generated and visualized downstream of the gas injection sites. In regions without significant spatial temperature gradients, one-dimensional techniques provided accurate aeroheating rates. In regions with sharp temperature gradients caused by striation patterns multi-dimensional heat transfer techniques were necessary to obtain more accurate heating rates. The use of the one-dimensional technique resulted in differences of 20% in the calculated heating rates compared to 2-D analysis because it did not account for lateral heat conduction in the model.

Daryabeigi, Kamran↗

Applications of Advanced Nondestructive Evaluation (NDE) and Structural Health Monitoring (SHM) Techniques to Address Safety of Flight Issues on NASA Spacecraft

Advanced NDE and SHM techniques are critical for ensuring the reliability and safety of NASA launch vehicles and spacecraft. NDE techniques such as infrared thermography, THz imaging, x-ray computed tomography and backscatter x-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide SHM to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these NDE and SHM techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

Advanced Nondestructive Evaluation (NDE)↗

Applications of Advanced Nondestructive Measurement Techniques to Address Safety of Flight Issues on NASA Spacecraft

Advanced nondestructive measurement techniques are critical for ensuring the reliability and safety of NASA spacecraft. Techniques such as infrared thermography, THz imaging, X-ray computed tomography and backscatter X-ray are used to detect indications of damage in spacecraft components and structures. Additionally, sensor and measurement systems are integrated into spacecraft to provide structural health monitoring to detect damaging events that occur during flight such as debris impacts during launch and assent or from micrometeoroid and orbital debris, or excessive loading due to anomalous flight conditions. A number of examples will be provided of how these nondestructive measurement techniques have been applied to resolve safety critical inspection concerns for the Space Shuttle, International Space Station (ISS), and a variety of launch vehicles and unmanned spacecraft.

Prosser, Bill↗

Non-invasive neuroimaging using near-infrared light

This article reviews diffuse optical brain imaging, a technique that employs near-infrared light to non-invasively probe the brain for changes in parameters relating to brain function. We describe the general methodology, including types of measurements and instrumentation (including the tradeoffs inherent in the various instrument components), and the basic theory required to interpret the recorded data. A brief review of diffuse optical applications is included, with an emphasis on research that has been done with psychiatric populations. Finally, we discuss some practical issues and limitations that are relevant when conducting diffuse optical experiments. We find that, while diffuse optics can provide substantial advantages to the psychiatric researcher relative to the alternative brain imaging methods, the method remains substantially underutilized in this field.

Non-NASA Center↗

Radiative transfer in spherical circumstellar dust envelopes. III - Dust envelope models of some well known infrared stars

The radiative transfer techniques described elsewhere by the author have been employed to construct dust envelope models of several well known infrared stars. The resulting calculations indicate that the infrared emissivity of circumstellar grains generally must be higher than that which many calculations of small nonsilicate grains yield. This conclusion is dependent to some degree on the (unknown) size of the stellar envelopes considered, but is quite firm in the case of the spatially resolved envelope of IRC + 10216. Further observations of the spatial distribution of the infrared radiation from stellar envelopes will be invaluable in deciphering the properties of the circumstellar grains.

Apruzese, J. P.↗

Bench-Top Antigen Detection Technique that Utilizes Nanofiltration and Fluorescent Dyes which Emit and Absorb Light in the Near Infrared

This article discusses the development of a bench-top technique to detect antigens in fluids. The technique involves the use of near infrared NIR fluorescent dyes conjugated to antibodies, centrifugation, nanofilters, and spectrometry. The system used to detect the antigens utilizes a spectrometer, fiber optic cables, NIR laser, and laptop computer thus making it portable and ideally suited for desk top analysis. Using IgM as an antigen and the secondary antibody, anti-IgM conjugated to the near infrared dye, IRDye (trademark) 800, for detection, we show that nanofiltration can efficiently and specifically separate antibody-antigen complexes in solution and that the complexes can be detected by a spectrometer and software using NIR laser excitation at 778 nm and NIR dye offset emission at 804 nm. The peak power detected at 778 nm for the excitation emission and at 804 nm for the offset emission is 879 pW (-60.06 dBm) and 35.7 pW (-74.5 dBm), respectively.

Varaljay-Spence, Vanessa A.↗

Infrared emission from X-ray and optically emitting regions in the Cygnus Loop supernova remnant

We present a new technique for analyzing the infrared (IR) emission of a supernova remnant (SNR) and apply it to the Cygnus Loop. The technique consists of a decomposition of the IR emission from the remnant (in all four IRAS bands) into two distinct emission components. The first component is spatially correlated with the X-ray emission from the remnant and arises from collisionally heated dust in the shocked gas. The second component is spatially correlated with the optical filaments and arises from dust which is radiatively or collisionally heated within the filaments, and from IR lines emitted by the shocked gas. The decomposition allows us to determine the characteristics of the dust, examine evidence for grain processing through the shock, constrain various remnant parameters, and demonstrate how the morphology of the environment determines the IR emission from the remnant.

Arendt, Richard G.↗

Effect of a magnetic field on the diffusion of an electron-hole plasma in germanium.

Study in germanium of an optically injected electron-hole plasma, parallel and perpendicular to an applied magnetic field. The density gradient within the crystal was measured directly by an infrared-beam-absorption technique. Diffusion measurements made parallel to the magnetic field are adequately explained by the theory.

Gurnee, M. N.↗

Infrared response measurements on radiation-damaged Si/Li/ detectors.

The improved infrared response (IRR) technique has been used to qualitatively compare radiation effects on Si(Li) detectors with energy levels reported for silicon in the literature. Measurements have been made on five commercial silicon detectors and one fabricated in-house, both before and after irradiation with fast neutrons, 1.9-MeV protons, and 1.6-MeV electrons. Effects dependent upon the extent of radiation damage have been observed. It seems likely that the photo-EMF, or photo-voltage, effect is the basic mechanism for the observation of IRR in p-i-n diodes with a wide i-region. Experimental characteristics of the IRR measurement are in agreement with those of the photovoltage effect.

Sher, A. H.↗

3 nu sub 3 band of C-12H4 at 1.1 micron.

The 3 nu sub 3 absorption band of C-12H4 has been measured using a high-resolution vacuum infrared spectrometer. A technique is described which allows an extension of the use of the absorption standards available at 4.7 microns to the photomultiplier region of the spectrum. The new measurements indicate a shift of about 0.18 per cm from the most recently published measurements of this band.

Pugh, L. A.↗