Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Incident response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multiscale and multiphysics FEA simulation and materials optimization for laser ultrasound transducers

In this study, the relationship between the nanocomposite design and the laser ultrasound transducer (LUT) characteristics was investigated through simulations in multiple scale levels for material behavior, device response, and acoustic wave propagation in media. First, the effects of the nanoparticle size and concentration on the effective properties of composites were quantitatively investigated with the finite element analysis (FEA) method. Second, the effective properties of the nanocomposite were assigned to the layer, which is modeled as a homogeneous material, in the FEA for the LUT simulating the energy conversion from the incident laser to the acoustic wave. Finally, the ultrasound propagation in the water was calculated by a theoretical wave propagation model. The FEA-based prediction was compared with the experimental data in the literature and a theoretical analysis for LUT based on Thermal-Acoustic coupling. As a result, the ultrasound waves on the transducer surface and at a distance in the water could be predicted. Based on the hierarchically integrated prediction procedure, the optimal conditions of the photoacoustic nanocomposites were investigated through the parametric study with the particle size and concentration as variables. The results guide the material designs optimized for different device characteristics, such as high pressure and broad bandwidth.

36 MATERIALS SCIENCE↗

The WISE-2MASS Survey: Red Quasars Into the Radio Quiet Regime

We present a highly complete sample of broad-line (Type 1) QSOs out to z ~ 3 selected by their mid-infrared colors, a method that is minimally affected by dust reddening. We remove host-galaxy emission from the spectra and fit for excess reddening in the residual QSOs, resulting in a Gaussian distribution of colors for unreddened (blue) QSOs, with a tail extending toward heavily reddened (red) QSOs, defined as having E(B – V) > 0.25. This radio-independent selection method enables us to compare red and blue QSO radio properties in both the FIRST (1.4 GHz) and VLASS (2–4 GHz) surveys. Consistent with recent results from optically selected QSOs from SDSS, we find that red QSOs have a significantly higher detection fraction and a higher fraction of compact radio morphologies at both frequencies. We employ radio stacking to investigate the median radio properties of the QSOs including those that are undetected in FIRST and VLASS, finding that red QSOs have significantly brighter radio emission and steeper radio spectral slopes compared with blue QSOs. Finally, we find that the incidence of red QSOs is strongly luminosity dependent, where red QSOs make up >40% of all QSOs at the highest luminosities. Overall, red QSOs comprise ~40% of higher luminosity QSOs, dropping to only a few percent at lower luminosities. Furthermore, red QSOs make up a larger percentage of the radio-detected QSO population. We argue that dusty AGN-driven winds are responsible for both the obscuration as well as excess radio emission seen in red QSOs.

79 ASTRONOMY AND ASTROPHYSICS↗

Longitudinal Surveillance for Chronic Health Conditions in Former United States Department of Energy Site Workers

The aim of the study was to determine (1) the rate at which rescreening former Department of Energy site workers identifies noncommunicable chronic diseases and (2) the development of comorbid conditions. Incidence and prevalence of hypertension, diabetes, reduced kidney function, and peripheral neuropathy at both initial and return screenings were calculated. Risk ratio of chronic disease development at return screening based on the presence of other conditions at initial screening were estimated with generalized linear regression. Prevalence of reduced kidney function was 19% at initial examination and 30% at return examination. The screening program was responsible for identifying 81% of reduced kidney function cases. Similar findings were present for the other chronic conditions examined. As a result, former worker health surveillance programs help identify significant health conditions among DOE workers, subcontractors, and visitors. Longitudinal screening of participants detects additional chronic conditions.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of CFD simulations of the moored DeepCwind offshore wind semisubmersible in irregular waves

This article examines the use of computational fluid dynamics (CFD) simulations to predict the response of a floating wind platform to irregular-wave excitation. This work was conducted as part of the Reproducible CFD Joint Industry Project for Floating Offshore Wind Applications and involved verification across several participants and modeling tools and validation against experiments. The authors pay special attention to the uncertainties in both CFD results and experimental measurements. In this work, we perform detailed comparisons of the incident waves and the motion of a moored structure. The nonlinear, low-frequency resonance motion is of particular interest because it potentially drives the mooring and tower-base loads. The verification and validation study is partially successful in that the CFD simulations capture the low-frequency slow-drift motion well but underpredict the low-frequency pitch resonance. This underprediction can be attributed in part to the CFD incident waves, which showed some discrepancies with the experimental waves, especially around extreme events. The effects of the wave discrepancies are also estimated and investigated using a mid-fidelity OpenFAST model. Overall, the present study increases our confidence in using CFD simulations to predict the global performance of offshore wind platforms in irregular waves and to produce data for the calibration of lower-fidelity models.

17 WIND ENERGY↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Conceptual Design of a Scintillator-Based Fast-Ion Loss Detector for the Wendelstein 7-X Stellarator

Here, a conceptual design of a scintillator-based fast-ion loss detector (FILD) has been developed for the Wendelstein 7-X stellarator (W7-X). Simulations using the Monte Carlo codes ASCOT5 and BEAMS3D have been performed to calculate the expected flux of neutral beam injection (NBI)-generated fast hydrogen ions onto the conceptual detector probe head. These fast-ion loss fluxes have been calculated for several magnetic field configurations as well as probe insertion positions. At the maximum insertion position, both co-and counter-going losses with high incident pitch angles are observed; however, at retracted positions, only co-going fast ions reach the probe head. The FILDSIM code has been used to optimize the geometry of the detector entrance and collimating elements to achieve a wide velocity space coverage as well as a high velocity–space resolution. A synthetic FILD signal is calculated for the expected loss distribution via forward modeling using the instrument response function. The synthetic signal is found to largely retain the velocity space features of the loss distribution.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Specular-reflection contributions to static and dynamic radiation forces on circular cylinders

Interest in the response of highly reflecting objects in water to modulated acoustical radiation forces makes it appropriate to consider contributions to such forces from perfectly reflecting objects to provide insight into radiation forces. The acoustic illumination can have wavelengths much smaller than the object's size, and objects of interest may have complicated shapes. Here, the specular contribution to the oscillating radiation force on an infinite circular cylinder at normal incidence is considered for double-sideband-suppressed carrier-modulated acoustic illumination. The oscillatory magnitude of the specular force decreases monotonically with increasing modulation frequency, and the phase of the oscillating force depends on the relative phase of the sidebands. The phase dependence on the modulation frequency can be reduced with the appropriate selection of a sideband relative-phase parameter. That is a consequence of the significance of rays that are incident on the cylinder having small impact parameters that are nearly backscattered. For one choice of a relative sideband phase, a prior partial wave series (PWS) solution is available, which supports the specular analysis when the PWS is evaluated for a rigid cylinder. The importance of specular contributions for aluminum cylinders in water is noted. A specular analysis for an analogous spherical reflector is also summarized.

Marston, Philip L. (ORCID:0000000306778537)↗

Higher education responses to COVID-19 in the United States: Evidence for the impacts of university policy

With a dataset of testing and case counts from over 1,400 institutions of higher education (IHEs) in the United States, we analyze the number of infections and deaths from SARS-CoV-2 in the counties surrounding these IHEs during the Fall 2020 semester (August to December, 2020). We find that counties with IHEs that remained primarily online experienced fewer cases and deaths during the Fall 2020 semester; whereas before and after the semester, these two groups had almost identical COVID-19 incidence. Additionally, we see fewer cases and deaths in counties with IHEs that reported conducting any on-campus testing compared to those that reported none. To perform these two comparisons, we used a matching procedure designed to create well-balanced groups of counties that are aligned as much as possible along age, race, income, population, and urban/rural categories—demographic variables that have been shown to be correlated with COVID-19 outcomes. We conclude with a case study of IHEs in Massachusetts—a state with especially high detail in our dataset—which further highlights the importance of IHE-affiliated testing for the broader community. The results in this work suggest that campus testing can itself be thought of as a mitigation policy and that allocating additional resources to IHEs to support efforts to regularly test students and staff would be beneficial to mitigating the spread of COVID-19 in a pre-vaccine environment.

60 APPLIED LIFE SCIENCES↗

Time-resolved measurement of electron beam neutralization

An intense relativistic electron beam (IREB) incident on a target generates positive ions by stimulated and thermal desorption of adsorbed gas, and subsequent electron impact ionization. These ions are accelerated upstream by the beam space-charge potential, thereby partially neutralizing the beam. If there is enough neutralization, the repulsive space-charge force can be overcome by the magnetic-pinch force due to the beam current. This so-called ion focusing is responsible for time dependent defocusing of the radiographic source spot. Since a single monolayer of adsorbed gas has a surface density of about 10 15 /cm 2 and is formed in about one second in a one micro-Torr vacuum, there is always enough adsorbed gas to make this a concern in our accelerators. Therefore, time-resolved measurements of the degree of neutralization are valuable for better understanding of this process with an eye to mitigation for improvement of our radiography. Moreover, these measurements would aid quantification of uncertainties due to these effects when using invasive beam diagnostics, such as OTR imaging targets.

43 PARTICLE ACCELERATORS↗

Sensitivity calibration of a Carestream HPX-1 image plate scanner

There is a need to measure the sensitivity of the image plate scanners used to scan Z shot data. The Carestream HPX-1 image plate scanner was tested, and its performance was characterized to determine the system sensitivity in terms of signal per incident photon as a function of x-ray energy. A Manson source was used to simultaneously expose an Amptek x-ray multi-channel analyzer and image plates, allowing for a comparison of the counts as a function of energy to the signal recorded on the image plates. NIST-certified radioactive sources were used to assign an absolute sensitivity. Results indicate that the HPX-1 scanner response matches the shape of the modeled response, allowing for absolute scaling using NIST-certified radioisotope sources. The HPX-1 scanner shows a stable response with measurements taken over one week. In contrast, the sensitivity of the DITABIS scanner was characterized using the same approach, but it exhibits changes in its response that varied by more than 50% over the span of 4 days.

42 ENGINEERING↗

Laser-induced graphene gas sensors for environmental monitoring

Artemesia tridentatais a foundational plant taxon in western North America and an important medicinal plant threatened by climate change. Low-cost fabrication of sensors is critical for developing large-area sensor networks for understanding and monitoring a range of environmental conditions. However, the availability of materials and manufacturing processes is still in the early stages, limiting the capacity to develop cost-effective sensors at a large scale. In this study, we demonstrate the fabrication of low-cost flexible sensors using laser-induced graphene (LIG); a graphitic material synthesized using a 450-nm wavelength bench top laser patterned onto polyimide substrates. We demonstrate the effect of the intensity and focus of the incident beam on the morphology and electrical properties of the synthesized material. Raman analyses of the synthesized LIG show a defect-rich graphene with a crystallite size in the tens of nanometers. This shows that the high level of disorder within the LIG structure, along with the porous nature of the material provide a good surface for gas adsorption. The initial characterization of the material has shown an analyte response represented by a change in resistance of up to 5% in the presence of volatile organic compounds (VOCs) that are emitted and detected byArtemisiaspecies. Bend testing up to 100 cycles provides evidence that these sensors will remain resilient when deployed across the landscapes to assess VOC signaling in plant communities. The versatile low-cost laser writing technique highlights the promise of low-cost and scalable fabrication of LIG sensors for gas sensor monitoring.

Chemistry↗

Resonant propagation of x rays from the linear to the nonlinear regime

We present a theoretical study of temporal, spectral, and spatial reshaping of intense, ultrafast x-ray pulses propagating through a resonant medium. Our calculations are based on the solution of a three-dimensional time-dependent Schrodinger-Maxwell equation, with the incident x-ray photon energy on resonance with the core-level is-3p transition in neon. We study the evolution of the combined incident and medium-generated field, including the effects of stimulated emission, absorption, ionization, and Auger decay, as a function of the input pulse energy and duration. We find that stimulated Raman scattering between core-excited states 1s -1 3p and 2p -1 3p occurs at high x-ray intensity, and that the emission around this frequency is strongly enhanced when also including the similar 1s -1 -2p -1 response of the ion. We also explore the dependence of x-ray self-induced transparency (SIT) and self-focusing on the pulse intensity and duration, and we find that the stimulated Raman scattering plays an important role in both effects. Finally, we discuss how these nonlinear effects may potentially be exploited as control parameters for pulse properties of x-ray free-electron laser sources.

74 ATOMIC AND MOLECULAR PHYSICS↗

Sorption‐Induced Fiber Optic Plasmonic Gas Sensing via Small Grazing Angle of Incidence

Abstract Sensing technologies based on plasmonic nanomaterials are of interest for various chemical, biological, environmental, and medical applications. In this work, an incorporation strategy of colloidal plasmonic nanoparticles (pNPs) in microporous polymer for realizing distinct sorption‐induced plasmonic sensing is reported. This approach is demonstrated by introducing tin‐doped indium oxide pNPs into a polymer of intrinsic microporosity (PIM‐1). The composite film (pNPs‐polymer) provides distinct and tunable optical features on the fiber optic (FO) platform that can be used as a signal transducer for gas sensing (e.g., CO 2 ) under atmospheric conditions. The resulting pNPs‐polymer composite demonstrates high sensitivity response on FO in the evanescent field configuration, provided by the dramatic response of modes above the total‐internal‐reflection angle. Furthermore, by varying the pNPs content in the polymer matrix, the optical behavior of the pNPs‐polymer composite film can be tuned to affect the operational wavelength by over several hundred nanometers and the sensitivity of the sensor in the near‐infrared range. It is also shown that the pNPs‐polymer composite film exhibits remarkable stability over a period of more than 10 months by mitigating the physical aging issue of the polymer.

Kim, Ki‐Joong↗

Broken symmetries associated with a Kagome chiral charge order

Chirality, or handedness, is ubiquitous in science, from cell biology to physics, and in condensed matter can underlie exotic phases such as chiral charge density waves and chiral superconductivity. However, detecting subtle broken symmetries that define such states is challenging, leading to debate and controversy. Here, using second-order optical response, we reveal the broken symmetries of a chiral charge density wave in the Kagome lattice KV 3 Sb 5 . Polarization-dependent mid-infrared photocurrent microscopy uncovers a longitudinal, helicity-dependent photocurrent associated with the charge order, indicating broken inversion and mirror symmetries. These findings, supported by theoretical analysis, directly establish the intrinsic chiral nature of the ordered state. Moreover, the absence of a circular photogalvanic effect perpendicular to the incident light imposes stringent constraints on the point-group symmetries. Our study not only visualizes the chiral nature of the Kagome charge order, but also highlights the nonlinear photogalvanic effect as a sensitive probe for detecting subtle symmetry breakings.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Knowledge, Attitudes, and Practices Toward Ticks and Tickborne Disease among Healthcare Professionals Working in Schools in New York and Maryland

Healthcare Professionals Working in Schools (HPWS) are responsible for providing health services to students and play a role in providing education to prevent illnesses, including tickborne diseases (TBD). Providing TBD education to children has been shown to increase prevention behaviors and knowledge of TBD symptoms, but little is known regarding the current state of TBD awareness among HPWS. In spring 2019 we conducted a cross-sectional knowledge, attitudes, and practices (KAP) survey of HPWS in two states with a high incidence of Lyme disease (LD) to inform design of TBD prevention programs. The survey queried general knowledge of TBDs, school practices regarding TBDs, and availability of TBD resources. Overall, higher confidence, experience, risk perception, prior training on TBD, and more years employed as a HPWS were independently associated with knowledge of LD transmission, symptoms, and correct tick removal practices. State and local health departments should consider prioritizing engagement with HPWS to provide educational opportunities about tickborne diseases.

Nursing↗

Imaging perturbed shock propagation in powders

A novel experimental methodology is presented to study the deviatoric response of powders in shock regimes. The powders are confined to a cylindrical wedge volume, and a projectile-driven shock wave with a sinusoidally varying front propagates through the powder. The perturbed shock wave exhibits a damping behavior due to irreversible processes of viscosity and strength (deviatoric) of the powder with propagation through increasing powder thicknesses. The inclined surface of the wedge is polished and coated to establish a diffuse surface suitable for reflecting incident laser light into a high-speed camera imaging at 5 MHz. Images of the contrast loss upon shock wave arrival at the observation surface are post-processed for qualitative and quantitative information. New data of shock damping behavior with parameters of perturbation wavelength and initial shock strength are presented for powders of copper, tantalum, and tungsten carbide as well as their mixtures. We present the first full-field images showing additional spatial disturbances on the perturbed shock front that appear dependent on particle material and morphology.

47 OTHER INSTRUMENTATION↗

Pulse duration dependent effects of ultrafast laser induced damage on a 1030 nm multi-layer dielectric mirror for high repetition rate, high average power laser systems

High repetition rate, high peak, and average power laser systems are crucial for next-generation particle accelerators, inertial confinement fusion, and secondary particle sources. These applications demand durable laser optics, particularly interference coatings on optics lasting millions of shots at high fluence. This study focuses on designing, testing, and simulating multi-layer dielectric (MLD) mirrors for pulse durations of 260 fs, 77 fs, and 25 fs at 1030 nm wavelength and 45-degree incidence angle with p -polarization. S-on-1 laser-induced damage thresholds (LIDT) for varying pulse numbers were determined, with single-shot LIDT values of 0.98 Jcm -2 , 1.63 Jcm -2 , and 2.3 Jcm -2 for 25 fs, 77 fs, and 260 fs respectively. A strong correlation between blister shape and local fluence was observed, implying that the layer expansion in a blister depends on local fluence. We have also examined mechanisms responsible for laser-induced stress generation and energy release rates in blister formation. Damage mechanisms are further explored by finite-difference time-domain (FDTD) simulations, incorporating Keldysh strong field ionization, whose predictions were in excellent agreement with the onset of damage determined experimentally. These findings offer insights for enhancing MLD coating technology, promising more efficient and resilient laser systems for diverse scientific and industrial applications.

Noor, Mohamed Yaseen (ORCID:000000021036644X)↗

Calibration of the IXPE Focal Plane X-Ray Polarimeters to Polarized Radiation

The Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer mission—in partnership with the Italian Space Agency—dedicated to X-ray polarimetry in the 2–8 keV energy band. The IXPE telescope comprises three grazing incidence mirror modules coupled to three detector units hosting each one a Gas Pixel Detector, a gas detector that allows measuring the polarization degree by using the photoelectric effect. A wide and accurate ground calibration was carried out on the IXPE Detector Units at INAF-IAPS, in Italy, where a dedicated facility was setup at this aim. In this paper, we present the results obtained from this calibration campaign to study the IXPE focal plane detector response to polarized radiation. In particular, we report on the modulation factor, which is the main parameter to estimate the sensitivity of a polarimeter.

79 ASTRONOMY AND ASTROPHYSICS↗