Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “InC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Solar hot water system installed at Anderson, South Carolina

A description is given of the solar energy hot water system installed in the Days Inns of America, Inc., at Anderson, South Carolina. The building is a low-rise, two-story 114-room motel. The solar system was designed to provide 40 percent of the total hot water demand. The collector is a flat plate, liquid with an area of 750 square feet. Operation of this system was begun in November 1977, and has performed flawlessly for one year.

Source record↗

Diode step stress program for JANTX1N2970b

Data for the purpose of evaluating the effect of power/temperature step stress was studied when applied to the zener diode JANTX1N2970B manufactured by Siemens and General Semiconductor, Inc. A total of 48 samples from each manufacturer was submitted to the process. In addition, two control sample units were maintained for verification of the electrical parametric testing. The tests for determining power/temperature stresses are described, and test results are discussed. Failure analyses for power stress, and temperature stress are presented.

Source record↗

Test and evaluation of Fern Engineering Company, Incorporated, solar heating and hot water system

Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.

Source record↗

Instrumentation for controlling and monitoring environmental control and life support systems

Advanced Instrumentation concepts for improving performance of manned spacecraft Environmental Control and Life Support Systems (EC/LSS) have been developed at Life Systems, Inc. The difference in specific EC/LSS instrumentation requirements and hardware during the transition from exploratory development to flight production stages are discussed. Details of prior control and monitor instrumentation designs are reviewed and an advanced design presented. The latter features a minicomputer-based approach having the flexibility to meet process hardware test programs and the capability to be refined to include the control dynamics and fault diagnostics needed in future flight systems where long duration, reliable operation requires in-flight hardware maintenance. The emphasis is on lower EC/LSS hardware life cycle costs by simplicity in instrumentation and using it to save crew time during flight operation.

Yang, P. Y.↗

Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

Source record↗

Solar heating and hot water system installed at Saint Louis, Missouri

The solar heating and hot water system installed at the William Tao & Associates, Inc., office building in St. Louis, Missouri is described, including maintenance and construction problems, final drawings, system requirements, and manufacturer's component data. The solar system was designed to provide 50 percent of the hot water requirements and 45 percent of the space heating needs for a 900 sq ft office space and drafting room. The solar facility has 252 sq ft of glass tube concentrator collectors and a 1000 gallon steel storage tank buried below a concrete slab floor. Freeze protection is provided by a propylene glycol/water mixture in the collector loop. The collectors are roof mounted on a variable tilt array which is adjusted seasonally and is connected to the solar thermal storage tank by a tube-in-shell heat exchanger. Incoming city water is preheated through the solar energy thermal storage tank.

Source record↗

Solar energy system performance evaluation: Seasonal report for Decade 80 House, Tucson, Arizona

The operational and thermal performance of the Decade 80 solar energy system is described. The system was designed by Cooper Development Association, Inc. with space heating and space cooling to a one-story, single family residence located in Tucson, Arizona. The Decade 80 House was designed and built in the mid-70's to be a showplace/workshop for solar energy utilization. Superior construction techniques, the use of quality materials and a full time maintenance staff have served to make the entire system an outstanding example of the application of solar energy for residential purposes. The luxury of a full time, on-site maintenance person is perhaps the single most important aspect of this program. While most installations cannot support this level of maintenance, it was very useful in keeping all subsystems operating in top form and allowing for a full season data collection to be obtained. Several conclusions were drawn from the long term monitoring effort, among which are: (1) flat plate collectors will support cooling; (2) definite energy savings can be realized; and (3) more frequent periodic maintenance may be required on solar energy systems that are not custom built.

Source record↗

An analysis method for multi-component airfoils in separated flow

The multi-component airfoil program (Langley-MCARF) for attached flow is modified to accept the free vortex sheet separation-flow model program (Analytical Methods, Inc.-CLMAX). The viscous effects are incorporated into the calculation by representing the boundary layer displacement thickness with an appropriate source distribution. The separation flow model incorporated into MCARF was applied to single component airfoils. Calculated pressure distributions for angles of attack up to the stall are in close agreement with experimental measurements. Even at higher angles of attack beyond the stall, correct trends of separation, decrease in lift coefficients, and increase in pitching moment coefficients are predicted.

Rao, B. M.↗

Comparison of finite element analysis of a piping tee using NASTRAN and CORTES/SA

A comparison of finite element analyses of a piping tee was made using NASTRAN and CORTES/SA, a modified version of SAP3 having a special purpose input processor for generating geometries for a wide variety of tee joints. Four finite element models were subjected in force, moment, and pressure loadings. Flexibility factors and principal stresses were computed for each model and compared with results obtained experimentally by Combustion Engineering, Inc. Results from the NASTRAN analyses were in good agreement with experimental results for all loadings except internal pressure. The CORTES/SA analyses gave good results for the internal pressure loading, but poorer results for out of plane bending moments or forces resulting in out of plane bending. Two of the basic load cases in CORTES/SA were found to contain errors that could not be easily corrected. COST COMPARison of NASTRAN and CORTES/SA showed NASTRAN to be less expensive to two than CORTES/SA for identical meshes.

Quezon, A. J.↗

Laser propulsion - 1980

An overview of the current government sponsored work in laser propulsion is presented and the NASA program is discussed. Attention is given to the overall NASA plan in laser propulsion and the laser rocket engine technology program. Some results of an analytical effort at Physical Sciences Inc. are presented, as well as results of the NASA/Army Missile Command experimental effort. Finally, future plans are briefly summarized.

Jones, L. W.↗

Solar hot water system installed at Day's Lodge, Atlanta, Georgia

The solar energy hot water system installed in the Days Inns of America, Inc., Atlanta, Georgia is described. This system provides for 81 percent of the total hot water demand. There are two separate systems, each serving one building of the lodge (total of 65 suites). The entire system contains only potable city water. The 1024 square feet of Grumman Sunstream Model 332 liquid flat plate collectors and the outside piping drain whenever the collector plates approach freezing or when power is interrupted. Solar heated water from the two above ground cement lined steel tanks (1000 gallon tank) is drawn into the electric Domestic Hot Water (DHW) tanks as hot water is drawn. Electric resistance units in the DHW tanks top off the solar heated water, if needed, to reach thermostat setting.

Source record↗

Validation of helicopter noise prediction techniques

The current techniques of helicopter rotor noise prediction attempt to describe the details of the noise field precisely and remove the empiricisms and restrictions inherent in previous methods. These techniques require detailed inputs of the rotor geometry, operating conditions, and blade surface pressure distribution. The purpose of this paper is to review those techniques in general and the Farassat/Nystrom analysis in particular. The predictions of the Farassat/Nystrom noise computer program, using both measured and calculated blade surface pressure data, are compared to measured noise level data. This study is based on a contract from NASA to Bolt Beranek and Newman Inc. with measured data from the AH-1G Helicopter Operational Loads Survey flight test program supplied by Bell Helicopter Textron.

Succi, G. P.↗

Preliminary design of a tip-jet-driven heavy lift helicopter incorporating circulation control

This report describes a preliminary design study for a Very Heavy Lift Helicopter (VHLH) that is powered by jets at the blade tips and is controlled by circulation control applied to the main rotor blades. The main thrust of the program was to integrate a tip-jet-powered helicopter design computer program developed by Hughes Helicopters, Inc. (HHI) with circulation control data generated by the David Taylor Naval Ship Research and Development Center (DTNSRDC). This work combined the computer program integration work with an air vehicle preliminary design study to size the helicopter and describe its features. The result of this study is the sizing of a four-engined helicopter with a 185 foot diameter, two-bladed main rotor that is designed to carry the XM-1 Main Battle Tank 100 nautical miles in a ship-to-shore Marine Corps assault mission.

Head, R. E.↗

Management of optics

American Science and Engineering, Inc., designed the large X-ray optic for the HEAO-2 X-ray Telescope. The key element in this project was the High Resolution Mirror Assembly (HRMA), subcontracting the fabrication of the optical surfaces and their assembly and alignment. The roles and organization of the key participants in the creation of HRMA are defined, and the degree of interaction between the groups is described. Management of this effort was extremely complex because of the intricate weaving of responsibilities, and AS&E, as HEAO-2 Program managers, needed to be well versed in the scientific objectives, the technical requirements, the program requirements, and the subcontract management. Understanding these factors was essential for implementing both technical and management controls, such as schedule and budget constraints, in-process control, residence requirements, and scientist review and feedback. Despite unforeseen technical problems and interaction differences, the HEAO-2 was built on schedule and to specification.

Kirchner, T. E.↗

Concepted design of a surface measurement system for large deployable space antennas

The sensor system is in essence a point design, specifically interfacing with the Harris, Inc., 1000 meter deployable mesh communication antenna. The design can, without large modification, be adapted to other large deployable antennas such as the Lockheed Wrap-rib, the General Dynamics Precision Erectable Truss and the TRW Advanced Sunflower antennas. Measurements are optical displacements. The elements of the system are a central cluster of receivers near the apex of the antenna and active bright targets at the antenna. The cluster defines a single coordinate frame from which all surface positions are referenced. The receivers continuously observe an extended array of sample points located throughout the reflecting surface and its supporting structure. For the Harris antenna, the surface samples are at the mesh gore lines and at the supporting hoop. Output data is in real-time, compatible with on-board processing and active control of antenna figure. Lifetime of the system is at least 10 years continuous operation in space.

Neiswander, R. S.↗

Preprototype Vapor Compression Distillation Subsystem development

Vapor Compression Distillation (VCD) has evolved as the most promising approach to reclaim potable water from wastewater for future long-term manned space missions. Life Systems, Inc. (LSI), working with NASA, has developed a preprototype Vapor Compression Distillation Subsystem (VCDS) which processes wastewater at 1.4 kg/h. The preprototype unit weighs 143 kg, occupies a volume of 0.47 cu m, and will reclaim 96 percent of the available wastewater. This unit has been tested by LSI and is scheduled for further testing at NASA-JSC. This paper presents the preprototype VCDS design, configuration, performance data, test results and flight system projections.

Thompson, C. D.↗

Cosmic ray induced errors in I2L microprocessors and logic devices

Large-scale integrated (LSI) devices fabricated with integrated injection logic (I2L) were studied by both heavy ion experiments and device analysis to determine the upset threshold, the charge collection volumes and ultimately the probability for upset in the galactic cosmic ray spectrum. The devices studied, the SEP9900A, the SBP9989 and the P-Code generator were fabricated by Texas Instruments, Inc.

Price, W. E.↗

The Solarex Block IV module

Several innovative concepts were introduced for the Block IV contract. Semicrystalline silicon manufactured by SEMIX Inc. is the basic cell material. A front metallization pattern combined with a wraparound-style interconnect and in-plane stress relief combine to provide a new method to reliably accomplish series-paralleling. Laminated modules using Ethylene Vinyl Acetate (EVA) as the encapsulant were manufactured for the first time.

Hoelscher, J. F.↗