Results for “Image reconstruction techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Characteristics of Muon Computed Tomography of Used Fuel Casks Using Algebraic Reconstruction

Cosmic raymuons passing through matter lose energy from inelastic collisions with electrons and are deflected from nuclei due to multiple Coulomb scattering (MCS). The recent developments in position sensitive muon detectors that can measure incoming and outgoing trajectories of individual muons indicate that MCS could be an excellent candidate for spent nuclear fuel imaging. The main purpose of this paper is to evaluate tomographic scanning of spent nuclear fuel stored within vertical and horizontal dry storage casks. A quantitative analysis of the characteristics of images obtained with filtered back projection (FBP) and algebraic reconstruction techniques (ART) are presented herein, as such a comparison has not been carried out in the past. FBP is a fast tool to determine object boundaries. ART can include muon path models and prior knowledge that can improve resolution and reduce measurement time. The results demonstrate that missing fuel assemblies can be identified with more than 5 projections and that use of muon momentum significantly increases image resolution. It is expected that MCS can be used to successfully reconstruct the dry cask contents and allow identification of all described scenarios in hours. It is also expected that when total variation minimization and a non-local mean filter are applied, ART may yield much better image quality than FBP.

Liu, Zhengzhi↗

SU-G-IeP2-13: Toward Heavy Ion Computed Tomography with Carbon Ions: A Monte Carlo Study

Purpose: In the present Monte Carlo study, we investigated the use of Carbon ions for computed tomography (CT) with a relatively low imaging dose. This will enable us to avoid any conversion of X-ray CT numbers to the relative stopping power (or relative electron density) values and the associated uncertainties in Carbon dose calculation. Methods: In the first stage, we studied the propagation of Carbon nuclei through a water phantom using the Geant4 specially to understand their lateral displacement inside the phantom. In the second stage, we used our GPU-based Monte Carlo code, which has been cross validated against Geant4, to create the 2D map of the water equivalent path length (WEPL) inside a human head size phantom by acquiring 240 projections each 1.5° apart. Subsequently the 3D relative electron density map of the phantom was reconstructed from the 2D WEPL map using the Algebraic Reconstruction Technique (ART) coupled with total variation (TV) minimization Results: A high quality image of the relative electron density inside the phantom was reconstructed by ARTTV. The mean relative error between the reconstructed image for low contrast object (PMMA) was about 1.74%. The delivered dose per scan at the center of the phantom was about 0.1 Gy. Conclusion: We have been able to obtain a 3D map of the electron density using a human head size phantom while keeping the delivered dose to relatively low value. Using the GPU capabilities of our simulation engine, we believe that a real time CT with Carbon ions could be a reality in future.

60 APPLIED LIFE SCIENCES↗

Left ventricular endocardial surface detection based on real-time 3D echocardiographic data

OBJECTIVE: A new computerized semi-automatic method for left ventricular (LV) chamber segmentation is presented. METHODS: The LV is imaged by real-time three-dimensional echocardiography (RT3DE). The surface detection model, based on level set techniques, is applied to RT3DE data for image analysis. The modified level set partial differential equation we use is solved by applying numerical methods for conservation laws. The initial conditions are manually established on some slices of the entire volume. The solution obtained for each slice is a contour line corresponding with the boundary between LV cavity and LV endocardium. RESULTS: The mathematical model has been applied to sequences of frames of human hearts (volume range: 34-109 ml) imaged by 2D and reconstructed off-line and RT3DE data. Volume estimation obtained by this new semi-automatic method shows an excellent correlation with those obtained by manual tracing (r = 0.992). Dynamic change of LV volume during the cardiac cycle is also obtained. CONCLUSION: The volume estimation method is accurate; edge based segmentation, image completion and volume reconstruction can be accomplished. The visualization technique also allows to navigate into the reconstructed volume and to display any section of the volume.

Non-NASA Center↗

A Three-Dimensional Reconstruction Algorithm for Scanning Transmission Electron Microscopy Data from a Single Sample Orientation

Abstract Increasing interest in three-dimensional nanostructures adds impetus to electron microscopy techniques capable of imaging at or below the nanoscale in three dimensions. We present a reconstruction algorithm that takes as input a focal series of four-dimensional scanning transmission electron microscopy (4D-STEM) data. We apply the approach to a lead iridate, PbIrO, and yttrium-stabilized zirconia, YZrO, heterostructure from data acquired with the specimen in a single plan-view orientation, with the epitaxial layers stacked along the beam direction. We demonstrate that Pb–Ir atomic columns are visible in the uppermost layers of the reconstructed volume. We compare this approach to the alternative techniques of depth sectioning using differential phase contrast scanning transmission electron microscopy (DPC-STEM) and multislice ptychographic reconstruction.

47 OTHER INSTRUMENTATION↗

X-ray focal spot reconstruction by circular penumbra analysis—Application to digital radiography systems

Purpose: The quality of a radiography system is affected by several factors, a major one being the focal spot size of the x-ray tube. In fact, the measurement of such size is recognized to be of primary importance during acceptance tests and image quality evaluations of clinical radiography systems. The most common device providing an image of the focal spot emission distribution is a pin-hole camera, which requires a high tube loading in order to produce a measurable signal. This work introduces an alternative technique to obtain an image of the focal spot, through the processing of a single radiograph of a simple test object, acquired with a suitable magnification. Methods: The radiograph of a magnified sharp edge is a well-established method to evaluate the extension of the focal spot profile along the direction perpendicular to the edge. From a single radiograph of a circular x-ray absorber, it is possible to extract simultaneously the radial profiles of several sharp edges with different orientations. The authors propose a technique that allows to obtain an image of the focal spot through the processing of these radial profiles by means of a pseudo-CT reconstruction technique. In order to validate this technique, the reconstruction has been applied to the simulated radiographs of an ideal disk-shaped absorber, generated by various simulated focal spot distributions. Furthermore, the method has been applied to the focal spot of a commercially available mammography unit. Results: In the case of simulated radiographs, the results of the reconstructions have been compared to the original distributions, showing an excellent agreement for what regards both the overall distribution and the full width at half maximum measurements. In the case of the experimental test, the method allowed to obtain images of the focal spot that have been compared with the results obtained through standard techniques, namely, pin-hole camera and slit camera. Conclusions: The method was proven to be effective for simulated images and the results of the experimental test suggest that it could be considered as an alternative technique for focal spot distribution evaluation. The method offers the possibility to measure the actual focal spot size and emission distribution at the same exposure conditions as clinical routine, avoiding high tube loading as in the case of the pin-hole imaging technique.

61 RADIATION PROTECTION AND DOSIMETRY↗

Statistical iterative reconstruction to improve image quality for digital breast tomosynthesis

Purpose: Digital breast tomosynthesis (DBT) is a novel modality with the potential to improve early detection of breast cancer by providing three-dimensional (3D) imaging with a low radiation dose. 3D image reconstruction presents some challenges: cone-beam and flat-panel geometry, and highly incomplete sampling. A promising means to overcome these challenges is statistical iterative reconstruction (IR), since it provides the flexibility of accurate physics modeling and a general description of system geometry. The authors’ goal was to develop techniques for applying statistical IR to tomosynthesis imaging data. Methods: These techniques include the following: a physics model with a local voxel-pair based prior with flexible parameters to fine-tune image quality; a precomputed parameter λ in the prior, to remove data dependence and to achieve a uniform resolution property; an effective ray-driven technique to compute the forward and backprojection; and an oversampled, ray-driven method to perform high resolution reconstruction with a practical region-of-interest technique. To assess the performance of these techniques, the authors acquired phantom data on the stationary DBT prototype system. To solve the estimation problem, the authors proposed an optimization-transfer based algorithm framework that potentially allows fewer iterations to achieve an acceptably converged reconstruction. Results: IR improved the detectability of low-contrast and small microcalcifications, reduced cross-plane artifacts, improved spatial resolution, and lowered noise in reconstructed images. Conclusions: Although the computational load remains a significant challenge for practical development, the superior image quality provided by statistical IR, combined with advancing computational techniques, may bring benefits to screening, diagnostics, and intraoperative imaging in clinical applications.

60 APPLIED LIFE SCIENCES↗

High resolution dual detector volume-of-interest cone beam breast CT - Demonstration with a bench top system

Purpose: In this study, we used a small field high resolution detector in conjunction with a full field flat panel detector to implement and investigate the dual detector volume-of-interest (VOI) cone beam breast computed tomography (CBCT) technique on a bench-top system. The potential of using this technique to image small calcifications without increasing the overall dose to the breast was demonstrated. Significant reduction of scatter components in the high resolution projection image data of the VOI was also shown. Methods: With the regular flat panel based CBCT technique, exposures were made at 80 kVp to generate an air kerma of 6 mGys at the isocenter. With the dual detector VOI CBCT technique, a high resolution small field CMOS detector was used to scan a cylindrical VOI (2.5 cm in diameter and height, 4.5 cm off-center) with collimated x-rays at four times of regular exposure level. A flat panel detector was used for full field scan with low x-ray exposures at half of the regular exposure level. The low exposure full field image data were used to fill in the truncated space in the VOI scan data and generate a complete projection image set. The Feldkamp-Davis-Kress (FDK) filtered backprojection algorithm was used to reconstruct high resolution images for the VOI. Two scanning techniques, one breast centered and the other VOI centered, were implemented and investigated. Paraffin cylinders with embedded thin aluminum (Al) wires were imaged and used in conjunction with optically stimulated luminescence (OSL) dose measurements to demonstrate the ability of this technique to image small calcifications without increasing the mean glandular dose (MGD). Results: Using exposures that produce an air kerma of 6 mGys at the isocenter, the regular CBCT technique was able to resolve the cross-sections of Al wires as thin as 254 {mu}m in diameter in the phantom. For the specific VOI studied, by increasing the exposure level by a factor of 4 for the VOI scan and reducing the exposure level by a factor of 2 for the full filed scan, the dual-detector CBCT technique was able to resolve the cross-sections of Al wires as thin as 152 {mu}m in diameter. The CNR evaluated for the entire Al wire cross-section was found to be improved from 5.5 in regular CBCT to 14.4 and 16.8 with the breast centered and VOI centered scanning techniques, respectively. Even inside VOI center, the VOI scan resulted in significant dose saving with the dose reduced by a factor of 1.6 at the VOI center. Dose saving outside the VOI was substantial with the dose reduced by a factor of 7.3 and 7.8 at the breast center for the breast centered and VOI centered scans, respectively, when compared to full field scan at the same exposure level. The differences between the two dual detector techniques in terms of dose saving and scatter reduction were small with VOI scan at 4x exposure level and full field scan at 0.5x exposure level. The MGDs were only 94% of that from the regular CBCT scan. Conclusions: For the specific VOI studied, the dual detector VOI CBCT technique has the potential to provide high quality images inside the VOI with MGD similar to or even lower than that of full field breast CBCT. It was also found that our results were compromised by the use of inadequate detectors for the VOI scan. An appropriately selected detector would better optimize the image quality improvement that can be achieved with the VOI CBCT technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress Implementing a Model-Based Iterative Reconstruction Algorithm for Ultrasound Imaging of Thick Concrete

All commercial nuclear power plants (NPPs) in the United States contain concrete structures. These structures provide important foundation, support, shielding, and containment functions. Identification and management of aging and the degradation of concrete structures is fundamental to the proposed long-term operation of NPPs. Concrete structures in NPPs are often inaccessible and contain large volumes of massively thick concrete. While acoustic imaging using the synthetic aperture focusing technique (SAFT) works adequately well for thin specimens of concrete such as concrete transportation structures, enhancements are needed for heavily reinforced, thick concrete. We argue that image reconstruction quality for acoustic imaging in thick concrete could be improved with Model-Based Iterative Reconstruction (MBIR) techniques. MBIR works by designing a probabilistic model for the measurements (forward model) and a probabilistic model for the object (prior model). Both models are used to formulate an objective function (cost function). The final step in MBIR is to optimize the cost function. Previously, we have demonstrated a first implementation of MBIR for an ultrasonic transducer array system. The original forward model has been upgraded to account for direct arrival signal. Updates to the forward model will be documented and the new algorithm will be assessed with synthetic and empirical samples.

concrete NDE↗

Evaluation of the Reconstruction Accuracy of the Ultrasound Model–Based Image Reconstruction (U-MBIR) Method for Concrete to Optimize Damage Detection

Reinforced concrete is a critical structural material used to construct nuclear power plants (NPPs). As such, its safety and performance must be thoroughly examined throughout the life cycle of the NPP infrastructure system. Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. To support the development of these techniques, Oak Ridge National Laboratory (ORNL) has researched and developed advanced image reconstruction algorithms to capture internal damage. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL. In the work documented in this report, the U-MBIR methodology was applied to four sets of ultrasonic data collected from concrete specimens. The results demonstrate that the U-MBIR algorithm can successfully detect defects within the four concrete samples. The reconstruction images help identify the specimen thickness, regions of delamination, and location of rebar embedded within the concrete. The reconstruction images allow engineers and technicians to characterize the internal defects within concrete specimens and structural members. Ultimately, this knowledge can guide engineers in making informed decisions regarding the performance, safety, and reliability of structural materials (i.e., reinforced concrete) throughout the life cycle of NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Image sharpening for mixed spatial and spectral resolution satellite systems

Two methods of image sharpening (reconstruction) are compared. The first, a spatial filtering technique, extrapolates edge information from a high spatial resolution panchromatic band at 10 meters and adds it to the low spatial resolution narrow spectral bands. The second method, a color normalizing technique, is based on the ability to separate image hue and brightness components in spectral data. Using both techniques, multispectral images are sharpened from 30, 50, 70, and 90 meter resolutions. Error rates are calculated for the two methods and all sharpened resolutions. The results indicate that the color normalizing method is superior to the spatial filtering technique.

Hallada, W. A.↗

Structure of unsteady flows at leading- and trailing-edges: Flow visualization and its interpretation

Unsteady two- and three-dimensional flow structure at leading and trailing edges of bodies can be characterized effectively using recently developed techniques for acquisition and interpretation of flow visualization. The techniques addressed here include: flow image/surface pressure correlations; 3-D reconstruction of flow structure from flow images; and interactive interpretation of flow images with theoretical simulations. These techniques can be employed in conjunction with: visual correlation and ensemble-averaging, both within a given image and between images; recognition of patterns from images; and estimates of velocity eigenfunctions from images.

Rockwell, D.↗

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Tomographic Imaging of Glass/Epoxy Composite with a Laser Based Ultrasonics Setup

The present work is an attempt to augment the classical laser-based-ultrasonics setup for tomographic imaging purposes. A Glass/epoxy composite with steel insert is the test specimen and time-of-flight data has been used for tomographic reconstruction. Multiplicative algebraic reconstruction technique is used for this limited-view experiment. The resulting image is able to bring out the strong metal features.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Broadband X-ray ptychography using multi-wavelength algorithm

Ptychography is a rapidly developing scanning microscopy which is able to view the internal structures of samples at a high resolution beyond the illumination size. The achieved spatial resolution is theoretically dose-limited. A broadband source can provide much higher flux compared with a monochromatic source; however, it conflicts with the necessary coherence requirements of this coherent diffraction imaging technique. In this paper, a multi-wavelength reconstruction algorithm has been developed to deal with the broad bandwidth in ptychography. Compared with the latest development of mixed-state reconstruction approach, this multi-wavelength approach is more accurate in the physical model, and also considers the spot size variation as a function of energy due to the chromatic focusing optics. Therefore, this method has been proved in both simulation and experiment to significantly improve the reconstruction when the source bandwidth, illumination size and scan step size increase. It is worth mentioning that the accurate and detailed information of the energy spectrum for the incident beam is not required in advance for the proposed method. Further, we combine multi-wavelength and mixed-state approaches to jointly solve temporal and spatial partial coherence in ptychography so that it can handle various disadvantageous experimental effects. The significant relaxation in coherence requirements by our approaches allows the use of high-flux broadband X-ray sources for high-efficient and high-resolution ptychographic imaging.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Isotope specific resolution recovery image reconstruction in high resolution PET imaging

Purpose: Measuring and incorporating a scanner-specific point spread function (PSF) within image reconstruction has been shown to improve spatial resolution in PET. However, due to the short half-life of clinically used isotopes, other long-lived isotopes not used in clinical practice are used to perform the PSF measurements. As such, non-optimal PSF models that do not correspond to those needed for the data to be reconstructed are used within resolution modeling (RM) image reconstruction, usually underestimating the true PSF owing to the difference in positron range. In high resolution brain and preclinical imaging, this effect is of particular importance since the PSFs become more positron range limited and isotope-specific PSFs can help maximize the performance benefit from using resolution recovery image reconstruction algorithms. Methods: In this work, the authors used a printing technique to simultaneously measure multiple point sources on the High Resolution Research Tomograph (HRRT), and the authors demonstrated the feasibility of deriving isotope-dependent system matrices from fluorine-18 and carbon-11 point sources. Furthermore, the authors evaluated the impact of incorporating them within RM image reconstruction, using carbon-11 phantom and clinical datasets on the HRRT. Results: The results obtained using these two isotopes illustrate that even small differences in positron range can result in different PSF maps, leading to further improvements in contrast recovery when used in image reconstruction. The difference is more pronounced in the centre of the field-of-view where the full width at half maximum (FWHM) from the positron range has a larger contribution to the overall FWHM compared to the edge where the parallax error dominates the overall FWHM. Conclusions: Based on the proposed methodology, measured isotope-specific and spatially variant PSFs can be reliably derived and used for improved spatial resolution and variance performance in resolution recovery image reconstruction. The benefits are expected to be more substantial for more energetic positron emitting isotopes such as Oxygen-15 and Rubidium-82.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterization of a constrained paired-view technique in iterative reconstruction for breast tomosynthesis

Purpose: The order in which the projection views are employed in the reconstruction of tomosynthesis by iterative algorithms, such as simultaneous algebraic reconstruction technique and maximum likelihood, has a strong effect on the rate of convergence, accuracy, and the edge-blurring artifacts in the reconstructed image. The purpose of this investigation was to characterize and evaluate the effects of ordering schemes on image quality for breast tomosynthesis reconstruction and to explore a new constrained paired-view technique that could provide reduction of reconstruction artifacts. In this work, the authors compared several different ordering schemes and characterized the image quality and the formation of out-of-plane artifacts. Furthermore, a new normalization method is presented. It produces more accurate reconstructions with reduced artifacts comparing to the standard method of sequential ordering.Methods: In addition to visual assessment of image quality, several indices such as the signal-difference-to-noise ratio, the artifact-spread function, and the lesion detectability (d{sup ′}) were computed to quantitatively evaluate the effect of ordering scheme. The sets of breast tomosynthesis projection images were simulated for reconstruction; one set had uniform background (white noise only) and the other two contained both anatomic background and quantum noise. Clinical breast images were also studied for comparison.Results: The authors have quantified the image quality in reconstructed slices for a range of tumor sizes. The authors’ proposed method provides better performance for all of the metrics tested (contrast, d{sup ′}, and the level of artifacts) both for the uniform phantom case and in the presence of anatomical structure.Conclusions: The paired projection normalization provides better performance in the image quality of the reconstructed slices, and results in a lower level of artifacts in the Z direction. This implies that even a relatively simple method like the “side-to-side” sequence, which pairs two symmetrical projections with equal angular distance from the central projection, would achieve better reconstructed image quality than the conventional “step-by-step” method, which uses sequential projections one after another.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-207-04: Non-Local Total-Variation (NLTV) Combined with Reweighted L1-Norm for Compressed Sensing Based CT Reconstruction

Purpose: Compressed sensing (CS) has been used for CT (4DCT/CBCT) reconstruction with few projections to reduce dose of radiation. Total-variation (TV) in L1-minimization (min.) with local information is the prevalent technique in CS, while it can be prone to noise. To address the problem, this work proposes to apply a new image processing technique, called non-local TV (NLTV), to CS based CT reconstruction, and incorporate reweighted L1-norm into it for more precise reconstruction. Methods: TV minimizes intensity variations by considering two local neighboring voxels, which can be prone to noise, possibly damaging the reconstructed CT image. NLTV, contrarily, utilizes more global information by computing a weight function of current voxel relative to surrounding search area. In fact, it might be challenging to obtain an optimal solution due to difficulty in defining the weight function with appropriate parameters. Introducing reweighted L1-min., designed for approximation to ideal L0-min., can reduce the dependence on defining the weight function, therefore improving accuracy of the solution. This work implemented the NLTV combined with reweighted L1-min. by Split Bregman Iterative method. For evaluation, a noisy digital phantom and a pelvic CT images are employed to compare the quality of images reconstructed by TV, NLTV and reweighted NLTV. Results: In both cases, conventional and reweighted NLTV outperform TV min. in signal-to-noise ratio (SNR) and root-mean squared errors of the reconstructed images. Relative to conventional NLTV, NLTV with reweighted L1-norm was able to slightly improve SNR, while greatly increasing the contrast between tissues due to additional iterative reweighting process. Conclusion: NLTV min. can provide more precise compressed sensing based CT image reconstruction by incorporating the reweighted L1-norm, while maintaining greater robustness to the noise effect than TV min.

60 APPLIED LIFE SCIENCES↗