Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Backscatter x-ray development for space vehicle thermal protection systems

The Backscatter X-Ray (BSX) imaging technique is used for various single sided inspection purposes. Previously developed BSX techniques for spray-on-foam insulation (SOFI) have been used for detecting defects in Space Shuttle External Tank foam insulation. The developed BSX hardware and techniques are currently being enhanced to advance Non-Destructive Evaluation (NDE) methods for future space vehicle applications. Various Thermal Protection System (TPS) materials were inspected using the enhanced BSX imaging techniques, investigating the capability of the method to detect voids and other discontinuities at various locations within each material. Calibration standards were developed for the TPS materials in order to characterize and develop enhanced BSX inspection capabilities. The ability of the BSX technique to detect both manufactured and natural defects was also studied and compared to through-transmission x-ray techniques. The energy of the x-ray, source to object distance, angle of x-ray, focal spot size and x-ray detector configurations were parameters playing a significant role in the sensitivity of the BSX technique to image various materials and defects. The image processing of the results also showed significant increase in the sensitivity of the technique. The experimental results showed BSX to be a viable inspection technique for space vehicle TPS systems.

07 ISOTOPE AND RADIATION SOURCES↗

Synchrotron X-ray based particle image velocimetry to measure multiphase streamflow and densitometry

Synchrotron-based radiation techniques are increasingly used in the field of flow condition measurements. As a complicated multiphase flow, cavitation has been investigated in a wide variety of industrial fields, to prevent damages on spillways at large dams or intensify the bacteria eradication rate during water treatments. To control the detrimental effects of cavitating flows, the dynamics of and mechanisms affecting cavitation development shall be visualized and identified in real-time. Due to the large reflection and scattering effects of multiphase flow, standard visible-light imaging technologies cannot penetrate vapor bubbles and provide extremely limited information. In this study, the synchrotron source emitted high-flux X-ray pulses are used to capture flow motion and visualize internal structures with sufficiently high spatial and temporal resolutions. The image processing procedures on raw x-ray images are developed using 2D Fourier transform (FT) and wavelet transform (WT) to implement the contrast enhancement and de-noising. Through the edge detection algorithm, tracking either seeded particles or phase interfaces inside the opaque multiphase flow can be achieved to perform the particle image velocimetry. Further, with decomposing particle-only and particle-eliminated subplots from the X-ray phase-contrast image, the time-resolved velocity and void fraction fields are obtained simultaneously, paving a way for further flow condition analysis such as densitometry.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The simulation of 3D microcalcification clusters in 2D digital mammography and breast tomosynthesis

Purpose: This work proposes a new method of building 3D models of microcalcification clusters and describes the validation of their realistic appearance when simulated into 2D digital mammograms and into breast tomosynthesis images. Methods: A micro-CT unit was used to scan 23 breast biopsy specimens of microcalcification clusters with malignant and benign characteristics and their 3D reconstructed datasets were segmented to obtain 3D models of microcalcification clusters. These models were then adjusted for the x-ray spectrum used and for the system resolution and simulated into 2D projection images to obtain mammograms after image processing and into tomographic sequences of projection images, which were then reconstructed to form 3D tomosynthesis datasets. Six radiologists were asked to distinguish between 40 real and 40 simulated clusters of microcalcifications in two separate studies on 2D mammography and tomosynthesis datasets. Receiver operating characteristic (ROC) analysis was used to test the ability of each observer to distinguish between simulated and real microcalcification clusters. The kappa statistic was applied to assess how often the individual simulated and real microcalcification clusters had received similar scores (''agreement'') on their realistic appearance in both modalities. This analysis was performed for all readers and for the real and the simulated group of microcalcification clusters separately. ''Poor'' agreement would reflect radiologists' confusion between simulated and real clusters, i.e., lesions not systematically evaluated in both modalities as either simulated or real, and would therefore be interpreted as a success of the present models. Results: The area under the ROC curve, averaged over the observers, was 0.55 (95% confidence interval [0.44, 0.66]) for the 2D study, and 0.46 (95% confidence interval [0.29, 0.64]) for the tomosynthesis study, indicating no statistically significant difference between real and simulated lesions (p > 0.05). Agreement between allocated lesion scores for 2D mammography and those for the tomosynthesis series was poor. Conclusions: The realistic appearance of the 3D models of microcalcification clusters, whether malignant or benign clusters, was confirmed for 2D digital mammography images and the breast tomosynthesis datasets; this database of clusters is suitable for use in future observer performance studies related to the detectability of microcalcification clusters. Such studies include comparing 2D digital mammography to breast tomosynthesis and comparing different reconstruction algorithms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

A high-precision instrument for analyzing nonlinear dynamic behavior of bearing cage

The high-precision ball bearing is fundamental to the performance of complex mechanical systems. As the speed increases, the cage behavior becomes a key factor in influencing the bearing performance, especially life and reliability. This paper develops a high-precision instrument for analyzing nonlinear dynamic behavior of the bearing cage. The trajectory of the rotational center and non-repetitive run-out (NRRO) of the cage are used to evaluate the instability of cage motion. This instrument applied an aerostatic spindle to support and spin test the bearing to decrease the influence of system error. Then, a high-speed camera is used to capture images when the bearing works at high speeds. A 3D trajectory tracking software TEMA Motion is used to track the spot which marked the cage surface. Finally, by developing the MATLAB program, a Lissajous’ figure was used to evaluate the nonlinear dynamic behavior of the cage with different speeds. The trajectory of rotational center and NRRO of the cage with various speeds are analyzed. The results can be used to predict the initial failure and optimize cage structural parameters. In addition, the repeatability precision of instrument is also validated. In the future, the motorized spindle will be applied to increase testing speed and image processing algorithms will be developed to analyze the trajectory of the cage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SYSTEMATIC DE-SATURATION OF IMAGES FROM THE ATMOSPHERIC IMAGING ASSEMBLY IN THE SOLAR DYNAMICS OBSERVATORY

Extreme ultraviolet (EUV) images of solar flares provided by the Atmospheric Imaging Assembly (AIA) on board the Solar Dynamics Observatory (SDO) are often affected by saturation effects in their core, physically most interesting, region. We introduce an image reconstruction procedure that allows recovering information in the primary saturation domain using the secondary images produced by the diffraction fringes as input data. Such a procedure is based on standard image-processing tools like correlation, convolution, and back-projection. Its effectiveness is tested in the case of AIA/SDO observations of the 2013 July 8 flaring event.

79 ASTRONOMY AND ASTROPHYSICS↗

Bayesian K-SVD Using Fast Variational Inference

Recent work in signal processing in general and image processing in particular deals with sparse representation related problems. Two such problems are of paramount importance: an overriding need for designing a well-suited overcomplete dictionary containing a redundant set of atoms— i.e., basis signals—and how to find a sparse representation of a given signal with respect to the chosen dictionary. Dictionary learning techniques, among which we find the popular K-singular value decomposition algorithm, tackle these problems by adapting a dictionary to a set of training data. A common drawback of such techniques is the need for parameter-tuning. In order to overcome this limitation, we propose a fullyautomated Bayesian method that considers the uncertainty of the estimates and produces a sparse representation of the data without prior information on the number of non-zeros in each representation vector. We follow a Bayesian approach that uses a three-tiered hierarchical prior to enforce sparsity on the representations and develop an efficient variational inference framework that reduces computational complexity. Furthermore, we describe a greedy approach that speeds up the whole process. Lastly, we present experimental results that show superior performance on two different applications with real images: denoising and inpainting.

97 MATHEMATICS AND COMPUTING↗

BrachyView, a novel in-body imaging system for HDR prostate brachytherapy: Experimental evaluation

Purpose: This paper presents initial experimental results from a prototype of high dose rate (HDR) BrachyView, a novel in-body source tracking system for HDR brachytherapy based on a multipinhole tungsten collimator and a high resolution pixellated silicon detector array. The probe and its associated position estimation algorithms are validated and a comprehensive evaluation of the accuracy of its position estimation capabilities is presented. Methods: The HDR brachytherapy source is moved through a sequence of positions in a prostate phantom, for various displacements in x, y, and z. For each position, multiple image acquisitions are performed, and source positions are reconstructed. Error estimates in each dimension are calculated at each source position and combined to calculate overall positioning errors. Gafchromic film is used to validate the accuracy of source placement within the phantom. Results: More than 90% of evaluated source positions were estimated with an error of less than one millimeter, with the worst-case error being 1.3 mm. Experimental results were in close agreement with previously published Monte Carlo simulation results. Conclusions: The prototype of HDR BrachyView demonstrates a satisfactory level of accuracy in its source position estimation, and additional improvements are achievable with further refinement of HDR BrachyView’s image processing algorithms.

60 APPLIED LIFE SCIENCES↗

SU-E-J-46: Evaluation of the Accuracy of a Six Degree of Freedom Robotic Couch Using ConeBeam CT Images of the Isocal Phantom

Purpose The accuracy of Varian PerfectPitch six degree of freedom (DOF) robotic couch was examined using Varian Isocal phantom and cone-beam CT (CBCT) system. Methods CBCT images of the Isocal phantom were taken at different pitch and roll angles. The pitch and roll angles were varied from 357 to 3 degrees in one degree increments by input from service console, generating a total of 49 combinations with couch angle (yaw) zero. The center positions of the 16 tungsten carbide BBs contained in the Isocal were determined with in-house image processing software. Expected BBs positions at different rotation angles were determined mathematically by applying a combined translation/rotation operator to BB positions at zero pitch and roll values. A least square method was used to minimize the difference between the expected BB positions and their measured positions. In this way rotation angles were obtained and compared with input values from the console. Results A total of 49 CBCT images with voxel sizes 0.51 mm × 0.51 mm × 1 mm were used in analysis. Among the 49 calculations, the maximum rotation angle differences were 0.1 degree, 0.15 degree, and 0.09 degree, for pitch, roll, and couch rotation, respectively. The mean ± standard-deviation angle differences were 0.028±0.001 degree, −0.043±0.003 degree, and −0.009±0.001 degree, for pitch, roll, and couch rotation, respectively. The maximum isocenter shifts were 0.3 mm, 0.5 mm, 0.4 mm in x, y, z direction respectively following IEC6127 convention. The mean isocenter shifts were 0.07±0.02 mm, −0.05±0.06 mm, and −0.12±0.02 mm in x, y and z directions. Conclusion The accuracy of the Varian PerfectPitch six DOF couch was studied with CBCTs of the Isocal phantom. The rotational errors were less than 0.15 degree and isocenter shifts were less than 0.5 mm in any direction. This accuracy is sufficient for stereotactic radiotherapy clinical applications.

60 APPLIED LIFE SCIENCES↗

Simulation of Laser Ultrasonics for Detection of Surface-Connected Rail Defects

Laser ultrasonic produces frequencies in the MHz range, enabling high accuracy and a strong ability to detect rail surface defects. This paper mainly studied on the simulation of detecting surface-connected rail defects on 60 kg rails with laser ultrasonic, established the finite element model of laser-excited ultrasonic Rayleigh wave, carried out the simulation, and verified the effectiveness of the technology through experiments. To solve the problem that laser ultrasonic is insensitive to the width of defects in actual detection, and unable to make quantitative detection of defects, this paper established a new model on the basis of improving the original model that has been verified, exciting ultrasonic at the two sides at the same time of a rail with two staggered beams of laser separately to detect irregular scratch defects on rail surface, and two groups of signal data were received through two probes. Each group of data can present the half-profile information of defects, and further form two detection images of the defect. At last, the two detection images were combined into a complete image through image processing. The results of the experiment indicate that the technology studied offers a new method for the effective quantitative detection of surface-connected defects on rail.

42 ENGINEERING↗

Fully depleted CMOS pixel sensor development and potential applications

CMOS pixel sensors are often opposed to hybrid pixel sensors due to their very different sensitive layer. In standard CMOS imaging processes, a thin (about 20 μm) low resistivity epitaxial layer acts as the sensitive volume and charge collection is mostly driven by thermal agitation. In contrast, the so-called hybrid pixel technology exploits a thick (typically 300 μm) silicon sensor with high resistivity allowing for the depletion of this volume, hence charges drift toward collecting electrodes. But this difference is fading away with the recent availability of some CMOS imaging processes based on a relatively thick (about 50 μm) high resistivity epitaxial layer which allows for full depletion. This evolution extents the range of applications for CMOS pixel sensors where their known assets, high sensitivity and granularity combined with embedded signal treatment, could potentially foster breakthrough in detection performances for specific scientific instruments. One such domain is the Xray detection for soft energies, typically below 10 keV, where the thin sensitive layer was previously severely impeding CMOS sensor usage. Another application becoming realistic for CMOS sensors, is the detection in environment with a high fluence of non-ionizing radiation, such as hadron colliders. However, when considering highly demanding applications, it is still to be proven that micro-circuits required to uniformly deplete the sensor at the pixel level, do not mitigate the sensitivity and efficiency required. Prototype sensors in two different technologies with resistivity higher than 1 kΩ, sensitive layer between 40 and 50 μm and featuring pixel pitch in the range 25 to 50 μm, have been designed and fabricated. Various biasing architectures were adopted to reach full depletion with only a few volts. Laboratory investigations with three types of sources (X-rays, β-rays and infrared light) demonstrated the validity of the approach with respect to depletion, keeping a low noise figure. Especially, an energy resolution of about 400 eV for 5 keV X-rays was obtained for single pixels. The prototypes have then been exposed to gradually increased fluences of neutrons, from 10{sup 13} to 5x10{sup 14} neq/cm{sup 2}. Again laboratory tests allowed to evaluate the signal over noise persistence on the different pixels implemented. Currently our development mostly targets the detection of soft X-rays, with the ambition to develop a pixel sensor matching counting rates as affordable with hybrid pixel sensors, but with an extended sensitivity to low energy and finer pixel about 25 x 25 μm{sup 2}. The original readout architecture proposed relies on a two tiers chip. The first tier consists of a sensor with a modest dynamic in order to insure low noise performances required by sensitivity. The interconnected second tier chip enhances the read-out speed by introducing massive parallelization. Performances reachable with this strategy combining counting and integration will be detailed. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Image-based tracking system for vibration measurement of a rotating object using a laser scanning vibrometer

An image-based tracking system using laser scanning vibrometer is developed for vibration measurement of a rotating object. The proposed system unlike a conventional one can be used where the position or velocity sensor such as an encoder cannot be attached to an object. An image processing algorithm is introduced to detect a landmark and laser beam based on their colors. Then, through using feedback control system, the laser beam can track a rotating object.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-E-J-141: Comparison of Dose Calculation On Automatically Generated MRBased ED Maps and Corresponding Patient CT for Clinical Prostate EBRT Plans

Purpose: To analyze the effect of computing radiation dose on automatically generated MR-based simulated CT images compared to true patient CTs. Methods: Six prostate cancer patients received a regular planning CT for RT planning as well as a conventional 3D fast-field dual-echo scan on a Philips 3.0T Achieva, adding approximately 2 min of scan time to the clinical protocol. Simulated CTs (simCT) where synthesized by assigning known average CT values to the tissue classes air, water, fat, cortical and cancellous bone. For this, Dixon reconstruction of the nearly out-of-phase (echo 1) and in-phase images (echo 2) allowed for water and fat classification. Model based bone segmentation was performed on a combination of the DIXON images. A subsequent automatic threshold divides into cortical and cancellous bone. For validation, the simCT was registered to the true CT and clinical treatment plans were re-computed on the simCT in pinnacle{sup 3}. To differentiate effects related to the 5 tissue classes and changes in the patient anatomy not compensated by rigid registration, we also calculate the dose on a stratified CT, where HU values are sorted in to the same 5 tissue classes as the simCT. Results: Dose and volume parameters on PTV and risk organs as used for the clinical approval were compared. All deviations are below 1.1%, except the anal sphincter mean dose, which is at most 2.2%, but well below clinical acceptance threshold. Average deviations are below 0.4% for PTV and risk organs and 1.3% for the anal sphincter. The deviations of the stratifiedCT are in the same range as for the simCT. All plans would have passed clinical acceptance thresholds on the simulated CT images. Conclusion: This study demonstrated the clinical usability of MR based dose calculation with the presented Dixon acquisition and subsequent fully automatic image processing. N. Schadewaldt, H. Schulz, M. Helle and S. Renisch are employed by Phlips Technologie Innovative Techonologies, a subsidiary of Royal Philips NV.

60 APPLIED LIFE SCIENCES↗

Radiation shielding properties of barite coated fabric by computer programme

With the development of technology radiation started to be used in variety of different fields. As the radiation is hazardous for human health, it is important to keep radiation dose as low as possible. This is done mainly using shielding materials. Barite is one of the important materials in this purpose. As the barite is not used directly it can be used in some other materials such as fabric. For this purposes barite has been coated on fabric in order to improve radiation shielding properties of fabric. Determination of radiation shielding properties of coated fabric has been done by using computer program written C# language. With this program the images obtained from digital Rontgen films is used to determine radiation shielding properties in terms of image processing numerical values. Those values define radiation shielding and in this way the coated barite effect on radiation shielding properties of fabric has been obtained.

07 ISOTOPE AND RADIATION SOURCES↗

Threshold selection for classification of MR brain images by clustering method

Given a grey-intensity image, our method detects the optimal threshold for a suitable binarization of MR brain images. In MR brain image processing, the grey levels of pixels belonging to the object are not substantially different from the grey levels belonging to the background. Threshold optimization is an effective tool to separate objects from the background and further, in classification applications. This paper gives a detailed investigation on the selection of thresholds. Our method does not use the well-known method for binarization. Instead, we perform a simple threshold optimization which, in turn, will allow the best classification of the analyzed images into healthy and multiple sclerosis disease. The dissimilarity (or the distance between classes) has been established using the clustering method based on dendrograms. We tested our method using two classes of images: the first consists of 20 T2-weighted and 20 proton density PD-weighted scans from two healthy subjects and from two patients with multiple sclerosis. For each image and for each threshold, the number of the white pixels (or the area of white objects in binary image) has been determined. These pixel numbers represent the objects in clustering operation. The following optimum threshold values are obtained, T = 80 for PD images and T = 30 for T2w images. Each mentioned threshold separate clearly the clusters that belonging of the studied groups, healthy patient and multiple sclerosis disease.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

AUTOMATIC DETECTION AND TRACKING OF CORONAL MASS EJECTIONS. II. MULTISCALE FILTERING OF CORONAGRAPH IMAGES

Studying coronal mass ejections (CMEs) in coronagraph data can be challenging due to their diffuse structure and transient nature, and user-specific biases may be introduced through visual inspection of the images. The large amount of data available from the Solar and Heliospheric Observatory (SOHO), Solar TErrestrial RElations Observatory (STEREO), and future coronagraph missions also makes manual cataloging of CMEs tedious, and so a robust method of detection and analysis is required. This has led to the development of automated CME detection and cataloging packages such as CACTus, SEEDS, and ARTEMIS. Here, we present the development of a new CORIMP (coronal image processing) CME detection and tracking technique that overcomes many of the drawbacks of current catalogs. It works by first employing the dynamic CME separation technique outlined in a companion paper, and then characterizing CME structure via a multiscale edge-detection algorithm. The detections are chained through time to determine the CME kinematics and morphological changes as it propagates across the plane of sky. The effectiveness of the method is demonstrated by its application to a selection of SOHO/LASCO and STEREO/SECCHI images, as well as to synthetic coronagraph images created from a model corona with a variety of CMEs. The algorithms described in this article are being applied to the whole LASCO and SECCHI data sets, and a catalog of results will soon be available to the public.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-complexity atlas-based prostate segmentation by combining global, regional, and local metrics

Purpose: To improve the efficiency of atlas-based segmentation without compromising accuracy, and to demonstrate the validity of the proposed method on MRI-based prostate segmentation application. Methods: Accurate and efficient automatic structure segmentation is an important task in medical image processing. Atlas-based methods, as the state-of-the-art, provide good segmentation at the cost of a large number of computationally intensive nonrigid registrations, for anatomical sites/structures that are subject to deformation. In this study, the authors propose to utilize a combination of global, regional, and local metrics to improve the accuracy yet significantly reduce the number of required nonrigid registrations. The authors first perform an affine registration to minimize the global mean squared error (gMSE) to coarsely align each atlas image to the target. Subsequently, atarget-specific regional MSE (rMSE), demonstrated to be a good surrogate for dice similarity coefficient (DSC), is used to select a relevant subset from the training atlas. Only within this subset are nonrigid registrations performed between the training images and the target image, to minimize a weighted combination of gMSE and rMSE. Finally, structure labels are propagated from the selected training samples to the target via the estimated deformation fields, and label fusion is performed based on a weighted combination of rMSE and local MSE (lMSE) discrepancy, with proper total-variation-based spatial regularization. Results: The proposed method was applied to a public database of 30 prostate MR images with expert-segmented structures. The authors’ method, utilizing only eight nonrigid registrations, achieved a performance with a median/mean DSC of over 0.87/0.86, outperforming the state-of-the-art full-fledged atlas-based segmentation approach of which the median/mean DSC was 0.84/0.82 when applying to their data set. Conclusions: The proposed method requires a fixed number of nonrigid registrations, independent of atlas size, providing desirable scalability especially important for a large or growing atlas. When applied to prostate segmentation, the method achieved better performance to the state-of-the-art atlas-based approaches, with significant improvement in computation efficiency. The proposed rationale of utilizing jointly global, regional, and local metrics, based on the information characteristic and surrogate behavior for registration and fusion subtasks, can be extended naturally to similarity metrics beyond MSE, such as correlation or mutual information types.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A quantum algorithm for string matching

Algorithms that search for a pattern within a larger data-set appear ubiquitously in text and image processing. Here, we present an explicit, circuit-level implementation of a quantum pattern-matching algorithm that matches a search string (pattern) of length M inside a longer text of length N. Our algorithm has a time complexity of $\tildeO$($\sqrt{N}$), while the space complexity remains modest at O(N+ M). We report the quantum gate counts relevant for both pre-fault-tolerant and fault-tolerant regimes.

Physics↗