Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ground-Based Centimeter, Millimeter, and Submillimeter Observations of Recent Comets

Comets provide important clues to the physical and chemical processes that occurred during the formation and early evolution of the Solar System, and could also have been important for initiating prebiotic chemistry on the early Earth [I]. Comets are comprised of molecular ices, that may be pristine interstellar remnants of Solar System formation, along with high-temperature crystalline silicate dust that is indicative of a more thermally varied history in the protosolar nebula [2]. Comparing abundances of cometary parent volatiles, and isotopic fractionation ratios, to those found in the interstellar medium, in disks around young stars, and between cometary families, is vital to understanding planetary system formation and the processing history experienced by organic matter in the so-called interstellar-comet connection [3]. In the classical picture, the long-period comets probably formed in the nebular disk across the giant planet formation region (5-40 AU) with the majority of them originating from the Uranus-Neptune region. They were subsequently scattered out to the Oort Cloud (OC) by Jupiter. The short-period comets (also known as ecliptic or Jupiter Family Comets - JFC) reside mainly in the Edgeworth-Kuiper belt where they were formed. Given the gradient in physical conditions expected across this region of the nebula, chemical diversity in this comet population is to be expected [4,5]. We have conducted observations of comets I 03P/Hartley 2 (JFC) and C/2009 PI (Garradd) (OC), at primarily millimeter and submillimeter wavelengths, to determine important cosmogonic quantities, such as the ortho:para ratio and isotope ratios, as well as probe the origin of cometary organics and if they vary between the two dynamic reservoirs.

Milam, S. N.↗

Results of partial melting experiments on chondritic precursors of basaltic achondrites

Recent partial melting experiments on Murchison produced eucrite like glasses at reducing conditions. Although the glasses were remarkably similar to eucrites, the Fe/Mn ratio of the glasses was too high and the O isotopes cannot match eucrites. Mixing 70% H chondrite with 30% CM chondrite makes a potential precursor that satisfies the O isotope constraint on the eucrites. From experiments on both synthetic Murchison and a simplified version of the H70-CM30 mixture, simple partial melting of any individual or combination of known chondritic meteorites is incapable of producing eucritic glasses that have the appropriate Fe/Mn, Fe/(Fe + Mg), and O isotope ratios. In order to satisfy the Fe-Mn-Mg constraints imposed by the eucrites, both reduction of FeO to Fe-metal and olivine fractionation must occur in the precursor before partial melting is allowed to occur and produce the eucritic glass. To test this hypothesis, partial melting experiments on both Murchison and a mixture of 70% Allegan (H6)-30% Murchison (CM2) were conducted. The results of these new experiments show that to satisfy the O isotopes, Fe/Mn ratio, and Fe/(Fe + Mg) ratio, approximately 12% reduction of FeO to Fe-metal (in the silicate portion) and 20% olivine fractionation is required within the H-CM precursor to permit the formation of eucrites by partial melting. The sequence of FeO reduction and mantle fractionation permits very eucritic glasses to be produced. The problem that many remain with the H-CM precursor, however, is an overabundance of alkali elements. Correlations between temperature, O fugacity, and composition have also been found within our experiments. A basaltic achondrite precursor formed by mixing H and CM chondrites and constrained by O isotopes and Fe-Mn-Mg is compatible with a model of natural eucrites having formed by partial melting after metal and olivine fractionation in that precursor.

Boesenberg, J. S.↗

Spatially Resolved Characterisation of Low Mass Fraction Uranium Glass Working Reference Materials

Here, we present the results of a study to generate reference glasses that reflect an environment analogous to historic nuclear fallout samples of interest for post-detonation nuclear forensics. The glasses were generated by melting and then quenching SiO 2 , Al 2 O 3 and CaCO 3 powders. Two suites of glasses with three distinct U isotopic ratios were successfully made with enrichments in the 235 U isotope (~ natural [0.72%], ~ 53% and 94%), but the bulk elemental data showed heterogeneity (~ 10% RSD) with U mass fractions ranging from 331.47 to 373.63 μg g -1 . Spatially resolved U isotopic measurements were performed using three mass spectrometry techniques (secondary ion mass spectrometry-single stage accelerator mass spectrometry [SIMS-SSAMS], large geometry [LG] - SIMS, and laser ablation-inductively coupled plasma-mass spectrometry [LA-ICP-MS]) across five National Laboratories. The results showed good agreement with the bulk U isotopic data for the low, medium, and high U mass fractions. We conclude that despite elemental heterogeneity, these samples can serve as useful working reference materials for spatially resolved nuclear fallout analyses, as well as for other related spatially resolved analyses.

36 MATERIALS SCIENCE↗

Mass Spectrometric Measurement of Martian Krypton and Xenon Isotopic Abundance

The Viking gas chromatograph mass spectrometer experiment provided significant data on the atmospheric composition at the surface of Mars, including measurements of several isotope ratios. However, the limited dynamic range of this mass spectrometer resulted in marginal measurements for the important Kr and Xe isotopic abundance. The Xe-129 to Xe-132 ratio was measured with an uncertainty of 70%, but none of the other isotope ratios for these species were obtained. Accurate measurement of the Xe and Kr isotopic abundance in this atmosphere provides an important data point in testing theories of planetary formation and atmospheric evolution. The measurement is also essential for a stringent test for the Martian origin of the SNC meteorites, since the Kr and Xe fractionation pattern seen in gas trapped in glassy nodules of an SNC (EETA 79001) is unlike any other known solar system resevoir. Current flight mass spectrometer designs combined with the new technology of a high-performance vacuum pumping system show promise for a substantial increase in gas throughput and the dynamic range required to accurately measure these trace species. Various aspects of this new technology are discussed.

Mahaffy, P.↗

An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS

Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The energetics of molecular clouds. II - The S140 molecular cloud

Techniques of analysis which allow estimates of kinetic temperature, gas density, gas cooling rate, and dust cooling rate are applied to the S140 molecular cloud. Maps of this cloud in various molecular lines are examined which reveal the existence of a strong temperature and density peak near the H-alpha rim and the presence of a strong near-IR source very near that peak. This source is found to have an energy distribution which is very similar to that of the Becklin-Neugebauer object, including the silicate feature at 9.5 microns. The heating and cooling rates for the gas and dust in S140 are estimated, and the predicted cooling rate for dust is shown to be much greater than that for gas. The molecular-line observations are compared with a spherical large-velocity-gradient trapping calculation. An optimum cloud model is developed which indicates that: (1) (C-13)O, HCO(+), and H2CO are about 10 times less abundant in S140 than in dark clouds; (2) the HCN abundance is approximately 4 times the H2CO abundance in S140, compared with roughly equal values in dark clouds; and (3) the (C-13)O/C(O-18) ratio is consistent with terrestrial isotope ratios.

Blair, G. N.↗

Water vapor isotopic composition during TRACER IOP

The TRACER-Iso project took place from June 1 to September 30, 2022 as part of the intensive observation period (IOP) of the Tracking Aerosol Convection Interactions (TRACER) project at the main project site at the La Porte, Texas, municipal airport. The project sought to use measurements of the stable isotopic composition of water vapor to better understand cloud-aerosol interactions in deep convection in a polluted urban setting. Water vapor isotopologue and humidity measurements were determined using a Picarro L2130 Water Vapor Isotope Analyzer. The instrument was deployed in the guest van and consists of three main components: a water vapor isotope analyzer, and a Los Gatos Research Water Vapor Isotope Standard Source (WVISS), and a Los Gatos Research Dry Air Source. Ambient air samples were collected through an inlet located about one meter above roof of the shipping container. Samples were then delivered to the analyzer through teflon tubing by use of an external pump to minimize the transport time between the inlet and analyzer. The inlet tubing was surrounded by a Briskheat heat trace and insulating material to ensure ambient air samples did not fall below the dew point and result in condensation. The analyzer uses cavity ringdown spectroscopy to report isotopic ratios of ambient air samples at a frequency of 1 Hz. The calibration unit of the instrument was used in conjunction with the dry air source to periodically measure the δ values of standard waters. It uses a nebulizer to push small water droplets into a hot chamber that vaporizes the water without fractionation. This vapor was then transported to the analyzer using a built-in compressor and the dry air source, which allows each standard with known δ values to be measured at a wide range of humidity values for post-measurement calibration of ambient air samples. There are multiple sources of uncertainty introduced at different stages during the data collection and processing. These include (1) instrument precision, (2) uncertainty in the secondary standards, (3) humidity-correction uncertainty, and (4) VSMOW-SLAP calibration uncertainty. Uncertainty from each step is propagated in quadrature to calculate a total uncertainty of each isotopologue. Uncertainty was determined to be 2.3‰ for δD and 0.4‰ for δ18O.

54 ENVIRONMENTAL SCIENCES↗

Interchange for Joint Research Entitled: Measurement of Stable Nitrogen and Sulfur Isotopes

Viking measurements of the Martian atmosphere indicate a value of N-15/N-14 which is markedly greater than that found in Earth's atmosphere. These isotopic measurements provide a powerful diagnostic tool which may be used to derive valuable information regarding the past history of Mars and they have been used to place important constraints on the evolution of Mars' atmosphere. Initial partial pressures of nitrogen, outgassing rates, and integrated deposition of nitrogen into minerals have been calculated from this important atmospheric data (McElroy et al., 1976 and 1977; Fox and Dalgarno, 1983). The greater precision obtained in laser spectrometer isotopic measurements compared to the Viking data will greatly improve these calculated values. It has also been proposed that the N-15/N-14 value in Mars' atmosphere has increased monotonically over time (McElroy et al., 1977; Fox and Dalgarno, 1983; Wallis, 1989) owing to preferential escape of atmospheric 14N to space. Nitrogen isotopic ratios might be used to identify relatively ancient crustal rocks (R. Mancinelli, personal communication), and perhaps determine relative aces of surface samples. As a first step in successfully measuring nitrogen isotopes optically we have demonstrated the measurement of 15NI14N to a precision of 0.1% (See Figures 1-4) using a tunable diode laser and an available gas (N-,O) with spectral lines in the 2188 cm-1 region. The sample and reference gas cells contained gases of identical isotopic composition so that the 15NI14N absorption ratio determined from the sample cell, when divided by the 15NI14N absorption ratio determined from the reference cell, should yield an ideal value of unity. The average measured value of this "ratio of ratios" was 0.9983 with a standard deviation (20 values) of 0.0010. This corresponds to a precision of 0.1% (1 per mil) for nitrogen isotopes, a value sufficiently precise to provide important isotopic data of interest to exobiologists. The precision presently attainable in gases is sufficient to permit the instrument to be used in the measurement of isotopic ratios of interest to exobiologists as well as geologists and planetary scientists.

Becker, Joseph F.↗

Quantifying replication through repeated analysis of UVM-A, a liquid reference material for cosmogenic 10 Be and 26 Al studies

In this study, in-situ produced cosmogenic nuclide sample preparation and analysis is a complicated, multi-step process with numerous possible sources of error, many of which have not been robustly quantified. Here, we use a liquid reference material (UVM-A) to test whether the analytic precision associated with individual isotopic ratios (n = 96) measured at two Accelerator Mass Spectrometry facilities (Lawrence Livermore National Laboratory and Purdue Rare Isotope Measurement Laboratory) accurately represents the range of values determined for aliquots prepared in a single laboratory over a period of five years. We find that 10 Be/ 9 Be ratios measured at the different accelerator facilities (n = 26 and n = 70) have statistically indistinguishable central tendencies, matching to within 0.1 %. Based on this large dataset, we suggest preliminary consensus values for UVM-A of 1.45 ± 0.06 x 10 -13 for 10 Be/ 9 Be (mean, one standard deviation, n = 96) and 4.47 ± 0.22 x 10 -13 for 26 Al/ 27 Al (mean, one standard deviation, n = 27). For both 10 Be/ 9 Be and 26 Al/ 27 Al, the relative standard deviations of the measured ratios are similar to the reported analytic uncertainties of sample measurement, suggesting that sample preparation introduced little if any additional scatter beyond the uncertainty of isotopic analysis. This dataset demonstrates that robust sample preparation and measurement can generate isotope ratio data reproducible at the level of counting statistics.

58 GEOSCIENCES↗

Practical considerations for amino acid isotope analysis

Over the last few decades, isotopic analysis of amino acids at the compound- and position-specific levels has been rapidly advancing across diverse fields. As these techniques progress, evaluation of isotopic fractionation associated with sample workup is essential. This critical review of analytical methods through the lens of isotope geochemistry provides a benchmark for researchers across disciplines seeking to make compound- and position-specific amino acid isotope measurements. We focus on preparation, acid hydrolysis, clean-up, derivatization, separation, and C, H, N, and S isotope measurement. Despite substantial customizability across these steps, the following general recommendations should maximize recovery while minimizing isotopic fractionation. Samples should be freeze-dried and stored anoxically at ≤ –20 °C prior to conventional acid hydrolysis (6N HCl, 110 °C, 20–24 h, anoxic), which suffices for many residues. Both gas and liquid chromatographic (GC and LC, respectively) techniques are well-established and separate about 15 amino acids; LC bypasses the need for derivatization, while GC provides higher sensitivity. Furthermore, when derivatization is needed, n-acetyl and alkoxycarbonyl esters provide the most reproducible C isotope ratios. For compound-specific analyses, online GC–IRMS and LC–IRMS systems offer the easiest workflow, but EA–IRMS enables potential multi-element isotope analysis. Emerging techniques like high-resolution mass spectrometry are also promising for multi-element analysis and recover position-specific isotopic information. Looking forward to the next decade of innovation, isotope geochemists and ecologists can improve amino acid isotope analysis by focusing on streamlining multi-element analysis and standardizing calibration practices across laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotopic abundances of stratospheric ozone from balloon-borne high-resolution infrared solar spectra

IR solar absorption spectra at 0.002-0.0003/cm resolution in the 10-micron region obtained during two balloon flights near 32 deg N latitude are examined to determine the isotopic ratios of (O-16)(O-16)(O-18) and (O-16)(O-18)(O-16) relative to normal ozone in the stratosphere. For November 18, 1987, the results show column-averaged isotopic enhancement ratios of 1.20 + or - 0.14 and 1.40 + or - 0.18 for (O-16)(O-18)(O-16)/(O-16)(O-16)(O-16) and (O-16)(O-16)(O-18)/(O-16)(O-16)(O-16), respectively. The corresponding values for June 6, 1988, show ratios of 1.16 + or - 0.08 and 1.25 + or - 0.12. The results are compared with heavy-to-normal O3 ratios obtained using other techniques.

Goldman, A.↗

Isotope effects and Alfvén eigenmode stability in JET H, D, T, DT, and He plasmas

While much about Alfvén eigenmode (AE) stability has been explored in previous and current tokamaks, open questions remain for future burning plasma experiments, especially regarding exact stability threshold conditions and related isotope effects; the latter, of course, requiring good knowledge of the plasma ion composition. In the JET tokamak, eight in-vessel antennas actively excite stable AEs, from which their frequencies, toroidal mode numbers, and net damping rates are assessed. The effective ion mass can also be inferred using measurements of the plasma density and magnetic geometry. Thousands of AE stability measurements have been collected by the Alfvén Eigenmode Active Diagnostic in hundreds of JET plasmas during the recent Hydrogen, Deuterium, Tritium, DT, and Helium-4 campaigns. In this novel AE stability database, spanning all four main ion species, damping is observed to decrease with increasing Hydrogenic mass, but increase for Helium, a trend consistent with radiative damping as the dominant damping mechanism. These data are important for confident predictions of AE stability in both non-nuclear (H/He) and nuclear (D/T) operations in future devices. In particular, if radiative damping plays a significant role in overall stability, some AEs could be more easily destabilized in D/T plasmas than their H/He reference pulses, even before considering fast ion and alpha particle drive. Active MHD spectroscopy is also employed on select HD, HT, and DT plasmas to infer the effective ion mass, thereby closing the loop on isotope analysis and demonstrating a complementary method to typical diagnosis of the isotope ratio.

Alfvén eigenmodes↗

Infrared spectroscopic method for uranium isotopic analysis

A high performance infrared (HPIR) system was developed and demonstrated for the infrared absorption analysis of {sup 235}U and {sup 238}U isotopes in uranium hexafluoride gas samples. Sweeping the quantum cascade laser light source over the spectral range and sampling via a high-rate analog-to-digital converter provided 0.0005 cm-1 spectral resolution, which allowed for high-precision measurements of the isotopic peak shift. A data analysis method was developed using principal component analysis to predict the isotope weight % content of {sup 235}U. The HPIR precision, accuracy, and error were evaluated for a wide range of isotopic ratio samples (0.287 – 93.7 weight % {sup 235}U), and the results were compared to the International Target Values (ITVS) set forth by the International Atomic Energy Agency (IAEA) for non-destructive and destructive analytical techniques. The method meets or surpasses the IAEA ITVs for non-destructive analysis of samples with isotopic content of depleted to highly enriched. The results also demonstrated the capability of the HPIR system to correctly predict the {sup 235}U weight % content of a mislabeled sample whose isotopic distribution was validated by mass spectroscopic measurements. The HPIR measurement is nondestructive and, thus, allows for confirmatory analyses of the exact sample at a designated IAEA lab if higher-resolution or a certified analysis is needed. (author)

07 ISOTOPE AND RADIATION SOURCES↗

AmeriFlux FLUXNET-1F US-ARM ARM Southern Great Plains site- Lamont

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont. This is the FLUXNET version of the carbon flux data for the site US-ARM ARM Southern Great Plains site- Lamont produced by applying the standard ONEFlux (1F) software. Site Description - Central facility tower crop field (winter wheat, corn, soy, alfalfa). The site also has continuous measurements of precise mixing ratios of CO2, CH4, CO, N2O, and isotopic ratio of 13CO2. In addition to 4 m system, there are sonic anemometers at 25 m and 60 m.

Biraud, Sebastien↗

Chemical Compositions of Red Giant Stars from Habitable Zone Planet Finder Spectroscopy

We have used the Habitable Zone Planet Finder (HPF) to gather high-resolution, high signal-to-noise near-infrared spectra of 13 field red horizontal branch (RHB) stars, one open cluster giant, and one very metal-poor halo red giant. The HPF spectra cover the 0.81–1.28 μm wavelength range of the zyJ bands, partially filling the gap between the optical (0.4–1.0 μm) and infrared (1.5–2.4 μm) spectra already available for the program stars. We derive abundances of 17 species from LTE-based computations involving equivalent widths and spectrum syntheses, and estimate abundance corrections for the species that are most affected by departures from LTE in RHB stars. Generally good agreement is found between HPF-based metallicities and abundance ratios and those from the optical and infrared spectral regions. Light element transitions dominate the HPF spectra of these red giants, and HPF data can be used to derive abundances from species with poor or no representation in optical spectra (e.g., C i, P i, S i, K i). Attention is drawn to the HPF abundances in two field solar-metallicity RHB stars of special interest: one with an extreme carbon isotope ratio, and one with a rare, very large lithium content. The latter star is unique in our sample in exhibiting very strong He i 10830 Å absorption. The abundances of the open cluster giant concur with those derived from other wavelength regions. Detections of C i and S i in HD 122563 are reported, yielding the lowest metallicity determination of [S/Fe] from more than one multiplet.

47 OTHER INSTRUMENTATION↗

Applications of Hyporheic Zone Sampling for Assessing VOC Plume Engineered Remediation and Natural Attenuation Effectiveness - 20414

Determining the efficacy of engineered remedial actions and/or natural attenuation as an acceptable EPA Record of Decision (ROD) must address long-term temporal and spatial variability. Since final plume downslope destinations are aquifers and related surface streams and rivers, hyporheic zone sampling is essential. Comprehensive hyporheic sampling documents plume groundwater remediation prior to upwelling into stream benthic strata and natural attenuation within this dynamic zone itself. Our intensive sampling of the Savannah River Site (SRS) Chemical, Metals, and Pesticides (CMP) Pits VOC plume-fringe from 2005 to 2018 documented PCE natural attenuation and effectiveness of In Situ Thermal Treatment (ISTT). Most plume hyporheic upwelling was delimited to a 20 m inflow reach along Pen Branch. Our study utilized corroborative sampling methodologies: ambient hole-water grab samples: passive diffusion bags (PDB); and hole-core sediment samples to confirm station to station spatial and temporal trends. VOC hot spot detections were confirmed from both groundwater and soil core samples. VOC pathways through the Pen Branch hyporheic zone were assessed at hole-installation using sequential soil samples from augered cores and grab-samples of hole-bottom water. Longer term, composite water samples were collected from PDBs deployed for a minimum two-week equilibration period. Soil samples were collected from the 15 and 65 cm core levels in December 2017 and June 2018 at six stations. Additional core depths of 40 and 85 cm were sampled in June 2018 at the highest VOC station (5DB80). All samples were analyzed in an EPA certified lab by purge and trap GC-MS. Effectiveness of previous ISTT and soil vapor extraction (SVE) for this CMP Pits PCE plume, was clearly documented by significant downward trends in VOC at hyporheic zone stations prior to December 2015. Achieving final stage conversions of PCE daughter products to ethene and CO{sub 2} may be limited depending upon suitable interactions between hyporheic zone sediment morphology, hydrology, and redox conditions. Because declines in VOC daughter products at our hyporheic stations may also be caused by physical actions of dilution and dispersion rather than true biochemical dechlorination, full quantification of natural attenuation requires the use of compound-specific isotope ratio analysis (CSIA) and microbial 16S rRNA with qPCR. To assist these next-phase efforts, a natural attenuation index (NAI) was used to help produce quicker, more cost-effective decision making for locating CSIA and microbial sampling efforts. The NAI used natural logarithm transformed GC-MS results for station VOC degradation compounds versus VOC parent compounds. Wide differences were observed between stations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Predicted versus observed cosmic-ray-produced noble gases in lunar samples - Improved Kr production ratios

New sets of cross sections for the production of krypton isotopes from targets of Rb, Sr, Y, and Zr have been constructed primarily on the bases of experimental excitation functions for Kr production from Y. These cross sections were used to calculate galactic-cosmic-ray and solar-proton production rates for Kr isotopes in the moon. The paper reports spallation Kr data obtained from ilmenite separates of rocks 10017 and 10047. Production rates and isotopic ratios for cosmogenic Kr observed in ten well-documented lunar samples and in ilmenite separates and bulk samples from several lunar rocks with long but unknown irradiation histories were compared with predicted rates and ratios. The agreements were generally quite good.

Regnier, S.↗